Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HVAC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Raising the Bar in High Performance Laboratory Design

Laboratory facilities are expensive to build and operate, they consume energy at high rates compared to other types of buildings, and modifications are frequently required to accommodate ever-changing research activities. PNNL sought ways to address these issues in the design and construction of a 14,700 sq. ft. new laboratory building. To improve adaptability to change a high roof structure was used that allows raising the ceiling when needed with minimal disruption to installed HVAC and electrical utilities. Also, HVAC equipment was located on a mezzanine above the central corridor rather than above ceilings. This eliminates the need for maintenance personnel to routinely access lab spaces, reducing disruption to research staff and improving maintenance access. To improve the reliability of operations while reducing energy consumption, heat pipe heat recovery with evaporative cooling, zoned heating/cooling coils, high-efficiency condensing boilers, district cooling, VAV fume hoods, DDC controls, energy use monitoring, and implementation of the US Department of Energy’s Guiding Principles for Federal Leadership in Sustainable Buildings were all used. The energy model developed during design projected energy use at 2,840 MBtu/yr, a 13.5% savings over ASHRAE Standard 90.1-2010. The first full year of operation resulted in actual energy use of 2,661 MBtu, a savings of 19% over Standard 90.1. As a result of the project design’s demonstrated success, these strategies will be incorporated into a significantly larger (125,000 sq ft), $65 million lab facility to be constructed on the PNNL campus in 2020.

Scott, Jeffery M.↗

Data Analysis Approach for Large Data Volumes in a Connected Community

Recent advancements within smart neighborhoods where utilities are enabling automatic control of appliances such as heating, ventilation, and air conditioning (HVAC) and water heater (WH) systems are providing new opportunities to minimize energy costs through reduced peak load. This requires systematic collection, storage, management, and in-memory processing of large volumes of streaming data for fast performance. In this paper, we propose a multi-tier layered IoT software framework that enables effective descriptive and predictive data analysis for understanding live operation of the neighborhood, fault identification, and future opportunities for further optimization of load curves. We then demonstrate how we achieve live situational awareness of the connected neighborhood through a suite of visualization components. Finally, we discuss a few analytic dashboards that address questions such as peak load reductions obtained due to optimization, customer preference for automatic control of appliances (do they override the automatic control of HVAC?, etc.). 1 1 This manuscript has been authored by UT-Battelle, LLC under Contract No. DE-AC05-00OR22725 with the U.S. Department of Energy. The United States Government retains and the publisher, by accepting the article for publication, acknowledges that the United States Government retains a nonexclusive, paid-up, irrevocable, world-wide license to publish or reproduce the published form of this manuscript, or allow others to do so, for United States Government purposes. The Department of Energy will provide public access to these results of federally sponsored research in accordance with the DOE Public Access Plan (http://energy.gov/downloads/doe-public-access-plan).

Chinthavali, Supriya↗

Model based co-simulation platform for integrated building system control and design optimization

Both steady-state and dynamic simulations have been widely used by HVAC&R industry to support product/equipment development for decades. Steady-state simulation focuses on the system mass, energy and momentum balance of an equilibrium state. It is based on high-fidelity components models, and thus is suitable for system and component design optimization. Dynamic simulation studies the system transient response and is generally used for controls development and verification. It usually does not require rigorous component models of high accuracy because 1) the commonly used PID control is feedback control whose control performance evaluation doesn’t require high fidelity system/plant model; 2) high-fidelity dynamic model significantly increases the number of equations and variables and creates tremendous challenge for math solver. For supervisory control, transactive control or optimization of an integrated building system, the HVAC&R equipment is often one of the sub-components to be controlled. High-fidelity equipment models are required for accurately evaluating control strategies. In addition, building equipment manufacturers have developed a lot of high-fidelity steady-state equipment/component models per their expertise. Thus, a platform that can integrate OEM high-fidelity steady-state model with dynamic building simulation and/or electric power system & grid simulation to support the development and verification of supervisory control for integrated building systems is necessary. In this study, ORNL’s heat pump design tool (HPDM) is utilized to develop a co-simulation platform for supervisory control and optimization in integrated building systems. It is based on a model that integrates high-fidelity steady-state simulation equipment models with dynamic building simulation. A practical case of using the proposed co-simulation platform to develop and evaluate the supervisory control and optimization is presented and discussed.

