Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electric Arc”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Quantitative Radiation Thermometry Using Commercially Available High-Speed Video Cameras

In order to understand the risk posed to astronauts by electric arc-generated particles, high-speed, high-resolution, quantitative thermal imaging was needed. The measurement requirements appeared to be beyond the capabilities of commercial thermal imaging systems, but the particles were known to have a significant amount of emission in the visible spectrum. This led to the use of commercially available, high-speed video cameras as imaging radiometers. Measured particle temperatures were consistent with predictions and other measurement data. The optical temperature measurement method, results, and conclusions are presented, along with recommendations for further work.

Thermal imaging↗

Measurement of Test Time in the NASA Ames EAST Expansion Cone Facility in Entry 63 and Possible Techniques for Increasing Test Time

The Ames EAST facility and its modes of operation (expansion tube, expansion cone) are described. A buffer section may or may not be used between the driver and the driven tube. Previous expansion tube (without the cone) entries are reviewed. Test times of 4 to 5 microsec were achieved at shock speeds up to 11 km/s. The test conditions and results of the present entry (entry 63) (with the cone) are given. Test times were found to correlate roughly with the density ratio across the buffer gas - driven gas or driver - driven gas interface. Tests with a 12 inch long conical driver without a buffer yielded three runs with test times of ~8 km/s and 3 runs with test times of 4 to 6 microsecs. With a buffer, test times for 4 runs of ~9 microsecs and for 2 runs of 3 to 6 microsecs were obtained. Adding argon to the buffer was found not to improve the test time. Tests with a 30 inch long driver without a buffer yielded test times of 14+, ~10, 7.5 (2 runs) and 5.5 (2 runs) microsecs. Based on one shot, data for the 30 inch driver suggests that test times up to ~14 microseconds could be obtained. The repeatability of that shot, of course, must be established. Suggestions are given to increase test times further.

Electric arc shock tube↗

Design and Fabrication of the Mu2e Cryogenic Distribution System

The muon-to-electron conversion (Mu2e) experiment at Fermilab will be used to search for the charged lepton flavor-violating conversion of muons to electrons in the field of an atomic nucleus. The Mu2e experiment is currently in the design and construction stage and is expected to begin operations in 2022. The Mu2e experiment uses four large superconducting solenoid magnets including a Production Solenoid (PS), an Upstream and Downstream Transport Solenoid (TSu and TSd) and a Detector Solenoid (DS). This paper will focus on the cryogenic distribution system for these four solenoid magnets. Liquid helium will be supplied from two re-purposed Tevatron satellite refrigerators. A large cryogenic distribution box (DB) is located in the Mu2e building to distribute the required cryogens to each of the four solenoid magnets. Each solenoid magnet will have a dedicated transfer line and cryogenic feed box (FB). The solenoid magnets each require two liquid helium circuits and two liquid nitrogen circuits. The most unique feature about this cryogenic system is that the assemblies for the start of the superconducting portion of the power leads are mounted in feed boxes that are in the range of 23 m to 31 m away from the solenoid magnets. The cryogenic feed boxes are located remotely to provide protection from radiation damage and high magnetic fields. The power leads are NbTi superconducting cable stabilized with high conductivity aluminum. The 6061-T6 aluminum grade was selected for the transfer line piping so that the piping would thermally contract at the same rate as the power lead. A major concern for this transfer line is that a small helium leak could create an electric discharge arc due to the Paschen effect. This paper includes a description of the design features and testing done to ensure that the power leads are protected from the Paschen effect while still being adequately cooled to liquid helium temperatures.

43 PARTICLE ACCELERATORS↗

Electric field oscillations measured near an auroral arc

A sounding rocket, launched into the expansive phase of an auroral substorm, measured bursts of electric field oscillations with a typical period of one second and a magnitude exceeding 20 mV/m. The oscillation appear to be due to an MHD wave propagating along the magnetic field. The bursts were observed as the sounding rocket passed over the southern border of an auroral arc. The southern border coincided with an increase in 1-5 keV electron flux and an increase in field-aligned current.

Kintner, P. M.↗

Why does the perpendicular electric field increase at the edge of auroral arcs?

Radar, rocket and satellite measurements often indicate that there is a strong increase and subsequent decrease in the perpendicular electric field when traversing one edge of an auroral arc. The analysis of rocket measurements, presented here, shows that above an auroral arc there is a small gradient in the electric field due to polarization effects in the ionosphere, but that the strong increase at the edge of the arc can only be explained if the field-aligned currents associated with the arc are taken into account.

