Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MICROSPHERES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

MO-G-17A-06: Kernel Based Dosimetry for 90Y Microsphere Liver Therapy Using 90Y Bremsstrahlung SPECT/CT

Purpose: 90Y microsphere therapy in liver presents a situation where beta transport is dominant and the tissue is relatively homogenous. We compare voxel-based absorbed doses from a 90Y kernel to Monte Carlo (MC) using quantitative 90Y bremsstrahlung SPECT/CT as source distribution. Methods: Liver, normal liver, and tumors were delineated by an interventional radiologist using contrast-enhanced CT registered with 90Y SPECT/CT scans for 14 therapies. Right lung was segmented via region growing. The kernel was generated with 1.04 g/cc soft tissue for 4.8 mm voxel matching the SPECT. MC simulation materials included air, lung, soft tissue, and bone with varying densities. We report percent difference between kernel and MC (%Δ(K,MC)) for mean absorbed dose, D70, and V20Gy in total liver, normal liver, tumors, and right lung. We also report %Δ(K,MC) for heterogeneity metrics: coefficient of variation (COV) and D10/D90. The impact of spatial resolution (0, 10, 20 mm FWHM) and lung shunt fraction (LSF) (1,5,10,20%) on the accuracy of MC and kernel doses near the liver-lung interface was modeled in 1D. We report the distance from the interface where errors become <10% of unblurred MC as d10(side of interface, dose calculation, FWHM blurring, LSF). Results: The %Δ(K,MC) for mean, D70, and V20Gy in tumor and liver was <7% while right lung differences varied from 60–90%. The %Δ(K,MC) for COV was <4.8% for tumor and liver and <54% for the right lung. The %Δ(K,MC) for D10/D90 was <5% for 22/23 tumors. d10(liver,MC,10,1–20) awere <9mm and d10(liver,MC,20,1–20) awere <15mm; both agreed within 3mm to the kernel. d10(lung,MC,10,20), d10(lung,MC,10,1), d10(lung,MC,20,20), and d10(lung,MC,20,1) awere 6, 25, 15, and 34mm, respectively. Kernel calculations on blurred distributions in lung had errors > 10%. Conclusions: Liver and tumor voxel doses with 90Y kernel and MC agree within 7%. Large differences exist between the two methods in right lung. Research reported in this publication was supported by the National Cancer Institute of the National Institutes of Health under Award Number R01CA138986. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health.

60 APPLIED LIFE SCIENCES↗

Wavefront aberration measurements and corrections through thick tissue using fluorescent microsphere reference beacons

We present a new method to directly measure and correct the aberrations introduced when imaging through thick biological tissue. A Shack-Hartmann wavefront sensor is used to directly measure the wavefront error induced by a Drosophila embryo. The wavefront measurements are taken by seeding the embryo with fluorescent microspheres used as “artificial guide-stars.” The wavefront error is corrected in ten millisecond steps by applying the inverse to the wavefront error on a micro-electromechanical deformable mirror in the image path of the microscope. The results show that this new approach is capable of improving the Strehl ratio by 2 times on average and as high as 10 times when imaging through 100 µm of tissue. The results also show that the isoplanatic half-width is approximately 19 µm resulting in a corrected field of view 38 µm in diameter around the guide-star.

59 BASIC BIOLOGICAL SCIENCES↗

Holographic optical assembly and photopolymerized joining of planar microspheres

The aim of this research is to demonstrate a holographically driven photopolymerization process for joining colloidal particles to create planar microstructures fixed to a substrate, which can be monitored with real-time measurement. Holographic optical tweezers (HOT) have been used to arrange arrays of microparticles prior to this work; here we introduce a new photopolymerization process for rapidly joining simultaneously handled microspheres in a plane. Additionally, we demonstrate a new process control technique for efficiently identifying when particles have been successfully joined by measuring a sufficient reduction in the particles’ Brownian motion. Furthermore, this technique and our demonstrated joining approach enable HOT technology to take critical steps toward automated additive fabrication of microstructures.

36 MATERIALS SCIENCE↗

Research to develop and test an advanced Resorbable Brachytherapy seed research for controlled delivery of Yttrium-99 microspheres in cancer treatment

The Y-90 Brachytherapy Seed is a small, cylindrical source of therapeutic radiation for controlled delivery of localized therapeutic radiation to cancerous tissue. The Y-90 Brachytherapy Seed consists of microscopic inorganic particles of highly insoluble yttrium phosphate containing the beta-emitting radionuclide Y-90, gold particles, and an encapsulating bio-absorbable polymer-matrix material. The polymer matrix is formed in a cylindrical shape to contain the yttrium phosphate microspheres and gold x-ray marker particles.

