Low power and privacy preserving sensor platform for occupancy detection

A low-cost, low-power, stand-alone sensor platform having a visible-range camera sensor, a thermopile array, a microphone, a motion sensor, and a microprocessor that is configured to perform occupancy detection and counting while preserving the privacy of occupants. The platform is programmed to extract shape/texture from images in spatial domain; motion from video in time domain; and audio features in frequency domain. Embedded binarized neural networks are used for efficient object of interest detection. The platform is also programmed with advanced fusion algorithms for multiple sensor modalities addressing dependent sensor observations. The platform may be deployed for (i) residential use in detecting occupants for autonomously controlling building systems, such as HVAC and lighting systems, to provide energy savings, (ii) security and surveillance, such as to detect loitering and surveil places of interest, (iii) analyzing customer behavior and flows, (iv) identifying high performing stores by retailers.

Velipasalar, Senem↗

Experimentation on Finned-Tube Microchannel Heat Exchanger Incorporating Phase Change Material and R-410A

Integrating latent heat thermal energy storage, particularly phase change materials (PCM), in building heating, ventilation, air conditioning, and refrigeration (HVAC&R) systems, offers substantial benefits for peak load shifting and energy efficiency. While numerous studies explore PCM-embedded heat exchangers (PCM-HX) using single-phase heat transfer fluids, there needs to be more investigation regarding PCM-HX utilizing two-phase refrigerant flow. This gap is even more pronounced for microchannel heat exchanger (MCHX) configurations. In this study, an MCHX-based PCM-HX was built and tested to analyze and evaluate the performance of a PCM-HX operating with a two-phase refrigerant as the working fluid. A commercially available MCHX condenser unit was embedded with 2.6 kg of RT35 PCM and tested using R-410A as the working fluid, using an in-house test loop to control the refrigerant inlet conditions precisely. Thin and minimally invasive T-type thermocouples traced the temperature evolution along MCHX channels and tube banks. Additional larger T-type thermocouple probes at the refrigerant inlet and outlet measured the average power of the PCM-HX during condensing tests, ranging from 0.7 kW to 1.6 kW based on mass flow rates varying from 3.5 g/s to 8 g/s. This experimental study on MCHX-based PCM-HX with a two-phase refrigerant has the potential to offer practical design guidelines for the direct integration of PCM-TES in HVAC&R systems without the use of a secondary loop, while caution is advised to avoid a substantial increase in the refrigerant charge amount.

42 ENGINEERING↗

Development of a near-isothermal transcritical CO 2 compression system with a liquid piston compressor

Compressors are critical components in vapor compression cycle systems, significantly contributing to energy consumption. As global demand for HVAC&R systems rises, enhancing compressor efficiency becomes increasingly vital. This paper introduces a novel liquid piston compressor integrated with a gas cooler for the transcritical CO 2 refrigeration cycle. The liquid piston enables CO 2 refrigerant compression within various types of heat exchangers, facilitating the transfer of compression heat to the heat transfer fluid. By releasing significant heat, this compressor allows for removing or downsizing the traditional gas cooler in the refrigeration system. This paper presents the experimental performance of the first near-isothermal compressor utilizing a liquid piston in a vapor compression cycle. The critical parameters affecting heat transfer are analyzed by using a 1-D simulation model to achieve a near-isothermal compression process. The results show that the developed prototype successfully reduced the compression temperature increase from 95 K to 10 K, achieving 90 % isothermal efficiency. Furthermore, the 1-D simulation results suggest the smaller internal diameter tubes benefit the isothermal efficiency the most.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simulation, Challenge Testing & Validation of Occupancy Recognition & CO 2 Technologies (Final Project Report)

This final report covers the results of the development of testing methods of occupancy sensor systems connected to HVAC controls. This project focused on the development of test methods to evaluate the performance of HVAC-connected occupancy sensor systems, including occupancy presence, occupancy counting, and CO 2 sensor systems in commercial and residential buildings. This included evaluation of the reliability, ease of commissioning, and energy savings potential of these sensor systems. The results of this work help to standardize the methods used to evaluate performance, to enable the ability to compare sensor system performance following the same methods, to understand which sensor systems perform better or worse compared to others. The U.S. building stock’s energy usage can benefit substantially from having building system operations informed by reliable occupancy recognition and CO 2 measurements, however to date, standard methods have not been in place to ensure that sensor systems’ reported performance is uniformly evaluated. The results of this work support the development of a standard or guideline that outlines the developed methods of testing. This project also included the testing of both off-the-shelf and novel SENSOR team-developed low-cost occupancy sensor systems, using the developed methods of testing. The results of this testing helped to inform further development and improvement of new low-cost sensor systems that will benefit from being used in residential and commercial buildings throughout the country.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Innovative approach to counterfeit and noncompliant refrigerant detection: A cost-effective, portable solution

