Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat conduction modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Analysis of contact conditions and microstructure evolution in shear assisted processing and extrusion using smoothed particle hydrodynamics method

Shear assisted processing and extrusion (ShAPE) is a solid-phase processing technique that adds an additional shear force as compared with a conventional extrusion approach. Recently, ShAPE has demonstrated the capability of extruding high-performance aluminum alloy 7075 (AA7075) tubes at speeds up to 12.2 m/min without surface tearing. However, the relationship among the ShAPE processing parameters, thermomechanical conditions, contact conditions, heat generation, and microstructure evolution remains primarily empirical because an insightful understanding of the associated physics is still lacking. To help elucidate these relationships, this work proposes a thermomechanical meshfree model for the first time for ShAPE processing of AA7075 using the smoothed particle hydrodynamics (SPH) method. The meshfree model is first validated thoroughly by experimental data in terms of material flow, die face temperature, and extrusion force with various processing parameters. The validated model is then used to analyze the steady-state contact conditions and heat generation rates during ShAPE processing. Distributions of the average grain size of AA7075 being extruded are calculated using the SPH model output. The meshfree model results reveal that extrusions conducted at lower temperatures and higher strain rates yield more refined grains and possibly higher material strength, which is also consistent with the experimental observations.

36 MATERIALS SCIENCE↗

PINCH POINT ANALYSIS OF GAS COOLERS IN TRANSCRITICAL R1336mzz(Z) HIGH-TEMPERATURE HEAT PUMPS

The majority of high-temperature heat pumps (HTHPs) operate subcritical vapor compression cycles, where the maximum sink temperature is limited by the critical temperature of refrigerants. In HTHPs with a sink temperature of ≥ 150°C, transcritical cycles overcome this limitation by rejecting heat in the supercritical regions of refrigerant. Supercritical refrigerants in gas coolers have a large temperature glide and substantial nonlinear variation in specific heat capacity vs. temperature. Closely matching the refrigerant glide temperature and the heat sink temperature profile greatly impacts the heat transfer characteristic of gas coolers and the overall performance of HTHPs. This study conducts a pinch point analysis for the gas cooling process of supercritical R1336mzz(Z) in HTHPs. A finite volume element model of a supercritical R1336mzz(Z) counterflow gas cooler is built and solved. This study evaluates the influences of operating conditions, including inlet and outlet of coolants, refrigerant evaporation temperature and superheat degree, pinch temperature difference, and heat rejection pressure, on the performance of HTHPs. The optimal discharge pressures in gas coolers are proposed for industrial spray dryers in providing drying air at 170°C−210°C. The results of the present study help design gas coolers in transcritical R1336mzz(Z) HTHPs.

Wang, Pengtao↗

Assessing the Heat Transfer Modeling Capabilities of CFD Software for Involute-Shaped Plate Research Reactors

The ongoing efforts to convert High-Performance Research Reactors (HPRRs) using Highly Enriched Uranium (HEU) to Low-Enriched Uranium (LEU) fuel require reliable thermal–hydraulic assessments of modified core designs. The involute-shaped fuel plates used in several major HPRRs present unique modeling challenges due to their compact core geometries and high heat flux conditions. This study evaluates the capability of three commercial CFD tools, STAR-CCM+, COMSOL, and ANSYS CFX, to predict cladding-to-coolant heat transfer using Reynolds-Averaged Navier–Stokes (RANS) methods within the thermal–hydraulic regimes of involute-shaped plate reactors. Broad sensitivity analysis was conducted across a range of reactor-relevant parameters using two turbulence models (k−ϵ and k−ω SST) and different near-wall treatment strategies. The results were benchmarked against the Sieder–Tate correlation and experimental data from historic studies. The codes produced consistent results, showing good agreement with the empirical correlation of Sieder–Tate and the experimental measurements. The findings support the use of these commercial CFD codes as effective tools for assessing the thermal–hydraulic performance of involute-shaped plate HPRRs and guide future LEU core development.

