Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Instrumentation and Detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Characterization of Si-Membrane TES Bolometer Arrays for the HIRMES Instrument

The High Resolution Mid-Infrared Spectrometer (HIRMES) instrument will fly onboard NASA's airborne Stratospheric Observatory for Infrared Astronomy (SOFIA) in 2019. HIRMES will provide astronomers with a unique observing window (25 122 µm) for exploring the evolution of protoplanetary disks into young solar systems, and the composition of our Solar System. There are two focal plane detector arrays for the instrument: a high-resolution (/ = 100,000) 8x16 detector array with a target noise-equivalent power, NEP 3x10-18 W/Hz; and a low-resolution (/ = 2,000 19,000) 16x64 detector array with a target NEP 2x10-17 W/Hz. The detectors for both of these arrays are superconducting Mo/Au bilayer transition edge sensor (TES) bolometers on thin suspended single-crystal silicon membranes. Here we present our characterization results for the detectors in both arrays, including measurements of thermal conductance with comparison to phonon transport models, saturation power, noise, and array uniformity.

Instrumentation and Photography↗

The Hitomi X-Ray Observatory, Part 2

When it was launched on 17 February 2016, the Hitomi X-ray Observatory carried four kinds of new-generation x-ray instruments—the Soft X-ray Spectrometer (SXS), the Soft X-ray Imager (SXI), the Hard X-ray Imager (HXI), and the Soft Gamma-ray Detector (SGD). All four instruments were turned on and were in the process of activation at the time of loss of contact on 26 March 2016. In the time it was operational, Hitomi was able to provide researchers with a trove of ground-breaking scientific results. Initial results demonstrated that the instruments were meeting or exceeding requirements and that Hitomi was on its way to pioneering a new era of broad-band and high-resolution x-ray spectroscopy. The results published here summarize the in-flight instrument performance, calibration, and data processing accomplishments of the observatory. Of the papers accepted for publication in this special section, 17 were presented in Part 1 in the January-March 2018 issue of JATIS (Journal of Astronomical Telescopes, Instruments, and Systems). Ten more papers are presented here as Part 2 in the April-June 2018 issue. These papers cover the detailed in-flight performance of the four state-of the-art instruments on-board the Hitomi X-Ray Observatory. These instruments were extremely diverse in their design and principles of operation, ranging from low temperature x-ray calorimeters for high-resolution spectroscopy, CCDs (Charge-Coupled Devices) for wide field imaging, high fill-factor grazing incidence x-ray optics, including multilayer x-ray optics and silicon strip and CdTe strip detectors for high-energy imaging, and a Si/CdTe Compton cameras for extending the bandpass out to 600 kiloelectronvolts. All of these instruments operated as expected and for sufficient time to validate their operating principles and carry out first light scientific investigations, published elsewhere. Collectively, these instruments, all co-aligned and operated simultaneously, provided a tool for astronomers with unprecedented resolution and broadband sensitivity for investigating high-energy processes throughout the universe. These papers serve as part of the Hitomi legacy and will guide the next generation of instruments planned for future missions.

Kelley, Richard L.↗

Global Lightning Climatology from the Tropical Rainfall Measuring Mission (TRMM), Lightning Imaging Sensor (LIS) and the Optical Transient Detector (OTD)

The Tropical Rainfall Measuring Mission (TRMM) Lightning Imaging Sensor (LIS) has been collecting observations of total lightning in the global tropics and subtropics (roughly 38 deg S - 38 deg N) since December 1997. A similar instrument, the Optical Transient Detector, operated from 1995-2000 on another low earth orbit satellite that also saw high latitudes. Lightning data from these instruments have been used to create gridded climatologies and time series of lightning flash rate. These include a 0.5 deg resolution global annual climatology, and lower resolution products describing the annual cycle and the diurnal cycle. These products are updated annually. Results from the update through 2013 will be shown at the conference. The gridded products are publicly available for download. Descriptions of how each product can be used will be discussed, including strengths, weaknesses, and caveats about the smoothing and sampling used in various products.

