Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Enthalpy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Vaporization of the group IVB metal carbides

High temperature vaporization of titanium, zirconium, hafnium and thorium carbides by Knudsen effusion mass spectrometry, measuring ion intensities, formation enthalpies and dissociation energies

Kohl, F. J.↗

Thermal Analysis Methods and Basic Heat-Transfer Data for a Turbulent Heating Flight Experiment at Mach 20 (Reentry F)

A heat-transfer experiment was flight conducted on a 5 deg half-angle cone, 396.2 cm (13 ft) in length, as it entered the sensible atmosphere under laminar, transitional, and turbulent boundary-layer conditions at a free-stream Mach number of about 20. Accurate turbulent-heat-transfer data with natural transition were obtained for correlation with theories in regions of simultaneous high Mach number, Reynolds number, enthalpy, and total-to-wall temperature ratio. Temperatures were measured at four depths through the 15.24-mm-thick (0.600-in.) beryllium wall. Experimental heating rates at 20 stations on the cone were determined independently from the outermost temperature measurement and from the temperature measurement at the second depth by a single-thermocouple inverse method and also from the temperature histories at all four depths by an integral method. The thermal data analysis procedure, associated problems, and results are presented herein.

Howard, Floyd G.↗

Analysis of Free-Flight Laminar, Transitional, and Turbulent Heat-Transfer Results at Free-Stream Mach Numbers Near 20 (Reentry F)

Laminar, transitional, and turbulent heat-transfer data were measured during a reentry flight at a Mach number of 20 on a 5 deg half-angle cone 3.962 m (13 ft) long with an initial nose tip radius of 0.254 cm (0.1 in.). The free-stream Reynolds number increased during the prime data period from 7.0 x 10(exp 6) to 51.5 x 10(exp 6) per meter (2.1 x 10(exp 6) to 15.7 x 10(exp 6) per foot) and the ratio of wall to total temperature varied from 0.053 to 0.12. The angle of attack was less than 1deg for the prime data period. The experimental laminar and turbulent heating rates are compared with results from existing flat-plate prediction methods. At conditions of minimal tip blunting and angle of attack (above 26.8 km (88 000 ft)), values from a flat-plate laminar method agreed within 20 percent with the laminar data. The Schultz-Grunow skin-friction equation with reference enthalpy; conditions, with the Reynolds number based on distance from the transition location, and with the Colburn Reynolds analogy agreed within 10 percent with the experimental turbuleiit heating data. The Van Driest n skin-friction equation with Reynolds number greater than 10(exp 7) based on distance from the peak heating point and the Colburn Reynolds analogy was also within approximately 10 percent of the experimental turbulent heating data. A data correlation jbf the extent of transition and a simple empirical transition-zone heating correlation were also presented.

Zoby, Ernest V.↗

Computer program for natural gas flow through nozzles

Subroutines, FORTRAN 4 type, were developed for calculating isentropic natural gas mass flow rate through nozzle. Thermodynamic functions covering compressibility, entropy, enthalpy, and specific heat are included.

Johnson, R. C.↗

Pulsed electromagnetic gas acceleration

Experimental data were combined with one-dimensional conservation relations to yield information on the energy deposition ratio in a parallel-plate accelerator, where the downstream flow was confined to a constant area channel. Approximately 70% of the total input power was detected in the exhaust flow, of which only about 20% appeared as directed kinetic energy, thus implying that a downstream expansion to convert chamber enthalpy into kinetic energy must be an important aspect of conventional high power MPD arcs. Spectroscopic experiments on a quasi-steady MPD argon accelerator verified the presence of A(III) and the absence of A(I), and indicated an azimuthal structure in the jet related to the mass injection locations. Measurements of pressure in the arc chamber and impact pressure in the exhaust jet using a piezocrystal backed by a Plexiglas rod were in good agreement with the electromagnetic thrust model.

Jahn, R. G.↗

A general stagnation-point convective heating equation for arbitrary gas mixtures

The stagnation-point convective heat transfer to an axisymmetric blunt body for arbitrary gases in chemical equilibrium was investigated. The gases considered were base gases of nitrogen, oxygen, hydrogen, helium, neon, argon, carbon dioxide, ammonia, and methane and 22 gas mixtures composed of the base gases. Enthalpies ranged from 2.3 to 116.2 MJ/kg, pressures ranged from 0.001 to 100 atmospheres, and the wall temperatures were 300 and 1111 K. A general equation for the stagnation-point convective heat transfer in base gases and gas mixtures was derived and is a function of the mass fraction, the molecular weight, and a transport parameter of the base gases. The relation compares well with present boundary-layer computer results and with other analytical and experimental results. In addition, the analysis verified that the convective heat transfer in gas mixtures can be determined from a summation relation involving the heat transfer coefficients of the base gases. The basic technique developed for the prediction of stagnation-point convective heating to an axisymmetric blunt body could be applied to other heat transfer problems.

