Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

The many-body expansion for aqueous systems revisited: III. Hofmeister ion – water interactions

We report a Many Body Energy (MBE) analysis of aqueous ionic clusters containing anions and cations at the two opposite ends of the Hofmeister series, viz. the kosmotropes Ca2+, SO42- and chaotropes NH4+ and ClO4- with 9 water molecules to quantify the how these ions in altering the interaction between the water molecules in their immediate surrounding. The current results are contrasted to the ones reported earlier for water clusters as well as for alkali metal and halide ion aqueous clusters of the same size, which lie in the middle of the Hofmeister series. Through this analysis, noteworthy differences between the MBE of kosmotropes and chaotropes were identified. The MBE of kosmotropes is dominated by ion-water interactions that extends beyond the 4-body term, the point at which the MBE of pure water converges. The percentage contribution of the 2- B to the total cluster binding energy is noticeably larger. The disruption due to the dominant ion results in weak, unfavorable water-water interactions. The MBE for chaotropes, on the other hand, was found to converge more quickly as it more closely resembles that of pure water clusters. Chaotropes exhibit weaker overall binding energies and ion-water interactions with more favorable water-water interactions, somewhat recovering the pattern of the 2-4 body terms exemplified by pure water clusters. More importantly, both kosmotropic and chaotropic ions exhibit an anticorrelation between the 2-B ion-water (I-W) and water-water (W-W) interactions as well as between the 3-B (I-W-W) and (I-W) interactions. The consideration of two different structural arrangements (ion inside and outside of a water cluster) suggests that fully solvated (ion inside) chaotropes disrupt the hydrogen bonding network in a similar manner as partially solvated (ion outside) kosmotropes and offer useful insights into the modeling requirements of bulk vs. an interface. Finally, the 2-B contribution to the total Basis Set Superposition Error (BSSE) correction for the kosmotropic and chaotropic ions follows the previously reported erf profile vs. intermolecular distance. When scaled for the corresponding dimer energies and distances, a single profile fits the current results together with all previously reported ones for the pure water and halide water clusters.

Herman, Kristina M.↗

Measurements of the effective electron density in an electron beam ion trap using extreme ultraviolet spectra and optical imaging

In an electron beam ion trap (EBIT), the ions are not confined to the electron beam, but rather oscillate in and out of the beam. As a result, the ions do not continuously experience the full density of the electron beam. To determine the effective electron density, n e,eff , experienced by the ions, the electron beam size, the nominal electron density n e , and the ion distribution around the beam, i.e., the so-called ion cloud, must be measured. We use imaging techniques in the extreme ultraviolet (EUV) and optical to determine these. The electron beam width is measured using 3 d → 3 p emission from Fe xii and xiii between 185 and 205 Å. These transitions are fast and the EUV emission occurs only within the electron beam. The measured spatial emission profile and variable electron current yield a nominal electron density range of n e ~ 10 11 –10 13 cm –3 . We determine the size of the ion cloud using optical emission from metastable levels of ions with radiative lifetimes longer than the ion orbital periods. Here, the resulting emission maps out the spatial distribution of the ion cloud. We find a typical electron beam radius of ~60 μm and an ion cloud radius of ~300 μ m. These yield a spatially averaged effective electron density, ne,eff, experienced by the ions in EBIT spanning ~ 5 × 10 9 –5 × 10 11 cm –3 .

