Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IMPLANTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Preoperative treatment planning with intraoperative optimization can achieve consistent high-quality implants in prostate brachytherapy

Advances in brachytherapy treatment planning systems have allowed the opportunity for brachytherapy to be planned intraoperatively as well as preoperatively. The relative advantages and disadvantages of each approach have been the subject of extensive debate, and some contend that the intraoperative approach is vital to the delivery of optimal therapy. The purpose of this study was to determine whether high-quality permanent prostate implants can be achieved consistently using a preoperative planning approach that allows for, but does not necessitate, intraoperative optimization. To achieve this purpose, we reviewed the records of 100 men with intermediate-risk prostate cancer who had been prospectively treated with brachytherapy monotherapy between 2006 and 2009 at our institution. All patients were treated with iodine-125 stranded seeds; the planned target dose was 145 Gy. Only 8 patients required adjustments to the plan on the basis of intraoperative findings. Consistency and quality were assessed by calculating the correlation coefficient between the planned and implanted amounts of radioactivity and by examining the mean values of the dosimetric parameters obtained on preoperative and 30 days postoperative treatment planning. The amount of radioactivity implanted was essentially identical to that planned (mean planned radioactivity, 41.27 U vs. mean delivered radioactivity, 41.36 U; R{sup 2} = 0.99). The mean planned and day 30 prostate V100 values were 99.9% and 98.6%, respectively. The mean planned and day 30 prostate D90 values were 186.3 and 185.1 Gy, respectively. Consistent, high-quality prostate brachytherapy treatment plans can be achieved using a preoperative planning approach, mostly without the need for intraoperative optimization. Good quality assurance measures during simulation, treatment planning, implantation, and postimplant evaluation are paramount for achieving a high level of quality and consistency.

61 RADIATION PROTECTION AND DOSIMETRY↗

Correlated characterization of 20 Ne-implanted targets using nuclear reaction analysis, Rutherford backscattering spectrometry, and ion transport modeling

In this article, we present the preparation and characterization of a large sample of implanted noble gas targets for use in precision nuclear astrophysics measurements with intense proton beams. Tantalum and titanium backings were prepared using wet-acid etching, outgassed via resistive heating, and implanted with 20 Ne + beams from differing ion sources. These experimental targets were investigated using both nuclear reaction analysis techniques on the 1169-keV resonance in 20 Ne(p, $\gamma$) 21 Na and Rutherford backscattering spectrometry analysis with 2-MeV α-particle beams. Results from these analyses reveal small target-to-target variations in stoichiometry, while exhibiting excellent agreement independent of ion-beam analysis method. We also present a self-consistent validation of the nuclear reaction analysis results using ion transport simulations in TRIM-2013 that rely on input parameters from SIMNRA scattering-yield fits to Rutherford backscattering spectra. In addition to a complete description of the implantation profile, this analysis method provides an alternate solution for characterizing a large sample of implanted targets when no suitable resonances are available for nuclear reaction analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A methodology for customizing implantation profiles of light ions using a single thin foil energy degrader

We report a method was developed to quantify the spatial distribution and implantation depth of energy-degraded light ions with a thin foil rotating energy degrader for use during multiple ion beam irradiation. The methodology covers three physical phenomena: ions passing through the thin foil, ions travelling through the vacuum to the target, and ion implantation into the target, and accounts for the distribution of ions both in depth and in plane. The processes of energy straggling and scattering were calculated using SRIM. The effects of raster-scanning, and the geometry of the system were implemented in scripts handling the SRIM output files. Elastic backscattering (EBS) using 2.38 MeV H+ protons was used to measure the helium depth profiles after implantation with and without thin foil energy degradation. Defect analysis with transmission electron microscopy confirmed the implantation profiles measured with EBS and calculated with SRIM.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The effect of helium implantation on the deformation behaviour of tungsten: X-ray micro-diffraction and nanoindentation

Here, the effect of helium-implantation-induced defects on deformation behaviour is examined by comparing spherical nano-indents in unimplanted and helium-implanted regions of a tungsten single crystal. Helium-implantation increases hardness and causes large pileups. 3D-resolved X-ray micro-diffraction uniquely allows examination of the complex lattice distortions beneath specific indents. In the ion-implanted material we find reduced lattice rotations and residual strains due to indentation, indicating a more confined plastic zone. Together, our observations suggest that helium-induced defects initially act as efficient obstacles to dislocation motion, but are weakened by the subsequent passage of dislocations, causing a reduction in work hardening capacity.

