Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Linear accelerators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

High-accuracy absolute magnetometry with application to the Fermilab Muon g-2 experiment

We present details of a high-accuracy absolute scalar magnetometer based on pulsed proton NMR. The B-field magnitude is determined from the precession frequency of proton spins in a cylindrical sample of water after accounting for field perturbations from probe materials, sample shape, and other corrections. Features of the design, testing procedures, and corrections necessary for qualification as an absolute scalar magnetometer are described. The device was tested at B = 1.45 T but can be modified for a range exceeding 1–3 T. The magnetometer was used to calibrate other NMR magnetometers and measure absolute magnetic field magnitudes to an accuracy of 19 parts per billion as part of a measurement of the muon magnetic moment anomaly at Fermilab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the fractional radiation length of a pixel module for the CMS Phase-2 upgrade via the multiple scattering of positrons

High-luminosity particle collider experiments such as theones planned at the High-Luminosity Large Hadron Collider requireever-greater vertexing precision of the tracking detectors,necessitating reductions in the material budget of the detectors.Traditionally, the fractional radiation length (x/X$_{0}$) ofdetectors is either estimated using known properties of theconstituent materials, or measured in dedicated runs of the finaldetector. In this paper, we present a method of direct measurementof the material budget of a CMS prototype module designed for thePhase-2 upgrade of the CMS detector using a 40–65 MeV positronbeam. A total of 630 million events were collected at the PaulScherrer Institut PiE1 experimental area using a three-planetelescope consisting of the prototype module as the central plane,surrounded by two MALTA monolithic pixel detectors. Fractionalradiation lengths were extracted from scattering angle distributionsusing the Highland approximation for multiple scattering. Astatistical technique recovered runs suffering from triggerdesynchronisation, and several corrections were introduced tocompensate for local inefficiencies related to geometric and beamshape constraints. Two regions of the module were surveyed andyielded average x/X$_{0}$ values of (0.72 ± 0.05)% and(0.95 ± 0.09)%, which are compatible with empirical estimatesfor these regions computed from known material properties of 0.753%and 0.892%, respectively. Two types of higher-granularity maps ofthe fractional radiation length were produced, subdivided eitherinto rectangular regions of uniform size, or polygonal-shapedregions of uniform material composition. The results bode well forthe CMS Phase-2 upgrade modules, which will play a key role in theminimisation of the material of the upgraded detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Anode sensitivity calibration of photomultiplier tubes used as a readout of the ELOSS detector

We present and discuss the methodology and results for an anode sensitivity calibration of Photomultiplier Tubes (PMTs) that serve as the optical readout of the Energy Loss Optical Scintillation System (ELOSS). The ELOSS detector, under development at the Facility for Rare Isotope Beams (FRIB), is a gaseous Xe scintillation-based detector designed to identify the atomic number (Z) of nuclear reaction fragments by energy-loss measurement. Variation in the anode sensitivity from tube to tube of commercially available PMTs limits ELOSS from reaching its ultimate Z resolution. A methodical approach to calibrating PMT anode sensitivities to a single target value by systematic PMT gain corrections is presented. Although the calibration process is discussed in terms of its impact on ELOSS performance, the presented method is applicable to any optical detector system composed of a large number of PMTs needing anode sensitivity calibration.

Instrumentation for heavy-ion accelerators↗

SEM Grid Testing at NLCTA in BeamNetUS Program

We report on the performance of a secondary electron monitor (SEM) grid used to measure the transverse profile of an MeV range electron beam at SLAC National Accelerator Laboratory’s Next Linear Collider Test Accelerator (NLCTA) facility. When inserted into the path of the electron beam, secondary electron emission results in a measurable current on the wires that make up the grid. We present measurements using this technique to reconstruct the beam profile. The SEM grid was designed and manufactured by a team of undergraduate students at Harvey Mudd College (HMC) and was tested at SLAC’s NLCTA facility in collaboration with NCLTA staff as part of the BeamNetUS program. Developed for real-time diagnostics of MeV-range electron beams, this SEM grid has potential applications in both industrial and medical contexts.

