Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Insulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Results of Speciation Determination Measurements of Insulating Sulfur Hexafluoride Gas

Under the direction of the NNSA NA-231 Mo-99 Program, SRNL has provided technical assistance to U.S. companies under cooperative agreements. One such area of technical assistance has been for the recommendation for contamination management methods in the eventuality that tritium contaminates the insulating gas of a high-voltage ion source used in the accelerator-based process developed by SHINE Medical Technologies to produce Mo-99. The SHINE accelerator process uses tritium as the target of a deuterium ion beam, where the ion beam is produced within a high-voltage ion source insulated with sulfur hexafluoride (SF 6 ), and is separated from the tritium target by an extensive pump train. Normal operating conditions preclude the conditions necessary for contamination of the insulating gas, however certain atypical conditions could result in a tritium contamination event. Accelerator based processes for medical isotope production represent an anomalous tritium contamination challenge due to the presence of SF 6 . SF 6 decomposes through normal use as an insulator gas, and the exact speciation of the decomposition byproducts depends on a variety of factors. This creates a scenario where the anticipation of species present in the insulating gas mixture is difficult. In turn, the fate of tritium within such a chemical system is unclear. This document discusses the results of measurements made in-situ of the SF 6 insulating gas in use within a SHINE Medical Technology’s high-voltage ion source. This was done in an effort to determine the chemical speciation of the gas, allowing for the recommendation of management strategies in the event that tritium contaminates the insulating gas. The results of the measurements reported in this work suggest that tritium contamination in the insulating gas may result in two chemical forms of tritium in the system, tritiated water and molecular tritium. These two forms of tritium would be captured by two methods. Tritiated water may be captured and removed from the SF 6 by an adsorbent canister already present within the pressure vessel that houses the insulating gas while in use. It may also be separated from the SF 6 during routine purification of the SF 6 , which is performed by SHINE personnel routinely. The purification cart will perform all non-embedded systems cleanup necessary to remediate tritiated species in the system. The purification cart passes the insulating gas through several filters, followed by the liquefication of the SF 6 . The filters will separate tritiated water from the SF 6 at this stage. It is expected that molecular tritium will accumulate in the gas-phase during the liquification step, which is separated and stored. Tritium may be recovered from this mixture through more conventional hydrogen purification methods such as a palladium diffuser.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Electron Emission Properties of Insulator Materials Pertinent to the International Space Station

We present the results of our measurements of the electron emission properties of selected insulating and conducting materials used on the International Space Station (ISS). Utah State University (USU) has performed measurements of the electron-, ion-, and photon-induced electron emission properties of conductors for a few years, and has recently extended our capabilities to measure electron yields of insulators, allowing us to significantly expand current spacecraft material charging databases. These ISS materials data are used here to illustrate our various insulator measurement techniques that include: i) Studies of electron-induced secondary and backscattered electron yield curves using pulsed, low current electron beams to minimize deleterious affects of insulator charging. ii) Comparison of several methods used to determine the insulator 1st and 2nd crossover energies. These incident electron energies induce unity total yield at the transition between yields greater than and less than one with either negative or positive charging, respectively. The crossover energies are very important in determining both the polarity and magnitude of spacecraft surface potentials. iii) Evolution of electron emission energy spectra as a function of insulator charging used to determine the surface potential of insulators. iv) Surface potential evolution as a function of pulsed-electron fluence to determine how quickly insulators charge, and how this can affect subsequent electron yields. v) Critical incident electron energies resulting in electrical breakdown of insulator materials and the effect of breakdown on subsequent emission, charging and conduction. vi) Charge-neutralization techniques such as low-energy electron flooding and UV light irradiation to dissipate both positive and negative surface potentials during yield measurements. Specific ISS materials being tested at USU include chromic and sulfuric anodized aluminum, RTV-silicone solar array adhesives, solar cell cover glasses, Kapton, and gold. Further details of the USU testing facilities, the instrumentation used for insulator measurements, and the NASA/SEE Charge Collector materials database are provided in other Spacecraft Charging Conference presentations (Dennison, 2003b). The work presented was supported in part by the NASA Space Environments and Effects (SEE) Program, the Boeing Corporation, and a NASA Graduate Fellowship. Samples were supplied by Boeing, the Environmental Effects Group at Marshall Space Flight Center, and Sheldahl, Inc.

