Development of microstructure and irradiation hardening of Zircaloy during low dose neutron irradiation at nominally 358 C

Wrought Zircaloy-2 and Zircaloy-4 were neutron irradiated at nominally 358 C in the high flux isotope reactor (HFIR) at relatively low neutron fluences between 5.8 1022 and 2.9 1025 n/m2 (E > 1 MeV). The irradiation hardening and change in microstructure were characterized following irradiation using tensile testing and examinations of microstructure using Analytical Electron Microscopy (AEM). Small increments of dose (0.0058, 0.11, 0.55, 1.08, and 2.93 1025 n/m2) were used in the range where the saturation of irradiation hardening is typically observed so that the role of microstructure evolution and hai loop formation on irradiation hardening could be correlated. An incubation dose between 5.8 1023 and 1.1 1024 n/m2 was needed for loop nucleation to occur that resulted in irradiation hardening. Increases in yield strength were consistent with previous results in this temperature regime, and as expected less irradiation hardening and lower hai loop number density values than those generally reported in literature for irradiations at 260 326 C were observed. Unlike previous lower temperature data, there is evidence in this study that the irradiation hardening can decrease with dose over certain ranges of fluence. Irradiation induced voids were observed in very low numbers in the Zircaloy-2 materials at the highest fluence.

Cockeram, Brian V↗

Determination of neutron irradiation temperatures of SiC using electrical resistivity method

The irradiation temperature of silicon carbide (SiC) was determined post-irradiation by examination of the recovery of the electrical resistivity due to thermal annealing in a rapid heating/cooling optical furnace. High-purity, high-resistivity grade SiC is routinely used as a passive temperature monitor in neutron irradiation studies at the High Flux Isotope Reactor (HFIR), and this paper presents an alternative automated technique for determination of the irradiation temperature the SiC experienced. Neutron collisions with the atoms results in displaced lattice atoms (interstitials) that act as electron donors yielding a significant decrease in electrical resistivity. The irradiation defects become thermodynamically unstable and start to recombine, when annealed above the irradiation temperature, resulting in a recovery of the electrical resistivity. The resistivity is measured at a fixed elevated temperature above ambient, which is below the target irradiation temperature. When the resistivity is plotted as a function of annealing temperatures, a clear increase is observed due to the recovery of irradiation defects. We have demonstrated that this electrical resistivity measurement of SiC is effective to determine irradiation temperature of SiC. In conclusion, energy levels of various defects in SiC were calculated from Arrhenius plots of electrical conductivity versus inverse temperature.

36 MATERIALS SCIENCE↗

Tensile properties of powder-metallurgical-processed tungsten alloys after neutron irradiation near recrystallization temperatures

The tensile properties of powder-metallurgical-processed Pure W, K-doped W, W-3%Re, and K-doped W-3%Re were examined after neutron irradiation up to 0.7 dpa at 910–1020 °C with a thermal neutron shield in the High Flux Isotope Reactor (HFIR). After irradiation, recrystallized Pure W (R) exhibited a brittle fracture mode, while recrystallized K-doped W-3%Re (R) exhibited a ductile fracture mode at 500 °C. K-doped W-3%Re (R) has fine grains, and hence, contains a considerable number of grain boundaries that act as sinks for irradiation defects. Solid solute Re in the W matrix could improve not only the mechanical properties of W, but also its resistance to neutron irradiation. At 500 °C, the ductility of K-doped W-3%Re after irradiation was significantly higher than that of Pure W. The irradiation at ~1000 °C did not induce hardening of stress-relieved (SR) W materials, but SR W materials tended to exhibit a decrease in the ultimate tensile strength (UTS) and an increase in total elongation (TE). Here, the softening due to the recovery and recrystallization of SR W materials and the hardening due to the formation of irradiation defect clusters were balanced during irradiation at ~1000 °C, and ductility was exhibited without an increase in strength.

