At least 361 records · Page 20

Pilot-Scale Biorefinery: Sustainable Transport Fuels from Biomass and Algal Residues via Integrated Pyrolysis, Catalytic Hydroconversion and Co-processing with Vacuum Gas Oil

Beginning in 2010, UOP, along with the Department of Energy and other project partners, designed a pathway for an integrated biorefinery to process solid biomass into transportation fuel blendstocks. The integrated biorefinery (IBR) would convert second generation feedstocks into pyrolysis oil which would then be upgraded into fuel blendstocks without the limitations of traditional biofuels.

09 BIOMASS FUELS↗

Gridley Biofuels Project Final Report for Budget Period II

The Gridley Biofuels Project was initiated in 2003 as a Congressionally Directed Project (CDP). The City of Gridley was chosen for this project since it is an ideal, agriculture based town that is representative of many U.S. towns in which a wide variety of agriculture products are produced locally. The harvesting and processing of these products in the Gridley area creates millions of tons of biomass residues each year. Although these biomass residues have little or no commercial value, they are ideal feedstocks for the production of liquid fuels, power and other renewable products which can provide a significant revenue source to local farming communities. The primary objective of the Gridley Biofuels project was to support research, development, demonstration, and commercial design of an integrated biorefinery (IBR) that could efficiently and economically convert a wide variety of agriculture-based biomass residues to high-quality fuels, electric power and other products which providing a positive impact on the environment. This report describes work carried out during the second phase (budget period two: PB2) of the Gridley project which included technology feasibility (BP2a), conceptual design of the commercial plant during 2007-10, and final design of the commercial plant (BP2b) during 2014-15. The Gridley commercial plant is planned for deployment during 2020.

09 BIOMASS FUELS↗

Recovery Act – Integrated Pilot-Scale Biorefinery for Producing Ethanol from Hybrid Algae

As a scientific and engineering endeavor, the Algenol IBR Biorefinery project has been a success by almost any measure. The vision for the system evolved significantly over the course of the project, always due to recognized opportunities for improved performance, lower energy consumption, and reduced costs. Our commitment to thorough, realistic, techno-economic and life cycle assessments has been an essential element for system innovation, technology guidance, and change management of the overall facility. The biological tools developed during this program for cyanobacteria are second to none, and are the primary reason for the remarkable improvements in organism performance. The breakthrough was the successful transformation of our most robust wild type organism (AB1) early in 2012. That was followed by a series of improvements over the next several years that produced strains wherein over 80% of the fixed carbon was converted into ethanol. At the same time, our expertise in cultivation, physiology, process engineering, CO2 management, and photobioreactor design and manufacturing grew at a comparable pace. We learned enormous amounts from the various upsets, weather variations, contamination events, and new technology related disappointments. We overcame those challenges to produce fuel grade ethanol with a low carbon footprint, and are within striking distance of economic viability even with the challenges of low fossil fuel prices.

