Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heart Rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Physiological coherence in healthy volunteers during laboratory‐induced stress and controlled breathing

Abstract Physiological coherence has been related with a general sense of well‐being and improvements in health and physical, social, and cognitive performance. The aim of this study was to evaluate the relationship between acute stress, controlled breathing, and physiological coherence, and the degree of body systems synchronization during a coherence‐generation exercise. Thirty‐four university employees were evaluated during a 20‐min test consisting of four stages of 5‐min duration each, during which basal measurements were obtained (Stage 1), acute stress was induced using validated mental stressors (Stroop test and mental arithmetic task, during Stage 2 and 3, respectively), and coherence states were generated using a controlled breathing technique (Stage 4). Physiological coherence and cardiorespiratory synchronization were assessed during each stage from heart rate variability, pulse transit time, and respiration. Coherence measurements derived from the three analyzed variables increased during controlled respiration. Moreover, signals synchronized during the controlled breathing stage, implying a cardiorespiratory synchronization was achieved by most participants. Hence, physiological coherence and cardiopulmonary synchronization, which could lead to improvements in health and better life quality, can be achieved using slow, controlled breathing exercises. Meanwhile, coherence measured during basal state and stressful situations did not show relevant differences using heart rate variability and pulse transit time. More studies are needed to evaluate the ability of coherence ratio to reflect acute stress.

Mejía‐Mejía, Elisa↗

Effect of Blockade of Nitric Oxide Synthesis on the Renin Secretory Response to Frusemide in Conscious Rabbits

The enzyme nitric oxide synthase is present in the macula densa and may participate in the control of renin secretion by the adjacent juxtagiomerular cells. In the present study, we investigated the effect of inhibiting nitric oxide synthase on the renin secretory response to frusemide, which stimulates renin secretion by blocking Na(+)-K(+)-2Cl(-) co-transport in the macula densa. Injection of frusemide in 12 conscious rabbits elicited a transient increase in mean arterial pressure from 84 +/- 2 to 92 +/-3 mm Hg at 5 min (P less than 0.01) and a sustained increase in heart rate from 246 +/- 6 to 281 +/- 10 beats/min at 45 min (P less than 0.01). Plasma renin activity increased from 8.0 +/- 1.2 to 14.3 +/- 1.8, 12.4 +/- 1.6 and 11.6 +/- 1.5 pmol/2h ml at 15, 30 and 45min respectively (P less than 0.01). There were no changes in plasma sodium and potassium concentrations or osmoiality. Inhibition of nitric oxide synthase with N(sup G)-nitro-L- arginine methyl ester increased mean arterial pressure by 9 mm Hg, decreased heart rate and plasma renin activity, and markedly suppressed the renin response to frusemide (from 4.6 +/- 0.7 to 7.6 +/- 1.7, 4.7 +/- 1.0 and 4.6 +/- 0.7pmol/2h ml at 15, 30 and 45 min respectively). By contrast, infusion of an equipressor dose of phenylephrine did not suppress the renin response to frusemide. Histochemical studies with the NADPH diaphorase technique confirmed the presence of nitric oxide synthase in the macula densa, and suggested that enzyme activity is increased by treatment with frusemide. These results are consistent with a role for the L- arginine-nitric oxide pathway in the modulation of renin secretion by the macula densa.

Reid, Ian A.↗

Cardiovascular dynamics associated with tolerance to lower body negative pressure

The purpose of this investigation was to identify cardiovascular responses associated with tolerance to lower body negative pressure (LBNP). Eighteen men, ages 29-51 years, were categorized as high (HT) or low (LT) LBNP-tolerant based on a graded presyncopal-limited LBNP exposure criterion of -60 mm Hg relative to ambient pressure. Groups were matched for physical characteristics and pre-LBNP cardiovascular measurements, with the exceptions of greater (p less than 0.05) end-diastolic volume and cardiac output in the HT group. During peak LBNP, cardiac output was similar in both groups, although the HT group displayed a greater heart rate (p less than 0.05). In both groups, venous return appeared to limit cardiac output resulting in decreased arterial pressure. Tolerance to LBNP did not appear solely dependent on the absolute amount of blood pooled in the legs since the HT group demonstrated a greater (p less than 0.05) peak LBNP-induced increase in midthigh-leg volume. Greater tolerance to LBNP was associated with a larger pre-LBNP cardiac output reserve and higher compensatory increases in heart rate and peripheral resistance.

