Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Functional priors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Solid Rocket Booster Large Main and Drogue Parachute Reliability Analysis

The parachutes on the Space Transportation System (STS) Solid Rocket Booster (SRB) are the means for decelerating the SRB and allowing it to impact the water at a nominal vertical velocity of 75 feet per second. Each SRB has one pilot, one drogue, and three main parachutes. About four minutes after SRB separation, the SRB nose cap is jettisoned, deploying the pilot parachute. The pilot chute then deploys the drogue parachute. The drogue chute provides initial deceleration and proper SRB orientation prior to frustum separation. At frustum separation, the drogue pulls the frustum from the SRB and allows the main parachutes that are mounted in the frustum to unpack and inflate. These chutes are retrieved, inspected, cleaned, repaired as needed, and returned to the flight inventory and reused. Over the course of the Shuttle Program, several improvements have been introduced to the SRB main parachutes. A major change was the replacement of the small (115 ft. diameter) main parachutes with the larger (136 ft. diameter) main parachutes. Other modifications were made to the main parachutes, main parachute support structure, and SRB frustum to eliminate failure mechanisms, improve damage tolerance, and improve deployment and inflation characteristics. This reliability analysis is limited to the examination of the SRB Large Main Parachute (LMP) and drogue parachute failure history to assess the reliability of these chutes. From the inventory analysis, 68 Large Main Parachutes were used in 651 deployments, and 7 chute failures occurred in the 651 deployments. Logistic regression was used to analyze the LMP failure history, and it showed that reliability growth has occurred over the period of use resulting in a current chute reliability of R = .9983. This result was then used to determine the reliability of the 3 LMPs on the SRB, when all must function. There are 29 drogue parachutes that were used in 244 deployments, and no in-flight failures have occurred. Since there are no observed drogue chute failures, Jeffreys Prior was used to calculate a reliability of R =.998. Based on these results, it is concluded that the LMP and drogue parachutes on the Shuttle SRB are suited to their mission and changes made over their life have improved the reliability of the parachute.

Clifford, Courtenay B.↗

Treatment of hypertension with perindopril reduces plasma atrial natriuretic peptide levels, left ventricular mass, and improves echocardiographic parameters of diastolic function

BACKGROUND: Hypertension is a major independent risk factor for cardiac deaths, and diastolic dysfunction is a usual finding during the course of this disease. HYPOTHESIS: This study was designed to investigate the effects of chronic therapy with perindopril on left ventricular (LV) mass, left atrial size, diastolic function, and plasma level of atrial natriuretic peptide (ANP) in patients with hypertension. METHODS: Twenty four patients who had not been previously taking any antihypertensive medication and without prior history of angina pectoris, myocardial infarction, congestive heart failure, dysrhythmias, valvular heart disease, or systemic illnesses received 4-8 mg/day of perindopril orally. Echocardiographic studies were acquired at baseline and 6 months after the initiation of therapy. RESULTS: Systolic and diastolic blood pressure decreased from 174 +/- 19.7 and 107.5 +/- 7.8 mmHg to 134 +/- 10.6 and 82 +/- 6.7 mmHg, respectively (p < 0.001). Left ventricular mass decreased from 252.4 +/- 8.3 to 205.7 +/- 7.08 g and left atrial volume from 20.4 +/- 5.1 to 17.6 +/- 5.2 ml, respectively (p < 0.001). Transmitral Doppler early and atrial filling velocity ratio (E/A) increased from 0.69 +/- 0.06 to 0.92 +/- 0.05 m/s and plasma ANP level decreased from 71.9 +/- 11.7 to 35.3 +/- 7.8 pg/ml (p < 0.001). Reduction of LV mass correlated positively with a reduction in ANP levels (r = 0.66, p < 0.0005). CONCLUSIONS: Perindopril caused a significant reduction of LV mass, left atrial volume, and plasma ANP levels, as well as improvement in Doppler parameters of LV filling in this group of patients with hypertension.

