Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MASS RESOLUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Remote Sensing of Icy Galilean Moon Surface and Atmospheric Composition Using Low Energy (1 eV-4 keV) Neutral Atom Imaging

We describe a low energy neutral atom imager suitable for composition measurements Europa and other icy Galilean moons in the Jovian magnetosphere. This instrument employs conversion surface technology and is sensitive to either neutrals converted to negative ions, neutrals converted to positive ions and the positive ions themselves depending on the power supply. On a mission such as the Jupiter Icy Moons Orbiter (JIMO), two back-to-back sensors would be flown with separate power supplies fitted to the neutral atom and iodneutral atom sides. This will allow both remote imaging of 1 eV < E < 4 keV neutrals from icy moon surfaces and atmospheres, and in situ measurements of ions at similar energies in the moon ionospheres and Jovian magnetospheric plasma. The instrument provides composition measurements of the neutrals and ions that enter the spectrometer with a mass resolution dependent on the time-of-flight subsystem and capable of resolving molecules. The lower energy neutrals, up to tens of eV, arise from atoms and molecules sputtered off the moon surfaces and out of the moon atmospheres by impacts of more energetic (keV to MeV) ions from the magnetosphere. Direct Simulation Monte Carlo (DSMC) models are used to convert measured neutral abundances to compositional distributions of primary and trace species in the sputtered surfaces and atmospheres. The escaping neutrals can also be detected as ions after photo- or plasma-ionization and pickup. Higher energy, keV neutrals come from charge exchange of magnetospheric ions in the moon atmospheres and provide information on atmospheric structure. At the jovicentric orbits of the icy moons the presence of toroidal gas clouds, as detected at Europa's orbit, provide M e r opportunities to analyze both the composition of neutrals and ions originating from the moon surfaces, and the characteristics of magnetospheric ions interacting with neutral cloud material. Charge exchange of low energy ions near the moons, and directional distributions of the resultant neutrals, allow indirect global mapping of magnetic field structures around the moons. Temporal variation of the magnetic structures can be linked to induced magnetic fields associated with subsurface oceans.

Collier, M. R.↗

Wind and Temperature Spectrometry of the Upper Atmosphere in Low-Earth Orbit

Wind and Temperature Spectrometry (WATS) is a new approach to measure the full wind vector, temperature, and relative densities of major neutral species in the Earth's thermosphere. The method uses an energy-angle spectrometer moving through the tenuous upper atmosphere to measure directly the angular and energy distributions of the air stream that enters the spectrometer. The angular distribution gives the direction of the total velocity of the air entering the spectrometer, and the energy distribution gives the magnitude of the total velocity. The wind velocity vector is uniquely determined since the measured total velocity depends on the wind vector and the orbiting velocity vector. The orbiting spectrometer moves supersonically, Mach 8 or greater, through the air and must point within a few degrees of its orbital velocity vector (the ram direction). Pointing knowledge is critical; for example, pointing errors 0.1 lead to errors of about 10 m/s in the wind. The WATS method may also be applied without modification to measure the ion-drift vector, ion temperature, and relative ion densities of major ionic species in the ionosphere. In such an application it may be called IDTS: Ion-Drift Temperature Spectrometry. A spectrometer-based coordinate system with one axis instantaneously pointing along the ram direction makes it possible to transform the Maxwellian velocity distribution of the air molecules to a Maxwellian energy-angle distribution for the molecular flux entering the spectrometer. This implementation of WATS is called the gas kinetic method (GKM) because it is applied to the case of the Maxwellian distribution. The WATS method follows from the recognition that in a supersonic platform moving at 8,000 m/s, the measurement of small wind velocities in the air on the order of a few 100 m/s and less requires precise knowledge of the angle of incidence of the neutral atoms and molecules. The same is true for the case of ion-drift measurements. WATS also provides a general approach that can obtain non-equilibrium distributions as may exist in the upper regions of the thermosphere, above 500 km and into the exosphere. Finally, WATS serves as a mass spectrometer, with very low mass resolution of roughly 1 part in 3, but easily separating atomic oxygen from molecular nitrogen.