Sather, T. M.↗

Effect of standing on neurohumoral responses and plasma volume in healthy subjects

Upright posture leads to rapid pooling of blood in the lower extremities and shifts plasma fluid into surrounding tissues. This results in a decrease in plasma volume (PV) and in hemoconcentration. There has been no integrative evaluation of concomitant neurohumoral and PV shifts with upright posture in normal subjects. We studied 10 healthy subjects after 3 days of stable Na+ and K+ intake. PV was assessed by the Evans blue dye method and by changes in hematocrit. Norepinephrine (NE), NE spillover, epinephrine (Epi), vasopressin, plasma renin activity, aldosterone, osmolarity, and kidney response expressed by urine osmolality and by Na+ and K+ excretion of the subjects in the supine and standing postures were all measured. We found that PV fell by 13% (375 +/- 35 ml plasma) over approximately 14 min, after which time it remained relatively stable. There was a concomitant decrease in systolic blood pressure and an increase in heart rate that peaked at the time of maximal decrease in PV. Plasma Epi and NE increased rapidly to this point. Epi approached baseline by 20 min of standing. NE spillover increased 80% and clearance decreased 30% with 30 min of standing. The increase in plasma renin activity correlated with an increase in aldosterone. Vasopressin increased progressively, but there was no change in plasma osmolarity. The kidney response showed a significant decrease in Na+ and an increase in K+ excretion with upright posture. We conclude that a cascade of neurohumoral events occurs with upright posture, some of which particularly coincide with the decrease in PV. Plasma Epi levels may contribute to the increment in heart rate with maintained upright posture.

Non-NASA Center↗

A tethering system for direct measurement of cardiovascular function in the caged baboon

A device suitable for the continuous measurement of physiological activity in large, conscious monkeys has permitted the direct recording of systemic arterial blood pressure and heart rate in caged baboons. The device comprises a lightweight fiberglass backpack, retained in place on the baboon by a thoracic elastic band and shoulder straps, and a flexible stainless steel tether connecting the pack to an electrocannular slip-ring in the top center of the baboon's cage. A chronically indwelling arterial catheter inserted retrograde into the abdominal aorta via the internal iliac artery and connected to a small pressure transducer on the pack provides direct measurement of blood pressure and heart rate. Body fluids can be sampled or drugs administered via an indwelling catheter in the inferior vena cava. Electrical and fluid connections between the fiberglass pack and recording and infusion equipment located outside the cage pass through the flexible tether and remain protected from the subject. The reliability of the tethering system has been demonstrated in physiological, pharmacological, and behavioral experiments with baboons.

Byrd, L. D.↗

Uncoupling of the baroreflex by N(N)-cholinergic blockade in dissecting the components of cardiovascular regulation

