Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LiF”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

353 records · Page 20

100 kHz High-Spectral-Resolution NO-PLIF Measurements for Compressible Flows

In the present work, we use a burst-mode laser and optical parametric oscillator system to perform high-spectral resolution NO-PLIF measurements of an underexpanded jet at a repetition-rate of 100 kHz, with the motivation of multi-parameter measurements of temperature, pressure, and velocity. The laser frequency of the 1064 nm seed laser for the burst-mode laser was scanned during the burst to cover two neighboring absorption line pairs near 226 nm. The peak PLIF signal intensity varies along the axial (z) direction of the underexpanded jet as the laser frequency is scanned, which we attribute to the collisional shift induced by the flow and only revealed due to the narrow linewidth of the laser. A pseudo-Voight fit is applied to the LIF excitation spectra on a pixel-by-pixel basis to measure the spectral position of the peak intensity for the two transition pairs and their amplitude. The spectral position of the peak intensity is used to derive a frequency shift, which is separated into its collisional and Doppler components using the axisymmetric nature of the flow field. The amplitude of the measured peaks is used for two-line rotational thermometry. Challenges for quantitative measurements using such an approach are discussed, including measuring the spatial variations in the energy distribution of the laser sheet at a 100 kHz repetition rate and uncertainty/variability in the step size during the fast frequency scan.

laser induced fluorescence↗

100 kHz High-Spectral-Resolution NO-PLIF Measurements for Compressible Flows

In the present work, we use a burst-mode laser and optical parametric oscillator system to perform high-spectral resolution NO-PLIF measurements of an underexpanded jet at a repetition-rate of 100 kHz, with the motivation of multi-parameter measurements of temperature, pressure, and velocity. The laser frequency of the 1064 nm seed laser for the burst-mode laser was scanned during the burst to cover two neighboring absorption line pairs near 226 nm. The peak PLIF signal intensity varies along the axial (z) direction of the underexpanded jet as the laser frequency is scanned, which we attribute to the collisional shift induced by the flow and only revealed due to the narrow linewidth of the laser. A pseudo-Voight fit is applied to the LIF excitation spectra on a pixel-by-pixel basis to measure the spectral position of the peak intensity for the two transition pairs and their amplitude. The spectral position of the peak intensity is used to derive a frequency shift, which is separated into its collisional and Doppler components using the axisymmetric nature of the flow field. The amplitude of the measured peaks is used for two-line rotational thermometry. Challenges for quantitative measurements using such an approach are discussed, including measuring the spatial variations in the energy distribution of the laser sheet at a 100 kHz repetition rate and uncertainty/variability in the step size during the fast frequency scan.

laser induced fluorescence↗

Cryogenic High Accuracy Refraction Measurements Capabilities and New FUV Coating Mirror Technology Developments

This talk will emphasize the basic principles of refractive materials used in an optical telescope. In particular, the presentation will describe refractive index measurements that were performed for one of the instruments on the James Webb Space Telescope (JWST). A refractive system design was implemented in the Near-Infrared Camera (NIRCam) which is one of the main instruments on the JWST observatory. This camera was designed to make observations in the infrared part of the optical spectrum, and it is required to operate in a space environment at temperatures as low as 25K. Therefore, it was imperative to know the refractive index at those low cryogenic temperatures for the various glass substrates (ZnSe, LiF and BaF2) used in the system design of NIRCam. These cryogenic index of refraction measurements were carried out by using the world-class refractometer called the Cryogenic High Accuracy Refraction Measuring System (CHARMS) facility that was designed and built at the Goddard Space Flight Center (GSFC) in Greenbelt, MD. In the second part, there will be a discussion of the recent advances on the research and development activities of advanced and new mirror coating technologies that provide high reflectance performance in the far-ultraviolet (FUV) part of the optical spectrum. These new mirror coatings are envisioned for use on the reflecting mirrors of the next mission (beyond JWST) that will focus on astronomical observations in the FUV spectral range to deliver new and exciting discoveries about the origin of the cosmos.