Herrero, Federico↗

Laser Ablation Mass Spectrometer (LAMS) as a Standoff Analyzer in Space Missions for Airless Bodies

A laser ablation mass spectrometer (LAMS) based on a time-of-flight (TOF) analyzer with adjustable drift length is proposed as a standoff elemental composition sensor for space missions to airless bodies. It is found that the use of a retarding potential analyzer in combination with a two-stage reflectron enables LAMS to be operated at variable drift length. For field-free drift lengths between 33 cm to 100 cm, at least unit mass resolution can be maintained solely by adjustment of internal voltages, and without resorting to drastic reductions in sensitivity. Therefore, LAMS should be able to be mounted on a robotic arm and analyze samples at standoff distances of up to several tens of cm, permitting high operational flexibility and wide area coverage of heterogeneous regolith on airless bodies.

Li, X.↗

Precision Oxygen Isotope Measurements of Two C-Rich Hydrated Interplanetary Dust Particles

Introduction: Chondritic-smooth IDPs (Interplanetary Dust Particles) are low porosity objects whose mineralogy is dominated by aqueous alteration products such as Mg-rich phyllosilicates (smectite and serpentine group) and Mg-Fe carbonate minerals. Their hydrated mineralogy combined with low atmospheric entry velocities have been used to infer an origin largely from asteroidal sources. Spectroscopic studies show that the types and abundance of organic matter in CS IDPs is similar to that in CP IDPs. Although CS IDPs show broad similarities to primitive carbonaceous chondrites, only a few particles have been directly linked to specific meteorite groups such as CM and CI chondrites based on the presence of diagnostic minerals. Many CS IDPs however, have carbon contents that greatly exceed that of known meteorite groups suggesting that they either may derive from comets or represent samples of more primitive parent bodies than do meteorites. It is now recognized that many large, dark primitive asteroids in the outer main belt, as well as some trans-Neptunian objects, show spectroscopic evidence for aqueous alteration products on their surfaces. Some CS IDPs exhibit large bulk D enrichments similar to those observed in the cometary CP IDPs. While hydrated minerals in comets have not been unambiguously identified to date, the presence of the smectite group mineral nontronite has been inferred from infrared spectra obtained from the ejecta from comet 9P/Tempel 1 during the Deep Impact mission. Recent observations of low temperature sulfide minerals in Stardust mission samples suggest that limited aqueous activity occurred on comet Wild-2. All of these observations, taken together, suggest that the high-carbon hydrated IDPs are abundant and important samples of primitive solar system objects not represented in meteorite collections. Oxygen isotopic compositions of chondrites reflect mixing between a 16O-rich reservoir and a 17O,18O-rich reservoir produced via mass-independent fractionation. The composition of the 16O-rich reservoir is well constrained but material representing the 17O,18O-rich end-member is rare. Self-shielding models predict that cometary water, presumed to represent this reservoir, should be enriched in 17O and 18O by greater than 200 per mille. The high-carbon hydrated IDPs may be among the best materials available to search for preserved "cometary" H2O signatures. In order to better understand the origin and evolution of these particles, we have obtained 10 hydrated interplanetary dust particles for coordinated mineralogical, isotopic and organic analyses. We have previously reported the results of mineralogical and O isotopic measurements of two hydrated IDPs; here we present results of O isotopic measurements of three additional IDPs. Samples and Methods: Three interplanetary dust particles (L2079C35, L2083D46 and L2083E46) were embedded in S and partially ultramicrotomed into approximately 70 nanometer sections for analysis via transmission electron microscopy (TEM). The remainders of the unsliced particles were removed from S and pressed into high purity Au foil that was cleaned with HF acid and annealed at 800 degrees Centigrade. The pressed IDPs were analyzed via electron microprobe analysis (EPMA) for quantitative bulk chemical analysis. After EPMA analysis, the IDPs were subjected to precision O isotope analysis with the UCLA Cameca IMS-1270 ion probe. A 20 kiloelectronvolt, 0.5 nanoangstrom Cs+ primary beam of