CFD↗

Numerical investigation of thermomechanical response of multiscale porous Ultra-High Temperature Ceramics

Recent advances in Ultra-High Temperature Ceramics (UHTC) manufacturing have permitted the development of multiscale porous UHTC microstructures. Within the target application of hypersonic vehicles, dense UHTCs are suitable for thermal protection on leading edges, whereas porous UHTCs may find a role in providing thermally insulated interfaces for temperature-sensitive interior components. Designing vehicles incorporating porous UHTCs requires a characterization of their thermomechanical properties across the full range of expected operating temperatures spanning –20 °C–2500 °C. This research represents a preliminary study in performing this characterization. Several numerical experiments are performed using a coupled thermomechanical implementation of the Material Point Method to determine the temperature dependence of effective material properties both with and without damage. Furthermore, complex time-dependent boundary conditions derived from known hypersonic flight profiles are simulated in order to probe the various couplings between deformation, damage and heat transfer. It is shown that the model reveals the importance of micro-buckling in determining effective material stiffness and thermal conductivity.

36 MATERIALS SCIENCE↗

Hydrogen Plus Other Alternative Fuels Risk Assessment Models (HyRAM+) (Technical Reference Manual V.4)

The HyRAM+ software toolkit provides a basis for conducting quantitative risk assessment and consequence modeling for hydrogen, methane, and propane infrastructure and transportation systems. HyRAM+ is designed to facilitate the use of state-of-the-art science and engineering models to conduct robust, repeatable assessments of safety, hazards, and risk. HyRAM+ includes generic probabilities for equipment failures, probabilistic models for the impact of heat flux on humans and structures, and experimentally validated first-order models of release and flame physics. HyRAM+ integrates deterministic and probabilistic models for quantifying accident scenarios, predicting physical effects, and characterizing hazards (thermal effects from jet fires, overpressure effects from delayed ignition), and assessing impact on people and structures. HyRAM+ is developed at Sandia National Laboratories to support the development and revision of national and international codes and standards. HyRAM+ is a research software in active development and thus the models and data may change. This report will be updated at appropriate developmental intervals. This document provides a description of the methodology and models contained in HyRAM+ version 4.0. The most significant change for HyRAM+ version 4.0 from HyRAM version 3.1 is the incorporation of other alternative fuels, namely methane (as a proxy for natural gas) and propane into the toolkit. This change necessitated significant changes to the installable graphical user interface as well as changes to the back-end Python models. A second major change is the inclusion of physics models for the overpressure associated with the delayed ignition of an unconfined jet/plume of flammable gas.

02 PETROLEUM↗

Preliminary Pilot-scale Study and Techno-economic Analysis of Chemical Heat Pump with Conventional Nuclear Reactors

The energy economy is continually evolving, particularly in terms of primary energy sources, their conversions to useful forms such as electricity and heat, and their utilization in different sectors, in response to socio-political factors. Because nuclear source is clean and non-carbon-emitting energy source, it is crucial to consider its role in the evolution of the energy economy. A pilot-scale study was conducted for Chemical Heat Pump (ChHP) system at three different scales (25-, 100-, and 1000-kW thermal outputs) using steady state thermal model. To establish the viability of selling heat rather than electricity alone, techno-economic analysis was undertaken for advanced Small Modular Reactor (SMR), and SMR paired with varied thermal output ChHP systems was referred to as the nuclear hybrid energy system (NHES) in this study. Using the U.S. Energy Information Administration statistics, pricing for electricity and natural gas were anticipated for U.S. regions (California, Northwest, Midwest, Southwest, New England, and PJM). Based on thermal output from ChHP, advanced SMR with 100 MWth and four alternative NHES scenarios were explored, namely 50-, 10-, 5-, and 1-MWth. Net present value, payback period, discounted cash flow return, and levelized cost of energy were evaluated for all scenarios. Based on the economic analysis, selling heat to high-temperature industrial processes is more profitable compared to selling electricity only. Higher carbon taxes showed significant improvement in economic parameters for NHESs. Providing heat to high-temperature industries could be beneficial, helping to reduce the greenhouse gas emissions by slashing the fossil fuel consumption.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermal Management of Wide-Bandgap Semiconductor Amplifiers Used for Plasma Heating and Control