36 MATERIALS SCIENCE↗

Thermal diffusivity of irradiated tungsten and tungsten-rhenium alloys

The Japan-US PHENIX project irradiated tungsten materials in the RB-19J capsule experiment in the High Flux Isotope Reactor (HFIR). A gadolinium (Gd) shielding was used to absorb the thermal neutrons and reduce rhenium and osmium generation in tungsten. Pure tungsten and K-doped W-3% Re samples were irradiated at 532 – 662 °C to dose of 0.21-0.46 dpa, with the grain orientation perpendicular or parallel to the disk surface. Thermal diffusivity measurements were performed from 100 °C to 500 °C. Furthermore, additional measurements followed after annealing up to 900 °C. Irradiated pure tungsten specimens showed similar thermal diffusivity results compared with an unirradiated W-1% Re specimen in another study. The transmutation amount of Re was calculated to be about 0.52% for those specimens that showed good agreement with this study. Specimens irradiated in this study to different doses presented almost the same thermal diffusivity. Annealing up to 800 °C resulted in no recovery of thermal diffusivity. These results show that the contribution of crystalline defects to degradation of thermal diffusivity is quite limited. In addition, the thermal diffusivity of the irradiated specimens was getting close to that of the unirradiated specimens at elevated temperature.

36 MATERIALS SCIENCE↗

Segregation behavior and phase instability of Eurofer97 after neutron irradiation to 72 dpa

Here, a reduced activation ferritic/martensitic steel, Eurofer97, was neutron irradiated in the vicinity of 300 °C in the High Flux Isotope Reactor (HFIR) up to 72 dpa. Advanced analytical scanning transmission electron microscopy and conventional transmission electron microscopy were applied to investigate the radiation-induced segregation and phase instability behavior after neutron irradiation. Amorphization was observed in M 23 C 6 carbides. Cr-rich clusters were seen within the matrix, near the lath boundaries and close to the M 23 C 6 carbides. Cr enrichment and Fe depletion were detected at both prior austenite grain boundaries and lath boundaries, despite different segregation magnitude. In addition, the enrichment of Ni, the depletion of V, and tiny cavities (presumably helium bubbles) are also found at lath boundaries. This work interrogates the evolution of microstructures after neutron irradiation, which provides detailed understanding on the microstructural aspects controlling the mechanical integrity of Eurofer97 under high-dose neutron damage.

36 MATERIALS SCIENCE↗

Mechanical behavior of additively manufactured and wrought 316L stainless steels before and after neutron irradiation

Fabrication of nuclear reactor components using additive manufacturing (AM) methods is now a practical option since the AM technologies have advanced to allow for building of complex parts with high quality materials. To assess the mechanical performance of printed components in reactor-relevant conditions and to build a property database for the AM 316L stainless steel (SS), mechanical testing and characterization were performed before and after neutron irradiation. In this work, miniature tensile specimens were irradiated at the High Flux Isotope Reactor (HFIR) to 0.2 and 2 displacements per atom (dpa) at 300 and 600°C. The AM 316L SS was tested in the as-built, stress-relieved, and solution-annealed conditions, and the wrought (WT) 316L SS in solution-annealed condition as a reference alloy. The baseline test result showed that the AM 316L SS, regardless of the post-build heat treatment, had higher strength than the WT 316L SS, but similar ductility. Post-irradiation tensile testing was conducted at RT, 300°C, and 500°C for selected irradiation conditions. Neutron irradiation induced significant changes in the mechanical behavior of the AM stainless steels, including both hardening and softening. Although the as-built 316L steel after 300°C irradiation showed necking just after yielding, the overall property changes of the as-printed alloy became less significant after 600°C irradiation. Irradiation-induced ductilization was also observed after the higher temperature irradiation. In general, the strength change was smaller in the relatively stronger as-built and stress-relieved AM SSs than in the solution-annealed AM and WT SSs. These relatively lower strength 316L SSs overall retained higher ductility in the irradiation conditions tested, but the stronger 316L SSs demonstrated a similar level of ductility after the higher temperature (600°C) irradiation. It is a positive assessment for the AM 316L materials that no embrittlement was observed within the test and irradiation conditions of the experiment.

36 MATERIALS SCIENCE↗

Understanding the effect of specimen size on the properties of fine-grain isotropic nuclear graphite for irradiation studies: Mechanical properties

Programs at Oak Ridge National Laboratory are investigating the effects of neutron irradiation in the High Flux Isotope Reactor (HFIR) on properties of fine-grain isotropic nuclear graphites. Specimens were irradiated in the HFIR flux trap, which requires using specimens that are smaller than the sizes recommended by ASTM standards. Here, this work has investigated whether subsized specimens can be used to reliably predict strength behavior. The results show that (1) tensile strength was loosely coupled to specimen volume, (2) the compression specimens had a slightly higher strength for larger volumes, (3) the uniaxial flexural strength was nearly independent of specimen effective area for one orientation whereas the other orientation showed a slight strength–size scaling Weibull behavior, and (4) equibiaxial flexural strength followed traditional strength–size scaling Weibull behavior. These results suggest that fine-grain graphite is more similar to ceramics than to medium- and large-grained graphite with respect to both the strength-limiting flaws (Griffith theory) and the effect of machining on the strength behavior. This work shows that using specimens that are smaller than ASTM recommendations are suitable for investigating the strength changes caused by neutron irradiation because the primary interest is the relative change in the strength distribution parameters rather than their absolute values.