47 OTHER INSTRUMENTATION↗

Turbulent transport stabilization by ICRH minority fast ions in low rotating JET ILW L-mode plasmas

The first experimental demonstration that fast ion induced stabilization of thermal turbulent transport takes place also at low values of plasma toroidal rotation has been obtained in JET ILW (ITER-like wall) L-mode plasmas with high ( 3 He)-D ICRH (ion cyclotron resonance heating) power. A reduction of the gyro-Bohm normalized ion heat flux and higher values of the normalized ion temperature gradient have been observed at high ICRH power and low NBI (neutral beam injection) power and plasma rotation. Gyrokinetic simulations indicate that ITG (ion temperature gradient) turbulence stabilization induced by the presence of high-energetic 3 He ions is the key mechanism in order to explain the experimental observations. Two main mechanisms have been identified to be responsible for the turbulence stabilization: a linear electrostatic wave-fast particle resonance mechanism and a nonlinear electromagnetic mechanism. The dependence of the stabilization on the 3 He distribution function has also been studied.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On the role of ion temperature gradient turbulence in driving ion thermal transport in neutral beam injection-heated L-mode plasmas in a superconducting tokamak

In this paper, we report a detailed experimental study of the role of ion-temperature-gradient driven turbulence in driving ion thermal transport in neutral beam injection (NBI)-heated L-mode plasmas in Experimental Advanced Superconducting Tokamak (EAST) (Wan et al 2000 Nucl. Fusion 40 1057) coupled with linear and nonlinear gyrokinetic simulations. Significant ion-scale turbulence k ⟂ < cm −1 (k ⟂ < 1.5, where k ⟂ where is the perpendicular wavenumber and ρ s is the ion gyroradius calculated using local electron temperature T e ), measured with a microwave reflectometer, is observed in the plasma core at for r/a ≈ 0.265 and 0.5 (where r is half the diameter of the closed flux surface at a given radial position, and a is half the diameter of the last closed flux surface). Local linear stability analysis with experimental equilibrium quantities at these two radial locations using the GS2 gyrokinetic code shows that the most unstable ion-scale micro-instability is the ion temperature gradient (ITG) mode. Since the computed maximum ion-scale linear growth rates are larger than the local Waltz-Miller E × B shearing rate (Waltz and Miller 1999 Phys. Plasmas 6 4265), the E × B shear is unable to suppress ion-scale turbulence, consistent with the experimental observation of ion-scale turbulence. Experimental ion and electron thermal transports, calculated with power balance analysis, are both anomalous with ion thermal transport being the dominant channel. Nonlinear gyrokinetic simulations using the electrostatic global particle-in-cell gyrokinetic tokamak simulation (GTS) code (Weixing Wang et al 2010 Phys. Plasmas 17 072511) show good quantitative agreement between predicted ion thermal transport and that from the power balance analysis. These results demonstrate for the first time the important role of ITG turbulence in driving thermal transport in NBI-heated L-mode plasmas in EAST, showing the effectiveness of GTS code in simulating electrostatic turbulence in EAST and the need of suppressing ITG turbulence to improve energy confinement in EAST.

Sun, P. J. [Chinese Academy of Sciences (CAS), Hef↗

Room-temperature cycling of metal fluoride electrodes: Liquid electrolytes for high-energy fluoride ion cells

Fluoride ion batteries are potential “next-generation” electrochemical storage devices that offer high energy density. At present, such batteries are limited to operation at high temperatures because suitable fluoride ion–conducting electrolytes are known only in the solid state. We report a liquid fluoride ion–conducting electrolyte with high ionic conductivity, wide operating voltage, and robust chemical stability based on dry tetraalkylammonium fluoride salts in ether solvents. Pairing this liquid electrolyte with a copper–lanthanum trifluoride (Cu@LaF 3 ) core-shell cathode, we demonstrate reversible fluorination and defluorination reactions in a fluoride ion electrochemical cell cycled at room temperature. Fluoride ion–mediated electrochemistry offers a pathway toward developing capacities beyond that of lithium ion technology.