Systemic administration of adrenergic agonists and nitric oxide donors is used extensively to determine cardiovascular receptor sensitivity. Conclusions regarding receptor sensitivity in the presence of the baroreflex may be misleading. In 8 normal volunteers, we determined the heart rate and blood pressure changes after incremental bolus doses of isoproterenol, phenylephrine, and sodium nitroprusside before and during neuronal nicotinic cholinergic (N(N)-cholinergic) blockade with trimethaphan. Results are given as median (25th/75th percentile). With trimethaphan, the baroreflex slope (as determined by bolus doses of nitroprusside and phenylephrine) decreased from 24 (22/26) to 0.00 (0.00/0.09) ms/mm Hg (P<0.01). The dose of isoproterenol that decreased systolic blood pressure (SBP) 12.5 mm Hg changed from 0.61 (0.51/5.3) to 0.17 (0.12/0.21) microg (P<0.01); the dose required to increase heart rate 12.5 bpm changed from 0.22 (0.17/0.41) to 0.74 (0.33/2.3) microg (P<0.01). The dose of nitroprusside required to decrease SBP 12.5 mm Hg changed from 2.3 (1.3/3.4) to 0.18 (0.14/0.24) microg/kg (P<0.01). The dose of phenylephrine required to increase SBP 12.5 mm Hg changed from 135 (110/200) to 16 (10/30) microg (P<0.01). We conclude that the efferent arc of the baroreflex can be completely interrupted with N(N)-cholinergic blockade. Estimation of adrenoreceptor sensitivity and sensitivity to nitric oxide donors by systemic administration of agonists is severely confounded by baroreflexes. Uncoupling of the baroreflex by N(N)-cholinergic blockade may be a useful method to obtain an integrated measure of adrenergic receptor sensitivity and sensitivity to nitric oxide donors in humans. This approach would permit the comparison of normal and abnormal physiological states without the "noise" of baroreflex buffering.

NASA Discipline Regulatory Physiology↗

Effects of exercise pressor reflex activation on carotid baroreflex function during exercise in humans

1. This investigation was designed to determine the contribution of the exercise pressor reflex to the resetting of the carotid baroreflex during exercise. 2. Ten subjects performed 3.5 min of static one-legged exercise (20 % maximal voluntary contraction) and 7 min dynamic cycling (20 % maximal oxygen uptake) under two conditions: control (no intervention) and with the application of medical anti-shock (MAS) trousers inflated to 100 mmHg (to activate the exercise pressor reflex). Carotid baroreflex function was determined at rest and during exercise using a rapid neck pressure/neck suction technique. 3. During exercise, the application of MAS trousers (MAS condition) increased mean arterial pressure (MAP), plasma noradrenaline concentration (dynamic exercise only) and perceived exertion (dynamic exercise only) when compared to control (P < 0.05). No effect of the MAS condition was evident at rest. The MAS condition had no effect on heart rate (HR), plasma lactate and adrenaline concentrations or oxygen uptake at rest and during exercise. The carotid baroreflex stimulus-response curve was reset upward on the response arm and rightward to a higher operating pressure by control exercise without alterations in gain. Activation of the exercise pressor reflex by MAS trousers further reset carotid baroreflex control of MAP, as indicated by the upward and rightward relocation of the curve. However, carotid baroreflex control of HR was only shifted rightward to higher operating pressures by MAS trousers. The sensitivity of the carotid baroreflex was unaltered by exercise pressor reflex activation. 4. These findings suggest that during dynamic and static exercise the exercise pressor reflex is capable of actively resetting carotid baroreflex control of mean arterial pressure; however, it would appear only to modulate carotid baroreflex control of heart rate.

Non-NASA Center↗

Pressor response to intravenous tyramine is a marker of cardiac, but not vascular, adrenergic function

Intravenous injections of the indirect sympathetic amine, tyramine, are used as a test of peripheral adrenergic function. The authors measured the time course of increases in ejection fraction, heart rate, systolic and diastolic pressure, popliteal artery flow, and greater saphenous vein diameter before and after an injection of 4.0 mg/m(2) body surface area of tyramine in normal human subjects. The tyramine caused moderate, significant increases in systolic pressure and significant decreases in total peripheral resistance. The earliest changes were a 30% increase in ejection fraction and a 16% increase in systolic pressure, followed by a 60% increase in popliteal artery flow and a later 11% increase in greater saphenous vein diameter. There were no changes in diastolic pressure or heart rate. These results suggest that pressor responses during tyramine injections are primarily due to an inotropic response that increases cardiac output and pressure and causes a reflex decrease in vascular resistance. Thus, tyramine pressor tests are a measure of cardiac, but not vascular, sympathetic function.

