Low-Noise Amplifiers and Superconducting Flex Circuits for Frequency Domain Multiplexed Readout of Detector Arrays

The next-generation ground-based cosmic microwave background (CMB) experimental program aims to provide definitive measurements of the early universe using telescopes configured with large focal plane arrays requiring ~100,000 detectors and associated readout amplifiers and interconnecting components that are currently unavailable commercially. We describe research to demonstrate the feasibility of developing low-noise cryogenic amplifiers based on series SQUID arrays that are suitable for frequency domain multiplexed readout of large numbers of CMB detectors, and the feasibility of developing robust superconducting flex cables that will simplify cryogenic systems integration for large CMB instruments. Two iterations of prototype series SQUID array amplifier designs were completed. The designs were optimized using modeling and simulation tools to meet the requirements for CMB detector readouts. Two fabrication runs were completed, and a large number of devices from each design iteration were tested and characterized at 4 K. We also completed the development of processes for the fabrication of prototype superconducting flex cables on 4" wafers. Samples were tested for strength and robustness, and to determine the critical current at 4 K as a function of trace width. The new generation of series SQUID array amplifier designs exhibit excellent performance characteristics – very smooth output characteristics that simplify tuning and operation, low input inductance, low current noise referred to the input, and low power dissipation that for the first time will enable these devices to be operated at the focal plane array stage of CMB instruments. The processes developed in Phase I to produce superconducting flex cables were used to complete the fabrication of a full wafer with several test and sample flex circuits. The 6-micron thick flex material is very strong with a breaking strength of several pounds for a 20-mm wide strip. Critical current density was reasonable and scaled with trace width as expected.

79 ASTRONOMY AND ASTROPHYSICS↗

Highly Multiplexed Assays for Detection of Biothreat and Food Safety Agents Final Report CRADA No. TC02156.0

This was a collaborative effort between Lawrence Livermore National Security, LLC as manager and operator of Lawrence Livermore National Laboratory (LLNL) and BioSearch Technologies Inc. (BTI) of Novato, California, to develop Multiplexed Molecular Assays for the Rapid and Sensitive Detection of Microbial Agents of Concern for Bioterrorism and Food Safety for the Food and Drug Administration (FDA) Center for Food Safety and Applied Nutrition (CFSAN). There are no outstanding leans for this project.

59 BASIC BIOLOGICAL SCIENCES↗

Modeling Information Multiplexing in the Hippocampus

Modern computers are constantly faced with the challenge of processing ever-growing quantities of data that span a wide range of modalities. Of particular relevance to national security interests is the ability to integrate multimodal data for the purpose of fast decision making. The brain is a biological system that is specialized for high performance at this task, suggesting that understanding the mechanisms by which neural circuits integrate multimodal data may lead to improved man-made detection systems. This research focused on understanding these neural algorithms, and specifically tested the hypothesis that hippocampal neurons multiplex information from two different input streams. Specifically, we compare the spiking behavior of a computational model of hippocampal circuitry with neurophysiological data recorded from rodent hippocampus.

59 BASIC BIOLOGICAL SCIENCES↗

Diagnostic Testing for COVID-19 Bridging Study for CDC EUA assays vs CDC Multiplex N1 FAM, N2 SUN, RNAse P ATTO 647 Assays

This report describes testing performed by LANL’s Biological Agent Testing Laboratory (BATL) to validate modifications to the CDC EUA 2019-Novel Coronavirus (2019-nCoV) Real-Time RT-PCR Diagnostic Panel (EUA-CDC-nCoV-IFU). BATL intends to implement the modification to increase thoughput for daily testing. BATL validated the original component, CDC designed primers and probes purchased from IDT (Cat # 10006770) and the new component, CDC assays designed with new Reporter dyes allowing the assays to be multiplexed, IDT (Cat # 10006830, 10006831, 10006823, 10006833, 10006834, 10007050, 10006836, 10006837, 10007062)

59 BASIC BIOLOGICAL SCIENCES↗

Multiplexed Probing for Functional Capacity Measurements in Complex and Limited-Size Samples

A new strategy using glass as a solid support for functionalization with chemical probes has been recently developed with successful results. The next step in glass functionalization is to pair chemical probes with fluorescent glass microspheres. This approach gives us a way to directly quantify probe-bound protein using Fluorescence-Activated Cell Sorting (FACS). FACS has already shown to be amendable to glass microspheres, demonstrating changes in probe-bound protein concentration. Suitable probing conditions for gram-positive and negative microbes, complex microbial communities from myriad ecosystems, and eukaryotic cells/tissues have traditionally suffered from set-backs, such as limited protein per sample and conditions atypical for probing. To remedy this, we propose to: (1) Demonstrate probe functionalization specific to glass microspheres by paired fluorophore and use those activity probes successfully with proteomics. Probes that are currently available (CYP5, GSH/GST, Glycoside Hydrolase) can be easily prepared onto glass surfaces. Probe-bound microspheres can be tested in ratios, first with known amounts of purified protein and then complex microbiome lysates. (2) Our validated microspheres are then used to determine quantitative amounts of protein through FACS sorting. Complimenting these results by proteomics, prepared microspheres are then optimized and condensed into a user-friendly kit. Once successfully commercialized, this multiplexed assay can be used with little to no technical expertise, making this available to various industries users.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multiplexed Inertial Coalescence Filters for High-Rate Liquid-Gas Chemistry