NASA Program Biomedical Research and Countermeasur↗

GALEX Study of the UV Variability of Nearby Galaxies and a Deep Probe of the UV Luminosity Function

The proposal has two aims - a deep exposure of NGC 300, about a factor of 10 deeper than the GALEX all-sky survey; and an examination of the UV variability. The data were received just prior to a series of proposal deadlines in early spring. A subsequent analysis delay includes a move from SAO to the University of Texas - San Antonio. Nevertheless, we have merged the data into a single deep exposure as well as undertaking a preliminary examination of the variability. No UV halo is present as detected in the GALEX observation of M83. No UV bursts are visible; however a more stringent limit will only be obtained through a differencing of the sub-images. Papers: we expect 2 papers at about 12 pages/paper to flow from this project. The first paper will report on the time variability while the second will focus on the deep UV image obtained from stacking the individual observations.

Schlegel, Eric↗

Binary chromatographic data and estimation of adsorbent porosities

Data for the system n-pentane/n-heptane on porous Chromosorb-102 adsorbent were obtained at 150, 175, and 200 C for mixtures containing zero to 100% n-pentane by weight. Prior results showing limitations on superposition of pure component data to predict multicomponent chromatograms were verified. The thermodynamic parameter MR0 was found to be a linear function of sample composition. A nonporous adsorbent failed to separate the system because of large input sample dispersions. A proposed automated data processing scheme involving magnetic tape recording of the detector signals and processing by a minicomputer was rejected because of resolution limitations of the available a/d converters. Preliminary data on porosity and pore size distributions of the adsorbents were obtained.

Meisch, A. J.↗

Long-term influence of physical aging processes in epoxy matrix composites

Selected mechanical properties of (plus or minus 45 degree sub 4s) graphite/epoxy composites were found to be affected by sub T sub g annealing. Postcured specimens of Thornel 300 graphite/Narmco 5208 epoxy were sub T sub G annealed at 413 K (140 C) for ca. 10 to the first through 10 to the fifth powers min., with a prior quenching from above T sub g. The ultimate tensile strength, strain-to-break, and toughness of the composite were found to decrease as a function of sub T sub g annealing time. The time-dependent change in properties can be explained on the basis of physical aging which is related to free volume changes in the non-equilibrium glassy state of network epoxies. The results imply possible changes in composite properties with service time.

Kong, E. S. W.↗

Sub-T/g/ annealing studies of advanced epoxy-matrix graphite-fiber-reinforced composites

Annealing at temperatures below the glass transition temperature (sub-T/g/ annealing) in structural epoxy network glasses is found to affect long-term mechanical properties of symmetrically (+ or - 45 deg) reinforced 16-lamina graphite/epoxy composites. Post-cured specimens of Thornel 300 graphite/Narmco 5208 epoxy are sub-T(g) annealed at 140 C for about 10, 100, 1000, 10,000, and 100,000 min with a prior quenching above T(g). The ultimate tensile strength, strain-to-break, and static toughness of the composite materials are found to decrease as a function of sub-T(g) annealing time, while no weight loss is observed. Time-dependent changes in properties are explained by a physical aging concept based on free-volume decreases in the nonequilibrium glassy state of network epoxies, and results imply that changes in composite properties may occur with the service time.

Kong, E. S. W.↗

Unsteady environments and responses of the shuttle combined loads orbiter test

Both separate and combined wind tunnel and vibration shaker tests were conducted on two structural panels representative of the Shuttle orbiter in the NASA LaRC 8-foot transonic pressure tunnel (TPT) to determine the effects of combined loads on the thermal protection system (TPS). The primary objective of this test was to provide a combined full-scale load environment and realistic time history of the dynamic pressures, Mach numbers (through transonic), and dynamic structural responses of these panels. The panels were selected from orbiter locations where interactive load sources such as aerodynamic shock waves, turbulent boundary layers, strut-induced vorticity, and substrate deformation combined to provide high bonding loads between the TPS and the orbiter structure. The test panels for this program were highly instrumented with static and dynamic pressure gages, accelerometers, deflectometers, strain gages, Schileren and high-speed photography, and special instrumentation necessary to determine TPS/structure interface loads and tile motions. Two test specimens of each orbiter panel were utilized. Both were high-fidelity representations of the selected orbiter location. The first panel (calibration panel) for each test was utilized to calibrate the tunnel and shaker system as well as provide a data-gathering source for applied static and dynamic loads. The second panel (test panel) for each test was subjected to flight time exposures only so that TPS characteristics as a function of flight mission exposure could be determined. These tests were the last in a series that was suce6ssfully completed and necessary to certify the TPS prior to the first launching of the Shuttle.