Sun, Jian↗

Fusion-based occupancy sensing for building systems

Sensing and control apparatus for a building HVAC system includes interior and boundary sensors, such as cameras and thermal sensors, generating sensor signals conveying occupancy-related features for an area. A controller uses the sensor signals to produce an occupancy estimate and to generate equipment-control signals to cause the HVAC system to supply conditioned air to the area based on the occupancy estimate. The controller includes fusion systems collectively generating the occupancy estimate by corresponding fusion calculations, the fusion systems producing a boundary occupancy-count change based on sensor signals from the boundary sensors, an interior occupancy count based on sensor signals from the interior sensors, and the overall occupancy estimate. Fusion may be of one or multiple types including cross-modality fusion across different sensor types, within-modality fusion across different instances of same-type sensors, and cross-algorithm fusion using different algorithms for the same sensor(s).

Konrad, Janusz L.↗

An Energy Calculator for Simple Commercial Buildings

According to the EIA, simple commercial buildings account for 97% of total commercial building stock. However, most simple commercial buildings for example small- to mid-sized offices, retail, schools and warehouses do not benefit from the data-driven decision-making capabilities of whole-building energy modeling. The high cost of custom modeling limits the use of energy modeling of simple buildings for new construction or retrofit measures. Lack of tools providing helpful information on interactive savings estimates creates difficulties in meeting aggressive decarbonization and energy efficiency goals for simple building designers and utility program managers. This paper reviews a beta phase Simple Building Calculator with the ability to generate relatively accurate and interactive modeling results based on a limited but robust set of inputs. It can evaluate whole-building or single measure savings in new or existing buildings, compare measure package choices, or provide simplified performance modeling for energy codes and utility incentives. The tool combines physical (annual whole building prototype simulation) and statistical modeling techniques to predict annual energy performance. It supports a variety of building characteristics for envelope, HVAC, and lighting with parameters ranging from vintage to max tech configurations, as well as support for single-zone and simple multi-zone HVAC systems. The Simple Building Calculator was designed to provide immediate feedback for otherwise computationally intensive tasks like measure comparison, development of multiple measure package combinations, or verification that measures meet efficiency targets—all with the goal of providing a tool for quick annual energy simulation of simple commercial buildings.

Hart, Reid↗

Long-term trends in connected thermostat performance

Internet-connected thermostats (CTs) control heating and cooling systems in about 30% of North American homes, and capture half of annual thermostat sales. In 2017 the U.S. Environmental Protection Agency created a program to certify the performance of ENERGY STAR® Connected Thermostats. To demonstrate compliance with energy-saving criteria, thermostat vendors must submit performance summaries for a representative sample of up to 1250 homes. Vendors must then re-submit results from a new, representative sample every six months in order to maintain their ENERGY STAR certification. This procedure has created a unique record of each thermostat’s long-term performance in response to changes in weather, customer demographics, building stock, and algorithms. Our analysis covers submissions from 13 different vendors, who submitted data up to 7 times over four years. We found that these semi-annual samples generated relatively stable trends for comfort temperatures and Heating, Ventilating and Air Conditioning (HVAC) runtimes over the study period. However, some vendors achieved consistently more energy-conserving comfort temperatures and shorter HVAC runtimes than others. The most recent submission runtimes averaged 700 hours for heating and 1,300 hours for cooling, but some vendors achieved runtimes as much as 17% below the mean. This implies lower energy consumption is due in large part to more successful algorithms and control strategies used by those vendors.

