Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electrical signals”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Opto-electronic oscillators having optical resonators

Systems and techniques of incorporating an optical resonator in an optical part of a feedback loop in opto-electronic oscillators. This optical resonator provides a sufficiently long energy storage time and hence to produce an oscillation of a narrow linewidth and low phase noise. Certain mode matching conditions are required. For example, the mode spacing of the optical resonator is equal to one mode spacing, or a multiplicity of the mode spacing, of an opto-electronic feedback loop that receives a modulated optical signal and to produce an electrical oscillating signal.

Yao, Xiaotian Steve↗

Rapid Polymer Sequencer

Method and system for rapid and accurate determination of each of a sequence of unknown polymer components, such as nucleic acid components. A self-assembling monolayer of a selected substance is optionally provided on an interior surface of a pipette tip, and the interior surface is immersed in a selected liquid. A selected electrical field is impressed in a longitudinal or transverse direction at the tip, a polymer sequence is passed through the tip, and a change in an electrical current signal is measured as each polymer component passes through the tip. Each measured change in electrical current signals is compared with a database of reference signals, with each reference signal identified with a polymer component, to identify the unknown polymer component. The tip preferably has a pore inner diameter of no more than about 40 nm and is prepared by heating and pulling a very small section of a glass tubing.

Stolc, Viktor↗

Partial discharge sensor

An approach to detecting partial discharge events involves retrofitting an electrical system to include a capacitive sensor configured to capacitively sense partial discharge events of a component of the electrical system. The capacitive sensor has a first electrical conductor that forms a first terminal of the capacitive sensor, a second electrical conductor that forms a second terminal of the capacitive sensor, and a dielectric that separates the first electrical conductor and the second electrical conductor. The capacitive sensor generates an electrical sensor signal at an output of the capacitive sensor in response to the partial discharge event. The electrical sensor signal is converted to an optical signal and the optical signal is processed to detect an occurrence of the partial discharge event.

Karin, Todd↗

Plasma and electric field measurements of the PVO in the Venus ionosheath

A study of the plasma and electric-field measurements of the PVO in the Venus ionosheath near the terminator region is presented. A drastic decrease of the particle-flux intensity measured with the plasma instrument is encountered in the inner ionosheath before the inbound crossing of the ionopause. The outer boundary of the region of weak plasma fluxes is consistent with the presence of a rarefaction wave as reported previously from the Mariner 5 (Bridge et at., 1967), Venera (Verigin et al., 1978) and PVO (Spenner et al., 1980) plasma measurements in the Venus wake. Near that boundary there are, in addition, appreciable changes in the electric field signals detected with the PVO electric-field detectors. These observations suggest the existence of local plasma-wave activity associated with turbulent flow conditions in that region.

Perez-De-tejada, H.↗

Assessment and Calibration of a Crimp Tool Equipped with Ultrasonic Analysis Features

A method is provided for calibrating ultrasonic signals passed through a crimp formed with respect to a deformable body via an ultrasonically-equipped crimp tool (UECT). The UECT verifies a crimp quality using the ultrasonic signals. The method includes forming the crimp, transmitting a first signal, e.g., a pulse, to a first transducer of the UECT, and converting the first signal, using the first transducer, into a second signal which defines an ultrasonic pulse. This pulse is transmitted through the UECT into the crimp. A second transducer converts the second signal into a third signal, which may be further conditioned, and the ultrasonic signals are calibrated using the third signal or its conditioned variant. An apparatus for calibrating the ultrasonic signals includes a pulse module (PM) electrically connected to the first and second transducers, and an oscilloscope or display electrically connected to the PM for analyzing an electrical output signal therefrom.

Yost, William T.↗

Wireless acoustic-electric feed-through for power and signal transmission

An embodiment provides electrical energy from a source on one side of a medium to a load on the other side of the medium, the embodiment including a first piezoelectric to generate acoustic energy in response to electrical energy from the source, and a second piezoelectric to convert the received acoustic energy to electrical energy used by the load. Other embodiments are described and claimed.

