Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Material properties”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

The Interpretation of XPS Spectra: Insights Into Materials Properties

We review basic and advanced concepts needed for the correct analysis of XPS features. We place these concepts on rigorous foundations and explore their physical and chemical meanings without stressing the derivation of the mathematical formulations, which can be found in the cited literature. The significance and value of combining theory and experiment is demonstrated by discussions of the physical and chemical origins of the main and satellite XPS features for a variety of molecular and condensed phase materials.

Environmental Molecular Sciences Laboratory↗

Investigation of Test Methods, Material Properties, and Processes for Solar Cell Encapsulants

During this quarter the technical activities were directed toward the reformulation of ethylene/vinyl acetate copolymer for use as a compound in solar cell module fabrication. Successful formulations were devised that lowered the temperature required for cure and raised the gel content. A major volatile component was also eliminated (acrylate crosslinking agent) which should aid in the production of bubble free laminates. Adhesive strengths and primers for the bonding of ethylene/vinyl acetate to supersyrate and substrate materials was assessed with encouraging results. The incorporation of silane compounds gave high bond strengths. A survey of scrim materials was also conducted.

Source record↗

Material properties limiting the performance of CZT gamma-ray detectors

CdZnTe (CZT) nuclear radiation detectors are advanced sensors that utilize innovative technologies developed for wide band-gap semiconductor industry and microelectronics. They open opportunities for new types of room-temperature operating, field deployable instruments that provide accurate identification of potential radiological threats and timely awareness for both the civilian and military communities. Room-temperature radiation detectors are an emerging technology that relies on the use of high-quality CZT crystals whose availability is currently limited by material non-uniformities and the presence of extended defects. To address these issues, which are most critical to CZT sensor developments, we developed X-ray mapping and IR transmission microscopy systems to characterize both CZT crystals and devices. Since a customized system is required for such X-ray measurements, we use synchrotron radiation beams available at BNL's National Synchrotron Light Source. A highly-collimated and high-intensity X-ray beam supports measurements of areas as small as 10 x 10 {micro}m{sup 2}, and allowed us to see fluctuations in collected charge over the entire area of the detector in a reasonable time. The IR microscopy system allows for 3D visualization of Te inclusions and other extended defects. In this paper, we describe the experimental techniques used in our measurements and typical results obtained from CZT samples produced by different suppliers.

43 PARTICLE ACCELERATORS↗

Material Properties Governing Co-Current Flame Spread: The Effect of Air Entrainment

A study on the effects of lateral air entrainment on an upward spreading flame has been conducted. The fuel is a flat PMMA plate of constant length and thickness but variable width. Video images and surface temperatures have allowed establishing the progression of the pyrolyis front and on the flame stand-off distance. These measurements have been incorporated into a theoretical formulation to establish characteristic mass transfer numbers ("B" numbers). The mass transfer number is deemed as a material related parameter that could be used to assess the potential of a material to sustain co-current flame spread. The experimental results show that the theoretical formulation fails to describe heat exchange between the flame and the surface. The discrepancies seem to be associated to lateral air entrainment that lifts the flame off the surface and leads to an over estimation of the local mass transfer number. Particle Image Velocimetry (PIV) measurements are in the process of being acquired. These measurements are intended to provide insight on the effect of air entrainment on the flame stand-off distance. A brief description of the methodology to be followed is presented here.