Davis, Victoria K.↗

Stochastic Ion Acceleration by the Ion-cyclotron Instability in a Growing Magnetic Field

Using 1D and 2D particle-in-cell simulations of a plasma with a growing magnetic field ${\boldsymbol{B}}$, we show herein that ions can be stochastically accelerated by the ion-cyclotron (IC) instability. As ${\boldsymbol{B}}$ grows, an ion pressure anisotropy ${p}_{\perp ,i}\gt {p}_{| | ,i}$ arises due to the adiabatic invariance of the ion magnetic moment (${p}_{| | ,i}$ and $p_{⊥,i}$ are the ion pressures parallel and perpendicular to ${\boldsymbol{B}}$). When initially $β_ i$ = 0.5 (${\beta }_{i}\equiv 8\pi {p}_{i}/| {\boldsymbol{B}}{| }^{2}$, where $p_i$ is the ion isotropic pressure), the pressure anisotropy is limited mainly by inelastic pitch-angle scattering provided by the IC instability, which in turn produces a nonthermal tail in the ion energy spectrum. After ${\boldsymbol{B}}$ is amplified by a factor of ~2.7, this tail can be approximated as a power law of index ~3.4 plus two nonthermal bumps and accounts for 2%–3% of the ions and ~18% of their kinetic energy. On the contrary, when initially $β_i$ = 2, the ion scattering is dominated by the mirror instability, and the acceleration is suppressed. This implies that efficient ion acceleration requires that initially, $β_{i} \lesssim$ 1. Although we focus on cases where ${\boldsymbol{B}}$ is amplified by plasma shear, we check that the acceleration occurs similarly if ${\boldsymbol{B}}$ grows due to plasma compression. Our results are valid in a subrelativistic regime where the ion thermal energy is ~10% of the ion rest-mass energy. This acceleration process can thus be relevant in the inner region of low-luminosity accretion flows around black holes.

79 ASTRONOMY AND ASTROPHYSICS↗

Alfven ion-cyclotron heating of ionospheric O(+) ions

Transversely heated ionospheric ions, in particular O(+) ions, are often observed flowing upward along auroral field lines. Currents observed in association with the transversely heated ions can drive shear Alfven waves and electrostatic ion-cyclotron waves unstable which can, in turn, be resonantly absorbed by the ions to produce the heating. Particle simulations are used to examine self-consistently the excitation of these waves and the associated heating. It is shown that the growth of the electrostatic ion-cyclotron waves quickly becomes suppressed as the ions become heated and the dominant wave fields are those of the shear Alfven wave. The resultant transverse ion heating is larger and faster than that produced by solely electrostatic ion-cyclotron wave heating. Due to trapping of ions by the shear Alfven wave, the temperature of the O(+) ions remains comparable to that of the H(+) ions.

Winglee, R. M.↗

High Mass Ion Detection with Charge Detector Coupled to Rectilinear Ion Trap Mass Spectrometer

Conventional linear ion trap mass analyzers (LIT-MS) provide high ion capacity and show their MS{sup n} ability; however, the detection of high mass ions is still challenging because LIT-MS with secondary electron detectors (SED) cannot detect high mass ions. To detect high mass ions, we coupled a charge detector (CD) to a rectilinear ion trap mass spectrometer (RIT-MS). Immunoglobulin G ions (m/z ~150,000) are measured successfully with controlled ion kinetic energy. In addition, when mass-to-charge (m/z) ratios of singly charged ions exceed 10 kTh, the detection efficiency of CD is found to be greater than that of SED. The CD can be coupled to LIT-MS to extend the detection mass range and provide the potential to perform MS{sup n} of high mass ions inside the ion trap. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Versatile system for ion energy measurements generated by pulsed laser ionization: Insights into electron-ion dynamics

