Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Material Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Screening and tests of materials for space applications

The outgassing properties of materials and other considerations on materials acceptance for space applications are discussed. The uses of the outgassing data for the evaluation of important performance characteristics of a space system are indicated. The deficiencies and advantages of the ASTM-E595-77 test method and materials acceptance criteria are discussed. Also discussed are the advantages for the selection of the materials and the uses of the data provided by the long-term measurements of the outgassing rates and surface re-emission of materials. The paper concludes that the results of the ASTM method with additional derived data on the material properties can be used for the initial evaluation of a space system's characteristics. Materials data on outgassing and re-emission rates at various temperatures obtained from the more expensive, long-term QCM and TGA measurements should be obtained when a detailed analysis of a system is suggested based on the various considerations discussed in the paper.

Scialdone, J. J.↗

Baseline tensile tests of composite materials for LDEF (Long Duration Exposure Facility) exposure

Tensile specimens of five graphite fiber reinforced composite materials were tested at room temperature to provide baseline data for similar specimens exposed to the space environment in low-Earth orbit on the NASA Long Duration Exposure Facility. All specimens were 4-ply (+ or - 45 deg)s layups; at least five replicate specimens were tested for each parameter evaluated. Three epoxy-matrix materials and two polysulfone-matrix materials, several fiber volume fractions, and two sizes of specimen were evaluated. Stress-strain and Poisson's ratio-stress curves, ultimate stress, strain at failure, secant modulus at 0.004 strain, inplane shear stress-strain curves, and unidirectional shear modulus at .004 shear strain are presented.

Witte, William G.↗

Material Response Analysis of PICA-NuSil at the Hypersonic Materials Environmental Test System

Phenolic impregnated carbon ablator (PICA) is a thermal protection system (TPS) that gained heritage during the Stardust mission and is the baseline TPS material for expeditions to Mars (e.g., Mars Science Laboratory and Mars 2020).1 PICA is friable; therefore, a polysiloxane resin (NuSil CV-1144-0) is deposited onto the surface of flight hardware before assembly, test, and launch operations (ATLO) to mitigate particle shedding. Furthermore, the Mars Science Laboratory (MSL) and Mars 2020 heatshields were instrumented with an array of thermocouple plugs (MEDLI Integrated Sensor Plugs or MISP) designed to measure the in-depth thermal response of PICA during flight. Post-flight analysis of MISP data suggests that recession was lower than predicted, and NuSil is suspected as a reasonable cause. NuSil primarily consists of a copolymer blend of dimethyl and diphenyl-substituted polysiloxane resin. Four decades of research in the field of polymer-derived ceramics demonstrate that polysiloxane resins form oxidation-resistant silicon oxycarbide materials at pyrolysis temperatures as low as 800 °C. -2 Furthermore, silicon oxycarbide materials exhibit excellent thermal stability at relatively high-temperatures (< 1200 °C) but eventually decompose via carbothermal reduction. -3 Therefore, it is reasonable to suggest that NuSil forms an oxidation-resistant thermal barrier coating on the TPS surface and influences the material response during atmospheric entry. Evidence for this notion was observed during prior arc-jet testing at both the Aerodynamic Heating Facility (AHF) and the Panel Test Facility (PTF) at the NASA Ames Research Center. Articles of PICA were subjected to testing in airflow, and a temperature discontinuity was recorded at the surface of coupons coated with NuSil. A glassy coating was observed to form at the surface in shear flow configurations (wedge and panel) under moderate heat fluxes. Furthermore, state-of-the-art material response models have yet to account for the underlying physics and chemistry of the temperature discontinuity. To this end, a pathfinder test campaign was executed at the Hypersonic Materials Environmental Test System (HyMETS) to enhance the fundamental understanding of PICA-NuSil ablation phenomena and provide a preliminary data set to aid in the development of material response models.

PICA↗

STANDARD REFERENCE MATERIAL CHARPY TESTING FROM HIGH FLUENCE SURVEILLANCE CAPSULE

The Palisades Nuclear Generating Station included in its original surveillance program a surveillance capsule, designated A-60. The capsule was removed from its surveillance position in early 1995 and has been resident in the spent fuel pool since that time. It was harvested to perform characterization of surveillance specimens in this capsule in 2023. This capsule was irradiated to a fluence of 1.96x1020 n/cm2 (E> 1MeV) that is equivalent for more than 150 effective full power years for the current US reactor pressure vessel (RPV) fleet. This capsule contained several materials, including Charpy specimens of standard reference material (SRM) from Heavy-Section Steel Technology (HSST) A533-B Plate 01. To perform Charpy testing of this highly irradiated material, the new Charpy specimen transfer system was designed and implemented on Charpy impact testing machine in the hot cell to accommodate remote testing of these specimens. This new transfer system includes integrated environmental chamber to cool or heat Charpy specimens to the desired temperature. Testing of this highly irradiated material revealed very large shift of Charpy transition temperature, 188oC.