Princeton Fusion Systems (PFS) has designed, built, and tested a Load Switch printed circuit board (PCB) to demonstrate the capabilities of 2 kV silicon carbide (SiC) cascodes in development by Qorvo towards plasma heating and control applications. Initial tests have been conducted at low power (~100 W) for validation with thermal finite element analysis (FEA) modeling performed by the National Renewable Energy Laboratory (NREL). Comparisons of experimental data with the thermal modeling results, along with considerations for operating in plasma systems, will be discussed.

CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND SU↗

Finite Element Modeling of Diffusion in Fractured Porous Media by Using Hierarchical Material Properties

Abstract Fractured porous media challenge modeling approaches due to high computational costs and excessive mesh refinement imposed by the extreme scale variability of fractures and the heterogeneity of the surrounding porous rock. To overcome such difficulties, we utilize the hierarchical finite element method ( Hi ‐FEM) that has been developed previously to simulate the electrical potential distribution in complex geologic environments. The method employs the hierarchical basis functions in classical finite element analysis to enable representation of material properties on each dimensional component of a given 3D unstructured finite element, thereby inherently allowing for interactions at the boundary between fracture and a host rock. In this study, we extend its application to transient fluid flow and heat conduction in the Laplace domain. Time‐domain flow solutions are obtained by numerical inverse Laplace transform. We evaluate the accuracy of the method using different flow models and demonstrate its robustness for large‐scale, rock mass models featuring complex fracture networks. Moreover, for the computation of nodal Darcian velocity fields in fractured porous media where the fractures are represented as 2D features, a new approach that employs the Yeh's Galerkin model for both volume and facet elements is proposed. Results show that Hi ‐FEM can produce accurate flow solutions for fractured porous media without any need of coupling or transfer mechanism while still being computationally economical and numerically robust, even for large‐scale simulations.

Beskardes, G. D.↗

Chemical composition based machine learning model to predict defect formation in additive manufacturing

With a goal of exploiting additive manufacturing to improve the manufacturing of existing reactor materials, we developed a chemical composition-based machine learning model to predict the printability of any given alloy in laser powder bed fusion (L-PBF) using experimental data from peer-reviewed literature. We defined printability as the ability to avoid defects like cracking, balling, porosity, and lack of fusion, that are caused by thermal stresses (during solidification or liquation), molten pool disintegration into disconnected small beads or lack of heat input respectively. Our models predict the tendency of balling defect formation and porosity percentage for a given composition, under a given set of processing conditions. To predict the likelihood of balling defect, three models: a random forest classifier, a gradient boost regressor and a neural network were trained on a dataset containing both traditional alloys and high entropy alloys. The neural network model showed the highest accuracy of 92.3 % in predicting the balling defect formation. A random forest regressor, gradient boost regressor and neural network were trained and tested on a dataset of various alloys to predict porosity. The random forest regressor showed the best predictions with an R 2 score of 0.97. The models also revealed the relative importance of the input descriptors on defect-formation tendency. Of particular significance was the identification of carbon as an important element in determining the occurrence of balling and percent porosity in alloys like steel, as well as being moderately important to the percentage porosity in other alloys as well as steel. Manganese was also identified as a key descriptor for the percentage of porosity in steel and other alloys. Manganese’s low thermal conductivity and consistent presence in the dataset is the likely cause for its contribution. Carbon’s role is attributable to its relatively high specific heat and high melting temperature. In conclusion, our model serves as a swift, chemistry-based tool to design experiments and find modified compositions better suited for additive manufacturing.