09 BIOMASS FUELS↗

Innovative Gasification to Produce Fischer-Tropsch Jet and Diesel Fuel

The primary objective of this project and the U.S. DOE’s integrated biorefinery (“IBR”) program was to demonstrate conversion of biomass and waste-derived feedstocks into military spec liquid fuels. Frontline’s proposed integrated process was to incorporate several novel technologies and innovative applications of existing technologies that would serve both to increase plant efficiency and also to lower the cost of the produced biofuels. The project was intended to demonstrate Frontline Bioenergy’s technologies for gasification and synthesis gas clean-up configuration to produce a syngas stream suitable for a proven Fischer-Tropsch (“F-T”) unit that would produce F-T intermediate products. These F-T intermediate products were to be upgraded to military spec diesel and jet fuel, including F76, JP5, and JP8. Specifically, these technologies consisted of: 1. Frontline’s PMFreeGas® ultra low particulate matter (PM) hot gas filtration technology 2. Application of Frontline’s TarFreeGas® ultra low-tar gasification technology 3. Frontline’s novel approach to syngas conditioning The proposed gasifier system was to operate at 10 tpd capacity while the F-T plant was capable of approximately one barrel per day. Although the gasifier output would have been roughly ten times the F-T plant’s required input, the 10 tpd capacity was chosen to enable scaling to commercial capacity. Project partners included i) SGC Energia, owner of the F-T technology and owner of the proposed demonstration site in Pasadena, Texas; ii) Stanley Consultants, a reputable engineering company that provided detailed electrical engineering services; and iii) Delphi Engineering & Construction LLC, a consulting company that provided project management advisory services. The integrated plant was never constructed due to lack of cost share funds. However, the commercialization plan and associated financial model suggested such a plant could be economically viable when the price of oil exceeds $70 per barrel. The price of feedstock plays a significant role in the profitability of the plant for a given value of oil. An integrated biorefinery capable of producing liquid transportation fuels and other chemical feedstocks would benefit the public by providing a sustainable pathway to convert domestically available feedstocks into fuels that might otherwise be imported from countries or regions of the world that are typically hostile to the United States.

09 BIOMASS FUELS↗

AI-Based Protective Relays for Electric Grid Resiliency

The protection systems (circuit breakers, relays, reclosers, and fuses) of the electric grid are the primary component responding to resilience events, ranging from common storms to extreme events. The protective equipment must detect and operate very quickly, generally <0.25 seconds, to remove faults in the system before the system goes unstable or additional equipment is damaged. The burden on protection systems is increasing as the complexity of the grid increases; renewable energy resources, particularly inverter-based resources (IBR) and increasing electrification all contribute to a more complex grid landscape for protection devices. In addition, there are increasing threats from natural disasters, aging infrastructure, and manmade attacks that can cause faults and disturbances in the electric grid. The challenge for the application of AI into power system protection is that events are rare and unpredictable. In order to improve the resiliency of the electric grid, AI has to be able to learn from very little data. During an extreme disaster, it may not be important that the perfect, most optimal action is taken, but AI must be guaranteed to always respond by moving the grid toward a more stable state during unseen events.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Equivalent Safety Evaluation of the 2021 Edition of the ASME Boiler and Pressure Vessel Code to Editions Incorporated by Reference in 49 CFR 192, 193, and 195

Federal safety standards for natural gas and hazardous liquid pipelines and liquid natural gas facilities incorporate rules and requirements for boiler and pressure vessel design and fabrication into 49 CFR Parts 192, 193, and 195 through the IBR process. The equivalent safety evaluations documented in this report demonstrate that boilers and pressure vessels in pipeline facilities that are designed and fabricated in accordance with rules and requirements specified in the 2021 edition do not violate the fundamental safety assumptions stated or implied in the 2007 edition of the ASME BPVC and therefore provide equivalent safety.