The aim of this project is to support the development of a disruptive method for deploying liquids in liquid-gas chemical processes to transform carbon dioxide capture from flue gas and ambient air streams. The proposed project is based on the development of a novel filtration method called the Helix MICRA™ (Multiplexed Inertial Coalescence Refining Apparatus) filters. Helix MICRA™ filters are a novel, patented filter that enable high efficiency, low-pressure drop capture of droplet streams. Liquid droplets have a large net-surface area per unit volume and have correspondingly rapid mass transfer rates. By effectively capturing these droplets after deployment, we enable high-rate carbon dioxide capture from air streams unlike any other technology. This project aims at using Helix MICRA™ filters to create efficient and compact carbon dioxide capture systems that would dramatically reduce system size and capital costs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multiplexing core & sheath extrusion system development for additive manufacturing for inner-bead multi-material capability

Single-feed polymer extruders are widely used in large-format additive manufacturing (AM) systems; however, the increasing demand for multi-material functionality within a single part has driven significant innovation in this field. One approach involves robotic pick-and-place operations, while another explores mechanical switching of feed lines during extrusion. Although robotic pick-and-drop systems offer flexibility, they introduce longer layer times during material changes, which can negatively affect the structural integrity of the part. On the other hand, mechanical feed switching causes delays in material transitions, as the existing material must be flushed before the new material emerges from the nozzle. This poses particular challenges for smaller or more intricate parts. In this study we are developing a unique multiplexing extrusion system with core & sheath nozzle that combines two extruders via co-extrusion. This allows for a unique inside and outside inner-bead (i.e., within the same bead) multi-material capability. We believe that this technology will allow for combining neat and filled materials, ductile and stronger materials, and many other combinations to address the problems aforementioned above and disrupt the AM technology creating new opportunities and opening application areas.

Tekinalp, Halil [ORNL]↗

Multiplexed Anodic Stripping Voltammetry Detection of Heavy Metals in Water Using Nanocomposites Modified Screen-Printed Electrodes Integrated With a 3D-Printed Flow Cell

In this study, we present multiplexed anodic stripping voltammetry (ASV) detection of heavy metal ions (HMIs)—As(III), Cd(II), and Pb(II)—using a homemade electrochemical cell consisting of dual working, reference and counter screen-printed electrodes (SPE) on polyimide substrate integrated with a 3D-printed flow cell. Working and counter electrodes were fabricated by the screen-printing of graphite paste while the Ag/AgCl paste was screen-printed as a reference electrode (Ag/AgCl quasi-reference electrode). The working electrodes were modified with (BiO) 2 CO 3 -reduced graphene oxide (rGO)-Nafion [(BiO) 2 CO 3 -rGO-Nafion] and Fe 3 O 4 magnetic nanoparticles (Fe 3 O 4 MNPs) decorated Au nanoparticles (AuNPs)-ionic liquid (IL) (Fe 3 O 4 -Au-IL) nanocomposites separately to enhance HMIs sensing. Electrochemical detection was achieved using square wave ASV technique. The desired structure of the flow electrochemical cell was optimized by the computational fluid dynamic (CFD). Different experimental parameters for stripping analysis of HMIs were optimized including deposition time, deposition potential and flow rate. The linear range of calibration curves with the sensing nanocomposites modified SPE for the three metal ions was from 0–50 μg/L. The limits of detection (S/N = 3) were estimated to be 2.4 μg/L for As(III), 1.2 μg/L for Pb(II) and 0.8 μg/L for Cd(II). Furthermore, the homemade flow anodic stripping sensor platform was used to detect HMIs in simulated river water with a 95–101% recovery, indicating high selectivity and accuracy and great potential for applicability even in complex matrices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-Throughput Microfluidic Electroporation (HTME): A Scalable, 384-Well Platform for Multiplexed Cell Engineering

