Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INTEGRAL DOSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

SU-E-T-107: Development of a GPU-Based Dose Delivery System for Adaptive Pencil Beam Scanning

Purpose: A description of a GPU-based dose delivery system (G-DDS) to integrate a fast forward planning implementing in real-time the prescribed sequence of pencil beams. The system, which is under development, is designed to evaluate the dose distribution deviations due to range variations and interplay effects affecting mobile tumors treatments. Methods: The Dose Delivery System (DDS) in use at the Italian Centro Nazionale di Adroterapia Oncologica (CNAO), is the starting point for the presented system. A fast and partial forward planning (FP) tool has been developed to evaluate in few seconds the delivered dose distributions using the DDS data (on-line measurements of spot properties, i.e. number of particles and positions). The computation is performed during the intervals between synchrotron spills and, made available at the end of each spill. In the interval between two spills, the G-DDS will evaluate the delivered dose distributions taking into account the real-time target positions measured by a tracking system. The sequence of prescribed pencil beams for the following spill will be adapted taking into account the variations with respect to the original plan due to the target motion. In order to speed up the computation required to modify pencil beams distribution (up to 400 times has been reached), the Graphics Processing Units (GPUs) and advanced Field Programmable Gate Arrays (FPGAs) are used. Results: An existing offline forward planning is going to be optimized for the CUDA architecture: the gain in time will be presented. The preliminary performances of the developed GPU-based FP algorithms will be shown. Conclusion: A prototype of a GPU-based dose delivery system is under development and will be presented. The system workflow will be illustrated together with the approach adopted to integrate the three main systems, i.e. CNAO dose delivery system, fast forward planning, and tumor tracking system.

60 APPLIED LIFE SCIENCES↗

Intensity Modulated Radiation Therapy With Simultaneous Integrated Boost in Patients With Brain Oligometastases: A Phase 1 Study (ISIDE-BM-1)

Purpose: To investigate the maximum tolerated dose of intensity modulated radiation therapy simultaneous integrated boost whole-brain radiation therapy for palliative treatment of patients with <5 brain metastases using a standard linear accelerator. Materials and Methods: The whole brain plus 3-mm margin was defined as the planning target volume (PTV{sub wb}), whereas each brain metastasis, defined as the contrast-enhancing tumor on MRI T1 scans, plus a 3-mm isotropic margin, was defined as metastases PTV (PTV{sub m}). Radiation therapy was delivered in 10 daily fractions (2 weeks). Only the dose to PTV{sub m} was progressively increased in the patient cohorts (35 Gy, 40 Gy, 45 Gy, 50 Gy), whereas the PTV{sub wb} was always treated with 30 Gy (3 Gy per fraction) in all patients. The dose-limiting toxicity was evaluated providing that 3 months of follow-up had occurred after the treatment of a 6-patient cohort. Results: Thirty patients were enrolled in the study (dose PTV{sub m}: 35 Gy, 8 patients; 40 Gy, 6 patients; 45 Gy, 6 patients; 50 Gy, 10 patients). The number of treated brain metastases was 1 in 18 patients, 2 in 5 patients, 3 in 6 patients, and 4 in 1 patient. Three patients experienced dose-limiting toxicity: 1 patient at dose level 2 presented grade 3 (G3) skin toxicity; 1 patient at dose level 4 presented G3 neurologic toxicity; and 1 patient at the same level showed brain hemorrhage. Most patients showed G1 to 2 acute toxicity, in most cases skin (n=19) or neurologic (n=10). Twenty-seven were evaluable for response: 6 (22%) stable disease, 18 (67%) partial response, and 3 (11%) complete response. Median survival and 1-year overall survival were 12 months and 53%, respectively. No patient showed late toxicity. Conclusions: In this first prospective trial on the use of intensity modulated radiation therapy simultaneous integrated boost delivered with a standard linear accelerator in patients with brain oligometastases, a boost dose up to 50 Gy in 10 fractions was tolerable according to the study design.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric evaluation of integrated IMRT treatment of the chest wall and supraclavicular region for breast cancer after modified radical mastectomy