Coutin, Mickael↗

Influence of geometric and material properties on artifacts generated by interventional MRI devices: Relevance to PRF-shift thermometry

Purpose: Magnetic resonance imaging (MRI) is capable of providing valuable real-time feedback during medical procedures, partly due to the excellent soft-tissue contrast available. Several technical hurdles still exist to seamless integration of medical devices with MRI due to incompatibility of most conventional devices with this imaging modality. In this study, the effect of local perturbations in the magnetic field caused by the magnetization of medical devices was examined using finite element analysis modeling. As an example, the influence of the geometric and material characteristics of a transurethral high-intensity ultrasound applicator on temperature measurements using proton resonance frequency (PRF)-shift thermometry was investigated. Methods: The effect of local perturbations in the magnetic field, caused by the magnetization of medical device components, was examined using finite element analysis modeling. The thermometry artifact generated by a transurethral ultrasound applicator was simulated, and these results were validated against analytic models and scans of an applicator in a phantom. Several parameters were then varied to identify which most strongly impacted the level of simulated thermometry artifact, which varies as the applicator moves over the course of an ablative high-intensity ultrasound treatment. Results: Key design parameters identified as having a strong influence on the magnitude of thermometry artifact included the susceptibility of materials and their volume. The location of components was also important, particularly when positioned to maximize symmetry of the device. Finally, the location of component edges and the inclination of the device relative to the magnetic field were also found to be important factors. Conclusions: Previous design strategies to minimize thermometry artifact were validated, and novel design strategies were identified that substantially reduce PRF-shift thermometry artifacts for a variety of device orientations. These new strategies are being incorporated into the next generation of applicators. The general strategy described in this study can be applied to the design of other interventional devices intended for use with MRI.

61 RADIATION PROTECTION AND DOSIMETRY↗

Development of Uncertainty and Material Property "Truth" Models and Results for Cantilever Beam End-to-End UQ Problem

Construction of a test problem that quantitatively tests the effectiveness and robustness of the many features and capabilities that a comprehensive E2E UQ framework should have is very challenging. Accordingly, this report illustrates many of the considerations and numerical investigations that went into the construction of the Sandia Cantilever Beam End-to-End UQ test problem.

36 MATERIALS SCIENCE↗

Water-Immersed Polymer Interfaces and the Roles of Their Materials Properties on Biolubrication

This project focused on investigating and fundamentally understanding the roles of the structure and interfacial interactions of neutral polymer thin films in aqueous solutions on biolubrication, and to go beyond this, to molecular design tunable and functional polymer thin films as low-friction, lubricious coatings. Single-molecule fluorescence microscopy and spectroscopy are integrated with an interfacial rheometer to enable the interfacial force measurement and “seeing” the structural dynamics of single molecules or particles or their aggregates confined at surface simultaneously.

36 MATERIALS SCIENCE↗

Transfer Tube Material Properties Obtained from Test Data

A series of tension and compression tests were performed on typical transfer tubes made of 304L corrosion-resistant steel. The results were compiled and converted to true stress and true plastic strain for comparison to numerical models. The parameters of a Johnson-Cook constitutive model and fracture criterion were calibrated to mimic the test data. Comparisons were made between the converted data and the empirical formulas in the Johnson-Cook model. Simulations were performed to evaluate the implementation of the formula in finite element analysis, and the parameters were adjusted to improve the correlation.

36 MATERIALS SCIENCE↗

Probe-rotating atomic force microscopy for determining material properties

In this paper, we propose a probe-rotating atomic force microscope that enables scan in an arbitrary direction in the contact imaging mode, which is difficult to achieve using a conventional atomic force microscope owing to the orientation-dependent probe and the inability to rotate the probe head. To enable rotation of the probe about its vertical axis, we employed a compact and light probe head, the sensor of which is made of an optical disk drive pickup unit. Our proposed mechanical configuration, operating principle, and control system enables axial and lateral scan in various directions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Material Properties from ab initio Calculations [Slides]

Summary and Future Direction: Diffusion coefficients - Calculated and compared with experimental viscosity; More work on solid state diffusion coefficients. Heat capacity - Calculated and compared with Ce heat capacity; Need to calculate the solid heat capacity and find more experimental data. Heat of formation - Calculated for one and two Ce atoms; Slab calculations are under way for a surface. Reaction rate - Calculation of a single Ce atom reaction is in progress; Simulations of larger clusters for comparison with ionic reaction experiments. Emissivity and Thermal Conductivity - Single snapshot calculated; Averaging over ionic configurations at different T is in progress.