P. H. Schuetz↗

Flight guidance research for recovery from microburst wind shear

Research is in progress to develop flight strategy concepts for avoidance and recovery from microburst wind shears. The objectives of this study are to evaluate the performance of various strategies for recovery from wind shear encountered during the approach-to-landing, examine the associated piloting factors, and evaluate the payoff of forward-look sensing. Both batch and piloted simulations are utilized. The industry-recommended manual recovery technique is used as a baseline strategy. Two advanced strategies were selected for the piloted tests. The first strategy emulates the recovery characteristics shown by prior optimal trajectory analysis, by initially tracking the glideslope, then commanding a shallow climb. The second strategy generates a flight path angle schedule that is a function of airplane energy state and the instantaneous shear strength. All three strategies are tested with reactive sensing only and with forward-look sensing. Piloted simulation tests are in progress. Tentative results indicate that, using only reactive alerts, there appears to be little difference in performance between the various strategies. With forward-look alerts, the advanced guidance strategies appear to have advantages over the baseline strategy. Relatively short forward-look alert times, on the order of 10 or 15 seconds, produce a far greater recovery benefit than optimizing a recovery from a reactive alert.

Hinton, David A.↗

Examination of a vortex-ring interaction phenomenon in an axisymmetric flow

Unsteady separated flow in an axisymmetric configuration is investigated, with the objective of analyzing vortex-ring formation and break-up and the ensuing interactions believed to be leading to breakdown of laminar flow. The model problem considered is an idealized representation of a combustor with a centerbody. Direct solution of the time-dependent incompressible Navier-Stokes equations is employed, with central-differencing for all spatial derivatives, to determine the response of this flow for Re = 2000, 5000 and 10,000. The last case revealed a rather novel unsteady vortex-ring interaction phenomenon. This case has been further investigated using third-order accurate upwind differencing for the convective terms. The flow is interrogated carefully by examining the corresponding instantaneous vorticity, stream-function and velocity fields, as well as by tracking mass-less marker particles in some of the critical regions. Such detailed examination is deemed essential, prior to assigning fundamental physical relevance to the observed vortex-interaction phenomenon.

Ghia, U.↗

Illness/injury pattern complex 40 (Titan)

On July 31, 1991, EG&G Medical began providing medical support at the Titan Area Clinic (TAC). The hours of operation are 0700-2300, Monday through Friday, with Emergency Medical Services (EMS) provided 24-hours a day, seven days a week. The TAC consists of a 10 x 10 ft section of a trailer that also houses Bechtel Safety. Supplies consisted of an examining table, an eye wash chair, first aid equipment, over-the-counter medications, spine boards, a portable rescuscitator, etc. All of the nurses are Advanced Cardiac Life Support (ACLS) certified. Although the Titan Area Clinic is strictly a first-aid station with no ACLS facilities on-site, it is staffed with an Occupational Health Nurse with ACLS certification. If ACLS or additional help is needed, the nurse activates EMS by dialing 911. The nurse responds to any medical problems or emergencies on the complex, but activates EMS prior to leaving the TAC. A Bechtel Safety Representative accompanies the nurse to the site and assists as needed. Other aspects of the complex and its functions are presented.