To investigate the dosimetric characteristics of irradiation of the chest wall and supraclavicular region as an integrated volume with intensity-modulated radiation therapy (IMRT) after modified radical mastectomy. This study included 246 patients who received modified radical mastectomy. The patients were scanned with computed tomography, and the chest wall (with or without the internal mammary lymph nodes) and supraclavicular region were delineated. For 143 patients, the chest wall and supraclavicular region were combined as an integrated planning volume and treated with IMRT. For 103 patients, conventional treatments were employed with 2 tangential fields for the chest wall, abutting a mixed field of 6-MV x-rays (16 Gy) and 9-MeV electrons (34 Gy) for the upper supraclavicular region. The common prescription dose was 50 Gy/25 Fx/5 W to 90% of the target volume. The dosimetric characteristics of the chest wall, the supraclavicular region, and normal organs were compared. For the chest wall target, compared with conventional treatments, the integrated IMRT plans lowered the maximum dose, increased the minimum dose, and resulted in better conformity and uniformity of the target volume. There was an increase in minimum, average, and 95% prescription dose for the integrated IMRT plans in the supraclavicular region, and conformity and uniformity were improved. The V{sub 30} of the ipsilateral lung and V{sub 10}, V{sub 30}, and mean dose of the heart on the integrated IMRT plans were lower than those of the conventional plans. The V{sub 5} and V{sub 10} of the ipsilateral lung and V{sub 5} of the heart were higher on the integrated IMRT plans (p < 0.05) than on conventional plans. Without an increase in the radiation dose to organs at risk, the integrated IMRT treatment plans improved the dose distribution of the supraclavicular region and showed better dose conformity and uniformity of the integrated target volume of the chest wall and supraclavicular region.

61 RADIATION PROTECTION AND DOSIMETRY↗

WE-DE-201-06: Impact of Temporal Image Coregistration Methods On 3D Internal Dose Calculations in Targeted Radionuclide Therapy

Purpose: The calculation of 3D internal dose calculations in targeted radionuclide therapy requires the acquisition and temporal coregistration of a serial PET/CT or SPECT/CT images. This work investigates the dosimetric impact of different temporal coregistration methods commonly used for 3D internal dosimetry. Methods: PET/CT images of four mice were acquired at 1, 24, 48, 72, 96, 144 hrs post-injection of {sup 124}I-CLR1404. The therapeutic {sup 131}I-CLR1404 absorbed dose rate (ADR) was calculated at each time point using a Geant4-based MC dosimetry platform using three temporal image coregistration Methods: (1) no coregistration (NC), whole body sequential CT-CT affine coregistration (WBAC), and individual sequential ROI-ROI affine coregistration (IRAC). For NC, only the ROI mean ADR was integrated to obtain ROI mean doses. For WBAC, the CT at each time point was coregistered to a single reference CT. The CT transformations were applied to the corresponding ADR images and the dose was calculated on a voxel-basis within the whole CT volume. For IRAC, each individual ROI was isolated and sequentially coregistered to a single reference ROI. The ROI transformations were applied to the corresponding ADR images and the dose was calculated on a voxel-basis within the ROI volumes. Results: The percent differences in the ROI mean doses were as large as 109%, 88%, and 32%, comparing the WBAC vs. IRAC, NC vs. IRAC, and NC vs. WBAC methods, respectively. The CoV in the mean dose between the all three methods ranged from 2–36%. The pronounced curvature of the spinal cord was not adequately coregistered using WBAC which resulted in large difference between the WBAC and IRAC. Conclusion: The method used for temporal image coregistration can result in large differences in 3D internal dosimetry calculations. Care must be taken to choose the most appropriate method depending on the imaging conditions, clinical site, and specific application. This work is partially funded by NIH Grant R21 CA198392-01.