Sokolov, Mikhail [ORNL] (ORCID:0000000256373346)↗

NEET Micro-Pocket Fission Detector - FY 2012 Status Report

A research program has been initiated by the NEET program for developing and testing compact miniature fission chambers capable of simultaneously measuring thermal neutron flux, fast neutron flux and temperature within a single package. When implemented, these sensors will significantly advance flux detection capabilities for irradiation tests in US Materials Test Reactors (MTRs). Ultimately, evaluations may lead to a more compact, more accurate, and longer lifetime flux sensor for critical mock-ups, high performance reactors and commercial nuclear power plants. Deployment of Micro-Pocket Fission Detectors (MPFDs) in US DOE-NE program irradiation tests will address several challenges: Current fission chamber technologies do not offer the ability to measure fast flux, thermal flux and temperature within a single compact probe, MPFDs offer this option. MPFD construction is very different then current fission chamber construction; the use of high temperature materials allow MPFDs to be specifically tailored to survive harsh conditions in typical high performance MTR irradiation tests.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Laser-Enhanced Arc-Jet Facility Wedge Tests: Avcoat Material Performance Under Convective and Radiative Heating Environments

This paper presents the first set of experimental results from Laser Enhanced Arc-Jet Facility (LEAF-Lite) tests that were conducted shortly after the radiative LEAF-Lite system was added to the 60-MW Interaction Heating Facility at NASA Ames Research Center. Results were gathered to characterize the new radiative and combined heating capabilities as well as the convective heating resulting from the new IHF nozzle that was required for combined heating operations. Tests were ultimately conducted at several combinations of radiative and convective heating prompted by the need to understand the effect of combined heating on the Orion heatshield material prior to pursuing combined heating tests of the more complex block architecture.

Laser-Enhanced Arc-Jet Facility↗

Investigation of test methods, material properties and processes for solar cell encapsulants

Low cost encapsulation materials for the Flat Plate Solar Array Program (FSA) are investigated. The goal of the program is to identify, test, evaluate and recommend encapsulation materials and processes for the fabrication of cost effective and long life solar modules. Accelerated aging techniques for module component lifetime studies, investigation of candidate outer cover films and continued evaluation of soil repellant coatings are also included.

Willis, P. B.↗

Solar Probe thermal shield design and testing

This paper discusses the major thermal shield subsystem development activities in support of the Solar Probe study being conducted at JPL. The Solar Probe spacecraft will travel to within 4 solar radii of the sun's center to perform fundamental experiments in space physics. Exposure to 2900 earth suns at perihelion requires the spacecraft to be protected within the shadow envelope of a protective shield. In addition, the mass loss rate off of the shield at elevated temperature must comply with plasma instrument requirements and has become the driver of the shield design. This paper will focus on the analytical design work to size the shield and control the shield mass loss rate for the various spacecraft options under study, the application of carbon-carbon materials for shield components, development and preparation of carbon-carbon samples for materials testing, and a materials testing program for carbon-carbon and tungsten alloys to investigate thermal/optical properties, mass loss (carbon-carbon only), material integrity, and high velocity impact behavior.

Millard, Jerry M.↗

High Temperature Ultrasonic Transducers : Material Selection and Testing

The task of my two-months internship was to test different materials to be used to build an high temperature transducer, to develop some prototypes and to test their performance, to assess the reliability of commercial product rated for such a temperature, as well as to collaborate in developing the signal processing code to measure the condensed water levels.

health monitoring steam pipes↗

A computer program for plotting stress-strain data from compression, tension, and torsion tests of materials

A computer program for plotting stress-strain curves obtained from compression and tension tests on rectangular (flat) specimens and circular-cross-section specimens (rods and tubes) and both stress-strain and torque-twist curves obtained from torsion tests on tubes is presented in detail. The program is written in FORTRAN 4 language for the Control Data 6000 series digital computer with the SCOPE 3.0 operating system and requires approximately 110000 octal locations of core storage. The program has the capability of plotting individual strain-gage outputs and/or the average output of several strain gages and the capability of computing the slope of a straight line which provides a least-squares fit to a specified section of the plotted curve. In addition, the program can compute the slope of the stress-strain curve at any point along the curve. The computer program input and output for three sample problems are presented.

