Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fluorescence Detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

The Quantasyn, an improved quantum detector

Quantasyn provides absolute measurement of radiation flux in the range 1000 A to 4500 A and into the vacuum ultraviolet. This radiation detector cimbines the high quantum efficiency and inherent linearity of the silicon solar cell with the constant quantum response of the fluorescent organic compound liumogen.

Gorstein, M.↗

Probing the magnetsophere with artificial electron beams

An analysis is conducted of the University of Minnesota Electron Echo experiments, which so far have included five sounding rocket experiments. The concept of the Echo experiment is to inject electron beam pulses from a rocket into the ionosphere at altitudes in the range from 100 to 300 km. The electrons move to the conjugate hemisphere following magnetic field lines and return on neighboring field lines to the neighborhood of the rocket where the pulses may be detected and analyzed. Attention is given to the detection and analysis of echoes, the structure of echoes, and the Echo V experiment. The Echo V experiment showed clearly that detection of remote echo beams by atmospheric fluorescence using low light level TV system is not a viable technique. A future experiment is to use throw-away detectors for direct remote echo detection.

Winckler, J. R.↗

Atmospheric gamma-ray and neutron flashes

Gamma-ray pulses are calculated from 2D numerical simulations of an upward atmospheric discharge in a self-consistent electric field using the multigroup approach to the kinetics of relativistic runaway electrons (REs). Computed {gamma}-ray numbers and spectra are consistent with those of terrestrial {gamma}-ray flashes (TGFs) observed aboard spacecrafts. The RE flux is concentrated mainly within the domain of the Blue Jet fluorescence. This confirms that exactly the domain adjacent to a thundercloud is the source of the observed {gamma}-ray flashes. The yield of photonuclear neutrons is calculated. One {gamma}-ray pulse generates {approx}10{sup 14}-10{sup 15} neutrons. The possibility of the direct deposition of REs to the detector readings and the origin of the lightning-advanced TGFs are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Systematic computational study of the effect of silver nanoparticle dimers on the coupled emission from nearby fluorophores.

We use the finite-difference time-domain method to predict how fluorescence is modified if the fluorophore is located between two silver nanoparticles of a dimer system. The fluorophore is modeled as a radiating point dipole with orientation defined by its polarization. When a fluorophore is oriented perpendicular to the metal surface, there is a large increase in total power radiated through a closed surface containing the dimer system, in comparison to the isolated fluorophore and the case of a fluorophore near a single nanoparticle. The increase in radiated power indicates increases in the relative radiative decay rates of the emission near the nanoparticles. The angle-resolved far-field distributions of the emission in a single plane are also computed. This is informative as many experimental conditions involve collection optics and detectors that collect the emission along a single plane. For fluorophores oriented perpendicular to the metal surfaces, the dimer systems lead to significant enhancements in the fluorescence emission intensity in the plane. In contrast, significant emission quenching occurs if the fluorophores are oriented parallel to the metal surfaces. We also examine the effect of the fluorophore on the near-field around the nanoparticles and correlate our results with surface plasmon excitations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

In situ detection of tropospheric OH and HO2 by laser-induced fluorescence in a detection chamber at low pressure

Just as in the method of Hard and O'Brien, ambient air is pulled through an approximately 1 mm diameter inlet into a detection chamber that is maintained at a pressure of 2.4 torr. The ambient air stream travels through the detection chamber with a velocity of greater than 100 m sec(exp -1) in a narrow stream, constrained by the addition of an inert gas flow (0.4 torr). The OH molecule is both excited and detected in the A(exp 2)Sigma (v' = 0) yields X(exp 2)II (v'' = 0) transition at 308 nm. Light from a copper vapor-pumped dye laser (rep. rate = 10kHz; pulse length = 20 ns; linewidth = .1 cm(exp -1), and average power = 15 mW), resonant with the Q(sub 1)(3) transition, is multipassed through a White cell and intercepts the air stream as 24 non-overlapping 2mm by 5mm beams. A fast microchannel plate detector is turned off during the laser pulse to prevent saturation of the detector due to Rayleigh and chamber scattering. It is turned on 30-100 nsec after the end of the laser pulse for 300 ns to collect resonance fluorescence from OH. HO2 is detected by chemical conversion to OH by reaction with reagent NO, followed by OH detection. Both the detection sensitivity and the inlet characteristics must be understood for any in situ instrument. For the calibration of the detection sensitivity, OH is produced quantitatively by the fast H + NO2 yields OH + NO reaction in a low pressure, flowing discharge tube connected to the detection chamber. The inlet transmission of OH inlet is calibrated separately.