Cecil, Daniel J.↗

Measurement of the production cross section of pairs of isolated photons in pp collisions at 13 TeV with the ATLAS detector

A measurement of prompt photon-pair production in proton-proton collisions at $\sqrt{s}$ = 13 TeV is presented. The data were recorded by the ATLAS detector at the LHC with an integrated luminosity of 139 fb -1 . Events with two photons in the well-instrumented region of the detector are selected. The photons are required to be isolated and have a transverse momentum of p T, γ1(2) > 40 (30) GeV for the leading (sub-leading) photon. The differential cross sections as functions of several observables for the diphoton system are measured and compared with theoretical predictions from state-of-the-art Monte Carlo and fixed-order calculations. The QCD predictions from next-to-next-to-leading-order calculations and multi-leg merged calculations are able to describe the measured integrated and differential cross sections within uncertainties, whereas lower-order calculations show significant deviations, demonstrating that higher-order perturbative QCD corrections are crucial for this process. The resummed predictions with parton showers additionally provide an excellent description of the low transverse-momentum regime of the diphoton system.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

areaDetector/ADTimePix3

ADTimePix3 is an open‑source EPICS areaDetector driver for TimePix3 pixel detectors from Advanced Scientific Instruments (ASI). It provides a complete control and data‑acquisition interface between EPICS and the Serval server, supporting both real detectors (single‑chip and 2×2 quad configurations) and the TimePix3 emulator. The driver configures measurements via an HTTP/JSON REST API and acquires data through high‑rate TCP streams for raw events, images, and histograms. It offers real‑time preview and accumulated images, Time‑of‑Flight histogram processing, pixel masking (including Binary Pixel Configuration files and hot‑pixel tools), extensive health and status monitoring, and integration with standard areaDetector plugins for file saving and downstream analysis. ADTimePix3 is designed for Linux 64‑bit systems (tested on Ubuntu and RHEL) and is distributed under an MIT license with additional institutional disclaimers, enabling reuse and extension in photon science beamlines and other TimePix3‑based experimental facilities.

Gofron, Kaz↗

Preliminary On-Orbit Neutron Dose Equivalent and Energy Spectrum Results from the ISS-RAD Fast Neutron Detector (FND)

The ISS-RAD instrument was activated on ISS on February 1st, 2016. Integrated in ISS-RAD, the Fast Neutron Detector (FND) performs, for the first time on ISS, routine and precise direct neutron measurements between 0.5 and 8 MeV. Preliminary results for neutron dose equivalent and neutron flux energy distributions from online/on-board algorithms and offline ground analyses will be shown, along with comparisons to simulated data and previously measured neutron spectral data. On-orbit data quality and pre-launch analysis validation results will be discussed as well.

Semones, Edward↗

A balloon-borne instrument for high-resolution astrophysical spectroscopy in the 20-8000 keV energy range

The Low Energy Gamma ray Spectrometer (LEGS) is designed to perform fine energy resolution measurements of astrophysical sources. The instrument is configured for a particular balloon flight with either of two sets of high purity germanium detectors. In one configuration, the instrument uses an array of three coaxial detectors (effective volume equal to or approximately 230 cubic cm) inside an NaI (T1) shield and collimator (field of view equal to or approximately 16 deg FWHM) and operates in the 80 to 8000 keV energy range. In the other configuration, three planar detectors (effective area equal to or approximately square cm) surrounded by a combination of passive Fe and active NaI for shielding and collimation (field of view equal to or approximately 5 deg x 10 deg FWHM) are optimized for the 20 to 200 keV energy range. In a typical one day balloon flight, LEGS sensitivity limit (3 sigma) for narrow line features is less than or approximately .0008 ph/cm/s square (coaxial array: 80 to 2000 keV) and less than or approximately .0003 ph/square cm/s (planar array: 50 to 150 keV).

Paciesas, W. S.↗

Machine learning for imaging Cherenkov detectors

Imaging Cherenkov detectors are largely used in modern nuclear and particle physics experiments where cutting-edge solutions are needed to face always more growing computing demands. This is a fertile ground for AI-based approaches and at present we are witnessing the onset of new highly efficient and fast applications. This paper presents novel directions with applications to Cherenkov detectors. In particular, recent advances on detector design and calibration, as well as particle identification are presented.

47 OTHER INSTRUMENTATION↗

Signal Conditioning for Satellite Borne Energetic-Charged-Particle Experiments

Many of the spacecraft launched thus far have carried detectors for investigating cosmic rays, solar protons, solar plasmas, and the geomagnetically trapped radiation. These detectors, which will find continued application in the future, include ion chambers; proportional, Geiger-Muller, scintillation, Cerenkov, and solid state detectors; ion collectors; and nuclear emulsions. The instrumentation required to condition the signals from these detectors prior to telemetering is steadily growing more complex in order to permit more meaningful measurements. This report describes a number of instrumentation elements typical of the present state of the art, and a present-generation three-detector system which illustrates the integration of such basic elements into a complex system.