Greenbaum, A.↗

Materials Combustion Testing and Combustion Product Sensor Evaluations in FY12

NASA Centers continue to collaborate to characterize the chemical species and smoke particles generated by the combustion of current space-rated non-metallic materials including fluoropolymers. This paper describes the results of tests conducted February through September 2012 to identify optimal chemical markers both for augmenting particle-based fire detection methods and for monitoring the post-fire cleanup phase in human spacecraft. These studies follow up on testing conducted in August 2010 and reported at ICES 2011. The tests were conducted at the NASA White Sands Test Facility in a custom glove box designed for burning fractional gram quantities of materials under varying heating profiles. The 623 L chamber was heavily instrumented to quantify organics (gas chromatography/mass spectrometry), inorganics by water extraction followed by ion chromatography, and select species by various individual commercially-available sensors. Evaluating new technologies for measuring carbon monoxide, hydrogen cyanide, hydrogen fluoride, hydrogen chloride and other species of interest was a key objective of the test. Some of these sensors were located inside the glovebox near the fire source to avoid losses through the sampling lines; the rest were located just outside the glovebox. Instruments for smoke particle characterization included a Tapered Element Oscillating Microbalance Personal Dust Monitor (TEOM PDM) and a TSI Dust Trak DRX to measure particle mass concentration, a TSI PTrak for number concentration and a thermal precipitator for collection of particles for microscopic analysis. Materials studied included Nomex®, M22759 wire insulation, granulated circuit board, polyvinyl chloride (PVC), Polytetrafluoroethylene (PTFE), Kapton®, and mixtures of PTFE and Kapton®. Furnace temperatures ranged from 340o to 640o C, focusing on the smoldering regime. Of particular interest in these tests was confirming burn repeatability and production of acid gases with different fuel mixture compositions, as well as the dependence of aerosol concentrations on temperature.

Smoke↗

Materials Combustion Testing and Combustion Product Sensor Evaluations in FY12

NASA Centers continue to collaborate to characterize the chemical species and smoke particles generated by the combustion of current space-rated non-metallic materials including fluoropolymers. This paper describes the results of tests conducted February through September 2012 to identify optimal chemical markers both for augmenting particle-based fire detection methods and for monitoring the post-fire cleanup phase in human spacecraft. These studies follow up on testing conducted in August 2010 and reported at ICES 2011. The tests were conducted at the NASA White Sands Test Facility in a custom glove box designed for burning fractional gram quantities of materials under varying heating profiles. The 623 L chamber was heavily instrumented to quantify organics (gas chromatography/mass spectrometry), inorganics by water extraction followed by ion chromatography, and select species by various individual commercially-available sensors. Evaluating new technologies for measuring carbon monoxide, hydrogen cyanide, hydrogen fluoride, hydrogen chloride and other species of interest was a key objective of the test. Some of these sensors were located inside the glovebox near the fire source to avoid losses through the sampling lines; the rest were located just outside the glovebox. Instruments for smoke particle characterization included a Tapered Element Oscillating Microbalance Personal Dust Monitor (TEOM PDM) and a TSI Dust Trak DRX to measure particle mass concentration, a TSI PTrak for number concentration and a thermal precipitator for collection of particles for microscopic analysis. Materials studied included Nomex(R), M22759 wire insulation, granulated circuit board, polyvinyl chloride (PVC), Polytetrafluoroethylene (PTFE), Kapton(R), and mixtures of PTFE and Kapton(R). Furnace temperatures ranged from 340 to 640 C, focusing on the smoldering regime. Of particular interest in these tests was confirming burn repeatability and production of acid gases with different fuel mixture compositions, as well as the dependence of aerosol concentrations on temperature.

Combustion↗

The oxygen sensitivity/compatibility ranking of several materials by different test methods

Eleven materials were evaluated for oxygen compatibility using the following test methods: heat of combustion (ASTM D 2015), liquid oxygen impact (ASTM D 2512), pneumatic impact (ASTM G 74), gaseous mechanical impact (ASTM G 86), autogenous ignition temperature by pressurized differential scanning calorimeter, and the determination of the 50 percent reaction level in liquid oxygen using silicon carbide as a reaction enhancer. The eleven materials evaluated were: Teflon TFE, Vespel SP-21, Krytox 240AC, Viton PLV5010B, Fluorel E2160, Kel F 81, Fluorogold, Fluorogreen E-600, Rulon A, Garlock 8573, nylon 6/6.

Lockhart, Billy J.↗

Improved precision and accuracy in quantifying plutonium isotope ratios by RIMS

Resonance ionization mass spectrometry (RIMS) holds the promise of rapid, isobar-free quantification of actinide isotope ratios in as-received materials (i.e. not chemically purified). Recent progress in achieving this potential using two Pu test materials is presented. RIMS measurements were conducted multiple times over a period of two months on two different Pu solutions deposited on metal surfaces. Measurements were bracketed with a Pu isotopic standard, and yielded absolute accuracies of the measured Pu-240/Pu-239 ratios of 0.7 and 0.58 %, with precisions (95 % confidence intervals) of 1.49 and 0.91 %. The minor isotope Pu-238 was also quantified despite the presence of a significant quantity of U-238 in the samples.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