60 APPLIED LIFE SCIENCES↗

Total-dose radiation effects data for semiconductor devices, volume 2

Total ionizing dose radiation test data on integrated circuits are analyzed. Tests were performed with the electron accelerator (Dynamitron) that provides a steady state 2.5 MeV electron beam. Some radiation exposures were made with a Cobalt-60 gamma ray source. The results obtained with the Cobalt-60 source are considered an approximate measure of the radiation damage that would be incurred by an equivalent dose of electrons.

Price, W. E.↗

Undulator Radiation Damage Experience at LCLS

The SLAC National Accelerator Laboratory has been running the Linac Coherent Light Source (LCLS), the first x-ray Free Electron Laser since 2009. Undulator magnet damage from radiation, produced by the electron beam traveling through the 133-m long straight vacuum tube, has been and is a concern. A damage measurement experiment has been performed in 2007 in order to obtain dose versus damage calibrations. Radiation reduction and detection devices have been integrated into the LCLS undulator system. The accumulated radiation dose rate was continuously monitored and recorded. In addition, undulator segments have been routinely removed from the beamline to be checked for magnetic (50 ppm, rms) and mechanic (about 0.25 µm, rms) changes. A reduction in strength of the undulator segments is being observed, at a level, which is now clearly above the noise. Recently, potential sources for the observed integrated radiation levels have been investigated. The paper discusses the results of these investigation as well as comparison between observed damage and measured dose accumulations and discusses, briefly, strategies for the new LCLS-II upgrade, which will be operating at more than 300 times larger beam rate.

43 PARTICLE ACCELERATORS↗

Real-time fast inverse dose optimization for image guided adaptive radiation therapy-Enhancements to fast inverse dose optimization (FIDO)

A fast, accurate and stable optimization algorithm is very important for inverse planning of intensity-modulated radiation therapy (IMRT), and for implementing dose-adaptive radiotherapy in the future. Conventional numerical search algorithms with positive beam weight constraints generally require numerous iterations and may produce suboptimal dose results due to trapping in local minima regions of the objective function landscape. A direct solution of the inverse problem using conventional quadratic objective functions without positive beam constraints is more efficient but it will result in unrealistic negative beam weights. We review here a direct solution of the inverse problem that is efficient and does not yield unphysical negative beam weights. In fast inverse dose optimization (FIDO) method the objective function for the optimization of a large number of beamlets is reformulated such that the optimization problem is reducible to a linear set of equations. The optimal set of intensities is then found through a matrix inversion, and negative beamlet intensities are avoided without the need for externally imposed ad hoc conditions. In its original version [S. P. Goldman, J. Z. Chen, and J. J. Battista, in Proceedings of the XIVth International Conference on the Use of Computers in Radiation Therapy, 2004, pp. 112-115; S. P. Goldman, J. Z. Chen, and J. J. Battista, Med. Phys. 32, 3007 (2005)], FIDO was tested on single two-dimensional computed tomography (CT) slices with sharp KERMA beams without scatter, in order to establish a proof of concept which demonstrated that FIDO could be a viable method for the optimization of cancer treatment plans. In this paper we introduce the latest advancements in FIDO that now include not only its application to three-dimensional volumes irradiated by beams with full scatter but include as well a complete implementation of clinical dose-volume constraints including maximum and minimum dose as well as equivalent uniform dose constraints. The method has been integrated into a commercial treatment planning system (Pinnacle, Philips Medical Systems) for beta testing using clinical radiotherapy cases and standard dose constraints set by radiation oncologists. Our FIDO method consistently delivered excellent treatment plans comparable and often better than those obtained using standard optimization techniques that are considerably slower. By design, FIDO is guaranteed to find a global minimum and will achieve highly conformal and homogeneous dose distributions without the need for artificial internal contours that must be created in conventional IMRT optimization systems to help the search engines better control some beam entry directions and in this way avoid the creation of hot and cold spots. This method provides a fast, intuitive and robust technique that yields excellent results for the inverse planning of IMRT. FIDO's ability to efficiently optimize very large numbers of beamlet weights also makes it an ideal tool for the optimization of helical tomotherapy. Future gains in speed will make it possible to use FIDO for instant treatment plan reoptimization using CT images produced at the radiotherapy machine, just prior to daily treatments of the patient.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-150: End to End Tests On the First Clinical EDGETM