36 MATERIALS SCIENCE↗

Understanding the effect of specimen size on the properties of fine-grain isotropic nuclear graphite for irradiation studies: Physical, electrical, thermal properties

Programs at Oak Ridge National Laboratory are investigating the effects of neutron irradiation in the High Flux Isotope Reactor (HFIR) on properties of fine-grain nuclear graphites. Specimens were irradiated in the HFIR flux trap, which required using specimens that are smaller than the sizes recommended by ASTM standards. Here, this work has investigated whether subsized specimens can be used to reliably determine the measured physical (density, elastic moduli, and electrical resistivity) and thermal properties (coefficient of thermal conductivity and thermal conductivity). The results show the specimen sizes in this investigation had a minimal influence on any of the measured properties. Even for the properties where size influenced the measured value (density and thermal conductivity), an explanation is provided, and the consequences can be accounted for in post-irradiation results. This work demonstrated that using subsized specimens for physical and thermal property measurements is suitable when necessary for fine-grain isotropic graphite.

36 MATERIALS SCIENCE↗

Irradiation creep measurement and microstructural analysis of chromium nitride–coated zirconium alloy using pressurized tubes

Environmental barrier coatings for Zr-based materials are currently under development to reduce oxidation and embrittlement in light-water reactors. Chromium nitride is one such candidate for this application, particularly as accident-tolerant fuel cladding. However, quantifying the impact of coatings on the irradiation-induced creep of zircaloy (Zry) is critical as this mechanism often exceeds thermal creep rates under light-water reactor operating conditions and can be a limiting design characteristic. Additionally, examining irradiation effects in the microstructure at the coating interface is key to understanding the compatibility of the material system. Here, to accelerate the experimental measurement of irradiation creep and microstructure evolution in CrN-Zry, compact, pressurized creep tubes were fabricated and irradiated in the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory. Miniature, thin-walled rodlets fabricated from annealed Zr-Sn barstock were coated with CrN using physical vapor deposition (PVD) to nominal thicknesses of 4 and 8 μm. Coated and uncoated rodlet specimens were internally pressurized and welded, generating nominal circumferential hoop stresses of 0, 90, or 180 MPa under 300°C irradiation conditions. Twelve specimens were measured diametrically prior to irradiation using a low-cost, automated, contactless laser profilometer developed for this work. Specimens were irradiated in sealed capsules for one 25-day HFIR cycle, accumulating approximately 1.8 $\times$ 10 21 n/cm 2 fast fluence (E n > 10 MeV). The irradiated samples were retrieved and remeasured using the same profilometry system in a shielded hot cell facility. Irradiation creep between specimens was compared using standard statistical tests and showed that both thicknesses of CrN coating had a negligible effect on the irradiation creep strain of the Zry material. Microstructure characterization of pre- and post-irradiated CrN-Zry specimens showed minimal changes due to irradiation but did show a substantial O-rich region at the Zry-CrN interface.

36 MATERIALS SCIENCE↗

High-temperature steam oxidation study of irradiated FeCrAl defueled specimens

Post irradiation examinations (PIE) were performed on irradiated iron-chromium-aluminum (FeCrAl) specimens. These FeCrAl specimens were fabricated at the US Department of Energy's Oak Ridge National Laboratory (ORNL). The experimental setup involved subjecting FeCrAl cladding, along with UO 2 pellets, to irradiation in the Idaho National Laboratory Advanced Test Reactor (ATR). In parallel, the FeCrAl alloy tubing without UO 2 pellets was irradiated at ORNL's High Flux Isotope Reactor (HFIR). After irradiation, the ATR-irradiated rodlet was transported to an ORNL hot cell, where it was sectioned into multiple samples for the PIE and severe-accident testing. The sectioning process revealed that the fuel was not bonded to the cladding and could be easily detached from sectioned cladding slices. Microstructural analysis of the fuel cross sections demonstrated no significant interaction between the fuel and the cladding. Additionally, high-temperature steam oxidation tests on defueled cladding segments showed minimal oxygen uptake even at 1200 °C. Here, the ATR-irradiated specimens began to exhibit signs of enhanced oxidation upon reaching a temperature of 1300 °C. Furthermore, enhanced oxidation was observed on the inner surface of the ATR-irradiated FeCrAl specimen, which had been subjected to 1300 °C for a duration of 1 min. By contrast, high-temperature steam oxidation experiments indicated that the HFIR-irradiated FeCrAl cladding provided good thermal stability when exposed to 1300 °C for up to 4 h. Comparative analysis encompassing the oxidation behavior of the ATR-irradiated fueled FeCrAl, HFIR-irradiated unfueled FeCrAl, and unirradiated FeCrAl suggests that the fuel–cladding interaction, although not visible via standard microscale electron microscopy measurements, may accelerate the deterioration of FeCrAl cladding in beyond-design-basis accident scenarios.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Identifying high-impact and high-uncertainty parameters in MiniFuel model predictions