36 MATERIALS SCIENCE↗

Energy Analysis of Combi Heat Pump System Configurations for Space Conditioning and Domestic Hot Water Heating in Residential Buildings

Combi heat pump systems, also referred to multifunctional variable refrigerant flow heat recovery (MF-VRFHR) systems, are specifically designed for residential applications to manage both space conditioning and domestic hot water (DHW). They have attracted attention due to their potential for energy conservation through heat recovery. The incorporation of a hot water tank introduces various system configurations, each characterized by distinct pros and cons related to energy efficiency, system stability, and maintenance. Despite this, a critical gap exists as the specific energy performance remains unquantified under diverse operational modes (e.g., heating mode and heat recovery mode). This paper aims to bridge this gap by conducting a comprehensive comparative analysis of two prevalent system configurations while considering feasible proposed control logics. Configuration 1 integrates a separate hot water tank and a refrigerant-to-water heat exchanger (HEX), also known as a Hydro Kit while Configuration 2 incorporates a refrigerant-wrapped hot water tank. To facilitate this analysis, we developed high-fidelity system models for both configurations in Modelica, capturing system dynamics and detailed control sequences effectively. These system models were built upon the TIL library for HVAC equipment components and the Buildings library for residential building thermal load calculations. The validation of the simulation testbed utilized data from experiments conducted in the PNNL lab home for Configuration 1. To establish the simulation testbed for Configuration 2, we extended the modeling setup derived from Configuration 1. This extension specifically involved substituting the separate hot water tank and Hydro Kit with a refrigerant-wrapped hot water tank of similar sizing sourced from an actual product. The simulation analysis of heating-only and heat recovery modes reveals that Configuration 2 not only saves energy and maintains warmer tank temperatures but also demonstrates faster water heating capabilities. This is attributed to decreased energy loss and improved heat transfer. The study encompasses a wide range of scenarios, considering diverse thermal loads and water usage patterns across heating and heat recovery modes. Overall, the comprehensive results indicate that Configuration 2 achieves energy savings ranging from 3.5% to 12.2% compared to Configuration 1, depending on factors such as water usage patterns, thermal loads, and operational modes.

Configuration, Comparison, Multi-functional, Resid↗

Development and Experimental Validation of a Heat Transfer Model for Spilled Molten Salt Pools

A spill of radionuclide-bearing molten salt is one of the major postulated events that needs to be analyzed for liquid fluorine salt-cooled high-temperature reactor (FHR) or molten salt reactor licensing purposes. In this postulated event, radioactive source term materials (RSTMs) in the molten salt are discharged from the reactor vessel to the reactor building. The release of RSTMs from the spilled salt pool to the gas space in the reactor building is expected to be controlled by the cooling behavior of the spilled salt, including the growth and shrinkage of the solid crust on the surface of the spilled salt pool. This paper presents a simulation model for spilled salt pool heat transfer and validation efforts. The validation data come from two molten salt spill tests that were performed recently: the PELE2 test by the Rapid Experimental Laboratory of Kairos Power LLC (KP) and the Argonne salt cooling test conducted by Argonne National Laboratory. The former was a large-scale test involving kilograms of molten spilled FLiNaK salt, and the latter was a relatively smaller-scale test targeting various processes associated with a salt spill event. Both tests generated valuable data sets that can be used to assess salt cooling and validate evaluation models. This paper provides a new one-dimensional model that can simulate the cooling process of a spilled salt pool as well as the thermal responses of heat structures, such as the stainless steel liner and the concrete below the salt. The model has been implemented as part of KP-SAM code, which is a branch of the systems code SAM specific to KP FHR. In conclusion, the simulation results of the model are compared with the data of the PELE2 and Argonne tests, and reasonable agreements are observed between the model and test data.

heat transfer model↗

Modeling and Optimal Design of a Desalination System Integrated Between a Glass-Covered Solar Collection Water Chamber and a Heat Dissipating Chimney