Astronomy↗

Cryolite Overcoated Aluminum Reflectors for Far-Ultraviolet Spectroscopy

Aluminum (Al) mirrors are conventionally protected with metal-fluoride coatings (e.g., MgF 2 , LiF, or AlF 3 ) immediately after deposition to prevent oxidation and preserve its far-ultraviolet (FUV) spectral efficiency. However, the resulting FUV reflectance of the aluminum reflector is limited by the metal-fluoride overcoat film index of refraction, morphology, stoichiometry, and its absorption cut-off in the lower end of the FUV spectra. Cryolite (sodium hexafluoroaluminate, Na 3 AlF 6 ) emerges as a potential candidate to preserve the aluminum FUV reflectance due to its relatively lower index of refraction in the visible to ultraviolet; therefore, allowing for the thin-film design of highly spectral efficient reflectors over a wide spectral range. We investigate the use of cryolite in aluminum reflector FUV coating design. The deposited aluminum reflector overcoated with cryolite will be examined in terms of spectral efficiency and environmental durability. The deposited cryolite overcoat will be evaluated in terms of optical constants and structural properties. Preliminary results have shown that the use of cryolite as an overcoat to protect aluminum would yield unprecedented results as an optimal Hydrogen Lyman-alpha (HLyα) spectral line reflector, with experimental reflectance values >96%.

optical coating↗

Cryolite Overcoated Aluminum Reflectors for Far-Ultraviolet Spectroscopy

Aluminum (Al) mirrors are conventionally protected with metal-fluoride coatings (e.g., MgF2, LiF, or AlF3) immediately after deposition to prevent oxidation and preserve its far-ultraviolet (FUV) spectral efficiency. However, the resulting FUV reflectance of the aluminum reflector is limited by the metal-fluoride overcoat film index of refraction, morphology, stoichiometry, and its absorption cut-off in the lower end of the FUV spectra. Cryolite (sodium hexafluoroaluminate, Na3AlF6) emerges as a potential candidate to preserve the aluminum FUV reflectance due to its relatively lower index of refraction in the visible to ultraviolet; therefore, allowing for the thin-film design of highly spectral efficient reflectors over a wide spectral range. We investigate the use of cryolite in aluminum reflector FUV coating design. The deposited aluminum reflector overcoated with cryolite will be examined in terms of spectral efficiency and environmental durability. The deposited cryolite overcoat will be evaluated in terms of optical constants and structural properties. Preliminary results have shown that the use of cryolite as an overcoat to protect aluminum would yield unprecedented results as an optimal Hydrogen Lyman-alpha (HLyα) spectral line reflector, with experimental reflectance values >96%.

optical coatings↗

Recent Progress on 2012 SAT for UVOIR Coatings

Astronomical observations in the Far Ultraviolet (FUV) spectral region are some of the more challenging due to the very distant and faint objects that are typically searched for in cosmic origin studies such as origin of large scale structure, the formation, evolution, and age of galaxies and the origin of stellar and planetary systems. These challenges are driving the need to improve the performance of optical coatings over a wide spectral range that would increase reflectance in mirrors and reduced absorption in dielectric filters used in optical telescope for FUV observations. This paper will present recent advances in reflectance performance for Al+MgF2 mirrors optimized for Lyman-alpha wavelength by performing the deposition of the MgF2 overcoat at elevated substrate temperatures. We will also present optical characterization of little studied rare-earth fluorides such as GdF3 and LuF3 that exhibit low-absorption over a wide wavelength range and could therefore be used as high refractive index alternatives fordielectric coatings at FUV wavelengths.

LiF↗

Comparisons Between NO PLIF Imaging and CFD Simulations of Mixing Flowfields for High-Speed Fuel Injectors

The current work compares experimentally and computationally obtained nitric oxide (NO) planar laser-induced fluorescence (PLIF) images of the mixing flowfields for three types of high-speed fuel injectors: a strut, a ramp, and a rectangular flushwall. These injection devices, which exhibited promising mixing performance at lower flight Mach numbers, are currently being studied as a part of the Enhanced Injection and Mixing Project (EIMP) at the NASA Langley Research Center. The EIMP aims to investigate scramjet fuel injection and mixing physics, and improve the understanding of underlying physical processes relevant to flight Mach numbers greater than eight. In the experiments conducted in the NASA Langley Arc-Heated Scramjet Test Facility (AHSTF), the injectors are placed downstream of a Mach 6 facility nozzle, which simulates the high Mach number air flow at the entrance of a scramjet combustor. Helium is used as an inert substitute for hydrogen fuel. Both schlieren and PLIF techniques are applied to obtain mixing flowfield flow visualizations. The experimental PLIF is obtained by using a UV laser sheet to interrogate a plane of the flow by exciting fluorescence from the NO molecules that are present in the AHSTF air. Consequently, the absence of signal in the resulting PLIF images is an indication of pure helium (fuel). The computational PLIF is obtained by applying a fluorescence model for NO to the results of the Reynolds-averaged simulations (RAS) of the mixing flowfield carried out using the VULCAN-CFD solver. This approach is required because the PLIF signal is a nonlinear function of not only NO concentration, but also pressure, temperature, and the flow velocity. This complexity allows additional flow features to be identified and compared with those obtained from the computational fluid dynamics (CFD) simulations, however, such comparisons are only semiquantitative. Three-dimensional image reconstruction, similar to that used in magnetic resonance imaging, is also used to obtain images in the streamwise and spanwise planes from select cross-stream PLIF plane data. Synthetic schlieren is also computed from the RAS data. Good agreement between the experimental and computational results provides increased confidence in the CFD simulations for investigations of injector performance.

