Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Frequency control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Cascaded resonant bridge converters

A converter for converting a low voltage direct current power source to a higher voltage, high frequency alternating current output for use in an electrical system where it is desired to use low weight cables and other circuit elements. The converter has a first stage series resonant (Schwarz) converter which converts the direct current power source to an alternating current by means of switching elements that are operated by a variable frequency voltage regulator, a transformer to step up the voltage of the alternating current, and a rectifier bridge to convert the alternating current to a direct current first stage output. The converter further has a second stage series resonant (Schwarz) converter which is connected in series to the first stage converter to receive its direct current output and convert it to a second stage high frequency alternating current output by means of switching elements that are operated by a fixed frequency oscillator. The voltage of the second stage output is controlled at a relatively constant value by controlling the first stage output voltage, which is accomplished by controlling the frequency of the first stage variable frequency voltage controller in response to second stage voltage. Fault tolerance in the event of a load short circuit is provided by making the operation of the first stage variable frequency voltage controller responsive to first and second stage current limiting devices. The second stage output is connected to a rectifier bridge whose output is connected to the input of the second stage to provide good regulation of output voltage wave form at low system loads.

Stuart, Thomas A.↗

Digital voltage-controlled oscillator

Digital voltage-controlled oscillator generates a variable frequency signal controlled linearly about a center frequency with high stability and is phase controlled by an applied voltage. Integration ahead of the digital circuitry provides linear operation with control voltage having appreciable noise components.

Saliga, T. V.↗

A Study on Effect of Tuning Capacitor in Dynamic Radioisotope Power Systems

This study presents the effect of the tuning capacitor on stability and electrical power output of a gas-bearing based free-piston Stirling convertor (FPSC) when operating on a fixed-frequency type controller. It has been widely accepted that the tuning capacitor is an important circuit component of the FPSC to stabilize piston amplitude and maximize electrical power output by correcting the power factor. Models suggest the stability of the FPSC is strongly coupled to the tuning capacitance, while the coupling to the electrical power output is weak. This applies to cases where the operating frequency of the FPSC is fixed by a fixed-frequency controller and other operating conditions, such as the hot-end and cold-end temperatures, piston amplitude, and pressure are constant. To verify the modeling analysis results, an Advanced Stirling Convertor (ASC) was controlled by an AC power supply and the piston amplitude, hot-end temperature, cold-end temperature, and pressure are actively controlled to 4.3mm, 760˚C, 40˚C and 485psig, respectively, while the tuning capacitor value was changed from 840μF to 1040μF and 1240μF. Furthermore, the vibration test results of the ASC with different tuning capacitor values are also presented to show the effect of the tuning capacitor on stability. The experimental test results verified that the effect of tuning capacitor on electrical power output is negligible while the effect on stability is rather noticeable. Therefore, the ideal tuning capacitor value should be selected based on required stability of the FPSC.

Free-Piston Stirling Convertor Controller↗

Thoughts and Hypotheses on the Metrics and Needs for the Stability of Highly Inverter-Based Island Systems

As levels of wind, photovoltaics (PVs), and battery energy storage on power systems rise, it is useful to be able to quickly compare how much generation (instantaneous power and annual energy) comes from these inverter-based resources (IBRs). A commonly used metric is the percentage of inverter-based generation (% IBR) in a dispatch scenario (as a percentage of the total generation or total load), which can be useful for estimating when certain operational challenges arise (high rates of change of frequency, underdamped control interactions, low system strength, low fault current availability, and so on). Another similar and commonly used metric pioneered on the relatively large island of Ireland, system nonsynchronous penetration (SNSP), is similar to the % IBR and is subject to similar limitations. SNSP has the advantage of handling high-voltage dc in a defined way.

fault currents↗

A Derivation of the Long-Term Degradation of a Pulsed Atomic Frequency Standard from a Control-Loop Model

The phase of a frequency standard that uses periodic interrogation and control of a local oscillator (LO) is degraded by a long-term random-walk component induced by downconversion of LO noise into the loop passband. The Dick formula for the noise level of this degradation is derived from an explicit solution of an LO control-loop model.

Dick formula local oscillator frequency phase freq↗

Paralleling of LLC Resonant Converters

The LLC resonant converter is a popular, variable switching frequency DC-DC converter that may be controlled using two methods: charge and frequency control. In this paper, the application of LLC resonant converters to input-parallel, output-parallel system is studied. In this respect, the models of output-port I-V characteristics and small-signal output impedance of the charge controlled LLC converter are proposed. In addition, a mathematical framework is developed for droop-based paralleled DC-DC systems. Here, it distinctly identifies the output DC voltage and circulating current modes of stability, even in systems comprising of non-identical converters.