Blasdell, Sharon↗

Application of Modern Design of Experiments to CARS Thermometry in a Model Scramjet Engine

We have applied formal experiment design and analysis to optimize the measurement of temperature in a supersonic combustor at NASA Langley Research Center. We used the coherent anti-Stokes Raman spectroscopy (CARS) technique to map the temperature distribution in the flowfield downstream of an 1160 K, Mach 2 freestream into which supersonic hydrogen fuel is injected at an angle of 30 degrees. CARS thermometry is inherently a single-point measurement technique; it was used to map thc flow by translating the measurement volume through the flowfield. The method known as "Modern Design of Experiments" (MDOE) was used to estimate the data volume required, design the test matrix, perform the experiment and analyze the resulting data. MDOE allowed us to match the volume of data acquired to the precision requirements of the customer. Furthermore, one aspect of MDOE, known as response surface methodology, allowed us to develop precise maps of the flowfield temperature, allowing interpolation between measurement points. An analytic function in two spatial variables was fit to the data from a single measurement plane. Fitting with a Cosine Series Bivariate Function allowed the mean temperature to be mapped with 95% confidence interval half-widths of +/- 30 Kelvin, comfortably meeting the confidence of +/- 50 Kelvin specified prior to performing the experiments. We estimate that applying MDOE to the present experiment saved a factor of 5 in data volume acquired, compared to experiments executed in the traditional manner. Furthermore, the precision requirements could have been met with less than half the data acquired.

Danehy, P. M.↗

Thermal Performance of Low Layer Density Multilayer Insu1ation Using Liquid Nitrogen

In order to support long duration cryogenic propellant storage, the Cryogenic Fluid Management (CFM) Project of the Exploration Technology Development Program (ETDP) is investigating the long duration storage propertie$ of liquid methane on the lunar surface. The Methane Lunar Surface Thermal Control (MLSTC) testing is using a tank of the approximate dimensions of the Altair ascent tanks inside of a vacuum chamber to simulate the environment in low earth orbit and on the lunar surface. The thermal performance testing of multilayer insulation (MLI) coupons that are fabricated identically to the tank applied insulation is necessary to understand the performance of the blankets and to be able to predict the performance of the insulation prior to testing. This coupon testing was completed in Cryostat-100 at the Cryogenics Test Laboratory. The results showed the properties of the insulation as a function of layer density, number of layers, and warm boundary temperature. These results aid in the understanding of the performance parameters o fMLI and help to complete the body of literature on the topic.

Johnson, Wesley L.↗

Discrete Wavelength-Locked External Cavity Laser

A prototype improved external cavity laser (ECL) was demonstrated in the second phase of a continuing effort to develop wavelength-agile lasers for fiber-optic communications and trace-gas-sensing applications. This laser is designed to offer next-generation performance for incorporation into fiber-optic networks. By eliminating several optical components and simplifying others used in prior designs, the design of this laser reduces costs, making lasers of this type very competitive in a price-sensitive market. Diode lasers have become enabling devices for fiber optic networks because of their cost, compactness, and spectral properties. ECLs built around diode laser gain elements further enhance capabilities by virtue of their excellent spectral properties with significantly increased (relative to prior lasers) wavelength tuning ranges. It is essential to exploit the increased spectral coverage of ECLs while simultaneously insuring that they operate only at precisely defined communication channels (wavelengths). Heretofore, this requirement has typically been satisfied through incorporation of add-in optical components that lock the ECL output wavelengths to these specific channels. Such add-in components contribute substantially to the costs of ECL lasers to be used as sources for optical communication networks. Furthermore, the optical alignment of these components, needed to attain the required wavelength precision, is a non-trivial task and can contribute substantially to production costs. The design of the present improved ECL differs significantly from the designs of prior ECLs. The present design relies on inherent features of components already included within an ECL, with slight modifications so that these components perform their normal functions while simultaneously effecting locking to the required discrete wavelengths. Hence, add-in optical components and the associated cost of alignment can be eliminated. The figure shows the locking feedback signal, and the frequency locking achieved by use of this signal, as a mirror is tilted through a range of angles to tune the ECL through 48 channels. The data for the frequency plot were obtained, simultaneously with the data for the locking-signal plot, by using a scanning Michelson interferometer to precisely determine the ECL wavelength (and, hence, frequency). Given the ability of the Michelson interferometer to obtain highly precise readings, the frequency plot can be taken to be a reliable indication of single-mode operation. The discontinuities in the frequency plot signify the switching of the ECL between channels; in other words, they indicate tuning with locking to discrete frequencies. The peaks of the feedbacklocking signal correspond to the centers, or near centers, of the mirror angle scan through the corresponding channels. Thus, it is clear that when the feedback-locking signal is at a local maximum, the ECL is operating at single frequency at or near the middle frequency of the selected channel. This is all that is required for precisely locking the ECL output wavelength. The locking is achieved without additional external optical components.