36 MATERIALS SCIENCE↗

Uncertainty Quantification for Smooth Functional Data with Application to Material Properties

This document outlines a method for processing functional output (i.e., curves) for the ultimate purpose of sampling curves under specified input conditions for use in modeling and simulation uncertainty quantification (UQ) studies. A set of benchmark curves sufficiently representative of the relevant scenario(s) being simulated are provided to the process and formatted as described in Section 1. Principal Component Analysis (PCA) is utilized to discover the components of uncertainty in the benchmark curves and is outlined in Section 2. Section 3 describes the application of uncertainty quantification to the PCA results for the purpose of sampling curves to be used in UQ analysis. Section 4 applies these techniques to an example benchmark dataset. Concluding remarks are provided in the final section.

36 MATERIALS SCIENCE↗

Clarifying trust of materials property predictions using neural networks with distribution-specific uncertainty quantification

It is critical that machine learning (ML) model predictions be trustworthy for high-throughput catalyst discovery approaches. Uncertainty quantification (UQ) methods allow estimation of the trustworthiness of an ML model, but these methods have not been well explored in the field of heterogeneous catalysis. Herein, we investigate different UQ methods applied to a crystal graph convolutional neural network to predict adsorption energies of molecules on alloys from the Open Catalyst 2020 dataset, the largest existing heterogeneous catalyst dataset. We apply three UQ methods to the adsorption energy predictions, namely k-fold ensembling, Monte Carlo dropout, and evidential regression. The effectiveness of each UQ method is assessed based on accuracy, sharpness, dispersion, calibration, and tightness. Evidential regression is demonstrated to be a powerful approach for rapidly obtaining tunable, competitively trustworthy UQ estimates for heterogeneous catalysis applications when using neural networks. Recalibration of model uncertainties is shown to be essential in practical screening applications of catalysts using uncertainties.

36 MATERIALS SCIENCE↗

Cross-scale covariance for material property prediction

A simulation can stand its ground against an experiment only if its prediction uncertainty is known. The unknown accuracy of interatomic potentials (IPs) is a major source of prediction uncertainty, severely limiting the use of large-scale classical atomistic simulations in a wide range of scientific and engineering applications. Here we explore covariance between predictions of metal plasticity, from 178 large-scale (~10 8 atoms) molecular dynamics (MD) simulations, and a variety of indicator properties computed at small-scales (≤10 2 atoms). All simulations use the same 178 IPs. In a manner similar to statistical studies in public health, we analyze correlations of strength with indicators, identify the best predictor properties, and build a cross-scale “strength-on-predictors” regression model. This model is then used to estimate regression error over the statistical pool of IPs. Small-scale predictors found to be highly covariant with strength are computed using expensive quantum-accurate calculations and used to predict flow strength, within the statistical error bounds established in our study.

36 MATERIALS SCIENCE↗

Correlation between failure and local material property in chopped carbon fiber chip-reinforced sheet molding compound composites under tensile load

To develop further understanding towards the role of a heterogeneous microstructure on tensile crack initiation and failure behavior in chopped carbon fiber chip-reinforced composites, uni-axial tensile tests are performed on coupons cut from compression molded plaque with varying directions. Our experimental results indicate that failure initiation is relevant to the strain localization, and a new criterion with the nominal modulus to predict the failure location is proposed based on the strain analysis. Furthermore, optical microscopic images show that the nominal modulus is determined by the chip orientation distribution. At the area with low nominal modulus, it is found that chips are mostly aligning along directions transverse to loading direction and/or less concentrated, while at the area with high nominal modulus, more chips are aligning to tensile direction. On the basis of failure mechanism analysis, it is concluded that transversely-oriented chips or resin-rich regions are easier for damage initiation, while longitudinally-oriented chips postpone the fracture. Good agreement is found among failure mechanism, strain localization and chip orientation distribution.