42 ENGINEERING↗

High-power converters for space applications

Phase 1 was a concept definition effort to extend space-type dc/dc converter technology to the megawatt level with a weight of less than 0.1 kg/kW (220 lb./MW). Two system designs were evaluated in Phase 1. Each design operates from a 5 kV stacked fuel cell source and provides a voltage step-up to 100 kV at 10 A for charging capacitors (100 pps at a duty cycle of 17 min on, 17 min off). Both designs use an MCT-based, full-bridge inverter, gaseous hydrogen cooling, and crowbar fault protection. The GE-CRD system uses an advanced high-voltage transformer/rectifier filter is series with a resonant tank circuit, driven by an inverter operating at 20 to 50 kHz. Output voltage is controlled through frequency and phase shift control. Fast transient response and stability is ensured via optimal control. Super-resonant operation employing MCTs provides the advantages of lossless snubbing, no turn-on switching loss, use of medium-speed diodes, and intrinsic current limiting under load-fault conditions. Estimated weight of the GE-CRD system is 88 kg (1.5 cu ft.). Efficiency of 94.4 percent and total system loss is 55.711 kW operating at 1 MW load power. The Maxwell system is based on a resonance transformer approach using a cascade of five LC resonant sections at 100 kHz. The 5 kV bus is converted to a square wave, stepped-up to a 100 kV sine wave by the LC sections, rectified, and filtered. Output voltage is controlled with a special series regulator circuit. Estimated weight of the Maxwell system is 83.8 kg (4.0 cu ft.). Efficiency is 87.2 percent and total system loss is 146.411 kW operating at 1 MW load power.

Park, J. N.↗

JWST Lifting System

A document describes designing, building, testing, and certifying a customized crane (Lifting Device LD) with a strong back (cradle) to facilitate the installation of long wall panels and short door panels for the GHe phase of the James Webb Space Telescope (JWST). The LD controls are variable-frequency drive controls designed to be adjustable for very slow and very-short-distance movements throughout the installation. The LD has a lift beam with an electric actuator attached at the end. The actuator attaches to a rectangular strong back (cradle) for lifting the long wall panels and short door panels from a lower angle into the vertical position inside the chamber, and then rotating around the chamber for installation onto the existing ceiling and floor. The LD rotates 360 (in very small increments) in both clockwise and counterclockwise directions. Eight lifting pads are on the top ring with 2-in. (.5-cm) eye holes spaced evenly around the ring to allow for the device to be suspended by three crane hoists from the top of the chamber. The LD is operated by remote controls that allow for a single, slow mode for booming the load in and out, with slow and very slow modes for rotating the load.

Tolleson, William↗

DynaShape: Dynamic Shaping of Grid Response with Inverters

We consider the problem of controlling the frequency of low-inertia power systems via inverter-based resources (IBRs) that are weakly connected to the grid. We propose a novel grid-forming control strategy, the so-called frequency shaping control, that aims to shape the frequency response of synchronous generators (SGs) to load perturbations so as to efficiently arrest sudden frequency drops. Our solution relaxes several existing assumptions in the literature and is able to navigate trade-offs between peak power requirements and maximum frequency deviations. Finally, we analyze the robustness to imperfect knowledge of network parameters, while particularly highlighting the importance of accurate estimation of these parameters.

frequency-shaping control↗

Dynamic Shaping of Grid Response of Multi-Machine Multi-Inverter Systems Through Grid-Forming IBRs: Preprint

We consider the problem of controlling the frequency response of weakly-coupled multi-machine multi-inverter low-inertia power systems via grid-forming inverter-based resources (IBRs). In contrast to existing methods, our approach relies on dividing the larger system into multiple strongly-coupled subsystems, without ignoring either the underlying network or approximating the subsystem response as an aggregate harmonic mean model. Rather, through a structured clustering and recursive dynamic shaping approach, the frequency response of the overall system to load perturbations is shaped appropriately. We demonstrate the proposed approach for a three-node triangular configuration and a small-scale radial network. Furthermore, for small-scale radial microgrids, we demonstrate the ability of IBRs to tune the effective transfer functions of synchronous machines. This enables us to relax the uniform turbine time-constant assumptions and widen the scope of existing synchronization results for proportionally heterogeneous machines.

frequency-shaping control↗

Fast Grid Frequency Support from Distributed Energy Resources

This report describes research related to electric power system frequency support from inverter-coupled distributed energy resources (DERs). This research was initiated under the U.S. Department of Energy’s Grid Modernization Laboratory Consortium (GMLC) and also contains work funded through a Cooperative Research and Development Agreement with Hawaiian Electric. The purpose of this report is to summarize the findings of simulations, hardware testing, power hardware-in-the-loop (PHIL) simulation, and analysis examining the effects of DER frequency support on the Oahu power system. This report also includes recommendations for consideration in the use of DER grid frequency support functionality, and related topics. Note that a previous GMLC Technical Report from this project also provided specific recommendations for the activation of one specific grid frequency support function, frequency-watt control, for overfrequency events in Hawaii. Those recommendations included recommended frequency-watt control settings, which have since been approved by the Hawaii Public Utilities Commission on October 20, 2017, for system-wide activation. This report builds on the previous report by considering not only overfrequency events but also underfrequency events, and by considering distributed energy storage systems in addition to photovoltaic (PV) systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Frequency-response method for determination of dynamic stability characteristics of airplanes with automatic controls