Ion energy distributions generated by pulsed laser interactions with materials are essential for applications ranging from materials science to oncology. Ion energy characterization is particularly important for an emerging mass spectrometry technique called virtual-slit cycloidal mass spectrometry (VS-CMS). The ion energy distribution influences the design and performance of VS-CMS instruments, as well as the efficacy of laser-driven ionization methods in various fields. Several established techniques, including the retarding potential method, time-of-flight (TOF) analysis, and electrostatic energy analyzers, have been employed to measure ion energy distributions. The wide range of ion energies reported highlights the strong dependence of ion energy on laser parameters, target materials, and experimental conditions, as well as the necessity of making independent measurements of the ion energy distribution for specific laser systems and materials. This paper presents the design and characterization of a simple TOF-based apparatus for measuring ion energy distributions from pulsed laser ionization without external fields. This approach minimizes perturbation of electron-ion dynamics and enables simultaneous energy measurements at multiple spatial positions. Here, the apparatus was tested using a nanosecond pulsed Nd:YAG laser operating at 1064 nm, 532 nm, and 266 nm on solid copper sheets at various laser fluences. Simultaneous measurements at different distances provide new insights into ion-electron interactions post-ionization and demonstrate the influence of laser wavelength and fluence on ion energy distributions.

Ion energy↗

Ion optics of RHIC electron beam ion source

RHIC electron beam ion source has been commissioned to operate as a versatile ion source on RHIC injection facility supplying ion species from He to Au for Booster. Except for light gaseous elements RHIC EBIS employs ion injection from several external primary ion sources. With electrostatic optics fast switching from one ion species to another can be done on a pulse to pulse mode. The design of an ion optical structure and the results of simulations for different ion species are presented. In the choice of optical elements special attention was paid to spherical aberrations for high-current space charge dominated ion beams. The combination of a gridded lens and a magnet lens in LEBT provides flexibility of optical control for a wide range of ion species to satisfy acceptance parameters of RFQ. The results of ion transmission measurements are presented.

43 PARTICLE ACCELERATORS↗

The positive ion temperature effect in magnetized electronegative plasma sheath with two species of positive ions

The properties of a magnetized multi-component (two species of positive ions, negative ions and electrons) plasma sheath with finite positive ion temperature are studied. By using three fluid hydrodynamic model and some dimensionless variables, the ion (both lighter and heavier positive ions, and negative ions) densities, the ion (only for positive ions) velocities, and electric potential inside the sheath are investigated. In addition, the absence and presence of magnetic field and the orientation of magnetic field are considered. It is noticed that, with increase of positive ion temperature, the lighter positive ion density peaks increase only at the sheath edge and shift towards the sheath edge for both absence and presence of magnetic field. For heavier positive ions, in the absence of magnetic field, the density peaks increase at the sheath edge. But in the presence of magnetic field, the density fluctuations increase at the sheath edge. For both the cases, the density peaks shift towards the sheath edge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On the role of ion-based imaging methods in modern ion beam therapy

External beam radiotherapy techniques have the common aim to maximize the radiation dose to the target while sparing the surrounding healthy tissues. The inverted and finite depth-dose profile of ion beams (Bragg peak) allows for precise dose delivery and conformai dose distribution. Furthermore, increased radiobiological effectiveness of ions enhances the capability to battle radioresistant tumors. Ion beam therapy requires a precise determination of the ion range, which is particularly sensitive to range uncertainties. Therefore, novel imaging techniques are currently investigated as a tool to improve the quality of ion beam treatments. Approaches already clinically available or under development are based on the detection of secondary particles emitted as a result of nuclear reactions (e.g., positron-annihilation or prompt gammas, charged particles) or transmitted high energy primary ion beams. Transmission imaging techniques make use of the beams exiting the patient, which have higher initial energy and lower fluence than the therapeutic ones. At the Heidelberg Ion Beam Therapy Center, actively scanned energetic proton and carbon ion beams provide an ideal environment for the investigation of ion-based radiography and tomography. This contribution presents the rationale of ion beam therapy, focusing on the role of ion-based transmission imaging methods towards the reduction of range uncertainties and potential improvement of treatment planning.