Abstract Solar thermal energy is trapped in a glass-covered water chamber/basin to provide the heat for evaporation of brackish water in a novel desalination system. To harvest clean water, a chimney is integrated with the water basin, which draws air into the chamber to be humidified by the vapor and then being ventilated via buoyance force. Uniquely, thermal conductive metal sheet is recommended to make the chimney, which allows the vapor in the humid air condenses easily when flowing up. The condensate at the inner wall of the chimney flows down to be collected as clean water. Mathematical modeling and numerical computation have been carried out to delineate the coupling of the buoyance-force-driven flow with the heat and mass transfer of air and water in the solar collection chamber and the condensation of vapor in the heat-dissipating chimney. The objective of the simulation and optimization of the system is to find the best match of the dimensions of the water chamber with a chimney to maximize the production of clean water and energy efficiency. The model has been used to simulation several cases (of water from 40 °C to 50 °C) with available experimental data from the authors’ previous work, and the agreement was satisfactory. The optimization studies found that there is a maximum air flowrate corresponding to a critical chimney height due to the requirement that the chimney is designated to dissipate heat as much as possible to condense water vapor. With the chimney height greater than the critical height, the airflow rate will have a slight decrease. Nevertheless, higher than a critical height is still needed for a chimney to condense more moisture. Optimized chamber diameters at different chimney heights are provided for reference of optimal system designs.

Engineering↗

Determining the electrical conductivity of metals using the 2 MA Thor pulsed power driver

We present the development of a pulsed power experimental technique to infer the electrical conductivity of metals from ambient to high energy density conditions. The method is implemented on Thor, a moderate scale (1–2 MA) pulsed power driver. The electrical conductivity of copper at elevated temperature (>4000 K) and pressure (>10 GPa) is determined, and a new tabular material model is developed, guided by density functional theory, which preserves agreement with existing experimental data. Minor modifications (<10%) are found to be necessary to the previous Lee–More–Desjarlais model isotherms in the vicinity of the melt transition in order to account for observed discrepancies with the new experimental data. An analytical model for magnetic direct drive flyer acceleration and Joule heating induced vaporization based on the Tsiolkovsky “rocket equation” is presented to assess sensitivity of the method to minor changes in electrical conductivity.

47 OTHER INSTRUMENTATION↗

Study of Radiative Heat Transfer and Flow Physics from Medium-scale Methanol Pool Fire Simulations [Slides]

Analysis of methanol pool fire conducted as part of validation study for SIERRA/Fuego. Radiation model was effectively calibrated by modifying radiation model parameters for methanol. Computing integrated buoyancy flux, entrainment rate, and turbulent kinetic energy allowed for evaluation of less typical quantities in this validation study. Quantities were compared with experimental data or correlations and generally showed agreement. TKE needed fine mesh to be computed accurately. Predicted flame height less sensitive to variations in mixture fraction than temperature. Mixture fraction is a preferable threshold variable for this application.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

HP-FLEX: Field demonstration of the semantics-driven configuration of a Model Predictive Control system to make heat pumps flexible

Model Predictive Control (MPC) has demonstrated significant potential for optimizing building operations and enabling demand flexibility. However, the widespread adoption of MPC is hindered by complex manual configuration and commissioning processes that must be conducted by control experts working alongside building operators. These challenges drive up costs and reduce scalability, particularly when technical human resources and building automation systems are limited, such as in small and medium commercial buildings (SMCBs). This paper demonstrates how semantic standards, specifically ASHRAE 223P, can accelerate the adoption of MPC applications for load flexibility in SMCBs. The authors present a replicable control framework, titled “HP-FLEX” that leverages a building’s semantic model to bootstrap the required data configuration for an MPC controller developed for optimizing heat pump systems as flexible grid resources. The semantic model helps streamline the deployment workflow, particularly for site setup, data/control commissioning, and model setup. This integration enhances portability, transferability, and scalability of the HP-FLEX MPC, which has been developed to support MPC-based supervisory HVAC controllers in SMCBs. Additionally, the paper details the required building and thermostat metadata information to enable the HP-FLEX MPC based on field demonstrations. The new workflow was tested in a small commercial building located in California, U.S., and demonstrated a load shifting performance of 9% based on a dynamic pricing signal that varies by the hour. This work provides a practical pathway for transitioning sophisticated building applications from custom to standardized semantic representations, supporting the broader adoption of advanced control strategies like MPC. The framework also establishes a foundation for evolving metadata requirements as applications mature while maintaining compatibility with industry standards.