Meier, Alan↗

A Universal Refrigerant Charge Fault Detection and Diagnostics Method Based on Pump Down Operation

The performance of the heat pump system varies greatly depending on the refrigerant charge amount. Improving the refrigerant charge fault detection and diagnostics (FDD) method of vapor compression systems have the potential for increasing energy efficiency and reducing service cost. Previous studies to predict refrigerant charge amount are mostly empirical methods which require significant amount of experimental data for high accuracy. The primary goal of this research is to develop a universal charge fault detection method which requires only a few experimental data with high prediction accuracy.Currently, pump down operations are typical practices by HVAC technicians when they need to open the refrigerant circuit to make a repairment. In addition, compressors have a built-in low-pressure cut-off protection function, and the compressor performance maps are commonly available from manufacturers. The proposed method innovatively utilizes the typical pump down operation, the compressor low-pressure cut-off protection, and the compressor performance map. It does not require any geometry information of heat exchangers, refrigerant lines, or charge buffers.The new charge prediction method is firstly formulated through theoretical analysis, then verified and calibrated by a quasi-steady-state simulation of the pump down process for a residential heat pump system. The quasi steady-state simulation uses an HVAC system simulation framework driven by DOE/ORNL Heat Pump Design Model (HPDM). Preliminary experiment validations with heat pump refrigerant leakage tests demonstrate the deviation of the proposed charge prediction method compared with measurement is within 8%. This technology makes refrigerant charge amount available at the technician’s fingertips and leads to shorter maintenance time and fewer site visits.

Li, Zhenning↗

The Demonstration of Power over Ethernet (PoE) Technologies in Commercial and Institutional Buildings

PoE technologies are currently ubiquitous in offices in the form of phones, access points, and IP security cameras and managed by on-site IT staff. As low voltage DC-power capabilities have increased with network switches, PoE devices are now being integrated across additional building systems, including lighting, computers, and HVAC controls. Since PoE devices are connected to network switches, energy monitoring and management can be performed through the IT network management software. Data and results from technology validations are still very limited for PoE equipment. This lack of information hinders higher adoption as its benefits and challenges have been insufficiently quantified in real-world scenarios. The use of IT network switches to power and control lighting, plug loads, and HVAC were demonstrated at a variety of sites including offices, schools, and a hotel. This paper presents the findings of a three-year DOE-/State of Minnesota-funded project that demonstrated and assessed the energy and non-energy benefits of Power over Ethernet (PoE) technologies at four commercial/institutional sites. The goals of the demonstrations were to: (1) assess the receptiveness of commercial and institutional markets to these new technologies, (2) demonstrate the feasibility of PoE technologies within standard design/construction practices and commercial codes, (3) assess the energy and cost savings opportunities of these technologies, (4) provide energy management opportunities where they typically are not available, and (5) formulate approaches to spur adoption of these technologies in the marketplace.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Demonstration of Power over Ethernet (PoE) Technologies in Commercial and Institutional Buildings

PoE technologies are currently ubiquitous in offices in the form of phones, access points, and IP security cameras and managed by on-site IT staff. As low voltage DC-power capabilities have increased with network switches, PoE devices are now being integrated across additional building systems, including lighting, computers, and HVAC controls. Since PoE devices are connected to network switches, energy monitoring and management can be performed through the IT network management software. Data and results from technology validations are still very limited for PoE equipment. This lack of information hinders higher adoption as its benefits and challenges have been insufficiently quantified in real-world scenarios. The use of IT network switches to power and control lighting, plug loads, and HVAC were demonstrated at a variety of sites including offices, schools, and a hotel. This paper presents the findings of a three-year DOE-/State of Minnesota-funded project that demonstrated and assessed the energy and non-energy benefits of Power over Ethernet (PoE) technologies at four commercial/institutional sites. The goals of the demonstrations were to: (1) assess the receptiveness of commercial and institutional markets to these new technologies, (2) demonstrate the feasibility of PoE technologies within standard design/construction practices and commercial codes, (3) assess the energy and cost savings opportunities of these technologies, (4) provide energy management opportunities where they typically are not available, and (5) formulate approaches to spur adoption of these technologies in the marketplace.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Results from Laboratory and Field Study of Thin Triple Pane Windows

