Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Hydrodynamic Flows in Microsized Liquid Crystal Cells with Orientational Defects

The effect of the orientational defect (OD) on the formation process of a vortical flow v(t, r), emerging in a microsized liquid crystal (LC) cell under the action of a focused laser radiation, was studied within the nonlinear generalization of the classical Ericksen–Leslie theory by numerical methods, considering the thermomechanical contributions to both the stress tensor and viscous torque, that acts on the unit volume of the liquid crystal phase (LC phase). The analysis of the obtained results showed that the vortical flow, rotating clockwise, is generated in a “defect” LC cell close to the OD, with the OD, placed on the lower bounding surface, on which the laser radiation was focused. The rotational velocity of this flow is two orders of magnitude greater than the rotational velocity of the vortex, which is generated in a “pure” LC cell at the same conditions and rotates anticlockwise.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Diving into Petascale Production File Systems through Large Scale Profiling and Analysis

As leadership computing facilities grow their storage capacity into the multi- petabyte range, the number of files and directories leap into the scale of billions. A complete profiling of such a parallel file system in a production environment presents a unique challenge. On one hand, the time, resources, and negative performance impact on production users can make regular profiling difficult. On the other hand, the result of such profiling can yield much needed understanding of the file system's general characteristics, as well as provide insight to how users write and access their data on a grand scale. This paper presents a lightweight and scalable profiling solution that can efficiently walk, analyze, and profile multi-petabyte parallel file systems. This tool has been deployed and is in regular use on very large-scale production parallel file systems at both Oak Ridge National Lab's Oak Ridge Leadership Facility (OLCF) and Lawrence Livermore National Lab's Livermore Computing (LC) facilities. We present the results of our initial analysis on the data collected from these two large-scale production systems, organized into three use cases: (1) file system snapshot and composition, (2) striping pattern analysis for Lustre, and (3) simulated storage capacity utilization in preparation for future file systems. Our analysis shows that on the OLCF file system, over 96% of user files exhibit the default stripe width, potentially limiting performance on large files by underutilizing storage servers and disks. Our simulated block analysis quantitatively shows the space overhead when doing a forklift system migration. It also reveals that due to the difference in system compositions (OLCF vs. LC), we can achieve better performance and space trade-offs by employing different native file system block sizes.

Wang, Feiyi↗

Livermore Computing User and System Scripts

LCUSS is a collection of scripts used to improve productivity on HPC systems for both administrators and general users. It will include general scripts for user management, scripts for helping users interact with LC resource management software (e.g. SLURM and Flux), and scripts to automate common user command-line tasks on LC and other HPC machines. These scripts are intended to be made available to all LC users. Hosting them on GitHub will allow LC staff, users, and collaborators to work on them together.

Long, Jeffery↗

Data from Improved Annotation of Untargeted Metabolomics Data through Buffer Modifications That Shift Adduct Mass and Intensity

Annotation of untargeted high-resolution full-scan LC-MS metabolomics data remains challenging due to individual metabolites generating multiple LC-MS peaks arising from isotopes, adducts, and fragments. Adduct annotation is a particular challenge, as the same mass difference between peaks can arise from adduct formation, fragmentation, or different biological species. To address this, here we describe a buffer modification workflow (BMW) in which the same sample is run by LC-MS in both liquid chromatography solvent with 14NH3–acetate buffer and in solvent with the buffer modified with 15NH3–formate. Buffer switching results in characteristic mass and signal intensity changes for adduct peaks, facilitating their annotation. This relatively simple and convenient chromatography modification annotated yeast metabolomics data with similar effectiveness to growing the yeast in isotope-labeled media. Application to mouse liver data annotated both known metabolite and known adduct peaks with 95% accuracy. Overall, it identified 26% of ∼27 000 liver LC-MS features as putative metabolites, of which ∼2600 showed HMDB or KEGG database formula match. This workflow is well suited to biological samples that cannot be readily isotope labeled, including plants, mammalian tissues, and tumors.