Sutton, K.↗

Thermodynamic properties and theoretical rocket performance of hydrogen to 100,000 K and 1.01325 x 10 to the 8th power N/sq m

The composition and thermodynamic properties were calculated for 100 to 110,000 K and 1.01325 x 10 to the 2nd power to 1.01325 x 10 to the 8th power N/sq m for chemical equilibrium in the Debye-Huckel and ideal-gas approximations. Quantities obtained were the concentrations of hydrogen atoms, protons, free electrons, hydrogen molecules, negative hydrogen ions, hydrogen diatomic molecular ions, and hydrogen triatomic molecular ions, and the enthalpy, entropy, average molecular weight, specific heat at constant pressure, density, and isentropic exponent. Electronically excited states of H and H2 were included. Choked, isentropic, one-dimensional nozzle flow with shifting chemical equilibrium was calculated to the Debye-Huckel and ideal-gas approximations for stagnation temperatures from 2500 to 100,000 K. The mass flow per unit throat area and the sonic flow factor were obtained. The pressure ratio, temperature, velocity, and ideal and vacuum specific impulses at the throat and for pressure ratios as low as 0.000001 downstream were found. For high temperatures at pressures approaching 1.01325 x 10 to the 8th power N/sq m, the ideal-gas approximation was found to be inadequate for calculations of composition, precise thermodynamic properties, and precise nozzle flow. The greatest discrepancy in nozzle flow occurred in the exit temperature, which was as much as 21 percent higher when the Debye-Huckel approximation was used.

Patch, R. W.↗

Hot-gas-side heat transfer with and without film cooling on a simulated nuclear rocket thrust chamber using H2-O2

Heat-transfer coefficients were obtained on a thrust chamber which simulated the geometry of the NERVA nuclear rocket. The tests were performed with and without peripheral film cooling over a chamber pressure range of 1.05 million to 5.84 million newtons per square meter (153 to 847 psia). With no film cooling, the overall axial variation in the value of the correlation coefficient C of the equation (Stanton)* (Prandtl)* to the 0.7ths power = C(Reynolds)* to the -0.2ths power, where * indicates the reference enthalpy condition, was reduced 66 percent when the local diameter in the Reynolds number was replaced by the axial distance from the injector face. The average peak values of C were reduced 25 percent with 2 and 3.75 percent cooling and 50 percent with 7.5 percent cooling.

Quentmeyer, R. J.↗

Thermodynamic and transport properties of frozen and reacting pH2-oH2 mixtures

Application of experimental state data and spectroscopic term values shows that the thermodynamic and transport properties of reacting pH2-oH2 mixtures are considerably different than those of chemically frozen pH2 at temperatures below 300 R. Calculated H-S data also show that radiation-induced pH2-oH2 equilibration at constant enthalpy produces a temperature drop of at least 28 R, corresponding to an ideal shaft work loss of 15% or more for a turbine operating downstream from the point of conversion. Aside from differences in thermodynamic and transport properties, frozen pH2-oH2 mixtures may differ from pure pH2 on a purely hydrodynamical basis.

Carter, H. G.↗

Finite difference solution to the three-dimensional, incompressible thermal energy boundary-layer equation

An implicit numerical method has been adopted for the solution to the three-dimensional, energy boundary-layer equation. The energy equation is written in terms of a dimensionless temperature function, the relative stagnation-enthalpy difference, and transformed by the introduction of a Blasius-type transformation of coordinates as well as dimensionless stream functions. The method is applied to the problem consisting of an infinite cylinder joined with its axis perpendicular to a thin, flat, heated plate. A Prandtl number equal to one is simply considered.

Fillo, J. A.↗

Demonstration of the range over which the Langley Research Center digital computer charring ablation program (CHAP) can be used with confidence: Comparisons of CHAP predictions and test data for three ablation materials

Comparisons of ablation calculations with the charring ablation computer code and ablation test data are presented over a wide range of environmental conditions in air for three materials: low-density nylon phenolic, Avcoat 5026-39HC/G, and a filled silicon elastomer. Heat fluxes considered range from over 500 Btu/sq ft-sec to less than 50 Btu/sq ft-sec. Pressures range from 0.5 atm to .004 atm. Enthalpies range from about 2000 Btu/lb to 18000 Btu/lb. Predictions of recession, pyrolysis penetration, and thermocouple responses are considered. Recession predictions for nylon phenolic are good as steady state is approached, but strongly transient cases are underpredicted. Pyrolysis penetrations and thermocouple responses are very well predicted. Recession amounts for Avcoat and silicone elastomer are less well predicted, although high heat flux cases near steady state are fairly satisfactory. Pyrolysis penetrations and thermocouple responses are very well predicted.

Moyer, C. B.↗