approximately 15 micrometers diameter was used for each measurement. Small particles of San Carlos olivine and Burma spinel were pressed into the Au foil for use as standards to correct for instrumental mass fractionation. The detection system was configured for multicollection, with 16O measured on a Faraday cup, and 17O and 18O measured on electron multipliers (EMs). Individual analyses consisted of 15 cycles of 10 seconds per cycle. Additionally, two microtome thin sections were measured for H isotopic compositions with the JSC NanoSIMS 50L ion probe. An 8 picoangstrom, 16 kiloelectronvolt Cs plus primary beam was used. Measurements consisted of H, C, 12C, 16O, and 18O collected with EMs in multicollection. Terrestrial biotite and kerogen were used for isotopic standards. A significant challenge in O isotope measurement of hydrated minerals is the interference from 16OH at mass 17O. We ensured that the 17O and 16OH peaks were fully resolved by using a mass resolution of greater than 7000 and by careful analyses of San Carlos olivine, Burma spinel and chlorite hydrated mineral standards. The hydride was further suppressed with a cold finger attached to an LN2 dewar to trap volatiles in the sample chamber. All sputtered ions were counted (i.e. presputtering was not used); after applying background, yield and deadtime corrections, we performed a change-point analysis on our data via R in order to determine when the sample reached sputtering equilibrium; data points collected prior to the change point were excluded. Change-point analysis was also used to determine whether the IDP had completely sputtered. Results: Mineralogy. IDPs C35 and E46 exhibited hydrated mineralogies, Fe-Ni sulfide grains, nanoglobules and occasional enstatite grains distributed throughout a fine-grained Mg-Fe saponite matrix. C35 also contained breunnerite (Mg,Fe)CO3; solar flare tracks were observed in enstatite, indicating minimal atmospheric entry heating. The mineralogy of D46 is dominated by a large FeS grain with a minor component of adhering silicate material. D46 was strongly heated during atmorpheric entry as evidenced by a well-developed magnetite rim. EPMA analyses show that both C35 and E46 have high carbon contents of 20 weight percentage (approximately 6X CI). D46 contains approximately 6 wt.weight percentage C. A significant amount of the carbon is present as carbon nanoglobules. Results: Hydrogen isotopes: Although the bulk delta D values of both sections of L2079C35 were within error of SMOW (minus 33 plus or minus 19 per mille, 1 plus or minus 14 per mille 1 sigma), several delta D-rich hotspots were also identified, reaching 2000 per mille. As shown in Fig. 1, these hotspots are clearly associated with discrete carbonaceous inclusions that are akin to nanoglobules found in many meteorites and other IDPs. Oxygen Isotopes. Results of the oxygen isotope measurements are shown in Figure 1. The oxygen isotope composition for L2079C35 was delta 18O equals plus11.6 plus or minus 1.9per mille, delta 17O equals plus 7.9 plus or minus 1.9per mille (2 standard errors). The oxygen isotope composition for L2083D46 was delta 18O equals minus 8.1 plus or minus 1.9 per mille, delta 17O equals minus 6.4 plus or minus 3.1 per mille (2 standard errors). The oxygen isotope composition for L2083E46 was delta 18O equals plus 12.0 plus or minus 1.9 per mille, delta 17O equals plus 9.2 plus or minus 2.0 per mille (2 standard errors). Discussion: Despite mineralogical similarities to highly aqueously altered carbonaceous chondrites, the hydrated IDPs we analyzed have oxygen isotopic compositions that are distinct from matrix materials in the CI, CM, and CR chondrites. The IDPs plot along the Young-Russell line, with delta 17O values for C35 and E46 suggestive of interaction with a 16O-poor reservoir. However, we have thus far not observed evidence of extreme 16O-poor reservoirs expected from self-shielding models and observed in Acfer 094 simplectite. The high carbon contents of the IDPs also set them apart from known meteoritic samples. The lack of atmospheric entry heating effects are consistent with low encounter velocities and suggest either an asteroidal source, or a low inclination, low eccentricity cometary origin. Conclusions: The unusual oxygen isotopic compositions, high carbon contents, and the abundance of Drich nanoglobules, together, suggest that the high-carbon, hydrated IDPs are derived from a primitive source that is not yet represented in meteorite collections.