Thomson, C. D.↗

Rise and fall of Mott insulating gaps in YNiO 3 paramagnets as a reflection of symmetry breaking and remaking

The YNiO 3 nickelate is a paradigm d-electron oxide that manifests the intriguing temperature-mediated sequence of three phases transitions from (i) magnetically ordered insulator to (ii) paramagnetic (PM) insulator and then to (iii) PM metal. Such phenomena raised the question of the nature of the association of magnetism and structural symmetry breaking with the appearance in (i) and (ii) and disappearance in (iii) of insulating band gaps. It is demonstrated here that first-principles mean-field–like density-functional theory (DFT), driven by molecular dynamics temperature evolution, can describe not only the origin of the magnetically long-range ordered insulating phase (i), but also the creation of an insulating paramagnet (ii) that lacks spin- long-range order, and of a metallic paramagnet (iii) as temperature rises. This approach provides the patterns of structural and magnetic symmetry breaking at different temperatures, in parallel with band gaps obtained when the evolving geometries are used as input to DFT electronic band-structure calculations. This disentangles the complex interplay among spin, charge, and orbital degrees of freedom. Analysis shows that the success in describing the rise and fall of the insulating band gaps along the phase transition sequence is enabled by allowing sufficient flexibility in describing diverse local structural and magnetic motifs as input to DFT. This entails the use of sufficiently large supercells that allow expressing structural disproportionation of octahedra, as well as a description of PM phases as a distribution of local magnetic moments (rather than using a single averaged moment). It appears that the historic dismissal of mean-field–like DFT as being unable to describe such Mott-like transitions was premature, as it was based on consideration of averaged crystallographic unit cells, a description that washes out local symmetry-breaking motifs. The magnetically ordered insulating YNiO 3 phase (i) and the PM insulating phase (ii) result in DFT from allowing symmetry breaking, evident already by considering the athermal internal energy. In contrast, the PM metallic phase (iii) is formed thermally by smearing out thus weakening symmetry breaking. Analysis of snapshots of the different forms of structural vs magnetic symmetry breaking shows that only the loss of the polymorphous distribution of magnetic moments existing in (ii) causes the fall of the band gap, resulting in the metallic state in (iii). Finally, the interesting conclusion is that such a description of the rise [in phases (i) and (ii)] and fall [in phase (iii)] of the insulating gap does not rely on the traditional Mott-like strong correlation understanding, but on breaking and remaking of magnetic and structural symmetries reflected in energy lowering.

36 MATERIALS SCIENCE↗

Theory and Simulation of Metal–Insulator–Semiconductor (MIS) Photoelectrodes

A metal–insulator–semiconductor (MIS) structure is an attractive photoelectrode-catalyst architecture for promoting photoelectrochemical reactions, such as the formation of H 2 by proton reduction. The metal catalyzes the generation of H 2 using electrons generated by photon absorption and charge separation in the semiconductor. The insulator layer between the metal and the semiconductor protects the latter element from photo-corrosion and, also, significantly impacts the photovoltage at the metal surface. Understanding how the insulator layer determines the photovoltage and what properties lead to high photovoltages is critical to the development of MIS structures for solar-to-chemical energy conversion. Herein, we present a continuum model for charge-carrier transport from the semiconductor to the metal with an emphasis on mechanisms of charge transport across the insulator. The polarization curves and photovoltages predicted by this model for a Pt/HfO 2 /p-Si MIS structure at different HfO 2 thicknesses agree well with experimentally measured data. The simulations reveal how insulator properties (i.e., thickness and band structure) affect band bending near the semiconductor/insulator interface and how tuning them can lead to operation closer to the maximally attainable photovoltage, the flat-band potential. This phenomenon is understood by considering the change in tunneling resistance with insulator properties. The model shows that the best MIS performance is attained with highly symmetric semiconductor/insulator band offsets (e.g., BeO, MgO, SiO 2 , HfO 2 , or ZrO 2 deposited on Si) and a low to moderate insulator thickness (e.g., between 0.8 and 1.5 nm). Beyond 1.5 nm, the density of filled interfacial trap sites is high and significantly limits the photovoltage and the solar-to-chemical conversion rate. These conclusions are true for photocathodes and photoanodes. This understanding provides critical insight into the phenomena enhancing and limiting photoelectrode performance and how this phenomenon is influenced by insulator properties. The study gives guidance toward the development of next-generation insulators for MIS structures that achieve high performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tuning the Chern number in quantum anomalous Hall insulators