NASA Discipline Cardiopulmonary↗

Toward Transpulmonary Chemoembolization with Degradable Starch Microspheres: Systematic Analysis of Local and Systemic Effects in a Porcine Model

Purpose: To investigate local and systemic effects of transpulmonary chemoembolization (TPCE) with degradable starch microspheres (DSM) and doxorubicin. The long-term goal is to establish DSM-TPCE as a treatment option for pulmonary malignancies. Materials and Methods: Nine pigs underwent TPCE of either the right or left lower lobe pulmonary artery (LLPA) and bland embolization (TPE) of the contralateral LLPA. Before the procedures, macroaggregated albumin (MAA) particles were injected into both LLPAs, to exclude systemic shunting. Pulmonary arterial pressure, heart rate and oxygenation were recorded immediately before and at 1, 3, 5 and 10 min after treatment. To investigate possible nontarget embolization, animals underwent cerebral MRI (cMRI). We killed the animals after a contrast-enhanced chest computed tomography (CT) and performed a pathologic examination at 12 h (3), 24 h (3) and 72 h (3) after treatment. Results: All experiments were technically successful. Mean injected DSM dose until stasis was similar in TPCE and TPE (4.3 ± 1.4 vs. 4.0 ± 1.4 mL). Pulmonary arterial pressure increased significantly 3 min after treatment (TPE: 17 ± 5 vs. 27 ± 7 mmHg; TPCE: 22 ± 6 vs. 36 ± 8 mmHg). No significant changes in heart rate or peripheral oxygenation levels occurred. We observed no evidence of structural lung damage or permanent perfusion disruption on CT. MAA test injection and cMRI revealed no shunting or nontarget embolization. The pathologic assessment revealed nonspecific local inflammation of the lung parenchyma. Conclusion: In this large-animal model, TPCE and TPE appear feasible and safe. We observed a mild increase in pulmonary arterial pressure. Nontarget embolization did not occur. TPCE, as well as TPE, did not cause structural damage to the normal lung parenchyma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An implantable instrument for studying the long-term flight biology of migratory birds

The design of an instrument deployed in a project studying the high altitude Himalayan migrations of bar-headed geese (Anser indicus) is described. The electronics of this archival datalogger measured 22 × 14 × 6.5 mm, weighed 3 g, was powered by a ½AA-sized battery weighing 10 g and housed in a transparent biocompatible tube sealed with titanium electrodes for electrocardiography (ECG). The combined weight of 32 g represented less than 2% of the typical bodyweight of the geese. The primary tasks of the instrument were to continuously record a digitised ECG signal for heart-rate determination and store 12-bit triaxial accelerations sampled at 100 Hz with 15% coverage over each 2 min period. Measurement of atmospheric pressure provided an indication of altitude and rate of ascent or descent during flight. Geomagnetic field readings allowed for latitude estimation. These parameters were logged twice per minute along with body temperature. Data were stored to a memory card of 8 GB capacity. Instruments were implanted in geese captured on Mongolian lakes during the breeding season when the birds are temporarily flightless due to moulting. The goal was to collect data over a ten month period, covering both southward and northward migrations. This imposed extreme constraints on the design's power consumption. Raw ECG can be post-processed to obtain heart-rate, allowing improved rejection of signal interference due to strenuous activity of locomotory muscles during flight. Accelerometry can be used to monitor wing-beat frequency and body kinematics, and since the geese continued to flap their wings continuously even during rather steep descents, act as a proxy for biomechanical power. The instrument enables detailed investigation of the challenges faced by the geese during these arduous migrations which typically involve flying at extreme altitudes through cold, low density air where oxygen availability is significantly reduced compared to sea level.