Bruening, K.↗

Anticipated Electrical Environment Within Permanently Shadowed Lunar Craters

Shadowed locations ncar the lunar poles arc almost certainly electrically complex regions. At these locations near the terminator, the local solar wind flows nearly tangential to the surface and interacts with large-scale topographic features such as mountains and deep large craters, In this work, we study the solar wind orographic effects from topographic obstructions along a rough lunar surface, On the leeward side of large obstructions, plasma voids are formed in the solar wind because of the absorption of plasma on the upstream surface of these obstacles, Solar wind plasma expands into such voids) producing an ambipolar potential that diverts ion flow into the void region. A surface potential is established on these leeward surfaces in order to balance the currents from the expansion-limited electron and ion populations, Wc find that there arc regions ncar the leeward wall of the craters and leeward mountain faces where solar wind ions cannot access the surface, leaving an electron-rich plasma previously identified as an "electron cloud." In this case, some new current is required to complete the closure for current balance at the surface, and we propose herein that lofted negatively charged dust is one possible (nonunique) compensating current source. Given models for both ambipolar and surface plasma processes, we consider the electrical environment around the large topographic features of the south pole (including Shoemaker crater and the highly varied terrain near Nobile crater), as derived from Goldstone radar data, We also apply our model to moving and stationary objects of differing compositions located on the surface and consider the impact of the deflected ion flow on possible hydrogen resources within the craters

Farrell, W. M.↗

Auroral vector electric field and particle comparisons. II - Electrodynamics of an arc

The paper reports the results of energetic auroral electron and vector electric field measurements taken near and above a discrete auroral form and discusses their electrodynamic implications. Height-integrated Hall and Pedersen conductivities are computed in a quantitative fashion along the rocket payload trajectory. These conductivities, together with the electric fields, are used to describe the local auroral electrojet current system and to demonstrate an inverse relationship between the local electric field intensity and the height-integrated Pedersen conductivity. An analysis is presented of the divergence of both the electric field and the horizontal current as an effort to infer space charge densities and magnetic-field-aligned electrical currents near an auroral arc.

Evans, D. S.↗

Arc Flash Evaluation Poster

Arc flash evaluation is a key aspect of assessing the safety of an electrical system. An arc flash occurs when a short circuit results in large amounts of unexpected current in a conductor leading to a massive release of energy. By conducting an arc flash evaluation engineers are able to design safer systems and determine the level of protective equipment that a worker needs to wear in order to survive an arc flash incident.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Toward understanding the conical arc-chamber driver

The mechanical and electrical characteristics of the conical arc-chamber driver and the 1450-microfarad capacitor bank are described. The system dynamic performance can be approximated by a second-order nonlinear equation. The discharge of the capacitor bank into the conical arc-chamber was investigated at a variety of initial conditions. Details of the discharge are explained and compared for typical performance with both hydrogen and helium arc-chamber gases. At peak current the hydrogen plasma resistivity is significantly higher than that of the helium plasma and this, in part, accounts for the better shock speed performance with hydrogen. The lower melting and boiling point exploding wires of aluminum, copper, and stainless steel produced higher shock speed performance than the apparently nonexploding tungsten wire.

Livingston, F. R.↗

A Co-Registered In-Situ and Ex-Situ Dataset of Electrical, Acoustic, and CT Characteristics from Wire Arc Additive Manufacturing Process

Recent progress in sensing techniques and data analytics tools have significantly accelerated the development of Wire Arc Additive Manufacturing (WAAM) systems. This data centric approach emphasizes leveraging available data throughout the production process to optimize performance. Integration of extensive data analysis provides the opportunity to improve precision, reduce waste, and enhance the quality of produced parts. This method relies on AI/ML models and optimization techniques, which are developed using the data collected from various sources, including in-situ sensors, ex-situ imaging, and manufacturing process parameters. The quality and diversity of this data, along with the alignment between different data streams (achieved through spatiotemporal registration) are critical for the successful development of AI/ML and optimization models. In this work, we present a spatiotemporally registered dataset generated during the WAAM process of deposition of a rectangular block. The dataset includes the comprehensive description of deposition process, process parameters, in-situ collected welding characteristics, acoustic data, and X-Ray Computed Tomography analysis data for the build. Dataset A Co-Registered In-Situ and Ex-Situ Dataset of Electrical, Acoustic, and CT Characteristics from Wire Arc Additive Manufacturing Process has arisen under UT-Battelle, LLC’s Prime Contract No. DE-AC05-00OR22725 with the U.S. Department of Energy (DOE) to manage and operate the Oak Ridge National Laboratory. UT-Battelle, LLC will not assert any rights under United States law or under the Prime Contract it has in the dataset against any user of the dataset, including any copyrights or patent rights. UT-Battelle, LLC requests that attribution to the dataset is provided as academically appropriate.