60 APPLIED LIFE SCIENCES↗

Liquid metal alloy ion sources—An alternative for focussed ion beam technology

Today, Focused Ion Beam (FIB) processing is nearly exclusively based on gallium Liquid Metal Ion Sources (LMIS). But, many applications in the μm- or nm range could benefit from ion species other than gallium: local ion implantation, ion beam mixing, ion beam synthesis, or Focused Ion Beam Lithography (IBL). Therefore, Liquid Metal Alloy Ion Sources (LMAIS) represent a promising alternative to expand the remarkable application fields for FIB. Especially, the IBL process shows potential advantages over, e.g., electron beam or other lithography techniques: direct, resistless, and three-dimensional patterning, enabling a simultaneous in-situ process control by cross-sectioning and inspection. Taking additionally into account that the used ion species influences significantly the physical and chemical nature of the resulting nanostructures—in particular, the electrical, optical, magnetic, and mechanic properties leading to a large potential application area which can be tuned by choosing a well suited LMAIS. Nearly half of the elements of the periodic table are recently available in the FIB technology as a result of continuous research in this area during the last forty years. Key features of a LMAIS are long life-time, high brightness, and stable ion current. Recent developments could make these sources feasible for nano patterning issues as an alternative technology more in research than in industry. The authors will review existing LMAIS, LMIS other than Ga, and binary and ternary alloys. These physical properties as well as the fabrication technology and prospective domains for modern FIB applications will similarly be reviewed. Other emerging ion sources will be also presented and their performances discussed.

36 MATERIALS SCIENCE↗

Comparison of gain degradation and deep level transient spectroscopy in pnp Si bipolar junction transistors irradiated with different ion species

Here, we studied the effect of light ion and heavy ion irradiations on pnp Si BJTs. A mismatch in DLTS deep peak amplitude for devices with same final gain but irradiated with different ion species was observed. Also, different ions cause different gain degradation when the DLTS spectra are matched. Pre-dosed ion-irradiated samples show that ion induced ionization does not account for the differences in DLTS peak height but isochronal annealing studies suggest that light ions produce more VP defects than heavy ions to compensate for the lack of clusters that heavy ions produce. The creation of defect clusters by heavy ions is evident by the higher content of E4 and V* 2 defects compared to light ions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Computation of methodology-independent single-ion solvation properties from molecular simulations. IV. Optimized Lennard-Jones interaction parameter sets for the alkali and halide ions in water

The raw single-ion solvation free energies computed from atomistic (explicit-solvent) simulations are extremely sensitive to the boundary conditions and treatment of electrostatic interactions used during these simulations. However, as shown recently [M. A. Kastenholz and P. H. Huenenberger, J. Chem. Phys. 124, 224501 (2006); M. M. Reif and P. H. Huenenberger, J. Chem. Phys. 134, 144103 (2010)], the application of appropriate correction terms permits to obtain methodology-independent results. The corrected values are then exclusively characteristic of the underlying molecular model including in particular the ion-solvent van der Waals interaction parameters, determining the effective ion size and the magnitude of its dispersion interactions. In the present study, the comparison of calculated (corrected) hydration free energies with experimental data (along with the consideration of ionic polarizabilities) is used to calibrate new sets of ion-solvent van der Waals (Lennard-Jones) interaction parameters for the alkali (Li{sup +}, Na{sup +}, K{sup +}, Rb{sup +}, Cs{sup +}) and halide (F{sup -}, Cl{sup -}, Br{sup -}, I{sup -}) ions along with either the SPC or the SPC/E water models. The experimental dataset is defined by conventional single-ion hydration free energies [Tissandier et al., J. Phys. Chem. A 102, 7787 (1998); Fawcett, J. Phys. Chem. B 103, 11181] along with three plausible choices for the (experimentally elusive) value of the absolute (intrinsic) hydration free energy of the proton, namely, {Delta}G{sub hyd} {sup O-minus} [H{sup +}]=-1100, -1075 or -1050 kJ mol{sup -1}, resulting in three sets L, M, and H for the SPC water model and three sets L{sub E}, M{sub E}, and H{sub E} for the SPC/E water model (alternative sets can easily be interpolated to intermediate {Delta}G{sub hyd} {sup O-minus} [H{sup +}] values). The residual sensitivity of the calculated (corrected) hydration free energies on the volume-pressure boundary conditions and on the effective ionic radius entering into the calculation of the correction terms is also evaluated and found to be very limited. Ultimately, it is expected that comparison with other experimental ionic properties (e.g., derivative single-ion solvation properties, as well as data concerning ionic crystals, melts, solutions at finite concentrations, or nonaqueous solutions) will permit to validate one specific set and thus, the associated {Delta}G{sub hyd} {sup O-minus} [H{sup +}] value (atomistic consistency assumption). Preliminary results (first-peak positions in the ion-water radial distribution functions, partial molar volumes of ionic salts in water, and structural properties of ionic crystals) support a value of {Delta}G{sub hyd} {sup O-minus} [H{sup +}] close to -1100 kJ{center_dot}mol{sup -1}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Numerical study of the characteristics of the ion and fast atom beams in an end-Hall ion source