Purpose: To quantify the sub millimeter overall accuracy of EDGETM, the dedicated linac based SRS/SABR treatment platform from Varian, using a novel End-to-End (E2E) test phantom. Methods: The new E2E test phantom developed by Varian consists of a cube with an outer dimension of 15x15x15 cm3. The phantom is equipped with an exchangable inner cube (7×7×7 cm3) to hold radiochromic films or a tungsten ball (diameter = 5 mm) for Winston-Lutz tests. 16 ceramic balls (diameter = 5 mm) are embedded in the outer cube. Three embedded Calypso transponders allow for Calypso based monitoring. The outer surface of the phantom is tracked using the Optical Surface Monitoring System (OSMS). The phantom is positioned using kV, MV and CBCT images. A simCT of the phantom was acquired and SRS/SABR plans were treated using the new phantom on the first clinical installed EDGETM. As a first step a series of EPID based Winston-Lutz tests have been performed. As a second step the calculated dose distribution applied to the phantom was verified with radiochromic films in orthogonal planes. The measured dose distribution is compared with the calculated (Eclipse) one based on the known isocenter on both dose distributions. The geometrical shift needed to match both dose distributions is the overall accuracy and is determined using dose profiles, isodose lines or gamma pass rates (3%, 1 mm). Results: Winston-Lutz tests using the central tungsten BB demonstrated a targeting accuracy of 0.44±0.18mm for jaw (2cm × 2cm) defined 0.39±0.19mm for MLC (2cm × 2cm) defined and 0.37±0.15mm for cone (12.5 mm) defined fields. A treated patient plan (spinal metastases lesion with integrated boost) showed a dosimetric dose localization accuracy of 0.6mm. Conclusion: Geometric and dosimetric E2E tests on EDGETM, show sub-millimeter E2E targeting and dose localisation accuracy.

60 APPLIED LIFE SCIENCES↗

SU-C-202-04: Adapting Biologically Optimized Dose Escalation Based On Mid-Treatment PET/CT for Non-Small-Cell Lung Cancer

Purpose: To develop a biological modeling strategy which incorporates the response observed on the mid-treatment PET/CT into a dose escalation design for adaptive radiotherapy of non-small-cell lung cancer. Method: FDG-PET/CT was acquired midway through standard fractionated treatment and registered to pre-treatment planning PET/CT to evaluate radiation response of lung cancer. Each mid-treatment PET voxel was assigned the median SUV inside a concentric 1cm-diameter sphere to account for registration and imaging uncertainties. For each voxel, the planned radiation dose, pre- and mid-treatment SUVs were used to parameterize the linear-quadratic model, which was then utilized to predict the SUV distribution after the full prescribed dose. Voxels with predicted post-treatment SUV≥2 were identified as the resistant target (response arm). An adaptive simultaneous integrated boost was designed to escalate dose to the resistant target as high as possible, while keeping prescription dose to the original target and lung toxicity intact. In contrast, an adaptive target volume was delineated based only on the intensity of mid-treatment PET/CT (intensity arm), and a similar adaptive boost plan was optimized. The dose escalation capability of the two approaches was compared. Result: Images of three patients were used in this planning study. For one patient, SUV prediction indicated complete response and no necessary dose escalation. For the other two, resistant targets defined in the response arm were multifocal, and on average accounted for 25% of the pre-treatment target, compared to 67% in the intensity arm. The smaller response arm targets led to a 6Gy higher mean target dose in the adaptive escalation design. Conclusion: This pilot study suggests that adaptive dose escalation to a biologically resistant target predicted from a pre- and mid-treatment PET/CT may be more effective than escalation based on the mid-treatment PET/CT alone. More plans and ultimately clinical protocols are needed to validate this approach. MSKCC has a research agreement with Varian Medical System.