Electroporation-mediated gene delivery is a cornerstone of synthetic biology, offering several advantages over other methods: higher efficiencies, broader applicability, and simpler sample preparation. Yet, electroporation protocols are often challenging to integrate into highly multiplexed workflows, owing to limitations in their scalability and tunability. These challenges ultimately increase the time and cost per transformation. As a result, rapidly screening genetic libraries, exploring combinatorial designs, or optimizing electroporation parameters requires extensive iterations, consuming large quantities of expensive custom-made DNA and cell lines or primary cells. To address these limitations, we have developed a High-Throughput Microfluidic Electroporation (HTME) platform that includes a 384-well electroporation plate (E-Plate) and control electronics capable of rapidly electroporating all wells in under a minute with individual control of each well. Fabricated using scalable and cost-effective printed-circuit-board (PCB) technology, the E-Plate significantly reduces consumable costs and reagent consumption by operating on nano to microliter volumes. Furthermore, individually addressable wells facilitate rapid exploration of large sets of experimental conditions to optimize electroporation for different cell types and plasmid concentrations/types. Use of the standard 384-well footprint makes the platform easily integrable into automated workflows, thereby enabling end-to-end automation. We demonstrate transformation of E. coli with pUC19 to validate the HTME's core functionality, achieving at least a single colony forming unit in more than 99% of wells and confirming the platform's ability to rapidly perform hundreds of electroporations with customizable conditions. This work highlights the HTME's potential to significantly accelerate synthetic biology Design-Build-Test-Learn (DBTL) cycles by mitigating the transformation/transfection bottleneck.

Gaillard, William R↗

eYGFPuv-Assisted Transgenic Selection in Populus deltoides WV94 and Multiplex Genome Editing in Protoplasts of P. trichocarpa × P. deltoides Clone ‘52-225’

Although CRISPR/Cas-based genome editing has been widely used for plant genetic engineering, its application in the genetic improvement of trees has been limited, partly because of challenges in Agrobacterium-mediated transformation. As an important model for poplar genomics and biotechnology research, eastern cottonwood (Populus deltoides) clone WV94 can be transformed by A. tumefaciens, but several challenges remain unresolved, including the relatively low transformation efficiency and the relatively high rate of false positives from antibiotic-based selection of transgenic events. Moreover, the efficacy of CRISPR-Cas system has not been explored in P. deltoides yet. Here, we first optimized the protocol for Agrobacterium-mediated stable transformation in P. deltoides WV94 and applied a UV-visible reporter called eYGFPuv in transformation. Our results showed that the transgenic events in the early stage of transformation could be easily recognized and counted in a non-invasive manner to narrow down the number of regenerated shoots for further molecular characterization (at the DNA or mRNA level) using PCR. We found that approximately 8.7% of explants regenerated transgenic shoots with green fluorescence within two months. Next, we examined the efficacy of multiplex CRISPR-based genome editing in the protoplasts derived from P. deltoides WV94 and hybrid poplar clone ‘52-225’ (P. trichocarpa × P. deltoides clone ‘52-225’). The two constructs expressing the Trex2-Cas9 system resulted in mutation efficiency ranging from 31% to 57% in hybrid poplar clone 52-225, but no editing events were observed in P. deltoides WV94 transient assay. The eYGFPuv-assisted plant transformation and genome editing approach demonstrated in this study has great potential for accelerating the genome editing-based breeding process in poplar and other non-model plants species and point to the need for additional CRISPR work in P. deltoides.

59 BASIC BIOLOGICAL SCIENCES↗

Resin Assisted Capture Coupled with Isobaric Tandem Mass Tag Labeling for Multiplexed Quantification of Protein Thiol Oxidation

Reversible oxidative modifications on protein thiols have recently emerged as important mediators of cellular function. Herein we describe the detailed procedure of a quantitative redox proteomics method that utilizes resin-assisted capture (RAC) in combination with tandem mass tag (TMT) isobaric labeling and liquid chromatography-tandem mass spectrometry (LC-MS/MS) to allow multiplexed stochiometric quantification of oxidized protein thiols at the proteome level. The site-specific quantitative information on oxidized cysteine residues provides additional insight into the functional impacts of such modifications. The workflow is adaptable across many sample types including cultured cells (e.g. mammalian, prokaryotic) and whole tissues (e.g. heart, lung, muscle) which are initially lysed/homogenized with free thiols being alkylated to prevent artificial oxidation. The oxidized protein thiols are then reduced and captured by a thiol affinity resin which streamlines and simplifies the workflow steps by allowing the proceeding digestion, labeling, and washing procedures to be performed without additional transfer of proteins/peptides. Finally, labeled peptides are eluted and analyzed by LC-MS/MS to reveal comprehensive stoichiometric changes related to thiol oxidation across the entire proteome. This method greatly improves our understanding of the role of redox dependent regulation under physiological and pathophysiological states related to protein thiol oxidation.