42 ENGINEERING↗

Rocket observations at the northern edge of the eastward electrojet

The paper discusses a Nike-Tomahawk rocket launched north over quiet, late evening auroral arcs in March 1975. A northward magnetic disturbance was observed on the ground under the rocket trajectory; south of the arcs the northward electric field was 60 mV/m, indicating strong westward plasma flow. An eastward electrojet current layer was penetrated in the upward flight, and precipitating electrons were observed over each arc. Using the observed electron flux and a model of the ionosphere, the Hall and Pedersen conductivities were calculated which were used to compute the eastward and northward components of the horizontal ionospheric currents. The joule power decreased abruptly in the auroral arcs, as the precipitating electron power increased; the total dissipated power was the same inside the arcs, between them and southward. North of the aurora the electric field and dissipated power remained low; field-aligned currents carried by the observed electrons were about a factor of 3 lower than those inferred from the magnetic field measurements.

Cahill, L. J., Jr.↗

On the anticorrelation of the electric field and peak electron energy within an auroral arc

The present investigation is concerned with an example of a strongly anticorrelated electric field and particle precipitation, taking into account an application of an extended version of the model of Evans et al. (1977) to the data. A striking feature of the data reported is the high degree of anticorrelation between electric field strength and peak precipitating electron energy. A simple model consisting of a constant current traversing a region in which the conductivities increase in proportion to ionospheric energy deposition provides a qualitative explanation of the observations. However, when the effects of neutral winds, ionization transport, Hall currents, and arc motion, and the nonlinearity of the relationship between peak precipitating electron energy and equilibrium are considered, the conclusions become less clear.

Mallinckrodt, A. J.↗

Breakdown characteristics and conditioning of carbon and refractory metal electrodes

High voltage carbon and refractory metal electrodes employed in devices used in space, such as ion thrusters and traveling wave tubes, can be easily damaged by electrical breakdown and arcing events. Modification of the electrode surfaces due to these events can impact the voltage hold off capability of the surfaces, which could lead to additional arcing, further damage, and the potential for device failure. On the cathode-potential surface, the arc energy is deposited by all of the processes at the surface ultimately responsible for net electron emission, such as melting, vapor and particulate formation, sputtering, ion bombardment, etc. On the anode-potential surface, the energy is deposited from the plasma or electron stream that crosses the gap, which causes surface damage by local heating. In spite of this energy dependence on the damage, many systems that use arc discharges characterize the amount of material removed from the surfaces and the lifetime of the device for voltage hold-off by the amount of current that passes through the arc, or the 'Coulomb-rating'. The results of a series of tests that were preformed on the boltage hold off capability and damage to carbon-carbon composite surfaces and molybdenum surfaces due to induced arcing will be presented and discussed. Damage to the surfaces was characterized by the field emission performance after the arc initiation and SEM photographs for the different energy and coulomb-transfer arc conditions. Both conditioning and damage to the surfaces were observed, and will be related to the characteristics of the electrical breakdown.

high voltage breakdown↗

High Voltage Surge Protection by a Varistor-Filled Air Gap

The electric discharge across a varistor granule filled air gap under a fast-rising voltage pulse was investigated for surge protection applications. The effects of temperature and pressure on the arc and the electrical conduction were analyzed by the characteristic changes in voltage waveforms triggered by a fast-rising high voltage pulse. In addition to the gap size, experimental results show that competing mechanisms among arc conduction, conduction through the varistor granule network, thermionic emission from Joule heating at granule-to-granule contact points, and the magnitude of the switching voltage dictate the maximum surge protection voltage for the filled air gap. Experimental evidence indicated that accumulated degradation was created at small contact points between varistor granules by repetitive assaults from longer duration, high voltage pulses. The uniqueness of using varistor over other dielectric granules in an air gap for surge protection is identified and discussed.

36 MATERIALS SCIENCE↗