60 APPLIED LIFE SCIENCES↗

Technical Note: SCUDA: A software platform for cumulative dose assessment

Purpose: Accurate tracking of anatomical changes and computation of actually delivered dose to the patient are critical for successful adaptive radiation therapy (ART). Additionally, efficient data management and fast processing are practically important for the adoption in clinic as ART involves a large amount of image and treatment data. The purpose of this study was to develop an accurate and efficient Software platform for CUmulative Dose Assessment (SCUDA) that can be seamlessly integrated into the clinical workflow. Methods: SCUDA consists of deformable image registration (DIR), segmentation, dose computation modules, and a graphical user interface. It is connected to our image PACS and radiotherapy informatics databases from which it automatically queries/retrieves patient images, radiotherapy plan, beam data, and daily treatment information, thus providing an efficient and unified workflow. For accurate registration of the planning CT and daily CBCTs, the authors iteratively correct CBCT intensities by matching local intensity histograms during the DIR process. Contours of the target tumor and critical structures are then propagated from the planning CT to daily CBCTs using the computed deformations. The actual delivered daily dose is computed using the registered CT and patient setup information by a superposition/convolution algorithm, and accumulated using the computed deformation fields. Both DIR and dose computation modules are accelerated by a graphics processing unit. Results: The cumulative dose computation process has been validated on 30 head and neck (HN) cancer cases, showing 3.5 ± 5.0 Gy (mean±STD) absolute mean dose differences between the planned and the actually delivered doses in the parotid glands. On average, DIR, dose computation, and segmentation take 20 s/fraction and 17 min for a 35-fraction treatment including additional computation for dose accumulation. Conclusions: The authors developed a unified software platform that provides accurate and efficient monitoring of anatomical changes and computation of actually delivered dose to the patient, thus realizing an efficient cumulative dose computation workflow. Evaluation on HN cases demonstrated the utility of our platform for monitoring the treatment quality and detecting significant dosimetric variations that are keys to successful ART.

60 APPLIED LIFE SCIENCES↗

Analysis of gamma-ray dosimetry experiments in the zero power MINERVE facility

The objective of this study is to develop nuclear heating measurement methods in zero power experimental reactors. These developments contribute to the qualification of photonics calculation schemes for the assessment of gamma heating in the future Jules Horowitz Material Testing Reactor. This paper presents the analysis of thermoluminescent detector (TLD) experiments in the UO{sub 2} core of the MINERVE Research Reactor at the French Alternative Energies and Atomic Energy Commission center in Cadarache. The experimental sources of uncertainty in the gamma dose have been reduced by improving the measurement conditions and the repeatability of the calibration step for each individual TLD. The interpretation of these measurements needs to take into account the calculation of cavity correction factors related to calibration and irradiation configurations, as well as neutron correction calculations. These calculations are based on Monte Carlo simulations of neutron-gamma and gamma-electron transport coupled particles. The comparison between calculated and measured integral gamma-ray absorbed doses in the aluminum material surrounding the TLD shows that calculations slightly overestimate the measurement, with a calculated versus experimental ratio equal to 1.04 {+-} 5.7 % (k=2). (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Analysis and recent advances in gamma heating measurements in MINERVE facility by using TLD and OSLD techniques