03 NATURAL GAS↗

Eastern Interconnection Wide-Area Oscillation Assessment and Study Report

To meet the government mandates such as Renewable Portfolio Standards (RPS), conventional synchronous generators with rotating mass are being displaced by inverter-based resources (IBRs), leading to high penetration of renewable energy sources (RES). As a result, the inherent properties and characteristics of the transformed generation mix may significantly impact the grid behaviour, and it is of paramount significance that the impact and the consequences of the resource mix change is thoroughly understood to adopt measures to maintain reliable grid operations. Of great concern is the inter-area low-frequency oscillation, which usually propagates through a large region and has a system-wide impact. Such oscillations may lead to unnecessary or inadvertent tripping of generators, that may be simply reacting to the oscillation originating from geographically remote sites. Such tripping of generators can lead to cascading outages, system split and load loss events. Over the years, several system-wide oscillation events have been observed across all three North American interconnections. This project titled Wide-area Oscillation Assessment and Trending Study, sponsored by the Office of Electricity (OE) of the Department of Energy (DOE), aims to conduct the required research to capture and investigate the potential changes in wide-area oscillatory performance of the system as a result of resource mix transition. The Pacific Northwest National Laboratory (PNNL) conducted this research and technical staff of Federal Energy Regulatory Commission (FERC) served as advisors to the project. The primary objective of this study is to assess whether there are significant trends in the power system wide-area oscillatory behaviours, as a result of the generation-mix changes due to the increased penetration of RES in the U.S. Eastern Interconnection (EI). The analysis presented in this report can serve as reference for future grid planning and operation of the EI system. This research conducted in this project evaluates the wide-area oscillatory behaviour of the EI, using a model-based approach for potential future resource mixes, and the measurement-based analysis with 21-month phasor measurement unit (PMU) time series. The oscillation modes in EI system along with the impact of the changes of the generation mix on the frequency and damping ratio (DR) of the oscillations have been studied.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Autonomous Inverter Controls for Resilient and Secure Grid Operation: Vector Control Design for Grid Forming

The project addresses both fundamental and practical challenges of GFM/GFL inverter control for the power grids with high inverter based resources (IBRs) penetration. A data- driven modeling technique is applied to accurately model dynamics of PWM inverters, including electromagnetic-transient (EMT). Systematic and integrative designs of grid- forming (GFM) and grid-following (GFL) primary controls are developed to guarantee system performance under either normal or abnormal operating conditions without violating constraints. This modeling and control framework provides black-start capability in case of an outage without relying on rotating generators, and its secondary control is also shown to enhance resilience against cyber-physical attacks.

14 SOLAR ENERGY↗

Leveraging PMU for Protection and Control

This presentation discusses the application of synchronized measurement in transmission system protection. The proposed wide area system protection (WASP) scheme uses PMU data to perform zonal current differential protection for the whole transmission system with high IBR penetration. This novel protection concept uses synchronized measurement, which is one of the key tasks proposed in the award DE-EE0010655.

14 SOLAR ENERGY↗

Application of Cyber-Informed Engineering for Protecting BESS

This white paper synthesizes an array of crucial grid services provided by BESS technology, assesses its architecture and communications, and presents a case study for analysis against the principles introduced by Cyber-Informed Engineering (CIE). Furthermore, in walking through the analysis, this paper presents a framework to evaluate risks and solutions when considering BESS components. Asset owners and buyers could perform this analysis to assess their BESS product implementations, alternative inverter-based resources (IBR), and energy management systems (EMS). Battery systems fulfill various roles contingent on the unique market demands and the specific challenges presented by regional grid infrastructures. These roles also vary due to the differing utility models for ownership and operation, which are adapted to meet regional and local capabilities and requirements. Concerns have been raised regarding the potential for adversaries to exploit knowledge of battery operational patterns to orchestrate decisive attacks. However, the security of operational data for these systems may not be the primary vulnerability, as much of this information is already well-understood within the community. Applying a modest degree of subject matter expertise can often yield valuable predictions regarding how a battery will respond under certain conditions, such as grid emergencies, high or low-temperature days, Public Safety Power Shutoff (PSPS) events, and outages. The operational characteristics of batteries are well-documented, and their capabilities, including the risks associated with misoperation and the resulting consequences, are published and understood within the industry. CIE practices represent the next step in gaining functional assurance and providing an acceptable level of risk, regardless of whether a battery vendor can support a trusted and validated supply chain. While this issue has exacerbated supply chain challenges, it is not an isolated condition. This foreign supply route is the primary source of BESS for the U.S. market. Significant efforts are underway through the Bipartisan Infrastructure Law (BIL) to change that. Still, strategic short-term operational mitigations are needed to ensure the security of our operational technology (OT) systems, which are enhanced by instilling trust and are separate from vendors implementing CIE principles.