60 APPLIED LIFE SCIENCES↗

Hemodynamic changes during whole body surface cooling and lower body negative pressure

Six young healthy male subjects were studied to evaluate the use of whole body surface cooling (WBSC) as an antiorthostatic intervention. Previous studies have demonstrated that perfusion of an Apollo cooling garment with 16 C water produced a significant increase in stroke volume and decrease in heart rate at rest and during lower body negative pressure (LBNP). However, optimal perfusion temperatures have not been determined. The present study examined the effects of WBSC using perfusion of water at a temperature of 10 C. This perfusion temperature produced a greater decrease in mean skin temperature than water at 16 C (4 C drop compared to 2 C). The hemodynamic effects were also more prominent with 10 C water as shown by the increase in stroke volume of 11% at rest and of 35% during LBNP at -50 torr compared to control measurements at ambient temperature. Heart rates were lowered significantly (8 beats/min) and systolic arterial blood pressure was higher (8 torr). Cooling with 10 C water produced a slight increase in muscle tone, reflected by a small but significant increase (+84 ml/min) in oxygen uptake. These data suggest that WBSC is an effective nonpharmacologic means of controlling preload and deserves further investigation as an antiorthostatic intervention.

Raven, P. B.↗

Physiological and genomic signatures of evolutionary thermal adaptation in redband trout from extreme climates

Abstract Temperature is a master environmental factor that limits the geographical distribution of species, especially in ectotherms. To address challenges in biodiversity conservation under ongoing climate change, it is essential to characterize relevant functional limitations and adaptive genomic content at population and species levels. Here, we present evidence for adaptive divergence in cardiac function and genomic regions in redband trout ( Oncorhynchus mykiss gairdneri ) populations from desert and montane streams. Cardiac phenotypes of individual fish were measured in the field with a custom‐built electrocardiogram apparatus. Maximum heart rate and its rate limiting temperature during acute warming were significantly higher in fish that have evolved in the extreme of a desert climate compared to a montane climate. Association mapping with 526,301 single nucleotide polymorphisms ( SNP s) across the genome revealed signatures of thermal selection both within and among ecotypes. Among desert and montane populations, 435 SNP s were identified as putative outliers under natural selection and 20 of these loci showed significant association with average summer water temperatures among populations. Phenotypes for cardiac performance were variable within each ecotype, and 207 genomic regions were strongly associated with either maximum heart rate or rate limiting temperatures among individuals. Annotation of significant loci provided candidate genes that underlie thermal adaptation, including pathways associated with cardiac function ( IRX 5, CASQ 1, CAC 1D, and TITIN ), neuroendocrine system ( GPR 17 and NOS ), and stress response ( SERPH ). By integrating comparative physiology and population genomics, results here advance our knowledge on evolutionary processes of thermal adaptation in aquatic ectotherms.

Chen, Zhongqi↗

Functional Task Tests in Partial Gravity During Parabolic Flight

BACKGROUND Understanding how critical mission tasks are performed in partial gravity such as on the moon or Mars is necessary to define effective and comprehensive countermeasure strategies for preserving crew performance during exploration missions. We studied the performance of tasks such as standing, balancing, walking, and jumping during the partial gravity phases of parabolic flight. We hypothesized that the acute effects of partial gravity on vestibular, proprioceptive, and sensorimotor functions would negatively impact performance. METHODS Twelve subjects (6F, 6M; 40.2 ± 8.5 years) were tested over three flights of 30 parabolas each, including 10 parabolas at 0.25g, 10 parabolas at 0.5g, and 10 parabolas at 0.75g. Subjects also performed tests in 1g between parabolas. During the seat egress and walk task, subjects rose from a seated position and walked as quickly as possible straight ahead towards a cone (4 m distance), stepped over a 30 cm high obstacle, walked around the cone making a 180° left turn, returned to the chair, and sat down in the chair. Other tasks included a tandem stance on rails, jump down from a 30cm platform, recovery from fall (prone to stand), and limits of stability tasks. Data were collected using inertial measurement units (Opal V2, APDM, Portland, OR) worn on the head and trunk, heart rate monitors (Polar, Finland), and a force plate (Bertec, Columbus, OH). During the jump down and limits of stability tasks, falls were recorded if subjects took extra steps, lifted their heels/toes, or used their arms to recover balance. RESULTS Gravity level had a significant effect on performance, with the greatest changes from 1g tending to be at the 0.25g level (Table 1). Lower gravity levels were associated with increased times to complete the seat egress and walk task and the recovery from fall task, increased head-trunk coordination, decreased tandem stance rail balance times, decreased change in heart rate during the recovery from fall task, and increased cone of stability distance in the anterior-posterior direction. In addition, there were significantly more falls recorded at the lower gravity levels: 31 falls at 0.25g, 14 falls at 0.5g, 6 falls at 0.75g, and 6 falls at 1g. DISCUSSION These data suggest that there is a dose-response relationship between gravity level and functional task performance. The largest changes in performance were expected at the lowest gravity level (0.25g) because subjects would no longer be able to use the gravitational reference for the perception of upright. Understanding the extent of performance deficits informs the risks and design of countermeasures for exploration spaceflight missions.