The increasing prevalence of counterfeit and incompatible refrigerants presents significant risks to Heating, Ventilation, Air Conditioning, and Refrigeration (HVAC&R) systems, including compromised equipment performance, safety hazards, and non-compliance. This article details the development of a novel, cost-effective, and portable detection device designed to accurately verify refrigerants. The device utilizes a controlled gas sampling and analysis system within a sealed chamber, ensuring precise measurements while maintaining safety through a purging mechanism. The system features a high-sensitivity sensor integrated with an onboard control module that analyzes gas composition in real-time, providing feedback within a 2-minute duration. Laboratory validation demonstrated the device’s high accuracy (>95 % based on correct identification of compliant vs. non-compliant blends) in detecting unauthorized refrigerant blends. The projected cost of the product stands at ∼ $150, based on the retail pricing of individual components. Laboratory validation demonstrated the device’s high accuracy (>95 % for composition identification, 100 % rejection of tested counterfeit/incorrect blends) in detecting unauthorized refrigerant blends with a response time <2 min. The device correctly identified authentic R-454A/B/C blends and reliably rejected R-407F and closely related counterfeit mixtures. Key advantages include affordability, ease of use, rapid response time, and compatibility with a wide range of refrigerants. This solution supports compliance with regulatory frameworks, enhances safety in HVAC&R operations, and mitigates the risks associated with counterfeit refrigerants.

Counterfeit refrigerants↗

Evaluating Thermostats' Deadbands Using HVAC Hardware-In-the-Loop Experiment for Advanced Control Strategies

Smart thermostats have gained significant popularity due to their potential for optimizing energy consumption and enhanced user control while ensuring occupants' comfort. The deadband, also referred to as temperature differential, is defined as the temperature difference between the desired setpoint and upper threshold or lower threshold for the HVAC equipment to turn on. It is a key factor influencing energy efficiency and user satisfaction. This paper presents a comparative analysis of the deadbands of five different smart thermostats, tested with a heat pump, aiming to identify variations in their deadband settings and implications for energy management. The experimental study was conducted using a HVAC hardware-in-theloop (HIL) system that integrates smart thermostats with physical HVAC equipment in a simulated house environment. The study explores the trade-offs between energy efficiency and occupant comfort and highlights how different thermostats participating in demand response event cycle differently based on their deadband settings. The findings offer valuable insights into how selecting the right thermostat or configuring smart thermostat with appropriate deadband settings can be leveraged to enhance demand response capabilities, shift loads effectively and improve operational flexibility in HVAC systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluating Thermostats' Deadbands Using HVAC Hardware-In-the-Loop Experiment for Advanced Control Strategies: Preprint

Smart thermostats have gained significant popularity due to their potential for optimizing energy consumption and enhanced user control while ensuring occupants' comfort. The deadband, also referred to as temperature differential, is defined as the temperature difference between the desired setpoint and upper threshold or lower threshold for the HVAC equipment to turn on. It is a key factor influencing energy efficiency and user satisfaction. This paper presents a comparative analysis of the deadbands of five different smart thermostats, tested with a heat pump, aiming to identify variations in their deadband settings and implications for energy management. The experimental study was conducted using a HVAC hardware-in-theloop (HIL) system that integrates smart thermostats with physical HVAC equipment in a simulated house environment. The study explores the trade-offs between energy efficiency and occupant comfort and highlights how different thermostats participating in demand response event cycle differently based on their deadband settings. The findings offer valuable insights into how selecting the right thermostat or configuring smart thermostat with appropriate deadband settings can be leveraged to enhance demand response capabilities, shift loads effectively and improve operational flexibility in HVAC systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heat recovery subsystem and overall system integration of fuel cell on-site integrated energy systems

The best HVAC (heating, ventilating and air conditioning) subsystem to interface with the Engelhard fuel cell system for application in commercial buildings was determined. To accomplish this objective, the effects of several system and site specific parameters on the economic feasibility of fuel cell/HVAC systems were investigated. An energy flow diagram of a fuel cell/HVAC system is shown. The fuel cell system provides electricity for an electric water chiller and for domestic electric needs. Supplemental electricity is purchased from the utility if needed. An excess of electricity generated by the fuel cell system can be sold to the utility. The fuel cell system also provides thermal energy which can be used for absorption cooling, space heating and domestic hot water. Thermal storage can be incorporated into the system. Thermal energy is also provided by an auxiliary boiler if needed to supplement the fuel cell system output. Fuel cell/HVAC systems were analyzed with the TRACE computer program.

