Visibility of Hypovascularized Liver Tumors during Intra-Arterial Therapy Using Split-Bolus Single-Phase Cone Beam CT

Purpose: To validate a split-bolus contrast injection protocol for single-phase CBCT in terms of detectability of hypovascular liver tumors compared to digital subtraction angiography (DSA). Materials and Methods: In this retrospective, single-center study, 20 consecutive patients with in total 77 hypovascularized tumors referred for intra-arterial therapy received a split-bolus single-phase CBCT. Two readers rated the visibility of the target tumors scheduled for embolization in CBCT and DSA compared to the pre-interventional multiphasic CT or MRI used as reference on a 3-point scoring system (1 = optimal, 3 = not visible) and catheter-associated artifacts (1 = none, 3 = extended). SNR, CNR and contrast values were derived from 37 target tumors in CBCT and MRI. Statistical analysis included the kappa test to determine interrater reliability, the Friedman’s test for the inter-modality comparison evaluating tumor visibility in DSA and CBCT as well as for quantitative assessment. Post hoc analysis included the Wilcoxon signed-rank test. p values < 0.05 were considered significant. Results: Ninety percentage of target tumors were rated as visible in CBCT and 37.5% in DSA (p < 0.001). 70.1% of pre-interventionally detected hypovascularized tumors were depicted with CBCT and 31.2% by DSA (p < 0.001). 7.8% of known tumors were outside the FOV. Quantitative assessment showed higher image contrasts in CBCT (1.91 ± 7.01) compared to hepatobiliary-phase MRI (0.29 ± 0.14, p = 0.003) and to portal-venous (p.v.) MRI (0.31 ± 0.13, p < 0.001), but higher CNR for MRI (1.18 ± 0.80; 13.92 ± 15.82; 13.79 ± 6.65). Conclusion: In conclusion, the split-bolus single-phase CBCT detects significantly more hypovascularized liver tumors compared to DSA performed through the proper hepatic artery with high image contrasts. Level of Evidence: Level III, diagnostic study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ice Ball Crack During CT-Guided Renal Cryoablation Using 1.5-mm-Diameter Cryoprobes

Ice ball fracture and massive hemorrhage are serious complications associated with renal cryoablation. When cracks occur in an ice ball, it is usually associated with adjacent renal parenchymal fracture, leading to massive hemorrhage. However, few studies have examined ice ball fracture under image-guided percutaneous renal cryoablation. We herein describe an 80-year-old male patient who had undergone CT-guided cryoablation for a left renal tumor using four cryoprobes (1.5 mm diameter each). Ice ball cracks were observed on CT images during cryoablation. However, there was no massive hemorrhage and further treatments were not necessary. This is the first report of ice ball cracks with a smaller diameter cryoprobe, which has not been considered to be associated with ice ball fracture.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Zilver PTX Post-market Surveillance Study of Paclitaxel-Eluting Stents for Treating Femoropopliteal Artery Disease in Japan: 2-Year Results

Purpose: A prospective, multicenter post-market surveillance study in Japan evaluated the 2-year safety and effectiveness of the DES in real-world patients with complex femoropopliteal artery lesions. Methods: There were no exclusion criteria, and consecutive symptomatic patients with femoropopliteal lesions treated with the DES were enrolled in the study. Clinically driven target lesion revascularization (TLR) was defined as reintervention performed for > 50% diameter stenosis after recurrent clinical symptoms of peripheral arterial disease. Clinical benefit was defined as freedom from persistent or deteriorating ischemic symptoms. Patency was evaluated by duplex ultrasound where physicians considered this standard of care. Results: In this study, 905 patients were enrolled at 95 institutions in Japan. There were numerous comorbidities including a high incidence of diabetes (58.8%) and chronic kidney disease (43.6%). Additionally, 21.4% of patients were classified with critical limb ischemia. Lesions were complex, with an average length of 14.6 ± 9.6 cm (range 0.5–40 cm), 41.5% total occlusions, and 18.7% in-stent restenosis. In total, 1861 DES were placed in 1080 lesions. Two-year follow-up was obtained for > 90% of eligible patients. Freedom from TLR was 83.7%, and clinical benefit was 80.0% through 2 years. The 2-year primary patency rate was 70.3%. Rutherford classification significantly improved (p < 0.01), with approximately 80% of patients classified as Rutherford class 0 or 1 at 2 years. Conclusion: Despite more challenging lesion characteristics, 2-year results from the current study are similar to outcomes from the previous Zilver PTX studies, confirming the efficacy of the Zilver PTX DES in a complicated femoropopliteal lesion (Zilver PTX Post-Market Study in Japan; NCT02254837). Level of Evidence: Post-market surveillance study, Level III.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Patency Recovery and Biodegradable Stent Placement in a Totally Occluded Hepaticojejunostomy After Paediatric Living Donor Liver Transplantation