Ludwig, George H.↗

The Vector Electric Field Instrument on the C/NOFS Satellite

We provide an overview of the Vector Electric Field Instrument (VEFI) on the Air Force Communication/Navigation Outage Forecasting System (C/NOFS) satellite, a mission designed to understand, model, and forecast the presence of equatorial ionospheric irregularities. VEFI is a NASA GSFC instrument designed 1) to investigate the role of the ambient electric fields in initiating nighttime ionospheric density depletions and turbulence; 2) to determine the electric fields associated with abrupt, large amplitude, density depletions and 3) to quantify the spectrum of the wave electric fields and plasma densities (irregularities) associated with density depletions or Equatorial Spread-F. The VEFI instrument includes a vector electric field double probe detector, a Langmuir trigger probe, a flux gate magnetometer, a lightning detector and associated electronics. The heart of the instrument is the set of double probe detectors designed to measure DC and AC electric fields using 6 identical, mutually orthogonal, deployable 9.5 m booms tipped with 10 cm diameter spheres containing embedded preamplifiers. A description of the instrument and its sensors will be presented. If available, representative measurements will be provided.

Pfaff, R.↗

Single detector laser-induced fluorescence imager and raman spectral instrument

Apparatus include divergence optics removably coupled to receive a probe beam in a first imaging mode to cause the probe beam to diverge before impinging on a first area of a target surface, and to not receive the probe beam in a second imaging mode to cause the probe beam to impinge on a second area of the target surface smaller than the first area, collection optics configured to receive, in response to the probe beam, luminescence light emitted from the first area and spectral light emitted from the second area, and an optical detector coupled to the collection optics, wherein the optical detector includes a luminescence imaging detector portion and a spectral imaging detector portion adjacent to the luminescence imaging detector portion, wherein the luminescence imaging detector portion is configured to receive the luminescence light emitted from the first area and the spectral imaging detector portion is configured to receive the spectral light from the second area.

Gasda, Patrick J.↗

Mitigation of the Brighter-fatter Effect in the LSST Camera

Abstract Thick, fully depleted charge-coupled devices are known to exhibit nonlinear behavior at high signal levels due to the dynamic behavior of charges collecting in the potential wells of pixels, called the brighter-fatter effect (BFE). The effect results in distorted images of bright calibration stars, creating a flux-dependent point-spread function that if left unmitigated, could make up a large fraction of the error budget in Stage IV weak-lensing (WL) surveys such as the Legacy Survey of Space and Time (LSST). In this paper, we analyze image measurements of flat fields and artificial stars taken at different illumination levels with the LSST Camera (LSSTCam) at SLAC National Accelerator Laboratory in order to quantify this effect in the LSSTCam before and after a previously introduced correction technique. We observe that the BFE evolves anisotropically as a function of flux due to higher-order BFEs, which violates the fundamental assumption of this correction method. We then introduce a new method based on a physically motivated model to account for these higher-order terms in the correction, and then we test the modified correction on both data sets. We find that the new method corrects the effect in flat fields better than it corrects the effect in artificial stars, which we suggest is the result of sub-pixel physics not included in this correction model. We use these results to define a new metric for the full-well capacity of our sensors and advise image processing strategies to further limit the impact of the effect on LSST WL science pathways.

47 OTHER INSTRUMENTATION↗

Large Format Arrays for Far Infrared and Millimeter Astronomy

Some of the most compelling questions in modem astronomy are best addressed with submillimeter and millimeter observations. The question of the role of inflation in the early evolution of the universe is best addressed with large sensitive arrays of millimeter polarimeters. The study of the first generations of galaxies requires sensitive submillimeter imaging, which can help us to understand the history of energy release and nucleosynthesis in the universe. Our ability to address these questions is dramatically increasing, driven by dramatic steps in the sensitivity and size of available detector arrays. While the MIPS instrument on the SIRTF mission will revolutionize far infrared astronomy with its 1024 element array of photoconductors, thermal detectors remain the dominant technology for submillimeter and millimeter imaging and polarimetry. The last decade has seen the deployment of increasingly large arrays of bolometers, ranging from the 48 element arrays deployed on the KAO in the late 198Os, to the SHARC and SCUBA arrays in the 1990s. The past years have seen the deployment of a new generation of larger detector arrays in SHARC II (384 channels) and Bolocam (144 channels). These detectors are in operation and are beginning to make significant impacts on the field. Arrays of sensitive submillimeter bolometers on the SPIRE instrument on Herschel will allow the first large areas surveys of the sky, providing important insight into the evolution of galaxies. The next generation of detectors, led by SCUBA II, will increase the focal scale of these instruments by an order of magnitude. Two major missions are being planned by NASA for which further development of long wavelength detectors is essential, The SAFlR mission, a 10-m class telescope with large arrays of background limited detectors, will extend our reach into the epoch of initial galaxy formation. A major goal of modem cosmology is to test the inflationary paradigm in the early evolution of the universe. To this end, a mission is planned to detect the imprint of inflation on the CMB by precision measurement of its polarization. This work requires very large arrays of sensitive detectors which can provide unprecedented control of a wide range of systematic errors, given the small amplitude of the signal of interest. We will describe the current state of large format detector arrays, the performance requirements set by the new missions, and the different approaches being developed in the community to meet these requirements. We are confident that within a decade, these developments will lead to dramatic advances in our understanding of the evolution of the universe.