Snead, C. J.↗

Chromophores from photolyzed ammonia reacting with acetylene: Application to Jupiters Great Red Spot

The high altitude of Jupiter's Great Red Spot (GRS) may enhance the upward flux of gaseous ammonia (NH3 ) into the high troposphere, where NH3 molecules can be photodissociated and initiate a chain of chemical reactions with downwelling acetylene molecules (C2H2 ). These reactions, experimentally studied earlier by (Ferris and Ishikawa [1987] Nature 326, 777-778) and (Ferris and Ishikawa [1988] J. Amer. Chem. Soc. 110, 4306-4312), produce chromophores that absorb in the visible and ultraviolet regions. In this work we photolyzed mixtures of NH3 and C2H2 using ultraviolet radiation with a wavelength of 214 nm and measured the spectral transmission of the deposited films in the visible region (400-740 nm). From these transmission data we estimated the imaginary indices of refraction. Assuming that ammonia grains at the top of the GRS clouds are coated with this material, we performed layered sphere and radiative transfer calculations to predict GRS reflection spectra. Comparison of those results with observed and previously unreported Cassini visible spectra and with true-color images of the GRS show that the unknown GRS chromophore is spectrally consistent with the coupled NH3-C2H2 photochemical products produced in our laboratory experiments. Using high-resolution mass spectrometry and infrared spectroscopy we infer that the chromophore-containing residue is composed of aliphatic azine, azo, and diazo compounds.

Jupiter↗

Sylph: Life Detection Probe for a Europa Plume

Jupiter’s Galilean satellite Europa likely contains a vast, global, subsurface salt-water ocean. A singular telescope observation in 2012 indicated possible plume activity, in some ways similar to the continuous plume activity seen at Enceladus. If a Europan plume does expel ocean water into space, its vapor, ice grains, and dust grains could be analyzed by a spacecraft equipped with high-resolution mass spectrometers. Such plume measurements would be sufficient to measure the contextual habitability profile of the ocean, and to detect multiple signatures of life, should it exist in the ocean. Instrumented with MASPEX (Mass Spectrometer for Planetary Exploration) and SUDA (Surface Dust Analyzer), NASA’s planned Europa Mission now in development could theoretically conduct this investigation. However, the mission’s closest flyby altitude would be 25 km; due to Europa’s large gravity, frozen ocean spray containing non-volatile molecular species critical to biosignature detection can be sampled only within 5 km of the surface. The Europa Mission would not fly this low. Sylph is a concept for a complementary, free-flyer smallsat probe, about the same size as an office water-cooler bottle, that could be deployed by the Europa Mission as it conducts a plume fly-through. Sylph would execute a single ~2 km altitude plume pass below the main spacecraft. With a mass of 40 kg and a 24-hr life, the probe would autonomously navigate its low-altitude pass, and carry a dualchannel Mini-SUDA impact ionization mass spectrometer that would measure the composition of large grains, complementing the main spacecraft’s measurements of small grains and gas. Sylph is a novel smallsat concept: purpose-built configuration optimized for both the harsh Jovian environment and for Europan planetary-protection requirements, and built with advanced manufacturing methods from both deep space and smallsat components. For $80M (~4% marginal cost), the Europa Mission could buy a Sylph “insurance policy,” hedging the possibility that it does discover ocean plumes upon arrival in 2028. At less than 85 kg for probe and accommodations, the mission could carry two or three of the probes.

Sherwood, Brent↗

A Search for Butane in Titan’s Atmosphere using Cassini CIRS Infrared Spectra

The atmosphere of Saturn’s moon, Titan, is unlike any other. Photochemistry and ion chemistry in the upper atmosphere process the major atmospheric constituents, molecular nitrogen (N2) and methane (CH4), into larger and more complex molecules including hydrocarbons and nitriles. To date there are ten hydrocarbons heavier than methane that have been detected, including large quantities of the saturated hydrocarbons (alkanes) ethane (C2H6) and propane (C3H8). In addition to being significant trace gases of the atmosphere, these species condense, rain out and add to the volume of Titan’s hydrocarbon lakes and seas. The fourth lightest alkane, butane (C4H10),comes in two structural forms: an unbranched carbon chain (n-butane) and a branched chain (i-butane). The relative production rates of both these isomers are presently unknown, although the circumstantial case for butane to be present in detectable amounts is strong, based on photochemical models and from Cassini low-resolution mass spectrometry of the ionosphere. Butane, like its lighter siblings ethane and propane, is thought to be present in Titan’s lakes and seas where it may be active in forming molecular ‘co-crystals’ with acetylene (C2H2). We report on our recent attempts to detect both forms of butane in Titan’s atmosphere by analysis of Cassini infrared spectra collected during 2004-2017 by the Composite Infrared Spectrometer(CIRS) instrument. This multi-year effort has encompassed the collection of new laboratory spectra of both isomers at several institutions, followed by a concerted attempt to find their signatures in CIRS spectra. We search for butane by high precision modeling and removal of overlying emissions due to other, already-known gases to reveal signatures that match those of the butane isomers. The current status of the search will be discussed, including improved upper limits for both isomers, and directions of future research to detect both species.