A quantum anomalous Hall (QAH) state is a two-dimensional topological insulating state that has a quantized Hall resistance of h/(Ce 2 ) and vanishing longitudinal resistance under zero magnetic field (where h is the Planck constant, e is the elementary charge, and the Chern number C is an integer). The QAH effect has been realized in magnetic topological insulators and magic-angle twisted bilayer graphene. However, the QAH effect at zero magnetic field has so far been realized only for C = 1. Here we realize a well quantized QAH effect with tunable Chern number (up to C = 5) in multilayer structures consisting of alternating magnetic and undoped topological insulator layers, fabricated using molecular beam epitaxy. The Chern number of these QAH insulators is determined by the number of undoped topological insulator layers in the multilayer structure. Moreover, we demonstrate that the Chern number of a given multilayer structure can be tuned by varying either the magnetic doping concentration in the magnetic topological insulator layers or the thickness of the interior magnetic topological insulator layer. We develop a theoretical model to explain our experimental observations and establish phase diagrams for QAH insulators with high, tunable Chern number. Furthermore, the realization of such insulators facilitates the application of dissipationless chiral edge currents in energy-efficient electronic devices, and opens up opportunities for developing multi-channel quantum computing and higher-capacity chiral circuit interconnects.

36 MATERIALS SCIENCE↗

Axion Insulator State in a Ferromagnet/Topological Insulator/Antiferromagnet Heterostructure

We propose the use of ferromagnetic insulator MnBi 2 Se 4 /Bi 2 Se 3 /antiferromagnetic insulator Mn 2 Bi 2 Se 5 heterostructures for the realization of the axion insulator state. Importantly, the axion insulator state in such heterostructures only depends on the magnetization of the ferromagnetic insulator and, hence, can be observed in a wide range of external magnetic fields. Using density functional calculations and model Hamiltonian simulations, we find that the top and bottom surfaces have opposite half-quantum Hall conductances, σ$^{t}_{xy}$ = e 2 /2h and σ$^{b}_{xy}$ = –e 2 /2h, with a sizable global spin gap of 5.1 meV opened for the topological surface states of Bi 2 Se 3 . Furthermore, our work provides a new strategy for the search of axion insulators by using van der Waals antiferromagnetic insulators along with three-dimensional topological insulators.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A New Generation of Building Insulation by Foaming Polymer Blend Materials with CO 2

Advanced thermal insulation is among the most effective technologies in transforming our nation’s energy system and contributing to DOE’s stated goal of 50% less building energy consumption by 2030. The installation of an advanced thermal insulation would prevent energy waste without the need for any maintenance, and ISTN conservatively estimates that the commercialization of such a new technology would contribute to annual U.S. energy savings of 0.361 Quads and $8 billion in annual economic savings. The key challenge to improving building insulation is to maintain and surpass the industry standard of R-5 per inch insulation value in a cost-competitive manner. Improvements in R-value without cost-efficiency are not likely to impact the market given the cost-sensitive nature of the construction industry (insulation is already the lowest-cost component of the building envelope). However, significantly higher insulating value at competitive costs is extremely appealing to the market given the greater potential to save on energy consumption and costs over the long-term. Thus, our goal is to develop a super-thermal insulation with 50% greater insulation value (R-9 to R-10 per inch) and manufacturing costs that are equal on a per-R-value basis (< $0.70/ft 2 ).