36 MATERIALS SCIENCE↗

Low-cost plasma immersion ion implantation doping for Interdigitated back passivated contact (IBPC) solar cells

Here, we present progress to develop low-cost interdigitated back contact solar cells with pc-Si/SiO 2 /c-Si passivated contacts formed by plasma immersion ion implantation (PIII). PIII is a lower-cost implantation technique than traditional beam line implantation due to its simpler design, lower operating costs, and ability to run high doses (1E14-1E18 cm -2 ) at low ion energies (20 eV-10 keV). These benefits make PIII ideal for high throughput production of patterned passivated contacts, where high-dose, low-energy implantations are made into thin (20-200 nm) a-Si layers instead of into the wafer itself. For this work symmetric passivated contact test structures (~100 nm thick) grown on n-Cz wafers with pH3 PIII doping gave implied open circuit voltage (iV oc ) values of 730 mV with J o values of 2 fA/cm 2 . Samples doped with B 2 H 6 gave iV oc values of 690 mV and J o values of 24 fA/cm 2 , outperforming BF 3 doping, which gave iV oc values in the 660-680 mV range. Samples were further characterized by SIMS, photoluminescence, TEM, EELS, and post-metallization TLM to reveal micro- and macro-scopic structural, chemical and electrical information.

14 SOLAR ENERGY↗

Microstructure of Cs-implanted zirconia: Role of temperature

The aim of this study was to identify experimentally the phase which includes cesium in yttria stabilized zirconia (YSZ). The solubility and retention of cesium in YSZ were studied at high temperature (HT). Cesium was ion implanted (at 300 keV) into YSZ at room temperature (RT), 750 deg. C, or 900 deg. C at fluences up to 5x10{sup 16} cm{sup -2}. The temperature dependence of the radiation-induced damage and of the cesium distribution in YSZ single crystals was investigated by Rutherford backscattering spectrometry and ion channeling. Transmission electron microscopy (TEM) studies were performed in order to determine the damage nature and search for a predicted ternary phase of cesium zirconate. Whatever the implantation temperature, the thickness of the damaged layer increases inwards with ion fluence. At RT, amorphization occurs, caused by the high Cs concentration (7 at. %). In situ TEM during postannealing shows recrystallization of cubic zirconia after release of cesium. A high implantation temperature has a significant influence on the nature of radiation defects and on the retained Cs concentration. At HT, dislocation loops and voids are formed but no amorphization is observed whereas polygonization occurs at high fluence. The implanted cesium concentration reaches a saturation value of 1.5 at. % above which Cs can no longer be retained in the matrix and is then released at the surface. At that concentration, cesium forms a solid solution in YSZ; no other phase is formed, neither during irradiation nor after thermal annealing.

36 MATERIALS SCIENCE↗

Fracture in Hydrogen-Implanted Germanium

We have studied the mechanism of fracture in hydrogen-implanted Ge. First, the as-implanted Ge state and its evolution during subsequent annealing were characterized via TEM and FTIR-MIR spectroscopy. Results showed that the extended defects formation and growth follow the same basic mechanism in Ge as in Si, which is the reference material. Nevertheless, the global damage level in the implanted Ge layer is higher compared to Si. Second, the fracture step was studied via the fracture kinetics analysis, SIMS and AFM on the transferred layer. An activation energy comparable to the reported data from blistering studies was obtained. Just like in Si, the Cmax of H in Ge measured via SIMS was found to decrease during the fracture anneal. This decrease is associated with the formation of gaseous H{sub 2} that pressurizes the internal cavities and then contributes to the fracture. Finally, a high roughness of the Ge transferred layer was measured, which results from the large thickness of the implantation damaged zone.