Conversion↗

OC6 Phase III: Validation of Wind Turbine Aerodynamic Loading During Surge/Pitch Motion

The objective of Phase III of the Offshore Code Comparison Collaboration, Continued, with Correlation and unCertainty (OC6) project was to validate the accuracy of aerodynamic load predictions by offshore wind modeling tools for a floating offshore wind turbine as it experiences large surge-translational and pitch-rotational motion, as would occur during normal operation. The test data considered were generated at Politecnico di Milano – a wind tunnel with a robotic excitation system to emulate wave loading on the wind turbine. Testing was performed using a scaled version of the DTU 10-MW reference model, and motion was prescribed as harmonic oscillations in the surge and pitch directions, independently. A variety of models were examined in the project, performing a three-way validation between engineering-level tools, higher-fidelity tools, and measurement data from two wind tunnel experimental campaigns. The Load Cases (LC) considered in this testing are as follows: LC 1.X - Steady Wind LC 2.X - Unsteady Wind - Surge Motion LC 3.X - Unsteady Wind - Pitch Motion Details on the results of the OC6 Phase III campaign can be found in the following reference: Bergua R., et al. OC6 project Phase III: validation of the aerodynamic loading on a wind turbine rotor undergoing large motion caused by a floating support structure, Wind Energ. Sci., 8, 465–485, https://doi.org/10.5194/wes-8-465-2023, 2023.

17 WIND ENERGY↗

FOCAL Campaign I: Advanced Wind Turbine Control Strategies

Campaign I of the Floating Offshore-wind Controls Advanced Laboratory Experimental Program (FOCAL) aims to generate a dataset enabling the validation of aerodynamic performance of a scaled turbine mounted on a rigid tower in a fixed condition. The turbine considered in the FOCAL testing campaigns is the IEA-Wind 15MW Reference Wind Turbine. This scaled model is capable of simulating advanced blade-pitch control strategies in a high-quality wind field. The turbine is fully instrumented to record a variety of parameters in real time such as structural loads and dynamics. The test data considered was generated at the University of Maine's Harold Alfond Wind and Wave (W2) testing facility. The Load Cases (LC) considered in this testing campaign are as follows: LC 1.X - Constant wind and blade-pitch with varying rotor speeds LC 2.X - Constant wind and rotor speed with varying blade-pitch LC 3.X - Varying wind with active closed-loop control Detailed properties on the modeled system are found in the following reference: Lenfest E., Floating Offshore-wind Controls Advanced Laboratory (FOCAL) Experimental Program - Campaign I: 1:70 Model-scale Testing of the IEA-Wind 15MW Reference Turbine. UMaine ASCC Report Number 23-40-1183. Details on the results of the verification and validation are found in the following reference: Mendoza, Nicole et al., "Verification and Validation of Model-Scale Turbine Performance and Control for the IEA Wind 15 MW Reference Wind Turbine," Energies, vol. 15, no. 20, 2022, https://doi.org/10.3390/en15207649.

17 WIND ENERGY↗

FOCAL Campaign II/III: Applying Active Hull Controls Using Tuned-mass Dampers/Hull Flexibility and Internal Loads

Campaign II and III of the Floating Offshore-wind Controls Advanced Laboratory Experimental Program (FOCAL) aimed to generate a dataset enabling the validation of the performance and loads of a scaled hull, with and without structural hull control. The floating platform was subjected to a variety of wave environments and controlled using tuned-mass dampers (TMDs) tuned to two of the systems natural frequencies (Platform Pitch and Tower-bending). The floating platform is fully instrumented to record a variety of parameters in real time such as platform dynamics, accelerations, and loads at different points in the structure. The test data considered was generated at the University of Maine's Harold Alfond Wind and Wave (W2) testing facility. This testing was focused only on validation of wave loading, and wind conditions were not considered. As such the platform does not support a working turbine, and instead supports a structure designed to have the same mass properties as the 1:70 IEA 15MW Reference turbine. The Load Cases (LC) considered in this testing campaign are as follows: LC 1.X - Platform Static Offset (TMD off); LC 2.X - Platform Free-decays (TMD off); LC 3.X - Wave Cases (Regular Wave, Irregular Wave, Pink Noise Wave) with and without TMDs active. Detailed properties on the model system are found in the following reference: Lenfest E., Floating Offshore-wind Controls Advanced Laboratory (FOCAL) Experimental Program - Campaigns 2 and 3: 1:70 Model-scale Testing of the IEA-Wind 15MW Reference Turbine and the VolturnUS-S Hull. UMaine ASCC Report Number 23-56-1183.