36 MATERIALS SCIENCE↗

Topological surface conduction in Kondo insulator YbB 12

Kondo insulators have recently aroused great interest because they are promising materials that host a topological insulator state caused by the strong electron interactions. Moreover, recent observations of the quantum oscillations in the insulating state of Kondo insulators have come as a great surprise. Here, we investigate the surface electronic state of a prototype Kondo insulator YbB 12 , we measured the transport properties of single crystals and microstructures. In all samples, the temperature dependence of the electrical resistivity is insulating at high temperatures and the resistivity exhibits a plateau at low temperatures. The magnitude of the plateau value decreases with reducing sample thickness, which is quantitatively consistent with the surface electronic conduction in the bulk insulating YbB 12 . Moreover, the magnetoresistance of the microstructures exhibits a weak-antilocalization effect at low field. These results are consistent with the presence of a topologically protected surface state, suggesting that YbB 12 is a candidate material for a topological Kondo insulator. The high field resistivity measurements up to µ 0 H = 50 T of the microstructures provide supporting evidence that the quantum oscillations of the resistivity in YbB 12 occurs in the insulating bulk.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nature and function of insulator protein binding sites in the Drosophila genome

Chromatin insulator elements and associated proteins have been proposed to partition eukaryotic genomes into sets of independently regulated domains. Here we test this hypothesis by quantitative genome-wide analysis of insulator protein binding to Drosophila chromatin. We find distinct combinatorial binding of insulator proteins to different classes of sites and uncover a novel type of insulator element that binds CP190 but not any other known insulator proteins. Functional characterization of different classes of binding sites indicates that only a small fraction act as robust insulators in standard enhancer-blocking assays. We show that insulators restrict the spreading of the H3K27me3 mark but only at a small number of Polycomb target regions and only to prevent repressive histone methylation within adjacent genes that are already transcriptionally inactive. RNAi knockdown of insulator proteins in cultured cells does not lead to major alterations in genome expression. Taken together, these observations argue against the concept of a genome partitioned by specialized boundary elements and suggest that insulators are reserved for specific regulation of selected genes.

59 BASIC BIOLOGICAL SCIENCES↗

A water blown urethane insulation for use in cryogenic environments

Thermal Protection Systems (TPS) of NASA's Space Shuttle External Tank include polyurethane and polyisocyanurate modified polyurethane foam insulations. These insulations, currently foamed with CFC 11 blowing agent, serve to maintain cryogenic propellant quality, maintain the external tank structural temperature limits, and minimize the formation of ice and frost that could potentially damage the ceramic insulation on the space shuttle orbiter. During flight the external tank insulations are exposed to mechanical, thermal and acoustical stresses. TPS must pass cryogenic flexure and substrate adhesion tests at -253 C, aerothermal and radiant heating tests at fluxes up to approximately 14 kilowatts per square meter, and thermal conductivity tests at cryogenic and elevated temperatures. Due to environmental concerns, the polyurethane insulation industry and the External Tank Project are tasked with replacing CFC 11. The flight qualification of foam insulations employing HCFC 141b as a foaming agent is currently in progress; HCFC 141b blown insulations are scheduled for production implementation in 1995. Realizing that the second generation HCFC blowing agents are an interim solution, the evaluation of third generation blowing agents with zero ozone depletion potential is underway. NASA's TPS Materials Research Laboratory is evaluating third generation blowing agents in cryogenic insulations for the External Tank; one option being investigated is the use of water as a foaming agent. A dimensionally stable insulation with low friability, good adhesion to cryogenic substrates, and acceptable thermal conductivity has been developed with low viscosity materials that are easily processed in molding applications. The development criteria, statistical experimental approach, and resulting foam properties will be presented.

Blevins, Elana↗

Combined Heat Transfer in High-Porosity High-Temperature Fibrous Insulations: Theory and Experimental Validation

Combined radiation and conduction heat transfer through various high-temperature, high-porosity, unbonded (loose) fibrous insulations was modeled based on first principles. The diffusion approximation was used for modeling the radiation component of heat transfer in the optically thick insulations. The relevant parameters needed for the heat transfer model were derived from experimental data. Semi-empirical formulations were used to model the solid conduction contribution of heat transfer in fibrous insulations with the relevant parameters inferred from thermal conductivity measurements at cryogenic temperatures in a vacuum. The specific extinction coefficient for radiation heat transfer was obtained from high-temperature steady-state thermal measurements with large temperature gradients maintained across the sample thickness in a vacuum. Standard gas conduction modeling was used in the heat transfer formulation. This heat transfer modeling methodology was applied to silica, two types of alumina, and a zirconia-based fibrous insulation, and to a variation of opacified fibrous insulation (OFI). OFI is a class of insulations manufactured by embedding efficient ceramic opacifiers in various unbonded fibrous insulations to significantly attenuate the radiation component of heat transfer. The heat transfer modeling methodology was validated by comparison with more rigorous analytical solutions and with standard thermal conductivity measurements. The validated heat transfer model is applicable to various densities of these high-porosity insulations as long as the fiber properties are the same (index of refraction, size distribution, orientation, and length). Furthermore, the heat transfer data for these insulations can be obtained at any static pressure in any working gas environment without the need to perform tests in various gases at various pressures.

