Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Logs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Characterization of the Martinsburg Formation using Computed Tomography and Geophysical Logging Techniques

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) Morgantown site were used to characterize 9 different core sections of Upper Ordovician black shale from the Eastern Panhandle of West Virginia. The samples are representative of the upper Ordovician Martinsburg Formation, a Utica Shale equivalent, which is a carbonaceous black shale in the Appalachian Basin. The primary impetus of this work was to develop a standardized methodology for the rapid and detailed characterization of chemical composition, physical characteristics, and internal micro structure of lithologic samples with the NETL core characterization equipment. Having a standardized methodology combining these innovative techniques allows large, rapidly produced data sets to be available for multiple researchers and allows collaborative studies. The resultant data sets are presented as part of this report as well and can be accessed from NETL's Energy Data eXchange (EDX) online system (https://edx.netl.doe.gov) using the following link: https://edx.netl.doe.gov/dataset/martinsburg-formation-ct-data. All equipment and techniques used were non-destructive, enabling future examinations to be performed on these cores with the additional information gathered through these tests. None of the equipment used was suitable for direct visualization of the shale pore space, though fractures and discontinuities were visible and detectable with all methods tested. High resolution CT imagery with the NETL industrial CT scanner was a powerful and insightful way to examine the details of fractures, discontinuities, minerals, and large crystals within the shale, but was time consuming both in image capture and analysis. As such, only a small percentage of the core was scanned at high resolution. Low resolution CT imagery with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with the measurements from the multi-sensor core logger (including x-ray fluorescence, XRF, measurements) were very useful in identifying zones of interest for more detailed analysis and fractured zones. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of all methods used provided a multi-scale analysis of this core and provided both a macro and micro description of the core that is relevant for many subsurface energy related examinations of core that have traditionally been performed at NETL.

47 OTHER INSTRUMENTATION↗

Temperature Monitoring and Data-logging System Operating Manual

The MD-2 LabVIEW program is designed to monitor and store the temperature data from the MD-2 Compliance Testing. The program allows the user to easily configure and track data. A configuration file can be modified and stored to provide the setup parameters. It provides a user interface that easily informs the user about unforeseen anomalies.

42 ENGINEERING↗

Microtron Data Log

The Microtron at Los Alamos National Laboratory (LANL) is a versatile electron accelerator originally designed for medical therapy. Since 2001, it has been used for non-destructive radiographic imaging and research and development applications. Operating at four different energy levels—6, 10, 15, and 20 MeV—the Microtron produces dose rates of approximately 780, 1800, 2700, and 2800 R/min at a distance of one meter from the source, respectively. This high-energy X-ray source enables detailed internal examination of dense and thick objects without causing damage, making it invaluable for various scientific and industrial applications. For instance, LANL’s Microtron has been utilized to study the performance of large-panel cerium-doped lutetium yttrium silicon oxide (LYSO) scintillators, which are essential components in advanced imaging systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Return to [log-]normalcy: rethinking quenching, the star formation main sequence, and perhaps much more

Knowledge of galaxy evolution rests on cross-sectional observations of different objects at different times. Understanding of galaxy evolution rests on longitudinal interpretations of how these data relate to individual objects moving through time. The connection between the two is often assumed to be clear, but we use a simple “physics-free” model to show that it is not and that exploring its nuances can yield new insights. Comprising nothing more than 2094 loosely constrained lognormal star formation histories (SFHs), the model faithfully reproduces the following data it was not designed to match: stellar mass functions at z⩽8; the slope of the star formation rate/stellar mass relation (the SFR “Main Sequence”) at z⩽6; the mean sSFR(≡SFR/M{sub ∗}) of low-mass galaxies at z⩽7; “fast-” and “slow-track” quenching; downsizing; and a correlation between formation timescale and sSFR(M{sub ∗},t) similar to results from simulations that provides a natural connection to bulge growth. We take these findings—which suggest that quenching is the natural downturn of all SFHs affecting galaxies at rates/times correlated with their densities—to mean that: (1) models in which galaxies are diversified on Hubble timescales by something like initial conditions rival the dominant grow-and-quench framework as good descriptions of the data; or (2) absent spatial information, many metrics of galaxy evolution are too undiscriminating—if not inherently misleading—to confirm a unique explanation. We outline future tests of our model but stress that, even if ultimately incorrect, it illustrates how exploring different paradigms can aid learning and, we hope, more detailed modeling efforts.