An end-Hall ion source is a cylindrical magnetized device of few centimeters in length able to generate an ion beam with a current of typically 1 A and ion energies in the range of 100 eV. This ion source does not use acceleration grids, has a relatively large ion beam divergence, and is well suited for ion assisted deposition processes. In this paper, a self-consistent two-dimensional quasi-neutral model of an end-Hall ion source is used to understand the parameters controlling the characteristics of the extracted. The model results underline the role of charge exchange collisions on beam properties. The calculated energy distribution functions reveal the existence of groups of slow ions and fast neutrals. Ion mean energy corresponds to roughly 60% of the discharge voltage, while the root mean square deviation from the mean energy corresponds to about 33% of the discharge voltage, as in experiments. The influence of the position of the electron emitting source on the ion angular distribution is also shown.

43 PARTICLE ACCELERATORS↗

Ion irradiation of Fe-Fe oxide core-shell nanocluster films: Effect of interface on stability of magnetic properties

A cluster deposition method was used to produce films of loosely aggregated nanoclusters (NCs) of Fe core-Fe{sub 3}O{sub 4} shell or fully oxidized Fe{sub 3}O{sub 4}. Films of these NC on Si(100) or MgO(100)/Fe{sub 3}O{sub 4}(100) were irradiated to 10{sup 16} Si{sup 2+}/cm{sup 2} near room temperature using an ion accelerator. Ion irradiation creates structural change in the NC film with corresponding chemical and magnetic changes which depend on the initial oxidation state of the cluster. Films were characterized using magnetometry (hysteresis, first order reversal curves), microscopy (transmission electron, helium ion), and x-ray diffraction. In all cases, the particle sizes increased due to ion irradiation, and when a core of Fe is present, irradiation reduces the oxide shells to lower valent Fe species. These results show that ion irradiated behavior of the NC films depends strongly on the initial nanostructure and chemistry, but in general saturation magnetization decreases slightly.

36 MATERIALS SCIENCE↗

Average charge and its structure dependence of fragment ions under irradiation of a thin carbon foil with a 1-MeV/atom C{sub 3}{sup +} cluster ion

The charge states of fragment ions were measured for 1-MeV/atom C{sub 3}{sup +} cluster ions penetrating a carbon foil of 2.4-{mu}g/cm{sup 2} thickness. Those ions were detected by event-by-event mode with a fluorescent screen detector monitored by a charge-coupled device camera. The detected ion signals were traced by Coulomb explosion imaging technique, which enables us to classify charge states of each fragment ion and spatial arrangements of aligned cluster ions after emerging from the foil. Using this technique, we found the reduction of the average charge per ion. We also found that (i) the measured average charges of the aligned fragment ions in a linear-chain arrangement are larger than those in a triangular arrangement, and (ii) the edge-position ions in a linear-chain arrangement have the average charges greater than the middle-position ion. These experimental results are well supported by a recent refined theory on the cluster average charge.

74 ATOMIC AND MOLECULAR PHYSICS↗