Daryabeigi, Kamran↗

Nearly Seamless Vacuum-Insulated Boxes

A design concept, and a fabrication process that would implement the design concept, have been proposed for nearly seamless vacuum-insulated boxes that could be the main structural components of a variety of controlled-temperature containers, including common household refrigerators and insulating containers for shipping foods. In a typical case, a vacuum-insulated box would be shaped like a rectangular parallelepiped conventional refrigerator box having five fully closed sides and a hinged door on the sixth side. Although it is possible to construct the five-closed-side portion of the box as an assembly of five unitary vacuum-insulated panels, it is not desirable to do so because the relatively high thermal conductances of the seams between the panels would contribute significant amounts of heat leakage, relative to the leakage through the panels themselves. In contrast, the proposal would make it possible to reduce heat leakage by constructing the five-closed-side portion of the box plus the stationary portion (if any) of the sixth side as a single, seamless unit; the only remaining seam would be the edge seal around the door. The basic cross-sectional configuration of each side of a vacuum-insulated box according to the proposal would be that of a conventional vacuum-insulated panel: a low-density, porous core material filling a partially evacuated space between face sheets. However, neither the face sheets nor the core would be conventional. The face sheets would be opposite sides of a vacuum bag. The core material would be a flexible polymer-modified silica aerogel of the type described in Silica/Polymer and Silica/Polymer/Fiber Composite Aero - gels (MSC-23736) in this issue of NASA Tech Briefs. As noted in that article, the stiffness of this core material against compression is greater than that of prior aerogels. This is an important advantage because it translates to greater retention of thickness and, hence, of insulation performance when pressure is applied across the thickness, in particular, when the space between the face sheets is evacuated, causing the core material to be squeezed between the face sheets by atmospheric pressure. Fabrication of a typical vacuum-insulated box according to the proposal would begin with fabrication of a cross-shaped polymer-modified aerogel blanket. The dimensions of the cross would be chosen so that (1) the central rectangular portion of the cross would form the core for the back of the box and (2) the arms of the cross could be folded 90 from the back plane to form the cores of the adjacent four sides of the box. Optionally, the blanket could include tabs for joining the folded sides of the blanket along mating edges and tabs that could serve as hinges for the door. Vacuum bags in the form of similar five-sided boxes would be made of a suitable polymeric film, one bag to fit the outer core surface, the other to fit the inner core surface. By use of commercially available film-sealing equipment, these box-shaped bags would be seamed together to form a single vacuum bag encasing the box-shaped core. Also, a one-way valve would be sealed to the bag. Through this valve, the interior of the bag would be evacuated to a pressure between 1 and 10 torr (approximately between 0.13 and 1.3 kPa). The polymer-modified aerogel core material is known to perform well as a thermal insulator in such a partial vacuum.