Sherrit, Stewart↗

Backaction-evading receivers with magnetomechanical and electromechanical sensors

Today's mechanical sensors are capable of detecting extremely weak perturbations while operating near the standard quantum limit. However, further improvements can be made in both sensitivity and bandwidth when we reduce the noise originating from the process of measurement itself—the quantum-mechanical backaction of measurement—and go below this ‘standard’ limit, possibly approaching the Heisenberg limit. One of the ways to eliminate this noise is by measuring a quantum nondemolition variable such as the momentum in a free-particle system. Here, we propose and characterize theoretical models for direct velocity measurement that utilize traditional electric and magnetic transducer designs to generate a signal while enabling this backaction evasion. We consider the general readout of this signal via electric or magnetic field sensing by creating toy models analogous to the standard optomechanical position-sensing problem, thereby facilitating the assessment of measurement-added noise. Using simple models that characterize a wide range of transducers, we find that the choice of readout scheme—voltage or current—for each mechanical detector configuration implies access to either the position or velocity of the mechanical subsystem. This in turn suggests a path forward for key fundamental physics experiments such as the direct detection of dark matter particles. Published by the American Physical Society 2024

74 ATOMIC AND MOLECULAR PHYSICS↗

Aircraft measurement of electric field - Self-calibration

Aircraft measurement of electric fields is difficult as the electrically conducting surface of the aircraft distorts the electric field. Calibration requires determining the relations between the undistorted electric field in the absence of the vehicle and the signals from electric field meters that sense the local distorted fields in their immediate vicinity. This paper describes a generalization of a calibration method which uses pitch and roll maneuvers. The technique determines both the calibration coefficients and the direction of the electric vector. The calibration of individual electric field meters and the elimination of the aircraft's self-charge are described. Linear combinations of field mill signals are examined and absolute calibration and error analysis are discussed. The calibration method was applied to data obtained during a flight near thunderstorms.

Winn, W. P.↗

Demand Response in Residential Energy Code: Technical Brief

As buildings account for over 75% of U.S. electricity use, effectively managing their loads can greatly facilitate the transition towards a clean, reliable grid. Grid-interactive efficient buildings (GEBs) combine efficiency and demand flexibility with smart technologies and communication to provide occupant comfort and productivity while serving the grid as a distributed energy resource (DER). In turn, GEBs can play a key role in ensuring access to an affordable, reliable, sustainable, and modern U.S. electric power system. Their national adoption could provide $\$$100-200 billion in U.S. electric power system cost savings over the next two decades. The associated reduction in CO 2 emissions is estimated at 6% per year by 2030 (DOE 2021). Building codes represent standard design practice in the construction industry and continually evolve to include advanced technologies and innovative practices. Historically, national model energy codes establish minimum efficiency requirements for new construction (ICC 2020). Expanding codes to support GEB capabilities is a pivotal step towards realizing demand flexibility in support of a clean grid by addressing capabilities to improve interoperability between smart building systems, the grid, and renewable energy resources. Realizing GEBs requires buildings with automated demand response (DR) capabilities that enable standardized communication with or control of, subject to explicit consumer consent, energy smart appliances or home energy management systems. This is achieved through direct or indirect (i.e., via an aggregator) communication between appliances and the electric grid. Energy codes can also support DR communication standardization and advance the deployment of building-integrated DERs such as energy storage, generation, and electric vehicles (EVs). Incorporating automated DR capabilities in energy codes provides many benefits to the consumers. Specifically, it aligns building electric load demand with intermittent renewable energy source availability, decreases peak load on the electric grid, allows buildings to respond to utility price signals, supports electrical network reliability and market growth of products and processes aligned with clean economic growth. The incorporation of DR into the model residential energy codes was considered for both the 2021 and 2024 International Energy Conservation Code (IECC) code development cycles. The approved DR measures in the 2021 cycle were removed in response to appeals (ICC 2020). Updated language was presented for consideration again for the 2024 IECC, where it was negotiated and again approved, and again removed in response to appeals (ICC 2024). This resulted in many sections, including sections on demand responsive controls, being moved to the credits options or an appendix as a voluntary application. This technical brief updates the proposed DR components such that they can be considered by states and local governments for direct incorporation into their codes, as well as for future IECC energy code development. The proposal refinements are intended to support consistency in approach and provide a degree of certainty for building owners, designers, contractors, manufacturers, and building and fire safety professionals. The scope of this technical brief includes three strategies for DR in residential buildings: 1) smart thermostats with demand-responsive control, 2) electric water heating incorporating demand-responsive controls and communication and 3) grid Integrated solar and energy storage systems.

2021 IECC↗

Monolithic Optoelectronic Integrated Circuit

Monolithic optoelectronic integrated circuit (OEIC) receives single digitally modulated input light signal via optical fiber and converts it into 16-channel electrical output signal. Potentially useful in any system in which digital data must be transmitted serially at high rates, then decoded into and used in parallel format at destination. Applications include transmission and decoding of control signals to phase shifters in phased-array antennas and also communication of data between computers and peripheral equipment in local-area networks.