Conor Nixon↗

PAHs, Hydrocarbons, and Dimethylsulfides in Asteroid Ryugu Samples A0106 and C0107 and the Orgueil (CI1) Meteorite

Evaluating the molecular distribution of organic compounds in pristine extraterrestrial materials is cornerstone to understanding the abiotic synthesis of organics and allows us to better understand the molecular diversity available during the formation of our solar system and before the origins of life on Earth. In this work we identify multiple organic compounds in solvent extracts of asteroid Ryugu samples A0106 and C0107 and the Orgueil meteorite using two-dimensional gas chromatography and time-of-flight high resolution mass spectrometry (GC×GC-HRMS). Our analyses found similarities between the molecular distribution of organic compounds in Ryugu and the CI carbonaceous chondrite Orgueil. Specifically, several PAHs and organosulfides were found in Ryugu and Orgueil suggesting an interstellar and parent body origin for these compounds. We also evaluated the common relationship between Ryugu, Orgueil, and comets like Wild-2; however, until comprehensive compound-specific isotopic analyses for these organic species are undertaken, and until the effects of parent body processes and Earth’s weathering processes on meteoritic organics are better understood, their parent-daughter relationships will remain unanswered. Finally, the study of organic compounds in Ryugu samples and the curation practices for the future preservation of these unvaluable materials are also of special interest for future sample return missions, including NASA’s OSIRIS-REx asteroid sample return mission.

Hayabusa2↗

Extraterrestrial Amino Acids and Amines Identified in Asteroid Ryugu Samples Returned By the Hayabusa2 Mission

The hot water and acid extracts of two different Ryugu samples collected by the Hayabusa2 mission were analyzed for the presence of aliphatic amines and amino acids. The abundances and relative distributions of both classes of molecules were determined, as well as the enantiomeric compositions of the chiral amino acids. The Ryugu samples studied here were recovered from sample chambers A and C, which were composed of surface material, and a combination of surface and possible subsurface material, respectively. A total of thirteen amino acids were detected and quantitated in these samples, with an additional five amino acids that were tentatively identified but not quantitated. The abundances of four aliphatic amines identified in the Ryugu samples were also determined in the current work. Amino acids were observed in the acid hydrolyzed and unhydrolyzed hot water extracts of asteroid Ryugu regolith using liquid chromatography with UV fluorescence detection and high-resolution mass spectrometry. Conversely, aliphatic amines were only analyzed in the unhydrolyzed hot water Ryugu extracts. Two- to six-carbon (C 2 -C 6 ) amino acids with individual abundances ranging from 0.02 to 15.8 nmol g −1 , and one- to three-carbon (C 1 -C 3 ) aliphatic amines with individual abundances from 0.05 to 34.14 nmol g −1 , were found in the hot water extracts. Several non-protein amino acids that are rare in biology, including β-amino-n-butyric acid (β-ABA) and β-aminoisobuytric acid (β-AIB), were racemic or very nearly racemic, thus indicating their likely abiotic origins. Trace amounts of select protein amino acids that were enriched in the ւ-enantiomer may indicate low levels of terrestrial amino acid contamination in the samples. However, the presence of elevated abundances of free and racemic alanine, a common protein amino acid in terrestrial biology, and elevated abundances of the predominately free and racemic non-protein amino acids, β-ABA and β-AIB, indicate that many of the amino acids detected in the Ryugu water extracts were indigenous to the samples. Although the Ryugu samples have been found to be chemically similar to CI type carbonaceous chondrites, the measured concentrations and relative distributions of amino acids and aliphatic amines in Ryugu samples were notably different from those previously observed for the CI1.1 carbonaceous chondrite, Orgueil. This discrepancy could be the result of differences in the original chemical compositions of the parent bodies and/or alteration conditions, such as space weathering. In addition to α-amino acids that could have been formed by Strecker cyanohydrin synthesis during a low temperature aqueous alteration phase, β-, γ-, and δ-amino acids, including C 3 – C 5 straight-chain n-ω-amino acids that are not formed by Strecker synthesis, were also observed in the Ryugu extracts. The suite of amino acids measured in the Ryugu samples indicates that multiple amino acid formation mechanisms were active on the Ryugu parent body. The analytical techniques used here are well-suited to search for similar analytes in asteroid Bennu material collected by the NASA OSIRIS-REx mission scheduled for Earth return in September 2023.