36 MATERIALS SCIENCE↗

Optima XE Single Wafer High Energy Ion Implanter

The Optima XE is the first production worthy single wafer high energy implanter. The new system combines a state-of-art single wafer endstation capable of throughputs in excess of 400 wafers/hour with a production-proven RF linear accelerator technology. Axcelis has been evolving and refining RF Linac technology since the introduction of the NV1000 in 1986. The Optima XE provides production worthy beam currents up to energies of 1.2 MeV for P{sup +}, 2.9 MeV for P{sup ++}, and 1.5 MeV for B{sup +}. Energies as low as 10 keV and tilt angles as high as 45 degrees are also available., allowing the implanter to be used for a wide variety of traditional medium current implants to ensure high equipment utilization. The single wafer endstation provides precise implant angle control across wafer and wafer to wafer. In addition, Optima XE's unique dose control system allows compensation of photoresist outgassing effects without relying on traditional pressure-based methods. We describe the specific features, angle control and dosimetry of the Optima XE and their applications in addressing the ever-tightening demands for more precise process controls and higher productivity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Approaches to USJ Formation Beyond Molecular Implantation

As junction depth requirements approach sub 10 nm and the sensitivity to residual implant damage continues to increase, the capability to produce abrupt, shallow profiles while maintaining low residual damage becomes a difficult challenge. Implantation induced amorphization has been widely applied to reduce channeling tails of implanted dopant profiles for integrated circuit manufacturing. This has been required to meet aggressive junction depth targets. The problem, however, is that pre-amorphization creates high defect densities that remain near the former amorphous-crystalline interface post anneal. These end of range (EOR) defects become of greater concern as the industry begins to move towards millisecond anneal technologies. Millisecond anneal, while capable of close to diffusionless activation and abrupt junctions, has caused concern for its inability to fully repair these EOR defects. There has been a recent focus on removing traditional PAI through molecular implantation with limited success. Towards this end we have investigated alternative techniques to reduce EOR damage while maintaining the junction depth, sheet resistance and abruptness. Here we describe the results of two of these techniques. The subsequent reduction in EOR through the use of each process and the resultant Rs, junction depth and abruptness are detailed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The Effect of Amorphization Conditions on the Measured Activation of Source Drain Extension Implants

Un-patterned wafers were processed using low-dose Indium or medium-dose Germanium pre-amorphization implants (PAI) followed by p-type dopant implants of BF{sub 2} or carborane (CBH). The wafers were then annealed by RTA (spike), laser anneal (LSA) or combination of LSA and spike. Active dopant distributions calculated from SIMS and sheet resistance measurements compared favorably with those determined by differential Hall, which is a challenging technique for shallow profiles. The trends in B diffusion behavior and activation are discussed in relation to the different implant damage budgets, damage evolution during the anneals and presence of fluorine. In particular, for low thermal budget LSA only anneals, CBH implants appear to give higher activation than BF{sub 2} due to the absence of fluorine.

36 MATERIALS SCIENCE↗

Room-temperature ferromagneticlike behavior in Mn-implanted and postannealed InAs layers deposited by molecular beam epitaxy

We report on the magnetic and structural properties of Ar- and Mn-implanted InAs epitaxial films grown on GaAs (100) by molecular beam epitaxy and the effect of rapid thermal annealing (RTA) for 30 s at 750 deg. C. Channeling particle induced x-ray emission (PIXE) experiments reveal that after Mn implantation almost all Mn atoms are substitutional in the In site of the InAs lattice, like in a diluted magnetic semiconductor. All of these samples show diamagnetic behavior. However, after RTA treatment the Mn-InAs films exhibit room-temperature magnetism. According to PIXE measurements the Mn atoms are no longer substitutional. When the same set of experiments was performed with Ar as implantation ion, all of the layers present diamagnetism without exception. This indicates that the appearance of room-temperature ferromagneticlike behavior in the Mn-InAs-RTA layer is not related to lattice disorder produced during implantation but to a Mn reaction produced after a short thermal treatment. X-ray diffraction patterns and Rutherford backscattering measurements evidence the segregation of an oxygen-deficient MnO{sub 2} phase (nominally MnO{sub 1.94}) in the Mn-InAs-RTA epitaxial layers which might be the origin of the room-temperature ferromagneticlike response observed.