07 ISOTOPE AND RADIATION SOURCES↗

Modeling Continuous-Flow Reactor Improvements over Batch Reactions for Enzyme Catalyzed Microsphere Surface Reactions

Our research objective was to study enzymatic reactions occurring on microsphere surfaces. Specifically, our work involved enzymatic polymerization reactions (chain lengthening) taking place both in batch and in a continuous flow reactor. My research involved creating simulations using COMSOL Multiphysics 5.4a to further study variable interactions within the continuous flow reactor. Our goal was to use suitable software to create a simulation platform suite that could be used for advanced research studies of continuous flow enzymatic surfaces reactions. In addition, we studied various characteristics of our present enzymatic polymerization reactor assembly, modeled inlet species flow (Species M) and estimated outlet species production (Species P). Our simulations spanned three levels of detail: Single-Bead, Packed-Bead Cell and Full Reactor Column. Furthermore, the Packed-Bead Cells were studied using three possible regular arrangement of solid spheres: Face-Centered Cubic (FCC), Hexagonal Close Packed (HCP) and Cubic Close Packed (CCP).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of CT-derived Ventilation Maps with Deposition Patterns of Inhaled Microspheres in Rats

Purpose: Computer models for inhalation toxicology and drug-aerosol delivery studies rely on ventilation pattern inputs for predictions of particle deposition and vapor uptake. However, changes in lung mechanics due to disease can impact airflow dynamics and model results. It has been demonstrated that non-invasive, in vivo, 4DCT imaging (3D imaging at multiple time points in the breathing cycle) can be used to map heterogeneities in ventilation patterns under healthy and disease conditions. The purpose of this study was to validate ventilation patterns measured from CT imaging by exposing the same rats to an aerosol of fluorescent microspheres (FMS) and examining particle deposition patterns using cryomicrotome imaging. Materials and Methods: Six male Sprague-Dawley rats were intratracheally instilled with elastase to a single lobe to induce a heterogeneous disease. After four weeks, rats were imaged over the breathing cycle by CT then immediately exposed to an aerosol of ~1µm FMS for ~5 minutes. After the exposure, the lungs were excised and prepared for cryomicrotome imaging, where a 3D image of FMS deposition was acquired using serial sectioning. Cryomicrotome images were spatially registered to match the live CT images to facilitate direct quantitative comparisons of FMS signal intensity with the CT-based ventilation maps. Results: Comparisons of fractional ventilation in contiguous, non-overlapping, 3D regions between CT-based ventilation maps and FMS images showed strong correlations in fractional ventilation (r=0.888, p<0.0001). Conclusion: We conclude that ventilation maps derived from CT imaging are predictive of the 1µm aerosol deposition used in ventilation-perfusion heterogeneity inhalation studies.

Jacob, Rick E.↗

Potentiometric Response Characteristics of Membrane-Based Cs + -Selective Electrodes Containing Ionophore-Functionalized Polymeric Microspheres

Cs + -selective solvent polymeric membrane-based ion-selective electrodes (ISEs) were developed by doping ethylene glycol-functionalized cross-linked polystyrene microspheres (P-EG) into a plasticized poly(vinyl chloride) (PVC) matrix containing sodium tetrakis-(3,5-bis(trifluoromethyl)phenyl) borate (TFPB) as the ion exchanger. A systematic study examining the effects of the membrane plasticizers bis(2-ethylhexyl) sebacate (DOS), 2-nitrophenyl octyl ether (NPOE), and 2-fluorophenyl nitrophenyl ether (FPNPE) on the potentiometric response and selectivity of the corresponding electrodes was performed. Under certain conditions, P-EG-based ion-selective electrodes (ISEs) containing TFPB and plasticized with NPOE exhibited a super-Nernstian response between 1 × 10 − 3 and 1 × 10 − 4 M Cs + , a response characteristic not observed in analogous membranes plasticized with either DOS or FPNPE. Additionally, the performance of P-EG-based ISEs was compared to electrodes based on two mobile ionophores, a neutral lipophilic ethylene glycol derivative (ethylene glycol monooctadecyl ether (U-EG)) and a charged metallacarborane ionophore, sodium bis(dicarbollyl)cobaltate(III) (CC). In general, P-EG-based electrodes plasticized with FPNPE yielded the best performance, with a linear range from 10 -1 –10 -5 M Cs + , a conventional lower detection limit of 8.1 × 10 − 6 M Cs + , and a response slope of 57.7 mV/decade. The pH response of P-EG ISEs containing TFPB was evaluated for membranes plasticized with either NPOE or FPNPE. In both cases, the electrodes remained stable throughout the pH range 3–12, with only slight proton interference observed below pH 3.