The objective of this study is to develop nuclear heating measurement methods in Zero Power experimental reactors. This paper presents the analysis of Thermo-Luminescent Detector (TLD) and Optically Stimulated Luminescent Detectors (OSLD) experiments in the UO{sub 2} core of the MINERVE research reactor at the CEA Cadarache. The experimental sources of uncertainties on the gamma dose have been reduced by improving the conditions, as well as the repeatability, of the calibration step for each individual TLD. The interpretation of these measurements needs to take into account calculation of cavity correction factors, related to calibration and irradiation configurations, as well as neutron corrections calculations. These calculations are based on Monte Carlo simulations of neutron-gamma and gamma-electron transport coupled particles. TLD and OSLD are positioned inside aluminum pillboxes. The comparison between calculated and measured integral gamma-ray absorbed doses using TLD, shows that calculation slightly overestimates the measurement with a C/E value equal to 1.05 {+-} 5.3 % (k = 2). By using OSLD, the calculation slightly underestimates the measurement with a C/E value equal to 0.96 {+-} 7.0% (k = 2. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Radiation Tolerant Electronics and Digital Processing for the Phase-I Trigger Readout Upgrade of the ATLAS Liquid Argon Calorimeters

The high luminosities of L > 10{sup 34} cm{sup -2}s{sup -1} at the Large Hadron Collider (LHC) at CERN produce an intense radiation environment that the detectors and their electronics must withstand. The ATLAS detector is a multi-purpose apparatus constructed to explore the new particle physics regime opened by the LHC. Of the many decay particles observed by the ATLAS detector, the energy of the created electrons and photons is measured by a sampling calorimeter technique that uses Liquid Argon (LAr) as its active medium. The front end (FE) electronic readout of the ATLAS LAr calorimeter located on the detector itself consists of a combined analog and digital processing system. In order to exploit the higher luminosity while keeping the same trigger bandwidth of 100 kHz, higher transverse granularity, higher resolution and longitudinal shower shape information will be provided from the LAr calorimeter to the Level-l trigger processors. New trigger readout electronics have been designed for this purpose, which will withstand the radiation dose levels expected for an integrated luminosity of 3000 fb{sup -1} during the high luminosity LHC (HL-LHC), which is well above the original LHC design qualifications. (authors)

43 PARTICLE ACCELERATORS↗

Dosimetric properties of an amorphous-silicon EPID used in continuous acquisition mode for application to dynamic and arc IMRT

Dosimetric properties of an amorphous-silicon electronic portal imaging device (EPID) operated in a real-time acquisition mode were investigated. This mode will be essential for time-resolved dose verification of dynamic (sliding window) intensity modulated radiation therapy (IMRT) and intensity modulated arc radiation therapy (arc-IMRT). The EPID was used in continuous acquisition mode (i.e., ''cine'' mode) where individual sequential image frames are acquired in real time. The properties studied include dose linearity, reproducibility of response, and image stability. Results of using the continuous acquisition mode with several example treatments including dynamic IMRT, arc treatment, and single-arc-IMRT are compared to results using the well-studied integrated acquisition mode (i.e., ''frame averaging'' or ''IMRT'' mode). Real-time EPID response was also compared to real-time ion-chamber data for selected points in the deliveries. The example treatment deliveries in both continuous and integrated acquisition modes were converted to arbitrary EPID dose units via a calibration field. The summation of all acquired continuous mode images was compared using percentage dose difference to the single image acquired in the integrated mode using in-field pixels only (defined as those pixels >10% of maximum, in-field signal). Using the continuous acquisition mode, the EPID response was not linear with dose. It was found that the continuous mode dose response corresponded approximately to dropping one image per acquisition session. Reproducibility of EPID response to low monitor units (MUs) was found to be poor but greatly improved with increasing MU. Open field profiles were found to be stable in the cross-plane direction but required several frames to become stable in the in-plane direction. However, both of these issues are clinically insignificant due to arc-IMRT deliveries requiring relatively large monitor units (>100 MU). Analysis of the five IMRT, arc, and arc-IMRT tests revealed that all examples compared to within 2% of maximum dose for more than 95% of in-field pixels. The continuous acquisition mode is suited to time-resolved dosimetry applications including arc-IMRT and dynamic IMRT, giving comparable dose results to the well-studied integrated acquisition mode, although caution should be used in low MU applications. Time-resolved EPID dose information also compared well to time-resolved ion-chamber measurements.

61 RADIATION PROTECTION AND DOSIMETRY↗

Pelvic Radiotherapy for Cancer of the Cervix: Is What You Plan Actually What You Deliver?