Bhasin, Kul B.↗

Developing a Lightning All-Clear Signal for the Savannah River Site

Lightning safety is a major concern at the Savannah River Site (SRS). Notifications are provided when 3-strikes occur onsite within a 15-minute period. It is generally left up to individual contractors at SRS to determine when it is safe for workers to return to outside work, generally following a 3-hour period of no lightning, after the last lightning strike occurs. This work tries to improve safe return to work decisions by developing a reliable all-clear signal using an electric field mill. The best signal used thresholds from multiple electric field values to provide an average delay for return to work of 2 hours and 13 minutes. This average was heavily influenced by lingering storms in the area or missing data from power or network outages. One event out of 98 signaled the all-clear prior to another event occurring less than 60 minutes later. Regardless, 62% of the all clear signals had delay times less than the mean and 72% had delay times less than the current 3-hour delay after the last strike. This provides better worker safety for returning to work than 30 minutes after the last lightning strike (e.g. OSHA Lightning Safety) and improves the delay time from the current 3-hour delay.

Noble, Stephen [Savannah River National Laboratory↗

Study of a Solar Sensor for use in Space Vehicle Orientation Control Systems

The solar sensor described herein may be used for a variety of space operations requiring solar orientation. The use of silicon solar cells as the sensing elements provides the sensor with sufficient capability to withstand the hazards of a space environment. A method of arranging the cells in a sensor consists simply of mounting them at a large angle to the base. The use of an opaque shield placed between the cells and perpendicular to the base enhances the small-angle sensitivity while adding slightly to the bulk of the sensor. The difference in illumination of these cells as the result of an oblique incidence of the light rays from the reference source causes an electrical error signal which, when used in a battery-bridge circuit, requires a minimum of electrical processing for use in a space-vehicle orientation control system. An error which could occur after prolonged operation of the sensor is that resulting from asymmetrical aging of opposite cells. This could be periodically corrected with a balance potentiometer. A more routine error in the sensor is that produced by reflected earth radiation. This error may be eliminated over a large portion of the operation time by restricting the field of view and, consequently, the capture capability. A more sophisticated method of eliminating this error is to use separate sensors, for capture and fine pointing, along with a switching device. An experimental model has been constructed and tested to yield an output sensitivity of 1.2 millivolts per second of arc with a load resistance of 1,000 ohms and a reference light source of approximately 1,200 foot-candles delivered at the sensor.

Spencer, Paul R.↗

Electricity Pricing aware Deep Reinforcement Learning based Intelligent HVAC Control

Recently, deep reinforcement learning (DRL) based intelligent control of Heating, Ventilation, and Air Conditioning (HVAC) has gained a lot of attention due to DRL's ability to optimally control HVAC for minimizing operational cost while maintaining resident's comfort. The success of such DRL-based techniques largely depends on the articulation of the problem in terms of states, actions, and reward function. Inclusion of the electricity pricing information in the problem formulation can play an important role in saving the cost of HVAC operation. However, less attention has been given in the literature on formulating well-crafted state features based on electricity pricing. In this work, we propose an approach for training the DRL model with a specific focus on feature engineering based on electricity pricing. During training, we generate random but sufficiently realistic electricity price signals so that the pre-trained DRL model is robust and adaptive to the dynamic and variable electricity prices. The validation results are encouraging and show the potential of ≈12%-15% savings in the one day cost of HVAC operation, proving the usefulness of including electricity pricing related features as state features.

Kurte, Kuldeep↗

Fiber optic accelerometer

Low-cost, rugged lightweight accelerometer has been developed that converts mechanical motion into digitized optical outputs and is immune to electromagnetic and electrostatic interferences. Instrument can be placed in hostile environment, such as engine under test, and output led out through miscellany of electrical fields, high temperatures, etc., by optic fiber cables to benign environment of test panel. There, digitized optical signals can be converted to electrical signals for use in standard electrical equipment or used directly in optical devices, such as optical digital computer.