36 MATERIALS SCIENCE↗

Gold-implanted shallow conducting layers in polymethylmethacrylate

PMMA (polymethylmethacrylate) was ion implanted with gold at very low energy and over a range of different doses using a filtered cathodic arc metal plasma system. A nanometer scale conducting layer was formed, fully buried below the polymer surface at low implantation dose, and evolving to include a gold surface layer as the dose was increased. Depth profiles of the implanted material were calculated using the Dynamic TRIM computer simulation program. The electrical conductivity of the gold-implanted PMMA was measured in situ as a function of dose. Samples formed at a number of different doses were subsequently characterized by Rutherford backscattering spectrometry, and test patterns were formed on the polymer by electron beam lithography. Lithographic patterns were imaged by atomic force microscopy and demonstrated that the contrast properties of the lithography were well maintained in the surface-modified PMMA.

36 MATERIALS SCIENCE↗

Quantitative analysis of the lattice reconstruction of ion-implanted SiC after visible light laser irradiation

We report on a quantitative analysis of the effect of visible light laser irradiation (VLLI) on hexagonal ({alpha}) silicon carbide implanted with nitrogen and aluminum. In both cases of 4H and 6H polytypes we show that a short, but intense, irradiation with the 532 nm wavelength of a frequency-doubled neodymium: ytterbium aluminum garnet (Nd:YAG) laser results in a substantial reduction in the damage level produced by room temperature ion implantation. Up to now the recovery could not be made complete but, in the best conditions, it could reach {approx}80% of the initial damage value. This is not enough to qualify VLLI as a full activation step but, rather, suggests to use it as a new processing tool in order to lower the constraints of high temperature ion implantation or, after implantation performed at room temperature, to reduce the total budget for high temperature annealing and activation steps.

36 MATERIALS SCIENCE↗

The Structure of Sapphire Implanted with Carbon at Room Temperature and 1000 deg. C

Carbon was implanted into sapphire at various temperatures as part of a study of the different defect structures produced by a series of light ions. Implantations were made with 150 keV ions to fluences of 1x10{sup 16} and 1x10{sup 17} ions/cm{sup 2} at room temperature (RT) and 1000 deg. C. The defect structures were characterized using Rutherford backscattering-channeling (RBS-C) and transmission electron microscopy (TEM). The RBS-C spectra indicated low residual disorder for RT implantation at 1x10{sup 16} C{sup +}/cm{sup 2}. The de-channeling approached the random value at 1x10{sup 17} C{sup +}/cm{sup 2} and the TEM examination revealed a buried amorphous layer containing embedded sapphire nanocrystals. Damaged layers containing planar defects generally aligned parallel to the surface surrounded this layer. The RBS-C spectra for the sample implanted at 1000 deg. C with 1x10{sup 17} C{sup +}/cm{sup 2} suggested a highly damaged but crystalline surface that was confirmed by TEM micrographs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ga-implantation in Ge: Electrical activation and clustering

The electrical activation and clustering of Ga implanted in crystalline Ge was investigated in the (0.3-1.2)x10{sup 21} Ga/cm{sup 3} concentration range. To this aim, Ge samples implanted with 50 keV gallium, and annealed at several temperatures up to 650 deg. C, have been subjected to a detailed structural and electrical characterization. The substrate was maintained at 77 K during implantation to avoid the formation of the honeycomb structure that occurs during implantation at room temperature of heavy ions at high fluence. Secondary ion mass spectrometry analyses indicated a negligible Ga diffusion and dopant loss during the thermal annealing. The carrier concentration in the recrystallized samples measured by Hall effect showed a maximum concentration of active Ga of approx6.6x10{sup 20} Ga/cm{sup 3}. A remarkable Ga deactivation occurred with increasing the annealing temperature from 450 to 650 deg. C although the sheet resistance did not change considerably in this temperature range. It turned out that the carrier concentration reduction is balanced by the enhancement of the hole mobility that exhibits a steep variation with the concentration of the ionized scattering centers in this range. A simple model is proposed to explain the experimental results taking into account the thermally activated Ga clustering. These studies, besides clarifying the mechanism of Ga deactivation in Ge, can be helpful for the realization of future generation devices based on Ge.