25 ENERGY STORAGE↗

Utility-Scale Operational Consequences for Solar Grid Services

This report delves into the critical aspects of grid services provided by solar inverter-based resources (IBRs), with an emphasis on the evolving landscape of microgrids, virtual power plants (VPPs), aggregators, and distributed energy resource management systems (DERMS). As the energy sector undergoes a transformative shift towards more decentralized and resilient grid architectures, understanding the multifaceted risks associated with these technologies becomes paramount. The report categorizes these risks into organizational, technical, and procedural domains, providing a thorough risk assessment framework that stakeholders can utilize to anticipate and mitigate potential issues. In addressing the increasing complexity of grid interconnections, the report highlights the importance of Cyber-Informed Engineering (CIE). By embedding engineering controls and cybersecurity measures into the early stages of system design, this approach aims to fortify grid infrastructure against emerging cyber threats. The analysis includes an exploration of best practices and strategies for integrating CIE principles to enhance grid security and resilience. To provide practical insights, the report conducts a detailed consequence analysis of various grid services and cyber mitigations that can be applied through the interconnection process. This analysis evaluates the potential impacts of different failure modes and vulnerabilities, offering a clear understanding of the consequences that could arise from disruptions within the energy grid. The findings are further enriched by a series of case studies that illustrate real-world scenarios and lessons learned from past incidents. Through this comprehensive examination of grid services and their criticality, the report aims to prepare industry professionals with the knowledge and tools necessary to navigate the complexities of modern energy systems. By providing a comprehensive approach that includes risk assessment, cybersecurity, and consequence analysis, solar stakeholders can more effectively guarantee the reliability, efficiency, and security of the energy grid.

14 SOLAR ENERGY↗

Standard Library Plant Controller Model Specification for a Grid-Forming Hybrid Control Inverter-Based Resource (REPCGFM_C1)

This document describes a standard library plant controller model to interface with the grid-forming hybrid control inverter-based resource (IBR) model. The initial version of model specification was jointly developed by Pacific Northwest National Laboratory (PNNL), Tesla Energy, and EPRI, and it was revised multiple times later to incorporate suggestions from WECC MVS members. Tesla Energy provided main control algorithms to support the development of this model specification. This standard library model is developed to help the utility industry better understand the GFM technology. The model could be used to represent equipment for long-term planning studies where vendor-specific models are not available. As equipment matures and improves, standard library models will be updated to capture the new functionalities of GFMs. It is not intended that these models will always remain representative of all future GFM technologies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Standard Library Grid-Forming Hybrid Control Inverter-Based Resource Model Specification (REGFM_C1)

This document describes a standard library grid-forming (GFM) hybrid control inverter-based resource (IBR) model. The GFM hybrid control approach implements both a typical GFM control and a typical grid-following (GFL) control inside one single inverter simultaneously, so that it can take advantage of both methods without comprising the benefits of a typical GFM. The initial version of model specification was jointly developed by Pacific Northwest National Laboratory (PNNL), Tesla Energy, and EPRI, and it was revised multiple times later to incorporate suggestions from WECC MVS members. Tesla Energy provided main control blocks to support the development of this model specification. This standard library model is developed to help the utility industry better understand the GFM technology. The model could be used to represent equipment for long-term planning studies where vendor-specific models are not available. As equipment matures and improves, standard library models will be updated to capture the new functionalities of GFMs. It is not intended that these models will always remain representative of all future GFM technologies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Leveraging Cloud Platforms for Grid Modernization

Overview of the DOE funded Grid Operator Analytics and Assessment tools for Inverter-Based Resources Dominated Grid (GOAAT-IBR) Project, including insight to the lab setup and event analysis and dashboards that are being developed for this project.