Biliary complications after living donor liver transplantation (LDLT) cause severe morbidity and mortality, with biliary anastomotic stricture being the most common form of presentation. Surgical revision is risky, and it is avoided whenever possible. When a Roux-en-Y hepaticojejunostomy (RYHJ) is used for bilioenteric reconstruction, endoscopic approach is more difficult, if not impracticable. Therefore, percutaneous approach remains as a first-line treatment in these patients. In this case presentation, a percutaneous approach was used to recover patency in an intractable, totally occluded RYHJ stricture in an LDLT paediatric recipient, using a Rösch-Uchida needle to access to the collapsed jejunal loop from the bile duct. Once recanalization of the RYHJ was achieved, a biodegradable stent was placed with middle-term patency at follow-up.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparative Analysis of Intra-arterial Cone-Beam Versus Conventional Computed Tomography During Hepatic Arteriography for Transarterial Chemoembolization Planning

Purpose: To compare the imaging characteristics of intra-arterial cone-beam computed tomography during hepatic arteriography (CBCTHA) versus intra-arterial computed tomography during hepatic arteriography (CTHA) for intraprocedural transarterial chemoembolization (TACE) planning. Materials and Methods: This single-institution retrospective study included 144 patients (96 men, mean age 67.9 years; 48 women, mean age 62.3 years) who underwent 181 TACE sessions between January 2015 and July 2017. Intraprocedural CBCTHA (111 procedures) or CTHA (70 procedures) was performed for TACE planning. Reformatted maximum intensity projection CBCTHA and CTHA images were reviewed by two radiologists and classified using an ordinal scoring system (for tumor identification, tumor feeder vessel identification, and streaking artifact) and a binary scoring system (for the presence of breathing motion artifact and field of view encompassing the entire liver). Data were analyzed using an F test and a z-score test. Results: There were no significant differences in demographic and tumor characteristics between the CBCTHA and CTHA patient cohorts. CTHA was superior to CBCTHA for tumor identification (P < .0001), tumor feeder vessel identification (P < .05), streaking artifact (P < .0001), and field of view encompassing the entire liver (P < .0001). There was a trend toward a lower frequency of breathing motion artifact with CTHA than with CBCTHA (1.4% vs. 10%; P = .057). Conclusion: CTHA provides improved clinical relevant imaging information compared to CBCTHA for intraprocedural TACE planning. Level of Evidence: Level III, retrospective comparative study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Study of Percutaneous Stent Placement with Iodine-125 Seed Strand for Malignant Biliary Obstruction

Purpose: To evaluate the effectiveness and safety of simultaneous placement of a self-expandable metallic stents (SEMS) and iodine-125 seed strand in the management of malignant obstructive jaundice (MOJ). Materials and Methods: This study included 132 patients with MOJ treated from November 2015 to October 2017. Forty-five patients underwent insertion of SEMS with iodine-125 seed strands (Seeds group); the remaining 87 patients underwent SEMS placement alone (Control group). Technical success was defined as accurate, successful deployment of SEMS with or without iodine-125 seed strand; clinical success was defined as 20% reduction in serum bilirubin within 1 week after the procedure, compared with baseline. Complications, duration of primary stent patency, and overall survival were evaluated. Results: Technical success was achieved in all patients in both groups. In the Seeds group, an average of 14 seeds (range 8–22) were implanted in the bile duct as a strand. Clinical success rates were similar between the groups (Seeds group, 93.3%; Control group, 95.4%). Major complications occurred in only one patient, in the Control group. The median period of primary stent patency was significantly longer in the Seeds group (194 days) than in the Control group (86 days; P = 0.049). The median overall survival was also significantly longer in the Seeds group (194 days) than in the Control group (96 days; P = 0.031). Conclusion: SEMS combined with iodine-125 seed strands is effective and safe in the management of MOJ and can improve stent patency and patient survival.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Catheter-Directed Fenestration for Branch Vessel Reconnection in Aortic Dissection Using a Novel Diamond-Tipped Chronic Total Occlusion Drilling Device: A Technical Report