43 PARTICLE ACCELERATORS↗

Analysis of cell-based diffusion acceleration for the slice balance approach

In this work, we perform analysis on the use of cell-based diffusion acceleration methodologies to accelerate the convergence of transport solutions discretized with the slice balance approach (SBA) on unstructured polygonal grids.We investigated both linear diffusion synthetic acceleration (DSA) and non linear diffusion acceleration (NDA), including its partial-current variant (pNDA). DSA and NDA were both shown to diverge for intermediate ranges of mesh optical thicknesses. However, pNDA and Krylov methods like GMRES and Broyden stabilized the acceleration schemes, including problems with degenerate cells formed by mesh refinement. (author)

42 ENGINEERING↗

The Linac Extension Area at the Advanced Photon Source

The Linac Extension Area has been developed into a beamline area for testing accelerator components and techniques. Beginning commissioning activities in February 2023, we have delivered the first electron beam to the Linac Extension Area at the Advanced Photon Source at 425 MeV. In the present work, we summarise the principal accelerator components and review safety controls of the Linac Extension Area.

47 OTHER INSTRUMENTATION↗

Magnetic-Field Diffusion Effects in Beam Position Monitors I: Theory

Beam position monitors (BPMs) provide time-resolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). One of the types of detectors used in BPMs is the B-dot loop, which generates a signal from the EMF due to the time varying magnetic flux through the loop. If some of the boundaries of the loop are composed of thick metal walls with finite conductivity, the resulting signal must be corrected for the magnetic field diffusion into the metal. The theoretically predicted flux due to diffusion is in remarkable agreement with experimental measurements

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam dynamics challenges in linear colliders based on laser-plasma accelerators

In this paper we discuss design considerations and beam dynamics challenges associated with laser-driven plasma-based accelerators as applied to multi-TeV-scale linear colliders. Plasma accelerators provide ultra-high gradients and ultra-short bunches, offering the potential for compact linacs and reduced power requirements. We show that stable, efficient acceleration with beam quality preservation is possible in the nonlinear bubble regime of laser-plasma accelerators using beam shaping. Ion motion, naturally occuring for dense beams (i.e., low emittance and high energy) severely damps transverse beam instabilities. Coulomb scattering by the background ions is considered and it is shown that the strong focusing in the plasma strongly suppresses scattering-induced emittance growth. Finally, Betatron radiation emission from the transverse motion of the beam in the plasma will result in beam power loss and energy spread growth; however for sub-100 nm emittances, the beam power loss and energy spread growth will be sub-percent for multi-TeV-class plasma linacs.

47 OTHER INSTRUMENTATION↗

Positron acceleration in plasma wakefields

Plasma acceleration has emerged as a promising technology for future particle accelerators, particularly linear colliders. Significant progress has been made in recent decades toward high-efficiency and high-quality acceleration of electrons in plasmas. However, this progress does not generalize to the acceleration of positrons, as plasmas are inherently charge asymmetric. Here, we present a comprehensive review of historical and current efforts to accelerate positrons using plasma wakefields. Proposed schemes that aim to increase energy efficiency and beam quality are summarized and quantitatively compared. A dimensionless metric that scales with the luminosity-per-beam power is introduced, indicating that positron-acceleration schemes are currently below the ultimate requirement for colliders. The primary issue is electron motion; the high mobility of plasma electrons compared to plasma ions, which leads to nonuniform accelerating and focusing fields that degrade the beam quality of the positron bunch, particularly for high efficiency acceleration. Finally, we discuss possible mitigation strategies and directions for future research.

43 PARTICLE ACCELERATORS↗

Characterization of a platform for the gas transport, collection, and identification of fission products in the high-intensity laser environment

Recent progress in the production of laser accelerated high flux proton beams opens new possibilities for the study of fission in unique environments. To this end, we are currently pursuing the development of a platform for the swift gas transport, collection, and identification of fission products. Fission is induced in targets fixed inside a sealed chamber through which a carrier gas flows, transporting fission products to a carbon filter for collection and online spectroscopy. This has been recently demonstrated using target normal sheath accelerated protons at the PHELIX laser facility. There were large discrepancies between measured rates and those expected based on established fission yields and measured beam parameters. These discrepancies prompted a large number of tests at the Idaho Accelerator Center (IAC), where fission in uranium is induced by bremsstrahlung photons generated by 21 MeV electrons from a linear electron accelerator. Here, the results are compared to a series of models that account for the slowing of energetic fission fragments in the carrier gas and the fluid dynamics of the gas flow that transports fission products to the collection filter. Characterization of the apparatus reveals a few mechanisms that together account for a portion of the previously observed discrepancies at the PHELIX laser facility. However, additional research is necessary before high-accuracy experiments can be performed with the apparatus. Work performed under the auspices of the U.S. Department of Energy by LLNL under contract DE-AC52-07NA27344.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Current-Pulse Excitation of Beam Breakup in Scorpius

Perhaps the most dangerous instability for electron linear induction accelerators (LIA) is the beam breakup (BBU) instability. For flash-radiography LIAs like DARHT or Scorpius it is particularly troublesome, because low-level high-frequency BBU motion can blur the source spot. Theoretically, the number of e-foldings Γ of exponential BBU growth in an LIA is linearly proportional to beam current I, number of accelerating cells N, and transverse coupling impedance Z ⊥ , and inversely proportional to the strength of magnetic focusing B.