Hayabusa2↗

The Spatial Distribution of Soluble Organic Matter and Their Relationship to Minerals in the Asteroid (162173) Ryugu

We performed in-situ analysis on a ~1 mm-sized grain A0080 returned by the Hayabusa2 spacecraft from near-Earth asteroid (162173) Ryugu to investigate the relationship of soluble organic matter (SOM) to minerals. Desorption electrospray ionization-high resolution mass spectrometry (DESI-HRMS) imaging mapped more than 200 CHN, CHO, CHO–Na (sodium adducted), and CHNO soluble organic compounds. A heterogeneous spatial distribution was observed for different compound classes of SOM as well as among alkylated homologues on the sample surface. The A0080 sample showed mineralogy more like an Ivuna-type (CI) carbonaceous chondrite than other meteorites. It contained two different lithologies, which are either rich (lithology 1) or poor (lithology 2) in magnetite, pyrrhotite, and dolomite. CHN compounds were more concentrated in lithology 1 than in lithology 2; on the other hand, CHO, CHO–Na, and CHNO compounds were distributed in both lithologies. Such different spatial distribution of SOM is likely the result of interaction of the SOM with minerals, during precipitation of the SOM via fluid activity, or could be due to difference in transportation efficiencies of SOMs in aqueous fluid. Organic-related ions measured by time-of-flight secondary ion mass spectrometry (ToF–SIMS) did not coincide with the spatial distribution revealed by DESI-HRMS imaging. This result may be because the different ionization mechanism between DESI and SIMS, or indicate that the ToF–SIMS data would be mainly derived from methanol-insoluble organic matter in A0080. In the Orgueil meteorite, such relationship between altered minerals and SOM distributions was not observed by DESI-HRMS analysis and field-emission scanning electron microscopy, which would result from differences of SOM formation processes and sequent alteration process on the parent bodies or even on the Earth. Alkylated homologues of CHN compounds were identified in A0080 by DESI-HRMS imaging as observed in the Murchison meteorite, but not from the Orgueil meteorite. These compounds with a large C number were enriched in Murchison fragments with abundant carbonate grains. In contrast, such relationship was not observed in A0080, implying different formation or growth mechanisms for the alkylated CHN compounds by interaction with fluid and minerals on the Murchison parent body and asteroid Ryugu.

Ryugu↗

The Peregrine Ion Trap Mass Spectrometer (PITMS) Investigation Development and Pre-Flight Planning

The Peregrine Ion Trap Mass Spectrometer (PITMS) is a mass spectrometer instrument that operated during the Astrobotic Peregrine Mission-1 as part of the NASA Commercial Lunar Payload Services (CLPS) initiative. This paper describes the instrument and investigation design, development, and planning conducted by the PITMS team consisting of a successful partnership between NASA Goddard Space Flight Center (GSFC), The Open University (OU), NASA, and ESA. PITMS was designed to measure the abundance and temporal variability of volatile species in the near-surface lunar exosphere from a landed platform on the lunar surface. The PITMS instrument consisted of an ESA-provided Exospheric Mass Spectrometer (EMS; including sensor, electronics, controller, power supply boards) and a GSFC wrapper that provided structural elements, thermal control, and a deployable dust cover. PITMS was designed to operate as a passive sampler, where ambient gases would enter PITMS through an aperture, diffuse around the mass analyzer cavity, become ionized by electron impact and trapped in a radiofrequency field, then sequentially released to a detector to build a mass spectrum. PITMS was capable of measuring species with a massto-charge ratio (m/z) from 10 to 150 Da, with a mass resolution of approximately 0.5 amu. The PITMS science investigation was planned to be operated by GSFC with an international team of scientists. Though the mission did not achieve its lunar landing, information about the PITMS instrument and planning is provided to be able to understand and effectively use data that will be forthcoming from the investigation.