T R Macaulay↗

Cardiovascular Deconditioning and Venous Air Embolism in Simulated Microgravity in the Rat

Astronauts conducting extravehicular activities undergo decompression to a lower ambient pressure, potentially resulting in gas bubble formation within the tissues and venous circulation. Additionally, exposure to microgravity produces fluid shifts within the body leading to cardiovascular deconditioning. A lower incidence of decompression illness in actual spaceflight compared with that in ground-based altitude chamber flights suggests that there is a possible interaction between microgravity exposure and decompression illness. The purpose of this study was to evaluate the cardiovascular and pulmonary effects of simulated hypobaric decompression stress using a tail suspension (head-down tilt) model of microgravity to produce the fluid shifts associated with weightlessness in conscious, chronically instrumented rats. Venous bubble formation resulting from altitude decompression illness was simulated by a 3-h intravenous air infusion. Cardiovascular deconditioning was simulated by 96 h of head-down tilt. Heart rate, mean arterial blood pressure, central venous pressure, left ventricular wall thickening and cardiac output were continuously recorded. Lung studies were performed to evaluate edema formation and compliance measurement. Blood and pleural fluid were examined for changes in white cell counts and protein concentration. Our data demonstrated that in tail-suspended rats subjected to venous air infusions, there was a reduction in pulmonary edema formation and less of a decrease in cardiac output than occurred following venous air infusion alone. Mean arterial blood pressure and myocardial wall thickening fractions were unchanged with either tail-suspension or venous air infusion. Heart rate decreased in both conditions while systemic vascular resistance increased. These differences may be due in part to a change or redistribution of pulmonary blood flow or to a diminished cellular response to the microvascular insult of the venous air embolization.

Robinson, R. R.↗

Logistic Risk Model for the Unique Effects of Inherent Aerobic Capacity on (+)G(sub z) Tolerance Before and After Simulated Weightlessness

Small sample size (n less than 1O) and inappropriate analysis of multivariate data have hindered previous attempts to describe which physiologic and demographic variables are most important in determining how long humans can tolerate acceleration. Data from previous centrifuge studies conducted at NASA/Ames Research Center, utilizing a 7-14 d bed rest protocol to simulate weightlessness, were included in the current investigation. After review, data on 25 women and 22 men were available for analysis. Study variables included gender, age, weight, height, percent body fat, resting heart rate, mean arterial pressure, Vo(sub 2)max and plasma volume. Since the dependent variable was time to greyout (failure), two contemporary biostatistical modeling procedures (proportional hazard and logistic discriminant function) were used to estimate risk, given a particular subject's profile. After adjusting for pro-bed-rest tolerance time, none of the profile variables remained in the risk equation for post-bed-rest tolerance greyout. However, prior to bed rest, risk of greyout could be predicted with 91% accuracy. All of the profile variables except weight, MAP, and those related to inherent aerobic capacity (Vo(sub 2)max, percent body fat, resting heart rate) entered the risk equation for pro-bed-rest greyout. A cross-validation using 24 new subjects indicated a very stable model for risk prediction, accurate within 5% of the original equation. The result for the inherent fitness variables is significant in that a consensus as to whether an increased aerobic capacity is beneficial or detrimental has not been satisfactorily established. We conclude that tolerance to +Gz acceleration before and after simulated weightlessness is independent of inherent aerobic fitness.