Heat transfer through windows accounts for a significant percentage of a building’s energy use and adds substantially to the peak cooling load of a home. In recent years, improvements in glass manufacturing have enabled the use of a very thin central pane of glass similar to a cell phone screen to produce a thin triple-pane window, for finished insulated glass units (IGUs) with an overall thickness similar to standard double-pane windows. Because this highly insulating “thin triple” glass product can be incorporated into almost any existing window frame and can be fabricated at a modest added cost, the U.S. Department of Energy sponsored laboratory and field demonstration testing of thin triple-pane windows to validate thermal performance and installation requirements in real-life field settings. Thin triple pane windows were evaluated at the PNNL Lab Homes, a matched pair of manufactured houses located on PNNL’s campus in Richland, Washington and also at 16 different field study sites around the country. The experimental results include a comparison of heating, ventilation, and air-conditioning (HVAC) energy usage, condensation potential, occupant comfort, sound infiltration, and thermal performance. Field study data will be gathered through June of 2022; preliminary results are being shared in this paper. The lab houses are identical except that the reference house had standard double pane windows with assembly U-0.66 and the test house had thin triple pane windows with assembly U-0.19. Across the experimental test days, the daily HVAC savings ranged from 0.2 to 18.7 kWh (3%–18%) for the heating season and from 2.5 to 8.0 kWh (23%–41%) for the cooling season. The higher thermal performance of the thin triple-pane windows also reduced the condensation potential on the interior surface during winter months and provided more even distribution of temperatures throughout the home in comparison to the baseline. In addition to the added thermal performance, the thin triple-pane windows demonstrated significant acoustic benefits, reducing sound infiltration by 8 dB to 10 dB. For the field test portion of the project thin triple pane insulated glass units were produced by two different manufacturers, and then installed without modification into the ½” IGU pockets of the standard double pane frames of four other manufacturers. Field tests performed on existing homes in Washington, Montana, Colorado, and New York compared thin triple pane retrofits to original window conditions (before and after). Field tests at new construction sites in Minnesota, Michigan, and New York compared thin triple pane windows to commercially available solutions such as double pane or traditional triple pane (with a standard-thickness center pane). Field test work is ongoing, but preliminary results appear to follow the sound, surface temperature, and energy improvement results from the Lab Homes comparison. Additionally, reports from builders and installers indicate that thin triples require almost no added time or effort to install and look nearly identical to other windows, indicating the possibility of offering next-level performance with a product that requires very little modification to current production or installation practices, long considered a major barrier to technology uptake in the construction market.

energy efficiency, home retrofit, Windows, window ↗

Building Automation

In this chapter, we focus on both need-based and vision-based control innovation for building automation for HVAC systems. After providing a brief background that describes different HVAC architectures and products, we describe the control challenges and opportunities from a needs-based point of view, at the equipment level, the systems level, and the building level. At the equipment level, increased use of continuously variable actuation such as variable speed compressors and fans, requires application of robust multivariable control that must consider various types of nonlinear behavior across increasingly larger operating envelopes. The objective at this level is to achieve robust and energy efficient operation. At the system level, coupled and interactive dynamics among subsystems are increasingly important to consider, and functional integration of these subsystems, along with set points and operating schedules are designed to minimize energy consumption and improve occupant comfort. At the building level, issues such as integration among other building systems, such as the building envelope and the electric grid, offer opportunities to develop new types of demand response and grid-interactive behaviors and technologies. At the higher levels, system dynamics and robust stability are less of an issue, similar to process control applications, while optimization and integration are more important, although dynamic stability is increasing an issue at the higher levels too. From a vision-driven innovation point of view, we describe three areas that will require sustained research efforts and will eventually impact building automation: Digital Twins, Model Predictive Control, and Grid Interactive Buildings.

Bortoff, Scott↗

Learning-Based Building Flexibility Estimation and Control to Improve Microgrid Economics and Resilience: Preprint

This paper proposes a learning-based building flexibility estimation and control framework to improve system economics and resilience. A data-driven building load flexibility model consisting of weather forecasting and estimating load consumption is proposed to quantify building heating, ventilation, and air conditioning (HVAC) load flexibility. A reinforcement learning-based microgrid controller is proposed to dispatch distributed generators, distributed energy resources, and build HVAC loads while taking flexibility information as one of the inputs. Simulation analysis is conducted on the model of a real microgrid in California. The effectiveness of the proposed learning-based building flexibility estimation and control in reducing microgrid energy costs and improving the sustainability of critical loads is demonstrated.