Barbara Cohen↗

Comparison and validation of the QuEChERSER mega-method for determination of per- and polyfluoroalkyl substances in foods by liquid chromatography with high-resolution and triple quadrupole mass spectrometry

Instances of food contamination with per- and polyfluoroalkyl substances (PFAS) continue to occur globally, but sample preparation and analytical methods are quite limited and often monitor for a small percentage of known PFAS. This study aimed to evaluate, validate, and compare performance of two instruments with the recently developed “quick, easy, cheap, effective, rugged, safe, efficient, and robust” (QuEChERSER) sample preparation mega-method – a method developed to monitor chemicals over a broad range of physicochemical properties. Initial evaluation of the QuEChERSER mega-method for determination of PFAS in food demonstrated recoveries, matrix interferences, and co-extractive removal comparable to (or better than) US Food and Drug Administration (FDA) and USDA Food Safety and Inspection Service (FSIS) methods. Subsequent validation of QuEChERSER in beef, catfish, chicken, pork, liquid eggs, and powdered eggs on a high-resolution mass spectrometer achieved acceptable recoveries (70–120%) and precision (RSDs ≤20%) for all 33 target analytes at the 1 and 5 ng g –1 levels and 67–88% of analytes at the 0.1 ng g –1 level, depending on the matrix. Additional validation was performed by tandem mass spectrometry on a triple quadrupole instrument. This approach provided no non-detects and better recoveries at the 0.1 ng g –1 level than the HRMS method but exhibited more variability at 1 and 5 ng g –1 spiking levels. Analysis of NIST SRMs 1946 and 1947 gave accuracies of 70–117%. Furthermore, these results demonstrate the capability of combining PFAS analysis with a mega-method previously validated for 350 analytes, while collecting non-target data for future retrospective analysis of emerging alternatives with a high-resolution mass spectrometry method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ambient Single-Cell Analysis and Native Tissue Imaging Using Laser-Ablation Electrospray Ionization Mass Spectrometry with Increased Spatial Resolution

Laser ablation electrospray ionization mass spectrometry (LAESI-MS) is an emerging method that has the potential to transform the field of metabolomics. This is in part due to LAESI-MS being an ambient ionization method that requires minimal sample preparation and uses (endogenous) water for in situ analysis. This application note details the employment of the ‘LAESI microscope’ source to perform spatially resolved MS analysis of cells and MS imaging (MSI) of tissues at high spatial resolution. This source configuration utilizes a long-working distance reflective objective that permits both visualization of the sample and a smaller LAESI laser beam profile than conventional LAESI setups. In this work, we analyzed 200 single cells of Allium cepa (red onion) and imaged Fittonia argyroneura (nerve plant) in high spatial resolution using this source coupled to a Fourier transform mass spectrometer for high mass resolution and high mass accuracy metabolomics.

59 BASIC BIOLOGICAL SCIENCES↗

Determination of 2,3,7,8-chlorine-substituted dibenzo-p-dioxins and -furans at the part per trillion level in United States beef fat using high-resolution gas chromatography/high-resolution mass spectrometry

As part of the U.S. EPA Dioxin Reassessment Program, the 2,3,7,8-chlorine-substituted dibenzo-p-dioxins and furans were measured at part per trillion (ppt) levels in beef fat collected from slaughter facilities in the United States. This is the first statistically designed national survey of these compounds in the U.S. beef supply. Analyte concentrations were determined by high-resolution gas chromatography/high-resolution mass spectrometry, using isotope dilution methodology. Method limits of detection on a whole weight basis were 0.05 ppt for TCDD and 0.10 ppt for TCDF, 0.50 ppt for the pentas (PeCDDs/PeCDFs)/hexas (HxCDDs/HxCDFs)/heptas (HpCDDs/HpCDFs), and 3.00 ppt for the octas (OCDD/OCDF). Method detection and quantitation limits were established on the basis of demonstrated performance criteria utilizing fortified samples rather than by conventional signal-to-noise or variability of response methods. The background subtraction procedures developed for this study minimized the likelihood of false positives and increased the confidence associated with reported values near the detection limits. Mean and median values for each of the 2,3,7,8-Cl-substituted dioxins and furans are reported, along with the supporting information required for their interpretation. The mean toxic equivalence values for the samples are 0.35 ppt (nondetects = 0) and 0.89 ppt (nondetects = 1/2 LOD).