Brune, William H.↗

Investigation of the Distribution of Elements in Snail Shell With the use of Synchrotron-Based, Micro-Beam X-ray Fluorescence Spectrometry

In this study, synchrotron-based micro-beam was utilized for elemental mapping of a small animal shell. A thin X-ray spot of the order of {approx}10 em was focused on the sample. With this spatial resolution and high flux throughput, the X-ray fluorescent intensities for Ca, Mn, Fe, Ni, Zn, Cr and Cu were measured using a liquid-nitrogen-cooled 13-element energy-dispersive HpGe detector. The sample is scanned in a estep-and-repeat' mode for fast elemental mapping and generated elemental maps at 8, 10 and 12 keV. All images are of 10 em resolution and the measurement time was 1 s per point. The accumulation of trace elements was investigated from the soft-tissue in small areas. Analysis of the small areas will be better suited to establish the physiology of metals in specific structures like small animal shell and the distribution of other trace elements.

59 BASIC BIOLOGICAL SCIENCES↗

Two-color monochromatic x-ray imaging with a single short-pulse laser

Here, simultaneous monochromatic crystal imaging at 4.5 and 8.0 keV with x-rays produced by a single short-pulse laser is presented. A layered target consisting of thin foils of titanium and copper glued together is irradiated by the 50 TW Leopard short-pulse laser housed at the Nevada Terawatt Facility. Laser-accelerated MeV fast electrons transmitting through the target induce Kα fluorescence from both foils. Two energy-selective curved crystals in the imaging diagnostic form separate monochromatic images on a single imaging detector. The experiment demonstrates simultaneous two-color monochromatic imaging of the foils on a single detector as well as Kα x-ray production at two different photon energies with a single laser beam. Lastly, application of the diagnostic technique to x-ray radiography of a high density plasma is also presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Free-Space Lossless State Detection of a Single Trapped Atom

We demonstrate the lossless state-selective detection of a single rubidium 87 atom trapped in an optical tweezer. This detection is analogous to the one used on trapped ions. After preparation in either a dark or a bright state, we probe the atom internal state by sending laser light that couples an excited state to the bright state only. The laser-induced fluorescence is collected by a high numerical aperture lens. The single-shot fidelity of the detection is 98.6{+-}0.2% and is presently limited by the dark count noise of the detector. The simplicity of this method opens new perspectives in view of applications to quantum manipulations of neutral atoms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Early Career Award: Single Molecule Fluorescence Imaging for a Background-Free Neutrinoless Double Beta Decay Search

This project aimed to develop a suite of novel technologies targeted at detecting individual barium ions produced in neutrinoless double beta decays of 136 Xe, as part of the NEXT program of gaseous xenon detectors. We realized novel molecules which could sense Ba 2+ ions in dry conditions; new microscopy techniques operable in dry noble gases, including the required operating conditions of xenon at 10 bar pressure; and new radiofrequency ion transport methods (developed both theoretically and experimentally) that can transport ions in dense xenon gas. Together, these developments represent a major advance toward a background-free neutrinoless double beta decay experiment based on single molecule fluorescence imaging of Ba 2+ daughter ions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Chromato-fluorographic drug detector

A drug detecting apparatus which includes a chromatographic system for separating particular substances from a sample solution passed through it is described. A source of radiation causes the substance to emit fluorescent radiation as it moves through the chromatographic system. An optical system spectrally separates the fluorescent radiation according to wavelength and for focusing particular portions of the separated spectrum through an exit aperture. A photodetector which is responsive to the radiation passing through the exit aperture develops an electrical signal commensurate with the intensity of the radiation. The electrical signal is recorded to provide an indication of certain characteristics of the substance.

Parker, J. A.↗

Soft X-ray bremsstrahlung and fluorescent line production in the atmosphere by low energy electrons

The effect of low energy quasi-trapped or precipitating electrons which impact on the counter windows of soft X-ray detectors are discussed. The errors caused by X-rays produced in the residual atmosphere above a rocket-borne detector because of the resemblance to X-rays of cosmic origin are examined. The design and development of counter windows which make it possible to identify the atmospherically produced X-rays are described. Curves are presented to show the following: (1) preliminary low energy electron data from Atmospheric Explorer C, (2) X-ray flux in electron-excited nitrogen and oxygen, (3) typical proportional counter response to low energy cosmic rays, and (4) proportional counter response to X-radiation produced by electrons incident upon a gas of oxygen to nitrogen number of 0.4.