Purpose: Aortic dissection is a complex condition with high morbidity and mortality. Endovascular treatments including percutaneous fenestration can be used to manage branch vessel ischaemia or risk of aortic rupture. A variety of techniques for aortic fenestration have been described. We describe the novel use of the TruePath Chronic Total Occlusion (CTO) device for aortic intimal fenestration to achieve side branch reconnection. Materials and Methods: We present three cases of aortic dissection presenting with symptoms of aortic side branch occlusion and end organ malperfusion, treated with aortic fenestration using the TruePath CTO device via trans-brachial and trans-femoral approaches. Results: Technical success was achieved in all three cases. No complications were encountered. Flow was restored in compromised visceral branches. Branches remained patent on follow-up CT angiography over a minimum 2.5-year follow-up period. Conclusion: Percutaneous aortic fenestration techniques enable a minimally invasive approach to treat visceral branch malperfusion associated with aortic dissection. The TruePath CTO device improves the control of the fenestration procedure with the potential to improve efficacy and safety.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multiple Bifurcated Covered Self-Expanding Metallic Stents for Complex Tracheobronchial Fistulas or Stenosis

Objective: We aimed to determine the safety and feasibility of bifurcated covered self-expanding stents for the treatment of complex tracheobronchial fistulas or stenosis. Methods: Twenty-eight patients were treated by multiple bifurcated covered airway stents (Micro-Tech Co. Ltd., Nanjing, China), including 18 cases of gastrobronchial or gastrotracheal fistula, 6 cases of bronchopleural fistula and 4 cases of severe tracheobronchial stenosis. The large bifurcated covered stent was placed at the main carina, and the small stents were inserted into primary right carina or secondary left carina. Clinical and imaging data were retrospectively analyzed. Results: Stents were successfully inserted in 27 patients at the first attempt. In total, 29 large bifurcated covered stents, 27 small bifurcated covered stents and 5 small bifurcated covered single-plugged stents were inserted. All patients with fistula could resume eating without coughing after the procedure. No perioperative death or severe complications occurred. Two patients underwent stent removal due to intolerance of stenting; the clinical success rate was 93% (26/28). Nineteen complications were found in 12 patients; 8 patients needed stent removal or replacement, for a major complication rate of 29% (8/28). Eight patients underwent successful stent removal due to complications. Fifteen patients died of tumors and one patient died of pulmonary infection. The median survival was 33 months. Fistula recurrence was found in one patient 5 months after stenting, and second small bifurcated covered stent was inserted. Conclusions: Multiple bifurcated covered metallic stenting is effective and safe for complex tracheobronchial fistulas or stenosis, with good symptom palliation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Advantages of Intraprocedural Unenhanced CT During Adrenal Venous Sampling to Confirm Accurate Catheterization of the Right Adrenal Vein

Purpose: To evaluate the advantages of intraprocedural CT during adrenal venous sampling (AVS) to confirm accurate catheterization of the right adrenal vein (RAV). Materials and Methods: This single-institution study included 106 patients (mean age 52.4 years; range 28–74 years) with primary aldosteronism who performed contrast-enhanced CT (CECT) before AVS following AVS between January 2011 and March 2018. After catheterization of the RAV under fluoroscopic guidance, unenhanced CT images were obtained to confirm catheter position on unified CT angiography system. Catheter repositioning was performed when the catheter was inaccurately positioned. Venography findings were classified into two groups: (1) presumably cannulated in the RAV (presumed RAV group) and (2) obscured visualization of the RAV because of collateral vessels (obscured RAV group). Success rates of AVS were compared using Fisher’s exact test. Results: The overall success of AVS was achieved in 104 patients (98.1%). Catheter was deviated into the IVC during intraprocedural CT in four patients. Fourteen patients (14.0%) required catheter repositioning by intraprocedural CT images, and accurate catheterization in the RAV was eventually accomplished. The success rate of AVS was significantly higher in the presumed RAV group (90.1% [73/81]) than that in the obscured RAV group (68.4% [13/19]) (p = 0.024). If intraprocedural CT was not acquired during AVS, the success rate of AVS would have been significantly lower (84.9% [90/106]) compared with that use of intraprocedural CT (98.1% [104/106]) (p < 0.001). Conclusions: Intraprocedural unenhanced CT by referring to the preprocedural CECT before AVS enables the confirmation of accurate catheterization of the RAV. Level of Evidence: Level 4, case series.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nuclear Factor-κB is Activated in Filter-Implanted Vena Cava