RAC, TMT, thiol redox proteomics, cysteine, PTM st↗

MULTIPLEXING PRECISION RVs: SEARCHING FOR CLOSE-IN GAS GIANTS IN OPEN CLUSTERS

We present a multiplexed high-resolution (R ~ 50,000 median) spectroscopic survey designed to detect exoplanet candidates in two southern star clusters (NGC 2516 and NGC 2422) using the Michigan/Magellan Fiber System (M2FS) on the Magellan/Clay telescope at Las Campanas Observatory. With 128 available fibers in our observing mode, we are able to target every star in the core half-degree of each cluster that could plausibly be a solar-analog member. Our template-based spectral fits provide precise measurements of fundamental stellar properties—T eff (±30 K), [Fe/H] and [α/Fe] (±0.02 dex), and v r sin(i) (±0.3 km s -1 )—and radial velocities (RVs) by using telluric absorption features from 7160 to 7290 Å as a wavelength reference for 251 mid-F to mid-K stars (126 in NGC 2516 and 125 in NGC 2422) that comprise our survey. In each cluster, we have obtained ~10–12 epochs of our targets. Using repeat observations of an RV standard star, we show our approach can attain a single-epoch velocity precision of 25–60 m s -1 over a broad range of signal-to-noise ratios throughout our observational baseline of 1.1 years. Our technique is suitable for nonrapidly rotating stars cooler than mid-F. In this paper, we describe our observational sample and analysis methodology and present a detailed study of the attainable precision and measurement capabilities of our approach. Subsequent papers will provide results for stars observed in the target clusters, analyze our data set of RV time series for stellar jitter and stellar and substellar companions, and consider the implications of our findings on the clusters themselves.

79 ASTRONOMY AND ASTROPHYSICS↗

TMTPro Complementary Ion Quantification Increase Plexing and Sensitivity for Accurate Multiplexed Proteomics at the MS2 level

The ability of the TMTPro isobaric labeling reagents to form complementary ions for accurate multiplexed proteomics at the MS2 level was investigated. Human and yeast peptides were labeled in distinct ratios to analyze the effect of interference on the quantification accuracy. A method, TMTProC, was developed and optimized for accurate, sensitive MS2-level quantification of up to 8 conditions in one MS-run.

Stadlmeier, Michael↗

Selection of chromosomal DNA libraries using a multiplex CRISPR system

The directed evolution of biomolecules to improve or change their activity is central to many engineering and synthetic biology efforts. However, selecting improved variants from gene libraries in living cells requires plasmid expression systems that suffer from variable copy number effects, or the use of complex marker-dependent chromosomal integration strategies. We developed quantitative gene assembly and DNA library insertion into the Saccharomyces cerevisiae genome by optimizing an efficient single-step and marker-free genome editing system using CRISPR-Cas9. With this Multiplex CRISPR (CRISPRm) system, we selected an improved cellobiose utilization pathway in diploid yeast in a single round of mutagenesis and selection, which increased cellobiose fermentation rates by over 10-fold. Mutations recovered in the best cellodextrin transporters reveal synergy between substrate binding and transporter dynamics, and demonstrate the power of CRISPRm to accelerate selection experiments and discoveries of the molecular determinants that enhance biomolecule function.

59 BASIC BIOLOGICAL SCIENCES↗

A randomized multiplex CRISPRi-Seq approach for the identification of critical combinations of genes

Identifying virulence-critical genes from pathogens is often limited by functional redundancy. To rapidly interrogate the contributions of combinations of genes to a biological outcome, we have developed a multiplex, randomized CRISPR interference sequencing (MuRCiS) approach. At its center is a new method for the randomized self-assembly of CRISPR arrays from synthetic oligonucleotide pairs. When paired with PacBio long-read sequencing, MuRCiS allowed for near-comprehensive interrogation of all pairwise combinations of a group of 44 Legionella pneumophila virulence genes encoding highly conserved transmembrane proteins for their role in pathogenesis. Both amoeba and human macrophages were challenged with L. pneumophila bearing the pooled CRISPR array libraries, leading to the identification of several new virulence-critical combinations of genes. lpg2888 and lpg3000 were particularly fascinating for their apparent redundant functions during L. pneumophila human macrophage infection, while lpg3000 alone was essential for L. pneumophila virulence in the amoeban host Acanthamoeba castellanii. Thus, MuRCiS provides a method for rapid genetic examination of even large groups of redundant genes, setting the stage for application of this technology to a variety of biological contexts and organisms.

79 ASTRONOMY AND ASTROPHYSICS↗

Microphone multiplex system provides multiple outlets from single source

Microphone multiplex system accepts an audio signal from a single source and provides any number of low impedance outputs at microphone level with complete isolation between output channels. Any input or output may be converted to high impedance by eliminating the associated transformer.

Lauver, R. E.↗

Multiplexer uses insulated gate-field effect transistors

Small lightweight multiplexer incorporates IG-FETs /Insulated Gate-Field Effect Transistors/ for all digital logic functions, including the internally generated 3.6-kHz clock. It consists of 30 primary channels, each of which is sampled 120 times per second.

Gussow, S. S.↗