PLIF↗

Comparisons Between NO PLIF Imaging and CFD Simulations of Mixing Flowfields for High-Speed Fuel Injectors

The current work compares experimentally and computationally obtained nitric oxide (NO) planar laser-induced fluorescence (PLIF) images of the mixing flowfields for three types of high-speed fuel injectors: a strut, a ramp, and a rectangular flushwall. These injection devices, which exhibited promising mixing performance at lower flight Mach numbers, are currently being studied as a part of the Enhanced Injection and Mixing Project (EIMP) at the NASA Langley Research Center. The EIMP aims to investigate scramjet fuel injection and mixing physics, and improve the understanding of underlying physical processes relevant to flight Mach numbers greater than eight. In the experiments conducted in the NASA Langley Arc-Heated Scramjet Test Facility (AHSTF), the injectors are placed downstream of a Mach 6 facility nozzle, which simulates the high Mach number air flow at the entrance of a scramjet combustor. Helium is used as an inert substitute for hydrogen fuel. Both schlieren and PLIF techniques are applied to obtain mixing flowfield flow visualizations. The experimental PLIF is obtained by using a UV laser sheet to interrogate a plane of the flow by exciting fluorescence from the NO molecules that are present in the AHSTF air. Consequently, the absence of signal in the resulting PLIF images is an indication of pure helium (fuel). The computational PLIF is obtained by applying a fluorescence model for NO to the results of the Reynolds-averaged simulations (RAS) of the mixing flowfield carried out using the VULCAN-CFD solver. This approach is required because the PLIF signal is a nonlinear function of not only NO concentration, but also pressure, temperature, and the flow velocity. This complexity allows additional flow features to be identified and compared with those obtained from the computational fluid dynamics (CFD) simulations, however, such comparisons are only semiquantitative. Three-dimensional image reconstruction, similar to that used in magnetic resonance imaging, is also used to obtain images in the streamwise and spanwise planes from select cross-stream PLIF plane data. Synthetic schlieren is also computed from the RAS data. Good agreement between the experimental and computational results provides increased confidence in the CFD simulations for investigations of injector performance.

PLIF↗

Environmental and Polarization Characterizations of E-Beam Plasma-Based AlF 3 -Passivated Aluminum Mirrors for Astronomical Telescopes

Astronomical space telescopes to study astrophysical phenomena from the far ultraviolet (FUV) to the near infrared (NIR) will require mirror coatings with high reflectance over this entire spectral region. While coatings for the optical and NIR part of the spectrum are fairly well developed with proven performance, the FUV range has presented significant challenges, particularly below 120nm. Recent developments in electron-beam (e-Beam) generated plasma treatment in a SF 6 environments has enabled the effective passivation of aluminum (Al) coatings for applications in the FUV, by native oxide removal and the formation of a AlF 3 passivation layer which could be tuned to any desired AlF 3 thickness. These results have been produced through a collaboration between the Goddard Space Flight Center (GSFC) and the Naval Research Laboratory (NRL). The passivation experiments have been carried out using the Large Area Plasma Processing System (LAPPS) at NRL using bare aluminum samples and provided by the coating group at GSFC. This novel procedure has demonstrated improved Al mirrors with state-of-the-art FUV reflectivity (e.g. R=91% at 121.6nm). In this paper, we will be reporting on environmental testing, micro-roughness, as well as polarization studies of these E-beam treated samples. These characterizations are being done in order to advance the Technology Readiness Level (TRL) for these Al+AlF 3 mirror coatings produced at LAPPS. The ultimate goal is to demonstrate the promise of using this coating technology to deliver reflectance performance plus stability and uniformity over a large area for a future IR/O/UV space telescope observatory.

FUV reflectance↗