43 PARTICLE ACCELERATORS↗

Data-driven linear time advance operators for the acceleration of plasma physics simulation

In this study, we demonstrate the application of data-driven linear operator construction for time advance with a goal of accelerating plasma physics simulation. We apply dynamic mode decomposition (DMD) to data produced by the nonlinear SOLPS-ITER (Scrape-off Layer Plasma Simulator - International Thermonuclear Experimental Reactor) plasma boundary code suite in order to estimate a series of linear operators and monitor their predictive accuracy via online error analysis. We find that this approach defines when these dynamics can be represented by a sequence of approximate linear operators and is essential for providing consistent projections when compared to an unconstrained application. For linear diffusion and advection–diffusion fluid test problems, we construct and apply operators within explicit and implicit time advance schemes, demonstrating that stability can be robustly guaranteed in each case. We further investigate the use of the linear time advance operators within several integration methods including forward Euler, backward Euler, and the matrix exponential. The application of this method to simulation data from SOLPS-ITER, with varying levels of Markov chain Monte Carlo numerical noise, shows that constrained DMD operators yield a capability to identify, extract, and integrate a (slow) subset of the present timescales. Example applications show that for projected speedup factors of [Formula: see text], and [Formula: see text], a mean relative error of 3%, 5%, and 8% and maximum relative error less than 20% are achievable, which appears acceptable for typical SOLPS-ITER steady-state simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Customized Bayesian optimization for efficient beam tuning at the facility for rare isotope beams

Bayesian optimization (BO) has recently emerged as a powerful approach for on-line beam tuning, and it is rapidly gaining adoption across accelerator facilities due to its flexibility and efficiency in handling complex optimization tasks. At the Facility for Rare Isotope Beams, rapid and reliable tuning is essential to support the delivery of diverse ion species. To improve the practicality of BO in this setting, we implemented several enhancements, including scalarized composite objective construction for multicriteria optimization, asynchronous evaluation for better resource utilization, prior-mean-assisted optimization to accelerate convergence, and a local search strategy for rapid completion of the task. We present the details of these methods, discuss challenges-encountered, and share our experience applying them to specific beam-tuning tasks.

Accelerators & storage rings↗

Short-lived photofission product yields from 238 U and 232 Th at Bremsstrahlung X-ray endpoint energies of 8, 14, and 20 MeV for nuclear forensics isotope production applications

The existing photofission product yield data sets are often based on nuclear models, and limited experimental measurements of these fission product yields have been performed. These experiments resulted in measured cumulative fission product yields (CFPYs) for 238 U and 232 Th for the bremsstrahlung X-ray endpoint energies of 8, 14, and 20 MeV. The half-lives of the reported fission products range from 1.07–40.8 s. This work is motivated by a demonstrated need for novel isotope production methods for nuclear forensics and improved nuclear data to support the nonproliferation community. A high-purity germanium detector and a pneumatic transfer system were employed for measurements of short-lived fission products, collecting data between cycles of accelerator irradiation and measurement.

07 ISOTOPE AND RADIATION SOURCES↗

Latent diffusion can map beam loss to two-dimensional phase-space projections

Beam loss monitors (BLMs) and beam current monitors (BCMs) are ubiquitous at particle accelerators around the world. These simple devices provide noninvasive high-level beam measurements but give no insight into the detailed 6D (𝑥,𝑦,𝑧,𝑝 𝑥 ,𝑝 𝑦 ,𝑝 𝑧 ) beam phase-space distributions or dynamics. We show that generative conditional latent diffusion models can learn intricate patterns to solve the extreme inverse problem of mapping waveforms of tens of BLMs or BCMs along an accelerator to detailed 2D projections of a charged particle beam’s 6D phase-space density. This transformational method can be used at any particle accelerator to transform simple noninvasive devices into detailed beam phase-space diagnostics. We demonstrate this concept via multiparticle simulations of the high-intensity beam in the kilometer-long Los Alamos Neutron Science Center linear proton accelerator.

43 PARTICLE ACCELERATORS↗