Purpose: Whole pelvic intensity-modulated radiotherapy (IMRT) is increasingly being used to treat cervix cancer and other gynecologic tumors. However, tumor and normal organ movement during treatment can substantially detract from the benefits of this approach. This study explored the effect of internal anatomic changes on the dose delivered to the tumor and organs at risk using a strategy integrating deformable soft-tissue modeling with simulated dose accumulation. Methods and Materials: Twenty patients with cervix cancer underwent baseline and weekly pelvic magnetic resonance imaging during treatment. Interfraction organ motion and delivered (accumulated) dose was modeled for three treatment scenarios: four-field box, large-margin whole pelvic IMRT (20-mm planning target volume, but 10 mm inferiorly) and small-margin IMRT (5-mm planning target volume). Results: Individually, the planned dose was not the same as the simulated delivered dose; however, when taken as a group, this was not statistically significant for the four-field box and large-margin IMRT plans. The small-margin IMRT plans yielded adequate target coverage in most patients; however, significant target underdosing occurred in 1 patient who displayed excessive, unpredictable internal target movement. The delivered doses to the organs at risk were significantly reduced with the small-margin plan, although substantial variability was present among the patients. Conclusion: Simulated dose accumulation might provide a more accurate depiction of the target and organ at risk coverage during fractionated whole pelvic IMRT for cervical cancer. The adequacy of primary tumor coverage using 5-mm planning target volume margins is contingent on the use of daily image-guided setup.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Vaginal Dose Is Associated With Toxicity in Image Guided Tandem Ring or Ovoid-Based Brachytherapy

Purpose: To calculate vaginal doses during image guided brachytherapy with volume-based metrics and correlate with long-term vaginal toxicity. Methods and Materials: In this institutional review board–approved study, institutional databases were searched to identify women undergoing computed tomography and/or magnetic resonance–guided brachytherapy at the Duke Cancer Center from 2009 to 2015. All insertions were contoured to include the vagina as a 3-dimensional structure. All contouring was performed on computed tomography or magnetic resonance imaging and used a 0.4-cm fixed brush to outline the applicator and/or packing, expanded to include any grossly visible vagina. The surface of the cervix was specifically excluded from the contour. High-dose-rate (HDR) and low-dose-rate (LDR) doses were converted to the equivalent dose in 2-Gy fractions using an α/β of 3 for late effects. The parameters D0.1cc, D1cc, and D2cc were calculated for all insertions and summed with prior external beam therapy. Late and subacute toxicity to the vagina were determined by the Common Terminology Criteria for Adverse Events version 4.0 and compared by the median and 4th quartile doses, via the log-rank test. Univariate and multivariate hazard ratios were calculated via Cox regression. Results: A total of 258 insertions in 62 women who underwent definitive radiation therapy including brachytherapy for cervical (n=48) and uterine cancer (n=14) were identified. Twenty HDR tandem and ovoid, 32 HDR tandem and ring, and 10 LDR tandem and ovoid insertions were contoured. The median values (interquartile ranges) for vaginal D0.1cc, D1cc, and D2cc were 157.9 (134.4-196.53) Gy, 112.6 (96.7-124.6) Gy, and 100.5 (86.8-108.4) Gy, respectively. At the 4th quartile cutoff of 108 Gy for D2cc, the rate of late grade 1 toxicity at 2 years was 61.2% (95% confidence interval [CI] 43.0%-79.4%) below 108 Gy and 83.9% (63.9%-100%) above (P=.018); grade 2 or greater toxicity was 36.2% (95% CI 15.8%-56.6%) below 108 Gy and 70.7% (95% CI 45.2%-96.2%) above (P=.004); and grade 3 or worse toxicity was 9.9% (95% CI 0.0%-23.6%) below 108 Gy and 30.0% (95% CI 4.7%-55.3%) above (P=.025). This association was maintained on multivariate analysis, independent of covariates such as applicator type, age, and dose rate. Conclusions: Vaginal dose was associated with all grades of vaginal toxicity. Confirmation at other sites using this methodology will be necessary to establish reproducibility; however, the integration of routine calculation of vaginal dose may be warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Comparison of As-loaded Dose Calculations to Measured Dose Rates