36 MATERIALS SCIENCE↗

Current capabilities and future needs for semiconductor ion implantation (invited)

For many years the largest commercial application for particle accelerators has been semiconductor ion implantation. These tools differ from other accelerators in many respects. In particular they are automated to a very high degree and, in addition to technical performance requirements their success depends on other key metrics including productivity, availability and cost of ownership. These tools also operate with a large variety of species, four orders of magnitude of energy range and five orders of magnitude of dose range. The ion source is a key component of implanters with its own performance metrics that include beam current, lifetime, and materials cost. In this paper, we describe the primary applications for ion implantation and some of the beam line architectures that are used. We describe the ion source that has evolved for this application. Some key future challenges for implanter ion source development are also discussed.

36 MATERIALS SCIENCE↗

Influence of in situ applied ultrasound during Si{sup +} implantation in SiO{sub 2} on paramagnetic defect generation

Electron spin resonance (ESR) results are presented on the influence of in situ ultrasound treatment (UST) during implantation at 300 K of Si{sup +} ions into thermal SiO{sub 2} on (100)Si before and after subsequent high-temperature (T) annealing (1100 deg. C) intended to promote the formation of embedded Si nanoparticles. The as-implanted state exhibits high densities of three prominent types of point defects, including the SiO{sub 2}-specific S and E{sup '}{sub {gamma}} O-vacancy type centers, and an unknown broad ({approx_equal}20 G) signal at g{approx_equal}2.0026 denoted IS. The high-intensity S signal shows demagnetization shape effects, pointing to a distribution of high local density of defects over a thin layer. UST is observed to effectuate a drastic reduction in S and E{sup '}{sub {gamma}} centers, and elimination of IS beyond detection. This reveals a strong healing influence of in situ transferred ultrasound (US) energy on implantation-induced damage, here quantified and identified on atomic level in terms of mainly intrinsic paramagnetic point defects elimination, viz., Frenkel pair elimination, while all three initial signals disappear. Other types of defects surface after annealing of the non-US treated sample, including the SiO{sub 2}-specific EX defect signal and P{sub b}-type Si/SiO{sub 2} interface centers, the appearance of the latter providing direct ESR evidence for crystallization of the excess Si nanoparticles. The influence of the UST healing effect is kept up after subsequent annealing, now resulting in the absence of virtually all ESR-active centers. The drop in P{sub b}-type centers below the detection level in the UST annealed sample indicates improvement of the nanocrystalline-Si/SiO{sub 2} interface quality. The combination of UST with high-T annealing emerges as a highly efficient means to eradicate ion implantation damage in terms of intrinsic point defects.

36 MATERIALS SCIENCE↗

Bone Implant Interface Investigation by Synchrotron Radiation X-Ray Microfluorescence

Zinc is known to play a relevant role in growth and development; it has stimulatory effects on in vitro and in vivo bone formation and an inhibitory effect on in vitro osteoclastic bone resorption. The inorganic component of the bone tissue is nonstoichiometric apatite; changes in the composition of hidroxyapatite are subject of studies in order to improve the tissue response after implantation. The objective of this study was to investigate the effect of 0.5% zinc-containing hydroxyapatite in comparison to hydroxyapatite on osseous repair of rabbit's tibia. Cylinders (2x6 mm) of both materials were produced according to the specification of the International Organization for Standardization. Ethics Commission on Teaching and Research in Animals approved this project (HUAP-195/06). Fifteen White New Zealand rabbits were submitted to general anesthesia and two perforations (2 mm) were made in each tibia for implantation of zinc-containing hydroxyapatite cylinders (left tibia) and hydroxyapatite cylinders (right tibia). After 1, 2 and 4 weeks, the animals were killed and one fragment of each tibia with the cylinder was collected and embedded in a methacrylate-based resin and cut into slices (approx200 {mu}m thickness), parallel to the implant's long axis with a precision diamond saw for Synchrotron Radiation X-ray Microfluorescence investigation. The accomplishment of the standard procedures helped the planning, execution and the comparative analysis of the results. The chemical and physical properties of the biomaterials were modified after its implantation and the incorporation of zinc. Both materials are biocompatible and promote osteoconduction and favored bone repair.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