36 MATERIALS SCIENCE↗

Bismuth in Lead–Tin Alloy Perovskites: Effect on Material Properties and Photovoltaic Device Performance

Metal halide perovskites (MHPs) have a strong potential for optoelectronic applications, especially photovoltaics. A significant advantage offered by MHPs is their bandgap tunability via chemical substitution and alloying, with lead–tin alloys producing the narrowest reported bandgaps of ~1.2 eV. Efforts to further narrow the bandgap of MHPs by alloying in other elements, such as bismuth, have largely been unsuccessful due to the introduction of defective electronic states, which severely diminish electronic quality. Here, in this study, we examine the effects of bismuth on a lead–tin alloyed MHP, motivated by the narrow bandgap of alloyed lead–tin MHPs. We find that the defect screening observed in lead–tin MHPs is not sufficient to screen the defect level introduced by bismuth, as evidenced by quenched photoluminescence, decreased mobility, and severely reduced performance in a photovoltaic device. Density functional theory calculations suggest that midgap states are introduced by bismuth addition over a range of chemical and compositional conditions. We further observe through wavelength-dependent photoconductivity that free carriers are generated out to ~0.9 eV in bismuth-containing samples, which could be of potential interest for NIR photodetection.

14 SOLAR ENERGY↗

Deriving Material Properties from Feedback Error Signals in Scanning Tunneling Microscopy

Imperfections in measurements, e.g., deviations and broadening, are not devoid of information; rather, they can reveal valuable physical properties and processes. Scanning tunneling microscopy leverages a negative feedback loop to regulate the tunneling current. Practically, current fluctuates around its set point, and such deviations are considered insignificant and ignored. Here, in this study, we investigate the information embedded in these deviations. In the constant-current mode with an active feedback loop, we observe an unexpected persistent DC current offset from its set point when the tunneling junction is periodically perturbed. We demonstrate both experimentally and theoretically that such error signals encode local tunneling barrier heights and the square of local differential conductance as a consequence of the interplay between rectification and active feedback compensation. We provide evidence on the generalizability of this phenomenology to other negative feedback systems. This new approach has the potential to broadly impact physical sciences by allowing rapid measurements without lock-in amplifiers.

36 MATERIALS SCIENCE↗

Silane injection in a high-density low-pressure plasma system and its influence on the deposition kinetics and material properties of SiO{sub 2}

High-rate, low temperature deposition is an essential requirement for industrial fabrication technology to be suitable for the deposition of optical and protective coatings. High-density, low-pressure plasmas have received significant attention for such applications due to their ability to create large and controllable ion fluxes onto the substrate. In this study, the high-rate deposition of silica films from a silane and oxygen gas mixture in a high-density plasma system based on a matrix distributed electron cyclotron resonance (MDECR) plasma source is investigated using directional jet injection of undiluted silane. The influence of process parameters such as the microwave power, radio frequency biasing of the substrate holder, and gas flows on the OH content of the oxide films is studied using phase-modulated spectroscopic ellipsometry (SE), Fourier transform infrared (FTIR) spectroscopy, and transmission measurements. The results of the measurements, taken at various points across the wafer, show a decrease in the thickness-normalized OH concentration in the areas of higher deposition rates. The corresponding gas phase composition is investigated using optical emission spectroscopy and compared to the FTIR, transmission and SE measurement results in order to validate our findings and ultimately optimize the deposition process. It is found that the primary silane flux onto the surface, which depends on the positioning of the jet injection point and gas flow rate, plays an important role not only on the deposition rate but also on the OH content of the films. The authors conclude that high-density plasma deposition systems such as the MDECR plasma enhanced chemical vapor deposition system cannot be considered as well mixed for gases with dissociation products that have high sticking coefficients, contrary to the accepted paradigm.

36 MATERIALS SCIENCE↗