Stepanian, Christopher J.↗

Aerogels for Thermal Insulation of Thermoelectric Devices

Silica aerogels have been shown to be attractive for use as thermal-insulation materials for thermoelectric devices. It is desirable to thermally insulate the legs of thermoelectric devices to suppress lateral heat leaks that degrade thermal efficiency. Aerogels offer not only high thermal- insulation effectiveness, but also a combination of other properties that are especially advantageous in thermoelectric- device applications. Aerogels are synthesized by means of sol-gel chemistry, which is ideal for casting insulation into place. As the scale of the devices to be insulated decreases, the castability from liquid solutions becomes increasingly advantageous: By virtue of castability, aerogel insulation can be made to encapsulate devices having any size from macroscopic down to nanoscopic and possibly having complex, three-dimensional shapes. Castable aerogels can permeate voids having characteristic dimensions as small as nanometers. Hence, practically all the void space surrounding the legs of thermoelectric devices could be filled with aerogel insulation, making the insulation highly effective. Because aerogels have the lowest densities of any known solid materials, they would add very little mass to the encapsulated devices. The thermal-conductivity values of aerogels are among the lowest reported for any material, even after taking account of the contributions of convection and radiation (in addition to true thermal conduction) to overall effective thermal conductivities. Even in ambient air, the contribution of convection to effective overall thermal conductivity of an aerogel is extremely low because of the highly tortuous nature of the flow paths through the porous aerogel structure. For applications that involve operating temperatures high enough to give rise to significant amounts of infrared radiation, opacifiers could be added to aerogels to reduce the radiative contributions to overall effective thermal conductivities. One example of an opacifier is carbon black, which absorbs infrared radiation. Another example of an opacifier is micron- sized metal flakes, which reflect infrared radiation. Encapsulation in cast aerogel insulation also can help prolong the operational lifetimes of thermoelectric devices that must operate in vacuum and that contain SiGe or such advanced skutterudite thermoelectric materials as CoSb3 and CeFe3.5Co0.5Sb12. The primary cause of deterioration of most thermoelectric materials is thermal decomposition or sublimation (e.g., sublimation of Sb from CoSb3) at typical high operating temperatures. Aerogel present near the surface of CoSb3 can impede the outward transport of Sb vapor by establishing a highly localized, equilibrium Sb vapor atmosphere at the surface of the CoSb3.

Sakamoto, Jeffrey↗

A Simple Transient Thermal Test Assembly for Insulation Materials

A simple transient thermal test was developed for evaluating the thermal performance of high-temperature flexible insulation materials in atmospheric pressure air. The test setup was inspired by the test assembly used for evaluating the performance of fire shelters and fire protective clothing. The heating source used was a burner supplied with propane gas that can generate relatively uniform heating over a wide area. The ratio of the in-plane width to thickness of the insulation test sample in the test assembly was selected to be greater than ten so that the heat transfer in the center of the test assembly was nearly one-dimensional. A rigid, thin Inconel plate was used as the septum plate directly exposed to the flame to provide a relatively uniform, known-temperature boundary condition for the test assembly, and to prevent convective heat transfer through the test insulation from the burner. The test sample, flexible alumina paper insulation, was placed between the Inconel plate and a thin titanium witness plate. The overall assembly was further insulated using a combination of rigid and flexible ceramic insulations to minimize heat losses from the periphery of the test assembly. Thermocouples installed on the septum and witness plates and inside the insulation test sample provided temperature measurements at various locations. For the evaluation tests, the Inconel septum plate reached temperatures between 780°C and 850°C for tests with flame exposure durations of 120 sec to 300 sec. The measured temperatures for various tests with similar flame exposure times were repeatable. A one-dimensional numerical heat transfer model of the test assembly was developed. The close agreement between measured and predicted temperatures on the titanium witness plate and inside the insulation test sample indicated that this test may provide a one-dimensional thermal testing capability for evaluation of thermal performance of similar insulations.

Daryabeigi, Kamran↗

Use of Hygrothermal Models for Understanding Water Transport in Corrosion Under Insulation Applications

Thermal insulation is used in operating facilities to conserve heat and protect against freezing amongst others. A consequence of insulating the equipment is the necessity to manage the introduced threat of corrosion under insulation (CUI). For CUI to occur, water and oxygen must enter and migrate through the insulation to reach the external surface of the equipment. The water transport characteristics are dependent on several factors such as type of insulation, type of jacketing, equipment operating temperature, external weather, water entry/leakage rate and cyclic service. In hot piping, there are competing water transport characteristics, as in water vapor moves outwards away from the equipment as water enters insulation. Knowing the water transport and the parameters that influence the time of wetness at the metal surface helps in understanding conditions favoring CUI.The use of transient hygrothermal models for moisture control is well established in the building insulation design codes and standards. The building designs naturally shed the liquid water to minimize entry and facilitate vapor management so that moisture doesn’t accumulate within building. Several building industry hygrothermal models have been developed and are available for commercial use. One such commercial model has been used to understand water transport in a CUI application. The case study involves evaluation of piping and equipment installed with a closed cell polyurethane insulation. The hygrothermal model provided insights on the parameters influencing the time of wetness and the ease of water escaping the equipment-insulation-jacketing system.