The MiniFuel irradiation platform at Oak Ridge National Laboratory's High Flux Isotope Reactor (HFIR) is a flexible, high-throughput separate effects test capability. Finite element thermal models are relied upon to design MiniFuel experiments and to achieve experimental objectives. Recent reports show good agreement in the model prediction of target fuel temperatures, but as the capability of the experiments is extended to higher temperatures, the uncertainty in the model predictions must be quantified. To that end, high-impact, high-uncertainty parameters that contribute the most uncertainty to the model are identified. The uncertainty quantification was accomplished through a series of screening and sensitivity analyses. The first analysis utilizes the method of Morris to perform a computationally efficient preliminary screening that considers uncertainty in a large number of the model inputs. The most important parameters identified in the Morris screening study were then considered in a Sobol sensitivity analysis that more robustly ranks and quantifies the uncertainty associated with each parameter. From these analyses, it was determined that thermal contact conductance between components is the parameter that contributes the highest uncertainty. The estimated uncertainty of the MiniFuel model fuel temperature predictions is ±80 °C in the removable beryllium and ±40 °C in the vertical experiment facilities. In conclusion, the framework established by the series of sensitivity analyses presented herein could easily be adapted to fit the needs of accelerated fuel qualification processes.

Fuel, Irradiation↗

Defect formation and transmutation behaviors in irradiated tungsten under thermal-neutron shielded and mixed spectrum conditions

Here, this study investigates the microstructural evolution of pure tungsten irradiated under thermal-neutron shielded and mixed spectrum conditions in the High Flux Isotope Reactor (HFIR). Four samples were irradiated at temperatures from 570 °C to 1130 °C up to 0.73 dpa. Neutron spectrum significantly influenced the accumulation of transmutation products, with Re+Os content estimated at ∼0.3–0.6% under thermal-neutron shielded conditions and ∼5.2% under the mixed spectrum condition. Irradiation temperature strongly influences tungsten’s microstructure, with dislocation loops and fine voids forming at lower temperatures and only larger voids and Re/Os segregation observed at higher temperature. Under thermal-neutron shielded conditions, dislocation loops and voids were observed at 570 °C and 790 °C. At the highest irradiation temperature (1130 °C), dislocation loops were no longer observed, while larger but less dense voids remained. Re and Os segregation to void surfaces was evident at 790 °C and 1130 °C, though no precipitation was observed. In contrast, under the mixed-spectrum condition, both spherical and needle-like Re/Os-rich precipitates were observed, frequently accompanied by large voids. Dislocation loops were not observed, but loop-like contrast within the precipitates suggests they may have nucleated on pre-existing loops. Irradiation-induced hardening was assessed for the shielded samples at 570 °C and 790 °C. Dispersed barrier hardening (DBH) analysis, based on TEM-resolved defects, revealed that voids were the dominant contributors to hardening, consistent with literature results. A schematic model is proposed to describe defect and precipitate evolution in tungsten under fusion-relevant transmutation-to-dpa conditions.