Background: Implantation of a retrievable vena cava filter (VCF) is an effective method for preventing pulmonary embolism. Retrieval of filters, however, may be difficult due to intimal hyperplasia and inflammation in the cava wall. The transcription factor nuclear factor-kappaB (NF-κB) plays an important role in regulation of numerous genes participating in the inflammatory and proliferative responses of cells. The present study was to determine whether VCF implantation resulted in activation of NF-κB in the venous neointima. Methods: Filters were placed in vena cava (VC) in four swine for 30 days and then removed. Intimal specimens adhering to the filter struts were analyzed with reference to normal VC tissues. Immunohistochemical analyses were used to assess the NF-κB subunits p65 and p50 and the phosphorylated inhibitor of κB-α (phosphor-IκB-α) in the tissues. NF-κB DNA-binding activity was measured with enzyme-linked immunosorbent assay. Results: As compared to normal VC tissues, the intimal tissues contained higher percentages of cell nucleus-located p65 and p50, and NF-κB DNA-binding activity. Elevated immunoreactivities of p65, p50 and phosphor-IκB-α were also present in the intima. Conclusion: The present study demonstrates for the first time that VCF implantation caused NF-κB activation in neointima. We further demonstrate the activation is at least partly due to phosphorylation of IκB-α. Our data suggest that NF-κB activation would significantly contribute to development of intimal hyperplasia and inflammation in filter-inserted vena cava walls. NF-κB might be a therapeutic target for inhibiting filter-induced neointima and improving filter retrieval.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

End-hole Versus Microvalve Infusion Catheters in Patients Undergoing Drug-Eluting Microspheres-TACE for Solitary Hepatocellular Carcinoma Tumors: A Retrospective Analysis

Introduction: Pre-transplant locoregional therapy for hepatocellular carcinoma (HCC) during bridge-to-transplant impacts recurrence and survival rates following liver transplantation. Optimizing the effectiveness of transarterial chemoembolization (TACE) in this population is imperative, and microvalve infusion catheters offer a means of such improvement. Methods: All treatment-naive patients with solitary HCC tumors < 6.5 cm who underwent drug-eluting microspheres (DEM) TACE between 04/2015 and 08/2017 were retrospectively reviewed. Eighty-eight included patients underwent DEM-TACE with either standard end-hole catheters (EH) or microvalve infusion catheters (MVI). The EH (n = 70) and MVI (n = 18) cohorts had similar baseline tumor size, laboratory values, and tumor etiologies. Results: Initial objective response rates were significantly higher in MVI vs. EH (100% vs. 76.5%, p = 0.019). There was no difference in adverse events between groups (p = 0.265). MVI patients exhibited lower AST (p = 0.003) and ALT (p = 0.044) at 6 months. Blinded pathological analysis of explanted livers showed greater concentrations of microspheres within the tumor relative to the surrounding tissue in MVI explants (88.7 ± 10.6%) versus the EH explants (55.3 ± 32.7%) (p = 0.002). There was significantly higher percentage tumor necrosis in the MVI group (89.0 ± 2.2%) compared with the EH group (56.1 ± 44.5%) (p = 0.006). Conclusion: In this retrospective study of a single-center cohort, DEM-TACE procedures with MVI were associated with improved tumor response, increased deposition of microspheres within tumor tissue, and higher percentage tumor necrosis at explant relative to those performed using EH catheters.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Combined Y-Shaped Covered Metallic Stents for Gastrobronchial Fistulas Involving the Right Intermediate Bronchus

Gastrobronchial fistula that involves the right intermediate bronchus is an extremely rare complication of esophagectomy. In this report, two patients with gastrobronchial fistulas around the secondary right carina were treated by combined Y-shaped covered metallic stents. Four covered stents were inserted successfully at the first attempt with no complications. The gastrobronchial fistula was fully sealed in each patient, and they were able to eat without coughing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Application of Multivariate Curve Resolution–Alternate Least Square Technique on Extracting Pure Spectral Components from Multiple Emitting Systems: a Case Study