Pilgrim, Jeffrey S.↗

A Proposed Study Examining Individual Differences in Temporal Profiles of Cardiovascular Responses to Head Down Tilt During Fluid Loading

Susceptibility of healthy astronauts to orthostatic hypotension and presyncope is exacerbated upon return from spaceflight. The effect of altered gravity during space flight and planetary transition on human cardiovascular function is of critical importance to maintenance of astronaut health and safety. Hypovolemia, reduced plasma volume, is suspected to play an important role in cardiovascular deconditioning following exposure to spaceflight, which may lead to increased peripheral resistance, attenuated arterial baroreflex, and changes in cardiac function. A promising countermeasure for post-flight orthostatic intolerance is fluid loading used to restore lost plasma volume by giving crew salt tablets and water prior to re-entry. The main purpose of the proposed study is to define the temporal profile of cardiac responses to simulated 0-G conditions before and following a fluid loading countermeasure. 8 men and 8 women will be tested during 4 hour exposures at 6o head down tilt (HDT). Each subject will be given two exposures to HDT on separate days, one with and one without fluid loading (one liter of 0.9% saline solution). Stand tests (orthostatic stress) will be done before and after each HDT. Cardiac measures will be obtained with both impedance cardiography and echo ultrasound

Cowings, Patricia↗

Daytime Cognitive Performance in Response to Sunlight or Fluorescent Light Controlling for Sleep Duration

Light is the primary synchronizer of the human circadian rhythm and also has acute alerting effects. Our study involves and comparing the alertness, performance and sleep of participants in the NASA Ames Sustainability Base, which uses sunlight as its primary light source, to in a traditional office building which uses overhead florescent lighting and varying exposure to natural light. The purpose of this study is to determine whether the use of natural lighting as a primary light source improves daytime cognitive function and promotes nighttime sleep. Participants from the Sustainability Base will be matched by gender and age to individuals working in other NASA buildings. In a prior study we found no differences in performance between those working in the Sustainability Base and those working in other buildings. Unexpectedly, we found that the average sleep duration among participants in both buildings was short, which likely obscured our ability to detect a difference the effect of light exposure on alertness. Given that such sleep deprivation has negative effects on cognitive performance, in this iteration of the study we are asking the participants to maintain a regular schedule with eight hours in bed each night in order to control for the effect of self-selected sleep restriction. Over the course of one week, we will ask the participants to wear actiwatches continuously, complete a psychomotor vigilance task (PVT) and digit symbol substitution task (DSST) three times per day, and keep daily sleepwork diaries. We hope that this study will provide data to support the idea that natural lighting and green architectural design are optimal to enhance healthy nighttime sleep patterns and daytime cognitive performance.

cognitive performance↗

Characterizing Response Versus Scan-Angle for MODIS Reflective Solar Bands Using Deep Convective Clouds

MODIS consists of a cross-track, two-sided scan mirror, whose reflectance is not uniform but is a function of angle of incidence (AOI). This feature, known as response versusscan-angle (RVS), was characterized for all reflective solar bands of both MODIS instruments prior to launch. The RVS characteristic has changed on orbit, which must be tracked precisely over time to ensure the quality of MODIS products. The MODIS characterization support team utilizes the onboard calibrators and the earth view responses from multiple pseudo invariant desert sites to track the RVS changes at different AOIs. The drawback of using deserts is the assumption that these sites are radiometrically stable during the monitoring period. In addition, the 16-day orbit repeat cycle of MODIS allows for only a limited set of AOIs over a given desert. We propose a novel and robust approach of characterizing the MODIS RVS using tropical deep convective clouds (DCC). The method tracks the monthly DCC response at specified sets of AOIs to compute the temporal RVS changes. Initial results have shown that the Aqua-MODIS collection 6 band 1 level 1B radiances show considerable residual RVS dependencies, with long-term drifts up to 2.3 at certain AOIs.