building load flexibility↗

Practical challenges of model predictive control (MPC) for grid interactive small and medium commercial buildings

To the urgent call for mitigating climate change, substantial initiatives have been undertaken to deploy grid-interactive heating, ventilation, and air-conditioning (HVAC) controls, such as model predictive control (MPC) for buildings. These efforts typically aim to curtail peak energy demand, shift load and enhance overall energy efficiency. With the recent development of low-cost MPC technologies that don’t require extensive instrumentation or manual modeling, small and medium commercial buildings (SMCBs), which rarely utilize advanced HVAC control systems, have become candidates for grid-interactive efficient buildings (GEBs). However, despite the potential benefits and maturity of the technology itself, several practical challenges remain in real-world implementation. In this paper, we share the practical challenges that we have encountered in implementing and testing three types of MPC solutions (ON/OFF unit, dualfuel, and VRF systems) on multiple SMCB sites. We describe the MPC deployment process and discuss the lessons learned. The site selection, eligibility, and retrofit availability (e.g., utility price structure, thermostat communications, etc.) are the main discussion points at the beginning of the project. Also, the modeling automation and the best practices for interacting with endusers and handling erroneous situations are presented for successful operations.

woo Ham, Sang↗

Brick Schema Standardized Plug Load Control Strategies for Load Reduction: Preprint

Plug loads comprise a significant percentage of commercial building energy consumption. Applying intelligent controls to turn off plug loads when unused can provide dynamic load reduction and flexibility, which are key traits of grid-interactive efficient buildings. This capability is important for equitable decarbonization as it can enable disadvantaged communities to electrify buildings without costly upgrades to electrical infrastructure. In this work, we present the effectiveness of various control strategies along with the operational lessons that informed their design. During a three-year period, we operated over 600 smart outlets in 12 university office buildings. The attached plug loads consisted primarily of printers, TVs, water dispensers, and copiers. After recording baseline power measurements for one year, we designed plug load control (PLC) strategies for each plug load type, use, and for different risk tolerance levels because PLC can potentially be disruptive to daily work. We used the Brick Schema to facilitate the management of plug load locations and other metadata. For advanced controls, we integrated the smart plugs with heating, ventilation, and air conditioning (HVAC) systems through the campus building automation system. We found static schedules to be the least disruptive and most predictable for occupants, resulting in 38% and 66% energy savings in two studies. For printers, print server-triggered PLC produced 86% savings, the highest of all strategies with minimal occupant impact. Scheduling of water dispensers and digital signage TVs produced 49% and 70% savings respectively with opportunities to improve performance with the use of HVAC occupancy data.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Experimentation on Finned-Tube Microchannel Heat Exchanger Incorporating Phase Change Material and R-410A

Integrating latent heat thermal energy storage, particularly phase change materials (PCM), in building heating, ventilation, air conditioning, and refrigeration (HVAC&R) systems, offers substantial benefits for peak load shifting and energy efficiency. While numerous studies explore PCM-embedded heat exchangers (PCM-HX) using single-phase heat transfer fluids, there needs to be more investigation regarding PCM-HX utilizing two-phase refrigerant flow. This gap is even more pronounced for microchannel heat exchanger (MCHX) configurations. In this study, an MCHX-based PCM-HX was built and tested to analyze and evaluate the performance of a PCM-HX operating with a two-phase refrigerant as the working fluid. A commercially available MCHX condenser unit was embedded with 2.6 kg of RT35 PCM and tested using R-410A as the working fluid, using an in-house test loop to control the refrigerant inlet conditions precisely. Thin and minimally invasive T-type thermocouples traced the temperature evolution along MCHX channels and tube banks. Additional larger T-type thermocouple probes at the refrigerant inlet and outlet measured the average power of the PCM-HX during condensing tests, ranging from 0.7 kW to 1.6 kW based on mass flow rates varying from 3.5 g/s to 8 g/s. This experimental study on MCHX-based PCM-HX with a two-phase refrigerant has the potential to offer practical design guidelines for the direct integration of PCM-TES in HVAC&R systems without the use of a secondary loop, while caution is advised to avoid a substantial increase in the refrigerant charge amount.