Kraushaar, W. L.↗

SU-E-T-526: On the Linearity, Stability and Beam Energy Dependence of CdSe Quantum Dots as Scintillating Probes

Purpose: Structure and energy transfer mechanisms confer colloidal quantum dots (cQDs) interesting properties, among them their potential as scintillators. CdSe multi-shell cQDs in powder were investigated under photons irradiation. The purpose of this work is to characterize signal to dose linearity, stability with time and to quantify the dependence of their light output with beam energy. Methods: The cQDs are placed at the extremity of a non-scintillating plastic collecting fiber, with the other extremity connected to an Apogee U2000C CCD camera. The CCD camera collects the fluorescence light from irradiated cQDs from which the delivered dose is extracted. This signal is corrected for Cerenkov contamination at MV energies using the chromatic technique. The detector was irradiated with two devices: Xstrahl 200 orthovoltage unit for 120, 180 and 220 kVp and a Varian Clinac iX for 6 and 23 MV. Results: Linear output response with varying dose is observed for all beam energies with R2 factors > 0,999. Reproducibility measurements were performed at 120 kVp: the same set-up was irradiated at different time intervals (one week and three months). The results showed only a small relative decrease of light output of 3,2 % after a combine deposited dose of approximately 95 Gy. CdSe nanocrystals response has been studied as a function of beam energy. The output increases with decreasing energy from 120 kVp to 6 MV and increase again for 23 MV. This behavior could be explained in part by the cQDs high-Z composition. Conclusion: The fluorescence light output of CdSe cQDs was found to be linear as a function of dose. The results suggest stability of the scintillation output of cQDs over time. The specific composition of cQDs is the main cause of the observed energy dependence. We will further look into particle beam dependence of the cQDs. Bourse d'excellence aux etudes graduees du CRC (Centre de Recherche sur le Cancer, Universite Laval) Bourse d'excellence aux etudes graduees du CRC (Centre de Recherche sur le Cancer, Universite Laval)

60 APPLIED LIFE SCIENCES↗

Soft X-rays from the sunlit earth's atmosphere

Observations of soft X-ray emission from the sunlit earth atmosphere are presented and compared with the predictions of an earth albedo X-ray theory. The exact theory accounts for the flux of Thomson scattered solar X rays and fluorescently excited K X rays that arise following the absorption of incident X rays as a function of observing geometry. Observations were made at widely separated geometries with the two low-energy detectors of the A-2 experiment on the HEAO-1 satellite. Fitting of the model to the observed spectra results in values for the solar coronal temperature and emission measure that are in good agreement with expected values for the nonflaring sun, indicating that X-ray observations of the sunlit atmosphere may be a useful monitor of solar activity for satellites unable to view the sun directly. The total measured fluorescent line flux is also in agreement with calculations, although the N/O line ratio is not. X-ray fluorescence measurements from the sunlit atmosphere will thus be useful in monitoring atmospheric composition only to the extent that the total line counting rates depend upon the composition.

Mckenzie, D. L.↗

X-Ray Detector Research at MSFC for Space Applications

NASA's Vision for Space Exploration has specific goals aimed at exploring the Solar System. This vision, under presidential mandate includes landing humans on the moon before the end of the next decade, paving the way for eventual journeys to Mars and beyond. The first missions to the moon will be in the form of both Orbiters and Landers, with the goal of paving the way for human return. One of the instruments we are currently working on,in collaboration with Brookhaven National Laboratory, is a lunar orbiter fluorescent x-ray spectrometer to finely map the light elements (down to Carbon) on surface of the moon. Funded NASA s Planetary Instrument Definition and Development Program the instrument is based on silicon drift detector arrays read out by custom ASICs. These offer the promise of high spectral resolution, necessary for resolving weak lines against a strong background continuum, and very low power requirements, necessary for large areas (greater than 500 square centimeters) required for future lunar missions. Further, the inherent radiation hardness of these detectors makes them ideal candidates for exploring the Jovian system, where the harsh radiation environment from Jupiter s radiation belts creates unfavorable detector conditions. Looking beyond our solar system, in the hard x-ray regime (20-80keV.), we are studying Cadmium-Zinc-Telluride pixilated detectors as feasible candidates for focal plane detectors of a hard x-ray telescope. This energy region bridges the gap between thermal and non-thermal x-ray emission from astronomical sources, will allow us to better understand supernovae nucleosynthesis (such as through the Ti-44 lines at 68keV and 78keV), Active Galactic Nuclei and other compact objects, more completely. The detectors that we are characterizing are 2mm in thickness and are pixilated with a 16x16 array of 300 micrometer pitch pixels (50micometer gap). These detectors are designed at Rutherford Appleton Laboratory, material is from eV Products, and polymer flip-chip assembly was performed by a commercial vendor. An energy resolution of 2.0% at 60keV (or better) should allow us to sufficiently distinguish lines of interest from background continuum, and the detector spatial resolution should be fine enough to over-sample the focal spot from the x-ray focusing optics by about a factor of two. Full technical details of these developments will be presented.