Benzofurans/analysis↗

A Dual-Gated Structures for Lossless Ion Manipulations-Ion Mobility Orbitrap Mass Spectrometry Platform for Combined Ultra-High-Resolution Molecular Analysis

High-resolution ion mobility spectrometry-mass spectrometry (HR-IMS-MS) instruments have enormously advanced the ability to characterize complex biological mixtures. Unfortunately, HR-IMS and HR-MS measurements are typically performed independently due to mismatches in analysis time scales. Here we overcome this limitation by using a dual-gated ion injection approach to couple an 11-meter path length structures for lossless ion manipulations (SLIM) module to a Q-Exactive Plus Orbitrap MS. The dual-gate setup was implemented by placing one ion gate before the SLIM module and a second ion gate after. The dual-gated ion injection approach allowed the new SLIM-Orbitrap platform to simultaneously perform an 11-meter SLIM separation, Orbitrap mass analysis using the highest selectable mass resolution setting (up to 140k), and high-energy collision induced dissociation (HCD) in ~25 minutes over an $m/z$ range of ~1500 amu. The SLIM-Orbitrap was initially characterized using a mixture of standard phosphazene cations and demonstrated an average SLIM CCS resolving power (Rp CCS ) of ~218 and SLIM peak capacity of ~156 while simultaneously obtaining high mass resolutions. SLIM-Orbitrap analysis with fragmentation was then performed on mixtures of standard peptides and two reverse peptides (SDGRG 1+ , GRGDS 1+ , Rp CCS = 305) to demonstrate the utility of combined HR-IMS-MS/MS measurements for peptide identification. Our new HR-IMS-MS/MS capability was further demonstrated by analyzing a complex lipid mixture and showcasing SLIM separations on isobaric lipids. In conclusion, this new SLIM-Orbitrap platform demonstrates a critical new capability for proteomics and lipidomics applications, and the high-resolution multimodal data obtainable with this system establishes the foundation for reference-free identification of unknown ion structures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design and development of a fast ion mass spectrometer

Two Fast Ion Mass Spectrometers (FIMS A and FIMS B) were developed. The design, development, construction, calibration, integration, and flight of these instruments, along with early results from the data analysis efforts are summarized. A medium energy ion mass spectrometer that covers mass velocity space with significantly higher time resolution, improved mass resolution, (particularly for heavier ions), and wider energy range than existing instruments had achieved was completed. The initial design consisted of a dual channel cylindrical electrostatic analyzer followed by a dual channel cylindrical velocity filter. The gain versus count rate characteristics of the high current channel electron multipliers (CEM's), which were chosen for ion detection, revealed a systematic behavior that can be used as a criterion for selection of CEM's for long counting lifetimes.

Burch, J. L.↗

Ion masking improves resolution in quadrupole mass spectrometers

Mass spectrometers analyze molecular composition by determining mass-to-charge ratio of ion fragments of molecules. Study adds significantly to quantitative understanding of quadrupole mass filter. It includes development of quantitative theory of ion oscillations, computer analysis of ion behavior, and identification of determining factors in peak tail size.

Ierokomos, N.↗

Experimental comparison of two hot-wire techniques for resolution of turbulent mass flux and local stagnation temperature in supersonic flow

The performance of two constant-temperature normal hot-wire techniques in a supersonic flow is examined. The first technique uses a single-wire and rapid scanning of multiple overheat ratios. Time averages of the signals at all overheats are used to separate the mean and rms mass flux, stagnation temperature and their cross-correlation. The second technique uses a dual-wire probe with each wire operating at different overheat ratios, giving instantaneous mass flux and stagnation temperature. Preliminary results indicate that the separation distance (0.18 mm) between the two hot wires in the dual-wire probe does not introduce significant error. However, the rms mass flux inferred from the dual-wire technique is a factor of two higher than that from the single-wire technique.

Walker, D. A.↗