42 ENGINEERING↗

Pushing the Envelope-Moving Dynamic Building Envelope Thermal Energy Storage Systems Mainstream: Preprint

Buildings contribute to nearly 40% of the U.S. national energy consumption and a significant portion of CO2 emissions. More importantly, disadvantaged communities are disproportionately affected by energy burden and thermal discomfort in their homes. This paper will discuss two novel DOE's BTO supported thermal energy storage (TES) integrated dynamic building envelope technologies, their ability to harvest ambient energy, and improve energy efficiency by reducing HVAC loads and peak electricity demand while enhancing energy and thermal resilience in buildings. The paper will also discuss the recent advancements that have made these systems more affordable and easier to integrate into new and existing buildings. The first solution is a thermally anisotropic building envelope (TABE) system that can redirect ambient thermal energy (heat or coolness) from diurnal outdoor conditions, solar irradiance, and night sky radiation from the envelope to a hydronic loop. The redirected thermal energy can be stored in a TABE-integrated thermal energy storage system and use the stored energy to offset HVAC energy use and peak demand. The second solution is an innovative plug-and-play thermal switch in the form of insertable plugs integrated with a phase change material (PCM). The plug can vary its thermal resistance based on the indoor and outdoor conditions, thus allowing preferential directional heat flow, and enhancing utilization of free ambient cooling and heating to charge/discharge the PCM, much like a solid-state economizer. While the fist solution can be actively controlled, the second solution is passive, requiring no external power, and work solely based on the ambient temperature.

anisotropic envelope↗

Pushing the Envelope—Moving Dynamic Building Envelope Thermal Energy Storage Systems Mainstream

Buildings contribute to nearly 40% of the U.S. national energy consumption and a significant portion of CO2 emissions. More importantly, disadvantaged communities are disproportionately affected by energy burden and thermal discomfort in their homes. This paper will discuss two novel DOE's BTO supported thermal energy storage (TES) integrated dynamic building envelope technologies, their ability to harvest ambient energy, and improve energy efficiency by reducing HVAC loads and peak electricity demand while enhancing energy and thermal resilience in buildings. The paper will also discuss the recent advancements that have made these systems more affordable and easier to integrate into new and existing buildings. The first solution is a thermally anisotropic building envelope (TABE) system that can redirect ambient thermal energy (heat or coolness) from diurnal outdoor conditions, solar irradiance, and night sky radiation from the envelope to a hydronic loop. The redirected thermal energy can be stored in a TABE-integrated thermal energy storage system and use the stored energy to offset HVAC energy use and peak demand. The second solution is an innovative plug-and-play thermal switch in the form of insertable plugs integrated with a phase change material (PCM). The plug can vary its thermal resistance based on the indoor and outdoor conditions, thus allowing preferential directional heat flow, and enhancing utilization of free ambient cooling and heating to charge/discharge the PCM, much like a solid-state economizer. While the fist solution can be actively controlled, the second solution is passive, requiring no external power, and work solely based on the ambient temperature.

Shrestha, Som↗

Estimating Flexibility Envelopes for Residential Customers From Utility Smart Meter Data: Preprint

Demand response from residential customers has significant potential to support power system operations, but accurate flexibility estimation is challenging due to the limited resolution of advanced metering infrastructure (AMI) data. Most utility AMI measurements are recorded at hourly intervals, with only a small portion at higher resolutions, and even fewer households have appliance-level energy usage data. To address this issue, this paper proposes a two-stage long short-term memory (LSTM) framework for estimating household flexibility envelopes from low-resolution AMI data. In the first stage, the heating, ventilating, and air-conditioning (HVAC) load and non-HVAC loads are estimated by using a model trained on a small set of households with appliance-level profiles. These estimated data are then used to compute the upper- and lower-flexibility bounds, which are subsequently down-sampled to lower-resolution data. In the second stage, these flexibility bounds serve as training inputs for another LSTM model, enabling direct prediction of flexibility envelopes for households with only hourly AMI data. This method is validated using Pecan Street data from two different areas, and the results demonstrate its applicability and effectiveness.

24 POWER TRANSMISSION AND DISTRIBUTION↗