Paul, Lazlo↗

HP-FLEX: Field Demonstration of the Semantics-Driven Configuration of a Model Predictive Control System to Make Heat Pumps Flexible

Model Predictive Control (MPC) has demonstrated significant potential for optimizing building operations and enabling demand flexibility. However, the widespread adoption of MPC is hindered by complex manual configuration and commissioning processes that must be conducted by control experts working alongside building operators. These challenges drive up costs and reduce scalability, particularly when technical human resources and building automation systems are limited, such as in small and medium commercial buildings (SMCBs). This paper demonstrates how semantic standards, specifically ASHRAE 223P, can accelerate the adoption of MPC applications for load flexibility in SMCBs. The authors present a replicable control framework, titled “HP-FLEX” that leverages a building’s semantic model to bootstrap the required data configuration for an MPC controller developed for optimizing heat pump systems as flexible grid resources. The semantic model helps streamline the deployment workflow, particularly for site setup, data/control commissioning, and model setup. This integration enhances portability, transferability, and scalability of the HP-FLEX MPC, which has been developed to support MPC-based supervisory HVAC controllers in SMCBs. Additionally, the paper details the required building and thermostat metadata information to enable the HP-FLEX MPC based on field demonstrations. The new workflow was tested in a small commercial building located in California, U.S., and demonstrated a load shifting performance of 9% based on a dynamic pricing signal that varies by the hour. This work provides a practical pathway for transitioning sophisticated building applications from custom to standardized semantic representations, supporting the broader adoption of advanced control strategies like MPC. The framework also establishes a foundation for evolving metadata requirements as applications mature while maintaining compatibility with industry standards.

Paul, Lazlo↗

Computational and Experimental Validation of Fractal-Fin, Dimpled Solar Heat Collector

A 3 foot x 3 foot x 3 foot aluminum solar collector was manufactured using computer numerical control. The interior of the device included six triangular dimpled fins for enhanced heat transfer. The interior vertical wall on the south side was also dimpled. The solar collector working fluid was based on water, and the collector consisted solely of passive heat transfer mechanisms (no moving parts), making it ideal for off-the-grid and rural applications. Two types of heat transfer experiments were conducted. One experiment had external flat heaters attached on the top and the front side, while the other four sides were insulated. Except for the bottom surface, the second experiment had all its exterior surfaces sprayed with black solar paint to collect as much solar heat as possible. Temperature data as a function of time was collected using 14 thermocouples spread strategically throughout the solar collector. In addition, computational fluid dynamics (CFD) simulations were conducted using the dynamic Smagorinsky large eddy simulation turbulence model. The first simulation considered that both the top and front surfaces were exposed to a fixed temperature of 313.7 K (105 °F), while the remaining four surfaces were insulated. For the second simulation, all conditions were the same, except that the temperature for both heated surfaces was raised to 350 K (170.3 °F). The two temperatures are expected to bound the solar collector operational temperature during the late- Spring, Summer, and early-Fall months. The solar collector design, experimental data, CFD output, and a discussion of five manufacturing approaches and costs are documented in this report.

14 SOLAR ENERGY↗

Transport coefficient sensitivities in a semi-analytic model for magnetized liner inertial fusion

Performance of magnetized liner inertial fusion (MagLIF) experiments is highly dependent on transport processes including magnetized heat flows and magnetic flux losses. Magnetohydrodynamic simulations used to model these experiments require a choice of model for the transport coefficients, which are the constants of proportionality relating driving terms, such as temperature gradients and currents, to the associated heat and magnetic field transport. The coefficients have been the subject of repeated recalculation using various methods throughout the years. Using a semi-analytic MagLIF model, we compare models for the transport coefficients. The choice of model modifies magnetic-flux losses caused by the Nernst thermoelectric effect and thermal conduction losses. We present simulated results from parameter scans conducted in order to compare the effects of the different models on parameters of interest in MagLIF. In some regions of parameter space, discrepancies of up to 38% are found in integrated quantities like the fusion yield. These results may serve as a guide for experimental validation of the various models, particularly as laser preheat energies and initial axial field strengths are increased on MagLIF experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