Demonstrating that the radiation dose fields surrounding spent nuclear fuel (SNF) storage and transportation systems meet the applicable limits set forth in 10 CFR 72 for storage and 10 CFR 71 for transportation is essential for the safe handling of radioactive material. The Used Nuclear Fuel-Storage, Transportation, and Disposal Analysis Resource and Data System (UNF-ST&DARDS) [2] is used to provide realistic estimates of SNF-related safety margins. The UNF-ST&DARDS dose rate analysis approach differs from that used in typical licensing approaches, which use design-basis assemblies with bounding source term characteristics to demonstrate the packaging design complies with the regulations. These bounding licensing approaches can increase the time needed to qualify fuel for loading into dry storage and the time a loaded system must wait prior to transportation. UNF-ST&DARDS dose rate assessments allow quantification of realistic, uncredited safety margins associated with actual fuel loading compared with the regulatory limits. While realistic estimation of the dose field surrounding SNF systems may allow for additional flexibility in operations, it is essential to understand how these predictions compare to measured doses. The U.S. Department of Energy Office of Integrated Waste Management and the Prairie Island Indian Community conducted a transportation dose assessment to estimate the site-specific incident-free radiation doses from shipping SNF by rail from the Prairie Island Nuclear Generating Plant (PINGP) through the Prairie Island Indian Community Reservation and Trust Land [5,6]. For that effort, the dose rates were obtained for 50 TN-40 and TN-40HT systems in storage configurations. This work compares the predicted dose rates from UNF-ST&DARDS as-loaded calculations with dose rates measured from 50 SNF storage systems at PINGP. The remainder of this paper discusses the data obtained for the evaluation, the modeling methods, and the results of the calculations.

spent nuclear fuel (SNF), UNF-ST&DARDS, Validation↗

Potential of Proton Therapy to Reduce Acute Hematologic Toxicity in Concurrent Chemoradiation Therapy for Esophageal Cancer

Purpose: Radiation therapy dose escalation using a simultaneous integrated boost (SIB) is predicted to improve local tumor control in esophageal cancer; however, any increase in acute hematologic toxicity (HT) could limit the predicted improvement in patient outcomes. Proton therapy has been shown to significantly reduce HT in lung cancer patients receiving concurrent chemotherapy. Therefore, we investigated the potential of bone marrow sparing with protons for esophageal tumors. Methods and Materials: Twenty-one patients with mid-esophageal cancer who had undergone conformal radiation therapy (3D50) were selected. Two surrogates for bone marrow were created by outlining the thoracic bones (bone) and only the body of the thoracic vertebrae (TV) in Eclipse. The percentage of overlap of the TV with the planning treatment volume was recorded for each patient. Additional plans were created retrospectively, including a volumetric modulated arc therapy (VMAT) plan with the same dose as for 3D50; a VMAT SIB plan with a dose prescription of 62.5 Gy to the high-risk subregion within the planning treatment volume; a reoptimized TV-sparing VMAT plan; and a proton therapy plan with the same SIB dose prescription. The bone and TV dose metrics were recorded and compared across all plans and variations with respect to PTV and percentage of overlap for each patient. Results: The 3D50 plans showed the highest bone mean dose and TV percentage of volume receiving ≥30 Gy (V{sub 30Gy}) for each patient. The VMAT plans irradiated a larger bone V{sub 10Gy} than did the 3D50 plans. The reoptimized VMAT62.5 VT plans showed improved sparing of the TV volume, but only the proton plans showed significant sparing for bone V{sub 10Gy} and bone mean dose, especially for patients with a larger PTV. Conclusions: The results of the present study have shown that proton therapy can reduced bone marrow toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