Venkateswaran, Sai P.↗

ELECTRICAL BREAKDOWN STRENGTH AND AC WITHSTAND IN HARVESTED EPR INSULATIONS FOR NUCLEAR POWER PLANTS

While the operating voltages for some instrument and control (I&C) cables can be greater than 4 kV to operate pumps, controls, and provide auxiliary power, the operating voltage for most I&C cables is near 600 V. Although the electrical stress is not nearly as high in the insulation of these cables, an ac withstand two and one-half times greater than the operating voltage after a simulated design basis exposure (DBE) has been used in environmental qualification (EQ) to determine the ability of an insulation to meet a 40-year lifetime at an operating voltage. While multiple cable lengths greater than 10 feet are needed to replicate this EQ, systematic measurement of the electrical insulation strength in harvested cable insulations can be beneficial to better understand the remaining useful life of the insulation. This understanding can only be realized through systematic comparison to some level of DBE, and electrical insulation strength measurement can provide a baseline for comparison with other mechanical, chemical, and electrical characterizations that have been utilized. Accelerated aging of two types of ethylene propylene rubber (EPR) insulations from harvested cables was carried out, and the electrical breakdown strength and indenter modulus for both insulations were determined. Results showed that degradation of electrical breakdown strength occurred in only one type of BIW insulation and that this degradation did track with that measured by indenter modulus. The methodology for using Weibull statistics for electrical breakdown strength relative to time to failure is discussed.

Duckworth, Robert↗

Excavationless Exterior Foundation Insulation Exploratory Study

Building science research supports installing exterior (soil side) foundation insulation as the optimal method to enhance the hygrothermal performance of new homes. With exterior foundation insulation, water management strategies are maximized while insulating the basement space and ensuring a more even temperature at the foundation wall. Controlling for bulk water, vapor, and wall temperature differential reduces the risk of rot and mold formation to insulation and building materials, thereby improving opportunities for structural integrity, indoor air quality, comfort, and energy efficiency. The intent of this study by the NorthernSTAR Building America Partnership team is to search for combinations of existing technologies that could enable a minimally invasive, cost-competitive, easily deployable method of upgrading soil-side foundation insulation in existing buildings. Currently, insulating foundation walls on the exterior side involves exposing the foundation wall using an excavator. Following excavation, these walls can be waterproofed, and are typically insulated with board foam in a process similar to new construction. This process is expensive and highly disruptive to the landscape and the homeowner. Also, barriers such as porches and sidewalks prevent trenching. An ideal approach would involve excavating a very narrow trench directly next to the foundation wall. Full-height foundation wall insulation might be desired, so the trenching technology should be able to dig to a depth of 7 or 8 ft. Because houses often have hardscape obstructions that are expensive to demolish and remove, the ideal technology would be capable of digging under at least some obstructions that would remain in place.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High temperature ceramic thermal insulation material

Flexible and lightweight thermal insulation materials with hierarchical microstructures are ubiquitous in thermal management and protection systems. Ceramic aerogels promise high-temperature thermal insulation but lack mechanical robustness, while the fibrous materials with excellent mechanical elasticity display modest thermal insulation. Here we describe flexible hierarchical superhydrophobic ceramic insulation nanocomposites through the densified architectured hierarchical nanostructures, radiative insulation coating, and interfacial cross-linking among composites. The lightweight flexible ceramic nanocomposites exhibit a density of 0.13 g/cm 3 , high-temperature fire resistance with thermal conductivity of 0.024 W/(m·K), and super-hydrophobicity with the water contact angle of 152°. The mechanical robustness and high-temperature thermal insulation of ceramic nanocomposites, together with its soundproof performance, shed light on the low-cost flexible insulation materials manufacturing with scalability for high-temperature thermal insulation applications under high mechanical loading conditions.

36 MATERIALS SCIENCE↗