17 WIND ENERGY↗

Simultaneous observations of giant pulses from pulsar PSR B0950+08 at 42 and 74 MHz

We report the detection of giant pulse (GP) emission from PSR B0950+08 in 12 hr of observations made simultaneously at 42 and 74 MHz, using the first station of the Long Wavelength Array. We detected 275 GPs (in 0.16% of the pulse periods) and 465 GPs (0.27%) at 42 and 74 MHz, respectively. The pulsar is weaker and produces less frequent GPs than at 100 MHz. Here, GPs are taken as having ⩾ 10 times the flux density of an average pulse (AP); their cumulative distribution of pulse strength follows a power law, with an index of −4.1 at 42 MHz and −5.1 at 74 MHz, which is much less steep than would be expected if we were observing the tail of a Gaussian distribution of normal pulses. We detected no other transient pulses in a wide dispersion measure range from 1 to 5000 pc cm{sup −3}. There were 128 GPs detected within the same periods from both 42 and 74 MHz, which means more than half of them are not generated in a wide band. The CLEAN-based algorithm was used to deconvolve the the effect of scattering broadening and we have concluded that the scattering effect from the interstellar medium at 42 and 74 MHz is weak and cannot be distinguished from the pulse profiles. We calculated the altitude r of the emission region using the dipolar magnetic field model. We found r(42 MHz) = 29.27 km (0.242% of R{sub LC}) and r(74 MHz) = 29.01 km (0.240% of R{sub LC}) for the AP, while for GPs, r(42 MHz) = 29.10 km (0.241% of R{sub LC}) and r(74 MHz) = 28.95 km (0.240% of R{sub LC}). GPs, which have a double-peak structure, have a smaller mean peak-to-peak separation compared to the AP.

79 ASTRONOMY AND ASTROPHYSICS↗

Pair-instability Supernova Simulations: Progenitor Evolution, Explosion, and Light Curves

In recent years, the viability of the pair-instability supernova (PISN) scenario for explaining superluminous supernovae has all but disappeared except for a few slowly-evolving examples. However, PISNe are not predicted to be superluminous throughout the bulk of their mass range. In fact, it is more likely that the first PISN we see (if we have not seen one already) will not be superluminous. Here, we present hydrodynamic simulations of PISNe for four stellar models with unique envelope properties spanning the PISN mass range. In addition, we compute synthetic light curves (LCs) for comparison with current and future observations. We also investigate, in the context of our most massive model, the prospect of mixing in the supernova ejecta, alleviating discrepancies between current PISN models and the remaining superluminous candidate events. To this end, we present the first published 3D hydrodynamic simulations of PISNe. After achieving convergence between 1D, 2D, and 3D simulations, we examine mixing in the supernova ejecta and its affect on the bolometric LC. We observe slight deviations from spherical symmetry, which increase with the number of dimensions. We find no significant effects on the bolometric LC; however, we conclude that mixing between the silicon and oxygen rich layers caused by the Rayleigh–Taylor instability may affect spectra.

79 ASTRONOMY AND ASTROPHYSICS↗

A Stochastic Approach to Reconstruct Gamma-Ray-burst Light Curves

Gamma-ray bursts (GRBs), as they are observed at high redshift ( z = 9.4), are vital to cosmological studies and investigating Population III stars. To tackle these studies, we need correlations among relevant GRB variables with the requirement of small uncertainties on their variables. Thus, we must have good coverage of GRB light curves (LCs). However, gaps in the LC hinder the precise determination of GRB properties and are often unavoidable. Therefore, extensive categorization of GRB LCs remains a hurdle. We address LC gaps using a stochastic reconstruction, wherein we fit two preexisting models (the Willingale model; W07; and a broken power law; BPL) to the observed LC, then use the distribution of flux residuals from the original data to generate data to fill in the temporal gaps. We also demonstrate a model-independent LC reconstruction via Gaussian processes. At 10% noise, the uncertainty of the end time of the plateau, its correspondent flux, and the temporal decay index after the plateau decreases by 33.3%, 35.03%, and 43.32% on average for the W07, and by 33.3%, 30.78%, 43.9% for the BPL, respectively. The uncertainty of the slope of the plateau decreases by 14.76% in the BPL. After using the Gaussian process technique, we see similar trends of a decrease in uncertainty for all model parameters for both the W07 and BPL models. These improvements are essential for the application of GRBs as standard candles in cosmology, for the investigation of theoretical models, and for inferring the redshift of GRBs with future machine-learning analyses.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluating lipid mediator structural complexity using ion mobility spectrometry combined with mass spectrometry

Lipid mediators (LMs) are broadly defined as a class of bioactive lipophilic molecules that regulate cell-to-cell communication events with many having a strong correlation with various human diseases and conditions. LMs are usually analyzed with liquid chromatography and mass spectrometry (LC-MS), but their numerous isomers greatly complicate the measurements with essentially identical fragmentation spectra and LC separations not always sufficient for distinguishing the features. Herein, we characterized LMs having specific categories using ion mobility spectrometry coupled with mass spectrometry (IMS-MS). The collision cross-sections and m/z values from the IMS and MS analyses displayed distinct trend lines. Specifically, the structural trend lines for sodiated LMs originating from docosahexaenoic acid had the smallest collision cross-section values in relation to m/z, while those from linoleic acid had the largest. LC–IMS–MS analyses were also performed on LMs in flu infected mouse tissue samples. These multidimensional studies were able to assess known LMs while also detecting new species. Adding IMS separations to conventional LC–MS analyses show great utility for enabling better identification and characterization of LMs in complex biological samples.