Aminifar, Ph.D., Farrokh↗

Secure and Resilient Operations Using Open-Source Distributed Systems Platform (OpenDSP)

The goal of this project is to identify and address cybersecurity gaps by developing a multi-layer multi-channel cyber-physical defense and survival mechanism for operating distribution networks with high penetration of solar / inverter-based resource (IBR) / distributed energy resource (DER). The proposed security enhancements are built upon the distributed framework and solution architecture for both information technology (IT) and operational technology (OT) systems. The technical solutions consist of two composite functionalities and six layers: proactive defense (vulnerability assessment, communication protection, and attack detection, as layers 1-3), and adaptive self-healing (attack-resilient control, adaptive recovery, and resilient survival, as layers 4-6). These layers, built on and extended from DHS CISA Cyber Framework, establish an integrated and robust cybersecurity framework for operating large-scale distribution networks.

14 SOLAR ENERGY↗

Cyber-Informed Engineering Power Generation Guide [Slides]

The CIE for Power Generation: Insights and Case Studies guide is being developed to assist engineers at utilities, asset owner-operators developers, and cybersecurity teams to build in robustness and cyber resiliency into their designs using cyber-informed engineering practices. This guide will break out these topics including use cases by chapters for areas such as Nuclear, IBRs, Geothermal, natural gas, etc.

97 MATHEMATICS AND COMPUTING↗

Field Insights: Strengthening Digital Assurance Through On-Site Network Monitoring

The accelerating deployment of digital energy infrastructure, ranging from inverter-based resources (IBRs), battery energy storage systems (BESS), to advanced grid control platforms, has brought unprecedented visibility, flexibility, and efficiency to the electric grid. However, this digital transformation also introduces new cybersecurity challenges, particularly in the form of supply chain risks and operational blind spots at the grid edge. Over the past year, the Department of Energy’s Office of Cybersecurity, Energy Security, and Emergency Response (CESER), through its Rapid Risk Assessment initiative, along with the Grid Deployment Office (GDO), through its Technical Assistance for Digital Assurance (TADA) initiative, have supported a series of on-site network engagements led by Idaho National Laboratory (INL). These engagements, conducted in partnership with asset owners across the country, have focused on identifying real-world vulnerabilities and misconfigurations in operational environments, many of which are not detectable through remote assessments or traditional compliance audits. The goal of this report is to distill key findings and lessons learned during network hunt engagements from INL’s fiscal year (FY) 2024 - 2025. It is intended to help asset owners—regardless of their participation in the program—better understand the evolving threat landscape and adopt practical measures to secure their digital energy infrastructure.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

A Large-Scale Hardware Experiment Demonstration of Operating High Inverter-Based Resource Power Systems With Grid-Forming Inverters

This paper presents experimental hardware results from a microgrid system as the penetration level of grid-forming (GFM) inverters increases. The experiment aims to showcase the advantages of GFM inverters in enhancing system stability and to investigate the operational challenges in systems relying entirely on inverter-based resources (IBRs). Five test scenarios are devised to progressively increase GFM inverter penetration levels: 0% (S1), 19% (S2), 37% (S3), 68% (S4), and 100% (S5). To ensure consistency, identical loading conditions and dynamic events are applied across all scenarios. The conducted tests include load step changes, output variation of grid-following (GFL) inverters during islanded mode, transition operations (such as synchronization to the grid and islanding), and rateof- change-of-frequency (ROCOF) and voltage jump tests during grid-connected mode. Key findings from the tests are summarized as follows: (1) Scenario S1 proved most challenging for load steps, and GFL variations because of insufficient GFM capacity, leaving the diesel generator unable to handle transient ridethrough; (2) Scenario S5 was the most difficult for transition operations, because the lack of a diesel generator to maintain stiff bus voltage resulted in unexpected reactive power flows during synchronization, causing the point of common coupling (PCC) breaker to trip; (3) Scenarios S4 and S5 were particularly challenging for ROCOF tests because of minimal system inertia, leading to large transients that triggered breaker trips; and (4) Scenario S4 exhibited the strongest voltage recovery capability because of the presence of the diesel generator and a higher number of GFM inverters, both of which possess the highest capacity for reactive power injection.

24 POWER TRANSMISSION AND DISTRIBUTION↗