Ludwig, David A.↗

Miniature Biometric Sensor Project

Heart rate monitoring (HRM) is a critical need during exploration missions. Unlike the four separate systems used on ISS today, the single HRM system should perform as a diagnostic tool, perform well during exercise or high level activity, and be suitable for use during EVA. Currently available HRM technologies are dependent on uninterrupted contact with the skin and are prone to data drop-out and motion artifact when worn in the spacesuit or during exercise. Here, we seek an alternative to the chest strap and electrode based sensors currently in use on ISS today. This project aims to develop a single, high performance, robust biosensor with focused efforts on improved heart rate data quality collection during high intensity activity such as exercise or EVA.

Falker, John↗

Supine exercise during lower body negative pressure effectively simulates upright exercise in normal gravity

Exercise within a lower body negative pressure (LBNP) chamber in supine posture was compared with similar exercise against Earth's gravity (without LBNP) in upright posture in nine healthy male volunteers. We measured footward force with a force plate, pressure in soleus and tibialis anterior muscles of the leg with transducer-tipped catheters, calf volume by strain gauge plethysmography, heart rate, and systolic and diastolic blood pressures during two conditions: 1) exercise in supine posture within an LBNP chamber during 100-mmHg LBNP (exercise-LBNP) and 2) exercise in upright posture against Earth's gravity without LBNP (exercise-1 G). Subjects exercised their ankle joints (dorsi- and plantarflexions) for 5 min during exercise-LBNP and for 5 min during exercise-1 G. Mean footward force produced during exercise-LBNP (743 +/- 37 N) was similar to that produced during exercise-1 G (701 +/- 24 N). Peak contraction pressure in the antigravity soleus muscle during exercise-LBNP (115 +/- 10 mmHg) was also similar to that during exercise-1 G (103 +/- 13 mmHg). Calf volume increased significantly by 3.3 +/- 0.5% during exercise-LBNP compared with baseline values. Calf volume did not increase significantly during exercise-1 G. Heart rate was significantly higher during exercise-LBNP (99 +/- 5 beats/min) than during exercise-1 G (81 +/- 3 beats/min). These results indicate that exercise in supine posture within an LBNP chamber can produce similar musculoskeletal stress in the legs and greater systemic cardiovascular stress than exercise in the upright posture against Earth's gravity.

NASA Center ARC↗

Cyclist exposure to black carbon, ultrafine particles and heavy metals: An experimental study along two commuting routes near Antwerp, Belgium

Highlights: • Wearable UFP and BC instrumentation was carried along whilst cycling 2 different commuting routes. • HR-ICP-MS provided elemental information on railway- and roadside-exposed routes. • Heart rate was tracked simultaneously to estimate the personal inhaled pollutant dose. • The bicycle highway route exhibited 300% lower BC and 20% lower UFP concentrations. • Elemental differences are observed between the considered commuting routes. Urban environments typically exhibit large atmospheric pollution variation, in both space and time. In contrast to traditional monitoring networks suffering from a limited spatial coverage, mobile platforms enable personalized high-resolution monitoring, providing valuable insights into personal atmospheric pollution exposure, and the identification of potential pollution hotspots. This study evaluated personal cyclist exposure to UFPs, BC and heavy metals whilst commuting near Antwerp, Belgium, by performing mobile measurements with wearable black carbon (BC) and ultrafine particle (UFP) instruments. Loaded micro-aethalometer filterstrips were chemically analysed and the inhaled pollutant dose determined from the exhibited heart rate. Considerable spatial pollutant variation was observed along the travelled routes, with distinct contributions from spatial factors (e.g. traffic intersections, urban park and market) and temporary events. On average 300% higher BC, 20% higher UFP and changing elemental concentrations are observed along the road traffic route (RT), when compared to the bicycle highway route (BH). Although the overall background pollution determines a large portion of the experienced personal exposure (in this case 53% for BC and 40% for UFP), cyclists can influence their personal atmospheric pollution exposure, by selecting less exposed commuting routes. Our results, hereby, strengthen the body of evidence in favour of further policy investments in isolated bicycle infrastructure.

54 ENVIRONMENTAL SCIENCES↗