59 BASIC BIOLOGICAL SCIENCES↗

Comments on Lambeck and Coleman - 'The earth's shape and gravity field: A report of progress from 1958 to 1982'

The accuracy and validation of global gravity models based on satellite data are discussed, responding to the statistical analysis of Lambeck and Coleman (1983) (LC). Included are an evaluation of the LC error spectra, a summary of independent-observation calibrations of the error estimates of the Goddard Earth Models (GEM) 9 and L2 (Lerch et al., 1977, 1979, 1982, 1983, and 1985), a comparison of GEM-L2 with GRIM-3B (Reigber et al., 1983), a comparison of recent models with LAGEOS laser ranging, and a summary of resonant-orbit model tests. It is concluded that the accuracy of GEMs 9, 10, and L2 is much higher than claimed by LC, that the GEMs are in good agreement with independent observations and with GRIM-3B, and that the GEM calibrations were adequate. In a reply by LC, a number of specific questions regarding the error estimates are addressed, and it is pointed out that the intermodel discrepancies of the greatest geophysical interest are those in the higher-order coefficients, not discussed in the present comment. It is argued that the differences among the geoid heights of even the most recent models are large enough to call for considerable improvements.

Lerch, F. J.↗

Orthostatic intolerance during a 13-day bed rest does not result from increased leg compliance

Increased leg compliance (LC) has been proposed as a mechanism for orthostatic intolerance after spaceflight or bed rest. Using venous occlusion plethysmography with mercury-in-Silastic strain gauge, we evaluated LC before, during, and after a 13-day head-down bed rest in 10 men. LC was measured by the relationship between the increased calf areas at thigh cuff occlusions of 20, 30, 50, 70, and 80 mmHg. Orthostatic tolerance was evaluated by a presyncopal-limited lower body negative pressure test before and after bed rest. The 10 subjects were divided into TOL (n= 5) and INT (n=5) groups for which the orthostatic tolerance was similar and lower after bed rest, respectively. For TOL (INT) before bed rest, calf area increases were 2.2 +/- 0.5 (SE) (1.3 +/- 0.4), 3.5 +/- 0.7 (2.3 +/- 0.5), 5.0 +/- 0.9 (3.5 +/- 0.6), 5.6 +/- 0.9 (4.4 +/- 0.6), and 6.4 +/- 1.1 (4.7 +/- 0.6) sq cm for thigh occlusion pressures of 20, 30, 50, 70, and 80 mmHg, respectively. Neither for INT nor for TOL were these results significantly changed by bed rest. These results suggest that other mechanisms than increased LC have to be taken into account to explain the decreased orthostatic tolerance induced by this 13-day bed rest.

Melchior, Francois M.↗

Rayleigh Scattering Measurements Using a Tunable Liquid Crystal Fabry-Perot Interferometer

Spectroscopic Rayleigh scattering is an established flow diagnostic that has the ability to provide simultaneous density, velocity, and temperature measurements. The Fabry-Perot interferometer or etalon is a commonly employed instrument for resolving the spectrum of molecular Rayleigh scattered light for the purpose of evaluating these flow properties. This paper investigates the use of a tunable liquid crystal (LC) Fabry-Perot etalon in Rayleigh scattering experiments at NASA Glenn Research Center. The LC etalon provides a robust interferometry system that can be tuned rapidly by adjusting the voltage applied to the liquid crystal interface. Tuning the interferometer is often necessary to control the physical locations of the concentric interference fringes when Rayleigh light is imaged through the LC etalon. The LC etalon diagnostic system was tested in a 1-cm diameter nozzle flow in two different scattering configurations to evaluate its usefulness for Rayleigh measurements compared to a traditional non-tunable fused silica Fabry-Perot etalon.

Mielke-Fagan, Amy F.↗

Wind Flow Simulation Around NASA KSC Vehicle Assembly Building

A model of the wind flow conditions around Kennedy Space Center (KSC) Vehicle Assembly Building (VA B) is presented. An incompressible Navier-Stokes flow solver was used to compute the flow field around fixed Launch Complex 39 (LC-39) buildings and structures. The 3-D flow field. including velocity magnitude and velocity vectors, was established to simulate the localized wind speeds and directions at specified locations in and around LC-39 buildings and structures. The results of this study not only help explain the physical phenomena of the flow patterns around LC-39 buildings but also are useful to the Shuttle personnel. Current Operations and Maintenance Requirements and Specifications (OMRS) for vehicle transfer operations are based on empirically derived historical data, and no detailed mathematical analysis of wind conditions around LC-39 structures has ever been accomplished.