Gaskin, Jessica↗

Linearity for Ca2+-Doped CeBr3 Scintillating Materials

The National Security Technologies, LLC, Remote Sensing Laboratory (RSL) developed an aliovalently calcium-doped cerium tribromide (CeBr3:Ca2+) crystal with a FWHM resolution of 3.2% at the 137Cs 662 keV gamma energy. RSL completed a crystal assessment and Sandia National Laboratories calculated the predictive performance and physical characteristics using proven density functional theory (DFT) formalism. Results are reported for the work done to map the detector performance, characteristics, calcium doping concentration, and crystal strength. Preliminary scintillation measurements for this aliovalently calcium-doped CeBr3 scintillator exhibit a slight blue shift in fluorescence emission at 371 nm excitation for CeBr3. The structural, electronic, and optical properties of CeBr3 crystals were investigated using the DFT within generalized gradient approximation. The calculated lattice parameters are in good agreement with the experimental data. The energy band structures and density of states were obtained. The optical properties of CeBr3, including the dielectric function of photons per unit energy, were calculated. Specifically, we report excellent linearity with the aliovalent CeBr3:Ca2+ crystal. Proportionality of light yield is one area of performance in which Ce-doped and Ce-based lanthanide halides excel. Maintaining proportionality is the key to producing a strong, high-performance scintillator. Relative light yield proportionality was measured for both doped and undoped samples of CeBr3 to ensure no loss in performance was incurred by doping. The light output and proportionality, however, appear to be similar to CeBr3. There was a reduced yield at low energy. Relative light yield proportionality measurements suggest that dopants do not significantly affect proportionality at higher energies. RSL completed additional testing and evaluation of the new crystal as well as the assessment of benchmarking spectroscopy. Results, which present energy resolution as a function of energy, are summarized. Typical spectroscopy results using a 137Cs radiation source are shown for our crystallites with diameters <1 cm. We obtain 3.2% before packing the crystallite in a sealed detector container and 4.5% for the packaged crystallite. More spectra were obtained for 241Am, 60Co, 228Th, and background to exemplify CeBr3:Ca2+ over a broader energy range.

aliovalent substitution↗

Radioactive sample effects on EDXRF spectra

Energy dispersive X-ray fluorescence (EDXRF) is a rapid, straightforward method to determine sample elemental composition. A spectrum can be collected in a few minutes or less, and elemental content can be determined easily if there is adequate energy resolution. Radioactive alpha emitters, however, emit X-rays during the alpha decay process that complicate spectral interpretation. This is particularly noticeable when using a portable instrument where the detector is located in close proximity to the instrument analysis window held against the sample. A portable EDXRF instrument was used to collect spectra from specimens containing plutonium-239 (a moderate alpha emitter) and americium-241 (a heavy alpha emitter). These specimens were then analyzed with a wavelength dispersive XRF (WDXRF) instrument to demonstrate the differences to which sample radiation-induced X-ray emission affects the detectors on these two types of XRF instruments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Atmospheric pion, kaon, and muon fluxes for sub-orbital experiments

Cosmic rays interacting with the Earth's atmosphere generate extensive air showers, which produce Cherenkov, fluorescence and radio emissions. These emissions are key signatures for detection by ground-based, sub-orbital, and satellite-based telescopes aiming to study high energy cosmic ray and neutrino events. However, detectors operating at ground and balloon altitudes are also exposed to a background of atmospheric charged particles, primarily pions, kaons, and muons, that can mimic or obscure the signals from astrophysical sources. In this work, we use coupled cascade equations to calculate the atmospheric pion, kaon and muon fluxes reaching detectors at various altitudes. Our analysis focuses on energies above 10 GeV, where the influence of the Earth's magnetic field on particle trajectories is minimal. We provide angular and energy-resolved flux estimates and discuss their relevance as background for extensive air shower detection. Furthermore, our results are potentially relevant for interpreting data from current and future balloon-borne experiments such as EUSO-SPB2 and for refining trigger and veto strategies in Cherenkov and fluorescence telescopes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Radiation Laboratory Curriculum Development at Western Kentucky University

We present the latest developments for the radiation laboratory curriculum at the Department of Physics and Astronomy of Western Kentucky University. During the last decade, the Applied Physics Institute (API) at WKU accumulated various equipment for radiation experimentation. This includes various neutron sources (computer controlled d-t and d-d neutron generators, and isotopic 252 Cf and PuBe sources), the set of gamma sources with various intensities, gamma detectors with various energy resolutions (NaI, BGO, GSO, LaBr and HPGe) and the 2.5-MeV Van de Graaff particle accelerator. XRF and XRD apparatuses are also available for students and members at the API. This equipment is currently used in numerous scientific and teaching activities. Members of the API also developed a set of laboratory activities for undergraduate students taking classes from the physics curriculum (Nuclear Physics, Atomic Physics, and Radiation Biophysics). Our goal is to develop a set of radiation laboratories, which will strengthen the curriculum of physics, chemistry, geology, biology, and environmental science at WKU. The teaching and research activities are integrated into real-world projects and hands-on activities to engage students. The proposed experiments and their relevance to the modern status of physical science are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