A frequency-response method for determining the critical control-gearing and hunting oscillations of airplanes with automatic pilots is presented. The method is graphical and has several advantages over the standard numerical procedure based on Routh's discriminant. The chief advantage of the method is that direct use can be made of the measured response characteristics of the automatic pilot. This feature is especially useful in determining the existence, amplitude, and frequency of the hunting oscillations that may be present when the automatic pilot has nonlinear dynamic characteristics. Several examples are worked out to illustrate the application of the frequency-response method in determining the effect of automatic-pilot lag or lead on critical control gearing and in determining the amplitude and frequency hunting. It is shown that the method may be applied to the case of a control geared to airplane motions about two axes.

Greenberg, Harry↗

Characteristics of hingeless rotors with hub moment feedback controls including experimental rotor frequency response, Volume 1

Wind tunnel tests to determine the dynamic characteristics of hingeless rotors with hub moment feedback controls and to acquire experimental hingeless rotor transfer functions are discussed. Rotor transfer functions were calculated from data acquired during open loop frequency response tests. The transfer functions are linear and present the rotor longitudinal and lateral frequency responses to collective pitch, longitudinal cyclic pitch, and lateral cyclic pitch. The theoretical analysis was based on the rigid blade flapping model coupled with appropriate control system and cyclic pitch actuator equations of motion.

Kuczynski, W. A.↗

Re-active Passive (RAP) Devices for Control of Noise Transmission through a Panel

Re-Active Passive (RAP) devices have been developed to control low frequency (<1000 Hz) noise transmission through a panel. These devices use a combination of active, re-active, and passive technologies packaged into a single unit to control a broad frequency range utilizing the strength of each technology over its best suited frequency range. The RAP device uses passive constrained layer damping to cover the relatively high frequency range (>200 Hz), reactive distributed vibration absorber) to cover the medium frequency range (75 to 250 Hz), and active control for controlling low frequencies (<200 Hz). The device was applied to control noise transmission through a panel mounted in a transmission loss test facility. Experimental results are presented for the bare panel, and combinations of passive treatment, reactive treatment, and active control. Results indicate that three RAP devices were able to increase the overall broadband (15-1000 Hz) transmission loss by 9.4 dB. These three devices added a total of 285 grams to the panel mass of 6.0 kg, or approximately 5%, not including control electronics.

Carneal, James P.↗

Frequency weighted system identification and linear quadratic controller design

Application of filters for frequency weighting of Markov parameters (pulse response functions) is described in relation to system/observer identification. The time domain identification approach recovers a model which has a pulse response weighted according to frequency. The identified model is composed of the original system and filters. The augmented system is in a form which can be used directly for frequency weighted linear quadratic controller design. Data from either single or multiple experiments can be used to recover the Markov parameters. Measured acceleration signals from a truss structure are used for system identification and the model obtained is used for frequency weighted controller design. The procedure makes the identification and controler design complementary problems.

Horta, Lucas G.↗

On-line frequency domain information for control of a flexible-link robot with varying payload

Experimental results are given for the endpoint position control of a single-link, very flexible robot arm carrying an unknown, varying payload. The control objective is to maintain endpoint position accuracy in the presence of flexure effects after rapid movement due to a rigid body slew-angle commanded position. Fast, simple, and efficient frequency-domain schemes are used for online controller gain adjustment within an effective scheduling framework. Only endpoint acceleration and motor shaft angle measurements are utilized in relatively simple control laws where the appropriate gains have been scheduled as correlated to modal frequency information corresponding to a varying, unknown payload.

Yurkovich, Stephen↗

Nonlinear Virtual Inertia Control of WTGs for Enhancing Primary Frequency Response and Suppressing Drivetrain Torsional Oscillations

Virtual inertia controllers (VICs) for wind turbine generators (WTGs) have been recently developed to compensate the reduction of inertia in power systems. However, VICs can induce drivetrain torsional oscillations of WTGs. This paper addresses this issue and develops a novel nonlinear VIC based on objective holographic feedback theory and the definition of a completely controllable system of Brunovsky type. Simulation results under various scenarios demonstrate that the proposed technique outperforms existing VICs in terms of enhancement of system frequency nadir, suppression of WTG drivetrain torsional oscillations, fast and smooth recovery of WTG rotor speed to the original maximum power point (MPP) before the disturbance as well as preventing secondary frequency dip caused by traditional VIC. The proposed technique is also able to adaptively coordinate multiple WTGs to enhance the frequency support and the dynamic performance of each WTG.

24 POWER TRANSMISSION AND DISTRIBUTION↗