79 ASTRONOMY AND ASTROPHYSICS↗

Productivity and Cost of Post-Tornado Salvage Logging in Upper Coastal Plain of South Carolina, USA

Salvage harvesting is common in the US South following natural disasters such as tornadoes and hurricanes; nevertheless, few studies have evaluated the productivity and costs of these harvests because of their geographic dispersion and the short interval between natural disasters and salvage harvesting. An Enhanced Fujita Scale 3 (EF3) tornado with winds in excess of 250 km per hour struck Aiken County, South Carolina in April of 2020, uprooting trees and severing other stems above breast height. The goal of this study was to estimate the productivity and cost of salvage harvesting in loblolly pine (Pinus taeda L.) stands following severe tornado damage. Salvage harvests were conducted with a rubber-tired drive-to-tree feller-buncher, grapple skidder, tracked loader, and chipper. All stems were chipped and used to produce energy; no roundwood was produced from the harvests. Elemental time-and-motion studies were conducted in three pulpwood-sized stands (<30 cm large-end diameter) and three sawtimber-sized stands (≥30 cm large-end diameter). Hourly harvesting costs were estimated using the machine rate method and per-ton costs were estimated using a modified version of the Auburn Harvesting Analyzer. Skidding productivity was low in each harvest unit, but especially so in the three pulpwood-sized stands because of stem breakage and low weight per stem. Harvesting costs averaged $\$$29.78 and $\$$19.97 (USD) per tonne (onboard truck) in the pulpwood- and sawtimber-sized stands, respectively. High salvage harvesting costs mean that landowners can expect significantly reduced stumpage prices from these harvests; nonetheless, landowners do benefit from reduced reforestation costs. Harvesting promptly after a tornado can reduce harvesting costs and increase timber value recovery.

60 APPLIED LIFE SCIENCES↗

Log amplifier instrument measures physiological biopotentials over wide dynamic range

To record biopotentials with extreme dynamic ranges, biopotential inputs are capacitatively coupled to a miniature, low power, solid-state signal conditioner consisting of a two-stage differential preamplifier that has a low noise figure. The ouput of the preamplifier uses diodes to provide an overall gain which is nearly logarithmic.

Kado, R. T.↗

A slow-speed multiple-channel analog-to-digital data logging system

The system was developed to record from one up to a maximum of sixteen channels of analog data onto magnetic tape. Each analog channel of data can be sampled at rates of 1, 2, 6, 12, or 60 times per minute. The system is divided into three subunits: a digital clock, an incremental magnetic tape recorder, and a sequential converter. The interfacing requirements of these subunits are presented.

Lloyd, T. C.↗

Robustness properties of discrete time regulators, LOG regulators and hybrid systems

Robustness properites of sample-data LQ regulators are derived which show that these regulators have fundamentally inferior uncertainty tolerances when compared to their continuous-time counterparts. Results are also presented in stability theory, multivariable frequency domain analysis, LQG robustness, and mathematical representations of hybrid systems.

Stein, G.↗

Log-Output Signal Processor Scans Eight Decades

Processor has automatic range switching and continuous readout over eight decades. Comparator output switches logarithmic converter to detector of interest and enables blinder grid to protect more-sensitive detector when operating in high-input range. Could be used to process any wide-varying signal that is to be read on a limited-range recording device such as a strip-chart recorder.

Hayden, J. L.↗

Correlation of Preston-tube data with laminar skin friction (Log No. J12984)

Preston tube data within laminar boundary layers obtained on a sharp ten-degree cone in the NASA Ames eleven-foot transonic wind tunnel are correlated with the corresponding values of theoretical skin friction. Data were obtained over a Mach number range of 0.30 to 0.95 and unit Reynolds numbers of 9.84, 13.1, and 16.4 million per meter. The rms scatter of skin friction coefficient about the correlation is of the order of one percent, which is comparable to the reported accuracy for calibrations of Preston tubes in incompressible pipe flows. In contrast to previous works on Preston tube/skin friction correlations, which are based on the physical height of the probe's face, this satisfactory correlation for compressible boundary layer flows is achieved by accounting for the effects of a variable "effective" height of the probe. The coefficients, which appear in the correlation, are dependent on the particular tunnel environment. The general procedure can be used to define correlations for other wind tunnels.

Reed, T. D.↗