August, R. R.↗

SiC Multi-Chip Power Modules as Power-System Building Blocks

The term "SiC MCPMs" (wherein "MCPM" signifies "multi-chip power module") denotes electronic power-supply modules containing multiple silicon carbide power devices and silicon-on-insulator (SOI) control integrated-circuit chips. SiC MCPMs are being developed as building blocks of advanced expandable, reconfigurable, fault-tolerant power-supply systems. Exploiting the ability of SiC semiconductor devices to operate at temperatures, breakdown voltages, and current densities significantly greater than those of conventional Si devices, the designs of SiC MCPMs and of systems comprising multiple SiC MCPMs are expected to afford a greater degree of miniaturization through stacking of modules with reduced requirements for heat sinking. Moreover, the higher-temperature capabilities of SiC MCPMs could enable operation in environments hotter than Si-based power systems can withstand. The stacked SiC MCPMs in a given system can be electrically connected in series, parallel, or a series/parallel combination to increase the overall power-handling capability of the system. In addition to power connections, the modules have communication connections. The SOI controllers in the modules communicate with each other as nodes of a decentralized control network, in which no single controller exerts overall command of the system. Control functions effected via the network include synchronization of switching of power devices and rapid reconfiguration of power connections to enable the power system to continue to supply power to a load in the event of failure of one of the modules. In addition to serving as building blocks of reliable power-supply systems, SiC MCPMs could be augmented with external control circuitry to make them perform additional power-handling functions as needed for specific applications: typical functions could include regulating voltages, storing energy, and driving motors. Because identical SiC MCPM building blocks could be utilized in a variety of ways, the cost and difficulty of designing new, highly reliable power systems would be reduced considerably. Several prototype DC-to-DC power-converter modules containing SiC power-switching devices were designed and built to demonstrate the feasibility of the SiC MCPM concept. In anticipation of a future need for operation at high temperature, the circuitry in the modules includes high-temperature inductors and capacitors. These modules were designed to be stacked to construct a system of four modules electrically connected in series and/or parallel. The packaging of the modules is designed to satisfy requirements for series and parallel interconnection among modules, high power density, high thermal efficiency, small size, and light weight. Each module includes four output power connectors two for serial and two for parallel output power connections among the modules. Each module also includes two signal connectors, electrically isolated from the power connectors, that afford four zones for signal interconnections among the SOI controllers. Finally, each module includes two input power connectors, through which it receives power from an in-line power bus. This design feature is included in anticipation of a custom-designed power bus incorporating sockets compatible with snap-on type connectors to enable rapid replacement of failed modules.

Lostetter, Alexander↗

Development of the Nano-HEB Array for Low-Background Far-IR Applications

We present an overview of the recent progress made in the development of a far-IR array of ultrasensitive hot-electronnanobolometers (nano-HEB) made from thin titanium (Ti) films. We studied electrical noise, signal and noisebandwidth, single-photon detection, optical noise equivalent power (NEP), and a microwave SQUID (MSQUID) basedfrequency domain multiplexing (FDM) scheme. The obtained results demonstrate the very low electrical NEP down to1.5x10-(sup 2)? W/Hz(sup 1)/(sup 2) at 50 mK determined by the dominating phonon noise. The NEP increases with temperature as ~ T(sup 3)reaching ~ 10-(sup 1)? W/Hz(sup 1)/(sup 2) at the device critical temperature TC = 330-360 mK. Optical NEP = 8.6x10-(sup 1)? W/Hz(sup 1)/(sup 2) at 357mK and 1.4x10-(sup 1)? W/Hz(sup 1)/(sup 2) at 100 mK respectively, agree with thermal and electrical data. The optical couplingefficiency provided by a planar antenna was greater than 50%. Single 8-?m photons have been detected for the first timeusing a nano-HEB operating at 50-200 mK thus demonstrating a potential of these detectors for future photon-countingapplications in mid-IR and far-IR. In order to accommodate the relatively high detector speed (~ ?s at 300 mK, ~ 100 ?sat 100 mK), an MSQUID based FDM multiplexed readout with GHz carrier frequencies has been built. Both the readoutnoise ~ 2 pA/Hz(sup 1)/(sup 2) and the bandwidth > 150 kHz are suitable for nano-HEB detectors.

single-photon↗

Robot gripper

An electronic force-detecting robot gripper for gripping objects and attaching to an external robot arm is disclosed. The gripper comprises motor apparatus, gripper jaws, and electrical circuits for driving the gripper motor and sensing the amount of force applied by the jaws. The force applied by the jaws is proportional to a threshold value of the motor current. When the motor current exceeds the threshold value, the electrical circuits supply a feedback signal to the electrical control circuit which, in turn, stops the gripper motor.

Webb, Winston S.↗

Measurements of rain effects on an 18-GHz dual-polarized propagation link

The paper presents highlights of rain attenuation and depolarization data collected between August 1972 and March 1974 in an experimental setup consisting of a 1.43-km line-of-sight path with 1.22-m diam dual-polarized parabolic reflector antennas at each end. The antennas used question-mark mounted scalar feeds oriented to transmit or receive linearly polarized 17.65-GHz signals having electric field vectors at +45 deg and -45 deg from the vertical. Rain data were collected and analyzed for 24 individual storms in which the rain rate exceeded 10 mm/hr. Received signal levels were sampled once each second and stored by a small digital computer which controlled the experiment and performed preliminary data processing. The results are compared with a theoretical model presented by Wiley et al. (1974). Experimental cross-polarization isolation data are found to agree well with theoretical values, especially at high rain rates where the antenna effects are the least significant.

Bostian, C. W.↗