Multiple emitting components in a fluorophoric system often produce complicated emission spectra. Extracting the individual spectral information from the composite spectra is important in order to comprehend the photophysical processes occurring in the multifluorophoric systems. Although the combination of Principal Component Analysis and Multivariate Curve Resolution-Alternate Least Square (PCA/MCR-ALS) technique is a well-known approach for curve deconvolution, its applicability in the spectral deconvolution of vibronically and electronically mixed up emitting systems as well as systems merged up with multiple electronic bands without a priori knowledge of the individual emitting species, is not properly studied. The present work highlights the strength of PCA/MCR-ALS in retrieving pure spectral information from the set of complex spectra arising out of the regular variation of causative factors that result in the variation of spectral composition. The retrieval of the emission bands utilizing the PCA/MCR-ALS technique has been made without having a priori information of the emitting species present in the multifluorophoric systems and the resolved spectra correspond well with the fluorescence spectra of the individual chemical species. The common curve fitting methods such as Gaussian and Lorentzian techniques have been found to be unsuccessful in providing meaningful photophysical information through the retrieved spectra. A comparative study of the curve fitting techniques MCR-ALS, Gaussian and Lorentzian in a set of complicated emission spectra of (i) pyrene and its excimer, (ii) pyrene and its excimer in presence of benzo[a]pyrene, and (iii) fisetin in bile salt medium is presented herein in details.

74 ATOMIC AND MOLECULAR PHYSICS↗

In vivo determination of total knee arthroplasty kinematics

The objective of this study was to determine if consistent posterior femoral rollback of an asymmetrical posterior cruciate retaining (PCR) total knee arthroplasty was mostly influenced by the implant design, surgical technique, or presence of a well-functioning posterior cruciate ligament (PCL). Three-dimensional femorotibial kinematics was determined for 80 subjects implanted by 3 surgeons, and each subject was evaluated under fluoroscopic surveillance during a deep knee bend. All subjects in this present study having an intact PCL had a well-functioning PCR knee and experienced normal kinematic patterns, although less in magnitude than the normal knee. In addition, a surprising finding was that, on average, subjects without a PCL still achieved posterior femoral rollback from full extension to maximum knee flexion. The findings in this study revealed that implant design did contribute to the normal kinematics demonstrated by subjects having this asymmetrical PCR total knee arthroplasty.

59 BASIC BIOLOGICAL SCIENCES↗

Fiducial-Based Translational Localization Accuracy of Electromagnetic Tracking System and On-Board Kilovoltage Imaging System

Purpose: The Calypso medical four-dimensional localization system uses AC electromagnetics, which do not require ionizing radiation, for accurate, real-time tumor tracking. This investigation compared the static and dynamic tracking accuracy of this system to that of an on-board imaging kilovoltage X-ray system for concurrent use of the two systems. Methods and Materials: The localization accuracies of a kilovoltage imaging system and a continuous electromagnetic tracking system were compared. Using an in-house developed four-dimensional stage, quality-assurance fixture containing three radiofrequency transponders was positioned at a series of static locations and then moved through the ellipsoidal and nonuniform continuous paths. The transponder positions were tracked concurrently by the Calypso system. For static localization, the transponders were localized using portal images and digitally reconstructed radiographs by commercial matching software. For dynamic localization, the transponders were fluoroscopically imaged, and their positions were determined retrospectively using custom-written image processing programs. The localization data sets were synchronized with and compared to the known quality assurance fixture positions. The experiment was repeated to retrospectively track three transponders implanted in a canine lung. Results: The root mean square error of the on-board imaging and Calypso systems was 0.1 cm and 0.0 cm, respectively, for static localization, 0.22 mm and 0.33 mm for dynamic phantom positioning, and 0.42 mm for the canine study. Conclusion: The results showed that both localization systems provide submillimeter accuracy. The Calypso and on-board imaging tracking systems offer distinct sets of advantages and, given their compatibility, patients could benefit from the complementary nature of the two systems when used concurrently.

62 RADIOLOGY AND NUCLEAR MEDICINE↗