Peper, Shane↗

Fluorescent microspheres

Latex particles with attached antibodies have potential biochemical and environmental applications. Human red blood cells and lymphocytes have been labeled with fluorescent microspheres by either direct or indirect immunological technique. Immunolatex spheres can also be used for detecting and localizing specific cell surface receptors. Hormones and toxins may also be bondable.

Rembaum, A.↗

Electrophoretic cell separation using microspheres

Methods of cell separation based on the electrokinetic properties of the cell membrane offer a degree of discrimination among cell populations which is not available with methods based on cell size or density alone. Studies aimed at extending red cell separations using microspheres to purification of lymphocytes.

Smolka, A.↗

Evaluation of the Separability of Monodisperse Polystyrene Latex Microspheres in a Continuous Flow Electrophoresis System

The continuous flow electrophoresis system makes electrophoresis possible in a free flowing film of aqueous electrolyte medium. The sample is introduced at one end of the chamber and is subjected to a lateral dc field. This process separates the sample into fractions since each component has a distinctive electrophoric mobility. Evaluations were made of sample conductivity and buffer conductivity as they affect sample band spread and separation using the Continuous Particle Electrophoresis (CPE) system. Samples were prepared from mixtures of 5 percent and 1 percent polystyrene latex (PSL) microspheres which were .4, .56 and .7 microns in diameter. These were prepared in electrolyte media 1x and 3x the conductivity of the curtain buffer, approximately 150 and 450 micro mhos/cm. Samples with matched conductivities produced greater resolution and less band spread than those with 3x the conductivity of the curtain buffer.

Williams, G., Jr.↗

Making Latex Microspheres in Space

Equipment yields larger, more uniform particles. Two NASA reports describe first commercial product to be manufactured in space. Product monodisperse latex, suspension of spherical particles of essentially same diameter. Carried aboard Space Shuttle on its orbital missions, monodisperse latex reactor (MLR) produces spheres of much larger size than possible on Earth. Mircospheres 30 micrometers in diameter produced, whereas 5 micrometers is limit for Earthbound reactors. Microspheres as large as 100 micrometers scheduled for production in MLR.

Kornfeld, D. M.↗

Containerless polymeric microsphere production for biomedical applications

A containerless method that produces highly uniform microspheres (greater than 50 microns in diameter) from many materials has been developed for biomedical applications. A piezoelectrically vibrated drop generator forms uniform (monodisperse) monomer droplets that are either electrostatistically levitated and polymerized using UV irradiation, or free-radical polymerized. Spheres of 2-hydroxyethyl methacrylate polymer have been produced with diameters of 155 microns + or - 1.57 percent.

Rhim, W. K.↗

Nonaggregating Microspheres Containing Aldehyde Groups

Cobalt gamma irradiation of hydrophilic monomers in presence of acrolein yields exceptionally-stable, nonaggregating microspheres. Mixtures of 2-hydroxyethyl methacrylate (HEMA) and acrolein form homogeneous solutions in distilled water containing 0.4 percent polyethylene oxide (PEO). After deaeration with nitrogen, mixtures irradiated at room temperature with gamma rays from cobalt source; total exposure time 4 hours, at rate of 0.2 milliroentgen per hour. Reaction product centrifuged three times for purification and kept in distilled water.

Rembaum, Alan↗

Coulomb Crystallization of Charged Microspheres Levitated in a Gas Discharge Plasma

The technical topic of the project was the experimental observation of Coulomb crystallization of charged microspheres levitated in a gas discharge plasma. This suspension, sometimes termed a dusty plasma, is closely analogous to a colloidal suspension, except that it has a much faster time response, is more optically thin, and has no buoyancy forces to suspend the particles. The particles are levitated by electric fields. Through their collective Coulomb repulsions, the particles arrange themselves in a lattice with a crystalline symmetry, which undergoes an order-disorder phase transition analogous to melting when the effective temperature of the system is increased. Due to gravitational sedimentation, the particles form a thin layer in the laboratory, so that the experimental system is nearly 2D, whereas in future microgravity experiments they are expected to fill a larger volume and behave like a 3D solid or liquid. The particles are imaged using a video camera by illuminating them with a sheet of laser light. Because the suspension is optically thin, this imaging method will work as well in a 3D microgravity experiment as it does in a 2D laboratory system.

Goree, John↗