Mougin, L. J.↗

Assessing the Threat: Weaving Cybersecurity into the Building Development Process

Today’s connected lighting systems have the potential to reduce energy consumption and operational costs via the use of the data they collect and share with other building systems (e.g., HVAC, building automation, security). However, many market available products are new to being networked, and when networked components in lighting and other building systems are not sufficiently secured, they present opportunities for criminals to exploit. Further, security vulnerabilities in one system can be used as lateral steppingstones that allow access to other prized assets on the same network. These cybersecurity concerns could deter the adoption and use of connected systems, which then could jeopardize long-term national objectives for reduced energy usage. The workflows described here and presented in more detail in the referenced reports are examples of how these frameworks and tools can be put to practical use during system design and specification.

attack surface, Building development, threat analy↗

Dataset of low global warming potential refrigerant refrigeration system for fault detection and diagnostics

Abstract HVAC and refrigeration system fault detection and diagnostics (FDD) has attracted extensive studies for decades; however, FDD of supermarket refrigeration systems has not gained significant attention. Supermarkets consume around 50 kWh/ft 2 of electricity annually. The biggest consumer of energy in a supermarket is its refrigeration system, which accounts for 40%–60% of its total electricity usage and is equivalent to about 2%–3% of the total energy consumed by commercial buildings in the United States. Also, the supermarket refrigeration system is one of the biggest consumers of refrigerants. Reducing refrigerant usage or using environmentally friendly alternatives can result in significant climate benefits. A challenge is the lack of publicly available data sets to benchmark the system performance and record the faulted performance. This paper identifies common faults of supermarket refrigeration systems and conducts an experimental study to collect the faulted performance data and analyze these faults. This work provides a foundation for future research on the development of FDD methods and field automated FDD implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fault Diagnosis in HVAC Chillers

Modern buildings are being equipped with increasingly sophisticated power and control systems with substantial capabilities for monitoring and controlling the amenities. Operational problems associated with heating, ventilation, and air-conditioning (HVAC) systems plague many commercial buildings, often the result of degraded equipment, failed sensors, improper installation, poor maintenance, and improperly implemented controls. Most existing HVAC fault-diagnostic schemes are based on analytical models and knowledge bases. These schemes are adequate for generic systems. However, real-world systems significantly differ from the generic ones and necessitate modifications of the models and/or customization of the standard knowledge bases, which can be labor intensive. Data-driven techniques for fault detection and isolation (FDI) have a close relationship with pattern recognition, wherein one seeks to categorize the input-output data into normal or faulty classes. Owing to the simplicity and adaptability, customization of a data-driven FDI approach does not require in-depth knowledge of the HVAC system. It enables the building system operators to improve energy efficiency and maintain the desired comfort level at a reduced cost. In this article, we consider a data-driven approach for FDI of chillers in HVAC systems. To diagnose the faults of interest in the chiller, we employ multiway dynamic principal component analysis (MPCA), multiway partial least squares (MPLS), and support vector machines (SVMs). The simulation of a chiller under various fault conditions is conducted using a standard chiller simulator from the American Society of Heating, Refrigerating, and Air-conditioning Engineers (ASHRAE). We validated our FDI scheme using experimental data obtained from different types of chiller faults.

Choi, Kihoon↗

Fuel driven near isothermal compressor

A gas compressor system includes a compression liquid holding tank in fluid communication with a combustion tank. A combustible fluid is directed to the combustion tank. An ignition system is provided for igniting the combustible fluid. A compression liquid flows between the liquid holding tank, the combustion tank, and a compression tank. A compressible gas is provided in the compression tank. The ignition of the combustible fluid drives the compression liquid from the combustion tank to the compression tank, compressing the compressible liquid. An HVAC&R system and a method of compressing gas are also disclosed.

Momen, Ayyoub Mehdizadeh↗

A new control score concept for building performance assessment

In buildings, performance assessment often focuses on energy use with metrics such as energy use intensity (EUI) used to benchmark performance. However, energy performance of a building is fundamentally determined by the control system that engages the energy-using systems. There are two aspects of control that are of particular importance: (1) the ability to regulate process variables to their setpoints; and (2) whether the setpoints are at the right levels and/or following desired profiles. Most buildings do not reach their energy efficiency potential due to deficiencies in control performance and operators do not have access to metrics that can illuminate these deficiencies. Here this paper addresses this problem by providing novel techniques that combine these two aspects of control performance into a single standardized score on the scale of 0-10. The concept of a standardized control scores enables all systems in a building to be compared on the same scale and also for scores to be rolled up to different levels in the building and system hierarchy for system-wide analysis. The paper presents the theory for the method, describes a prototype tool for displaying scores, and presents results from application to a large building in Minneapolis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