Clouds↗

Ultrahigh Areal Capacity Holey Graphene Air Cathodes for Li-O2 and Li-CO2 Batteries

Advanced lithium (Li) batteries using gaseous cathode reactants such as oxygen (O2) and carbon dioxide (CO2)are attractive energy storage platforms because the gases are obtained externally and thus not accounted for in the total battery weight when fully charged.The discharge products at the cathode, typically Li2O2 for Li-O2 batteries and Li2CO3 for Li-CO2 batteries, are insoluble in the electrolyte.Therefore, in order for such batteries to function properly, an “air cathode”,which is a conductive scaffold within the battery cell,is required as a physical location for cathode electrochemical reactions to occur. Prior research has identified many carbon nanomaterials such as carbon nanotubes and graphene as viable choices for air cathode scaffold, while various metallic and metal-free catalytic systems integrated onto carbon-based air cathodes have been developed to improve the sluggish discharge and charge reactions. For future practical applications, the air cathode must exhibit a usable capacity per unit electrode area, or areal capacity, a critical parameter that has been largely overlooked so far in this field. In order to achieve high areal capacity, the air cathode must exhibit a sufficient amount of accessible void volume per unit electrode area while maintaining the conductive scaffold integrity during the entire electrochemical process. Here we present an ultrathick,holey graphene-based air cathode platform fabricated from a facile dry compression process that exhibits remarkable areal capacity values. Holey graphene is a carbon nanomaterial derived from graphene, but with nanometer sized holes through the nanosheet thickness.The presence of these holes enhances mass transport through electrode thickness and also enables the unique dry-press fabrication process that is not achievable using other carbon scaffold materials.The dry-pressed holey graphene air cathode platform is not only compatible with catalyst incorporation to improve battery reaction kinetics, but also allows for novel engineering of electrode architectures that is not achievable using conventional electrode fabrication approaches.The applications of such highly versatile, ultrahigh areal capacity air cathode platforms to both Li-O2 and Li-CO2 battery chemistries will be discussed.

Li-O2 batteries, Li-CO2 batteries, holey graphene,↗

Validation of Procedures for Monitoring Crewmember Immune Function SDBI-1900, SMO-015 - Integrated Immune

There is ample evidence to suggest that space flight leads to immune system dysregulation. This may be a result of microgravity, confinement, physiological stress, radiation, environment or other mission-associated factors. The clinical risk from prolonged immune dysregulation during space flight are not yet determined, but may include increased incidence of infection, allergy, hypersensitivity, hematological malignancy or altered wound healing. Each of the clinical events resulting from immune dysfunction has the potential to impact mission critical objectives during exploration-class missions. To date, precious little in-flight immune data has been generated to assess this phenomenon. The majority of recent flight immune studies have been post-flight assessments, which may not accurately reflect the in-flight condition. There are no procedures currently in place to monitor immune function or its effect on crew health. The objective of this Supplemental Medical Objective (SMO) is to develop and validate an immune monitoring strategy consistent with operational flight requirements and constraints. This SMO will assess the clinical risks resulting from the adverse effects of space flight on the human immune system and will validate a flight-compatible immune monitoring strategy. Characterization of the clinical risk and the development of a monitoring strategy are necessary prerequisite activities prior to validating countermeasures. This study will determine, to the best level allowed by current technology, the in-flight status of crewmembers immune system. Pre-flight, in-flight and post-flight assessments of immune status, immune function, viral reactivation and physiological stress will be performed. The in-flight samples will allow a distinction between legitimate in-flight alterations and the physiological stresses of landing and readaptation which are believed to alter landing day assessments. The overall status of the immune system during flight (activation, deficiency, dysregulation) and the response of the immune system to specific latent virus reactivation (known to occur during space flight) will be thoroughly assessed. Following completion of the SMO the data will be evaluated to determine the optimal set of assays for routine monitoring of crewmember immune system function, should the clinical risk warrant such monitoring.

Crucian, Brian↗