Vu, B. T.↗

Probabilistic Survivability Versus Time Modeling

This technical paper documents Kennedy Space Centers Independent Assessment team work completed on three assessments for the Ground Systems Development and Operations (GSDO) Program to assist the Chief Safety and Mission Assurance Officer (CSO) and GSDO management during key programmatic reviews. The assessments provided the GSDO Program with an analysis of how egress time affects the likelihood of astronaut and worker survival during an emergency. For each assessment, the team developed probability distributions for hazard scenarios to address statistical uncertainty, resulting in survivability plots over time. The first assessment developed a mathematical model of probabilistic survivability versus time to reach a safe location using an ideal Emergency Egress System at Launch Complex 39B (LC-39B); the second used the first model to evaluate and compare various egress systems under consideration at LC-39B. The third used a modified LC-39B model to determine if a specific hazard decreased survivability more rapidly than other events during flight hardware processing in Kennedys Vehicle Assembly Building (VAB).Based on the composite survivability versus time graphs from the first two assessments, there was a soft knee in the Figure of Merit graphs at eight minutes (ten minutes after egress ordered). Thus, the graphs illustrated to the decision makers that the final emergency egress design selected should have the capability of transporting the flight crew from the top of LC 39B to a safe location in eight minutes or less. Results for the third assessment were dominated by hazards that were classified as instantaneous in nature (e.g. stacking mishaps) and therefore had no effect on survivability vs time to egress the VAB. VAB emergency scenarios that degraded over time (e.g. fire) produced survivability vs time graphs that were line with aerospace industry norms.

Joyner, James J., Sr.↗

The North Galactic Pole Rift and the Local Hot Bubble

The North Galactic Pole Rift (NGPR) is one of the few distinct neutral hydrogen clouds at high Galactic latitudes that have well-defined distances. It is located at the edge of the Local Cavity (LC) and provides an important test case for understanding the Local Hot Bubble (LHB), the presumed location for the hot diffuse plasma responsible for much of the observed 1/4 keV emission originating in the solar neighborhood. Using data from the ROSAT All- Sky Survey and the Planck reddening map, we find the path length within the LC (LHB plus Complex of Local Interstellar Clouds) to be 98 plus or minus 27 pc, in excellent agreement with the distance to the NGPR of 98 +/- 6 pc. In addition, we examine another 14 directions that are distributed over the sky where the LC wall is apparently optically thick at 1/4 keV. We find that the data in these directions are also consistent with the LHB model and a uniform emissivity plasma filling most of the LC.

ISM: bubbles aEuro" ISM: clouds aEuro" ISM: magnet↗

A Quantitative Risk-Benefit Analysis of Prophylactic Surgery Prior to Extended-Duration Spaceflight

INTRODUCTION: Among otherwise healthy astronauts undertaking deep space missions, the risks for acute appendicitis (AA) and cholecystitis (AC) are not zero. If these conditions were to occur during spaceflight they may require surgery for definitive care. The proposed study quantifies and compares the risks of developing de novo AA and AC in-flight to the surgical risks of prophylactic laparoscopic appendectomy (LA) and cholecystectomy (LC) using NASA's Integrated Medical Model (IMM). METHODS: The IMM is a Monte Carlo simulation that forecasts medical events during spaceflight missions and estimates the impact of these medical events on crew health. In this study, four Design Reference Missions (DRMs) were created to assess the probability of an astronaut developing in-flight small-bowel obstruction (SBO) following prophylactic 1) LA, 2) LC, 3) LA and LC, or 4) neither surgery (SR# S-20160407-351). Model inputs were drawn from a large, population-based 2011 Swedish study that examined the incidence and risks of post-operative SBO over a 5-year follow-up period. The study group included 1,152 patients who underwent LA, and 16,371 who underwent LC. RESULTS: Preliminary results indicate that prophylactic LA may yield higher mission risks than the control DRM. Complete analyses are pending and will be subsequently available. DISCUSSION: The risk versus benefits of prophylactic surgery in astronauts to decrease the probability of acute surgical events during spaceflight has only been qualitatively examined in prior studies. Within the assumptions and limitations of the IMM, this work provides the first quantitative guidance that has previously been lacking to this important question for future deep space exploration missions.

Carroll, Danielle↗