Moseley, Harvey↗

Excalibur: A Nonparametric, Hierarchical Wavelength Calibration Method for a Precision Spectrograph

Excalibur is a nonparametric, hierarchical framework for precision wavelength calibration of spectrographs. It is designed with the needs of extreme-precision radial-velocity (EPRV) instruments in mind, which require calibration or stabilization to better than 10{sup −4} pixels. Instruments vary along only a few dominant degrees of freedom, especially EPRV instruments that feature highly stabilized optical systems and detectors. Excalibur takes advantage of this property by using all calibration data to construct a low-dimensional representation of all accessible calibration states for an instrument. Excalibur also takes advantage of laser-frequency combs or etalons, which generate a dense set of stable calibration points. This density permits the use of a nonparametric wavelength solution that can adapt to any instrument or detector oddities better than parametric models, such as a polynomial. We demonstrate the success of this method with data from the Extreme Precision Spectrograph (EXPRES), which uses a laser-frequency comb. When wavelengths are assigned to laser comb lines using excalibur, the rms of the residuals is about one-fifth that of wavelengths assigned using polynomial fits to individual exposures. Radial-velocity measurements of HD 34411 show a reduction in rms scatter over a 10 month time baseline from 1.17 to 1.05 m s{sup −1}.

47 OTHER INSTRUMENTATION↗

Laboratory evaluation of an airborne ozone instrument that compensates for altitude/sensitivity effects

One problem encountered in the use of air-quality instrumentation on aircraft is the variation of instrument sensitivity with pressure as the result of altitude changes of the aircraft. Many instruments experience sensitivity changes of as much as a factor of 2 at altitudes of 6 km. Discussed are recent modifications to a chemiluminescent (ethylene) ozone detector that allow the instrument to automatically compensate for pressure/sensitivity effects. The modification provides automated mass flow rate control for both the sample and ethylene gas flows. The flow control systems maintain flow rate to within 15 percent for a 100-torr instantaneous pressure change, and flow rates are returned to the desired set points within 10 s after the pressure change. During simulated altitude changes (300 m/min from mean sea level to 3-km altitude), flow rates were controlled to within 3 percent of the set point. Laboratory data are summarized verifying the operation of the instrument for a pressure range of 760 torr (sea level) to 350 torr (approximately 20,000 ft) and an ozone concentration range from 20 to approximately 700 ppb.

Gregory, G. L.↗

Parameter Estimation for Compact Binary Coalescence Signals with the First Generation Gravitational-Wave Detector Network

Compact binary systems with neutron stars or black holes are one of the most promising sources for ground-based gravitational-wave detectors. Gravitational radiation encodes rich information about source physics; thus parameter estimation and model selection are crucial analysis steps for any detection candidate events. Detailed models of the anticipated waveforms enable inference on several parameters, such as component masses, spins, sky location and distance, that are essential for new astrophysical studies of these sources. However, accurate measurements of these parameters and discrimination of models describing the underlying physics are complicated by artifacts in the data, uncertainties in the waveform models and in the calibration of the detectors. Here we report such measurements on a selection of simulated signals added either in hardware or software to the data collected by the two LIGO instruments and the Virgo detector during their most recent joint science run, including a blind injection where the signal was not initially revealed to the collaboration. We exemplify the ability to extract information about the source physics on signals that cover the neutron-star and black-hole binary parameter space over the component mass range 1M25M and the full range of spin parameters. The cases reported in this study provide a snapshot of the status of parameter estimation in preparation for the operation of advanced detectors.

Aasi, J.↗

Characterisation of signal-induced noise in Hamamatsu R11265 Multianode Photomultiplier Tubes

Signal-induced noise is observed in Hamamatsu R11265 Multianode Photomultiplier Tubes, manifesting up to several microseconds after the single photoelectron response signal and localised in specific anodes. The mean number of noise pulses varies between devices, and shows significant dependence on the applied high-voltage. The characterisation of this noise and the mitigation strategies to perform optimal single-photon counting at 40 MHz, as required by the LHCb Ring-Imaging Cherenkov detectors, are reported.

47 OTHER INSTRUMENTATION↗