Dislocation loops↗

Accelerated radiation tolerance testing of Ti-based MAX phases

MAX phases have recently attracted significant attention for potential nuclear applications due to their novel properties such as unique hexagonal-compact nanolayered crystal structure, high-machinability due to lower hardness levels compared to conventional ceramics, and high-chemical inertness. In order for MAX phases to be used in nuclear reactors, two aspects deserve detailed investigations: (i) their phase stability at high-temperatures and (ii) microstructural defect formation and recovery induced by energetic particle irradiation. To date, degradation mechanisms of MAX phases at high-temperatures and following irradiation are largely unexplored fields of research. This work focuses on the evaluation of two Ti-based MAX phases – Ti 2 AlC and Ti 3 SiC 2 – within the context of extreme environments. To accomplish this, a one-of-a-kind comparison between neutron irradiations, performed over a decade of research at the High Flux Isotope Reactor (HFIR), and heavy-ion irradiations, carried out in situ in a Transmission Electron Microscope (TEM) at the MIAMI-2 facility, has been conducted. The results show Ti-based MAX phases are prone to accelerated decomposition under the conditions investigated. This questions the hypothesis that MAX phases exhibit high phase stability, especially when used in future nuclear energy systems where energetic particle irradiation is a dominating degradation mechanism.

36 MATERIALS SCIENCE↗

Water Calibration Measurements for Neutron Radiography: Application to Water Content Quantification in Porous Media

Using neutron radiography, the measurement of water thickness was performed using aluminum (Al) water calibration cells at the High Flux Isotope Reactor (HFIR) Cold-Guide (CG) 1D neutron imaging facility at Oak Ridge National Laboratory, Oak Ridge, TN, USA. Calibration of water thickness is an important step to accurately measure water contents in samples of interest. Neutron attenuation by water does not vary linearly with thickness mainly due to beam hardening and scattering effects. Transmission measurements for known water thicknesses in water calibration cells allow proper correction of the underestimation of water content due to these effects. As anticipated, strong scattering effects were observed for water thicknesses greater than 2 mm when the water calibration cells were positioned close to the face of the detector / scintillator (0 and 2.4 cm away, respectively). The water calibration cells were also positioned 24 cm away from the detector face. These measurements resulted in less scattering and this position (designated as the sample position) was used for the subsequent experimental determination of the neutron attenuation coefficient for water. Neutron radiographic images of moist Flint sand in rectangular and cylindrical containers acquired at the sample position were used to demonstrate the applicability of the water calibration. Cumulative changes in the water volumes within the sand columns during monotonic drainage determined by neutron radiography were compared with those recorded by direct reading from a burette connected to a hanging water column. In general, the neutron radiography data showed very good agreement with those obtained volumetrically using the hanging water-column method. These results allow extension of the calibration equation to the quantification of unknown water contents within other samples of porous media.

Kang, Misun↗

Neutron tomography of particulate filters: A non-destructive investigation tool for applied and industrial research

This research describes the development and implementation of high-fidelity neutron imaging and the associated analysis of the images. This advanced capability allows the non-destructive, non-invasive imaging of particulate filters (PFs) and how the deposition of particulate and catalytic washcoat occurs within the filter. The majority of the efforts described here were performed at the High Flux Isotope Reactor (HFIR) CG-1D neutron imaging beamline at Oak Ridge National Laboratory; the current spatial resolution is approximately 50 μm. The sample holder is equipped with a high-precision rotation stage that allows 3D imaging (i.e., computed tomography) of the sample when combined with computerized reconstruction tools. What enables the neutron-based image is the ability of some elements to absorb or scatter neutrons where other elements allow the neutron to pass through them with negligible interaction. Of particular interest in this study is the scattering of neutrons by hydrogen-containing molecules, such as hydrocarbons (HCs) and/or water, which are adsorbed to the surface of soot, ash and catalytic washcoat. Even so, the interactions with this adsorbed water/HC is low and computational techniques were required to enhance the contrast, primarily a modified simultaneous iterative reconstruction technique (SIRT). Lastly, this effort describes the following systems: particulate randomly distributed in a PF, ash deposition in PFs, a catalyzed washcoat layer in a PF, and three particulate loadings in a SiC PF.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A prototype system for dynamically polarized neutron protein crystallography

The sensitivity of Neutron Macromolecular Crystallography to the presence of hydrogen makes it a powerful tool to complement X-ray crystallographic studies using protein crystals. The power of this technique is currently limited by the relative low neutron flux provided by even the most powerful neutron sources. The strong polarization dependence of the neutron scattering cross section of hydrogen will allow us to use Dynamic Nuclear Polarization to dramatically improve the signal to noise ratio of neutron diffraction data, delivering order of magnitude gains in performance, and enabling measurements of radically smaller crystals of larger protein systems than are possible today. Here, we present a prototype frozen spin system, built at Oak Ridge National Laboratory to polarize single protein crystals on the IMAGINE beamline at the High Flux Isotope Reactor (HFIR). Details of the design and construction will be described, as will the performance of the system offline and during preliminary tests at HFIR.