Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “EXPERIMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Improving a high-efficiency, gated spectrometer for x-ray Thomson scattering experiments at the National Ignition Facility

We are developing x-ray Thomson scattering for applications in implosion experiments at the National Ignition Facility. In particular we have designed and fielded MACS, a high-efficiency, gated x-ray spectrometer at 7.5–10 keV [T. Döppner et al., Rev. Sci. Instrum. 85, 11D617 (2014)]. Here we report on two new Bragg crystals based on Highly Oriented Pyrolytic Graphite (HOPG), a flat crystal and a dual-section cylindrically curved crystal. We have performed in situ calibration measurements using a brass foil target, and we used the flat HOPG crystal to measure Mo K-shell emission at 18 keV in 2nd order diffraction. Such high photon energy line emission will be required to penetrate and probe ultra-high-density plasmas or plasmas of mid-Z elements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A synthetic diagnostic for beam emission spectroscopy in the helically symmetric experiment stellarator

The Helically Symmetric Experiment (HSX) has a number of active spectroscopy diagnostics. Due to the relatively large beam width compared to the plasma minor radius, it is difficult to achieve good spatial resolution at the core of the HSX plasma. This is due to the fact that the optical sightline cuts through many flux surfaces with varying field vectors within the beam. In order to compare the experimental results with theoretical models it is important to accurately model the beam width effects. A synthetic diagnostic has been developed for this purpose. This synthetic diagnostic calculates the effect of spot size and beam width on the measurements of quantities of interest, including radial electric field, flow velocity, and Stark polarization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray transport and radiation response assessment (XTRRA) experiments at the National Ignition Facility

Our team has developed an experimental platform to evaluate the x-ray-generated stress and impulse in materials. Experimental activities include x-ray source development, design of the sample mounting hardware and sensors interfaced to the National Ignition Facility’s diagnostics insertion system, and system integration into the facility. This paper focuses on the X-ray Transport and Radiation Response Assessment (XTRRA) test cassettes built for these experiments. The test cassette is designed to position six samples at three predetermined distances from the source, each known to within ±1% accuracy. Built-in calorimeters give in situ measurements of the x-ray environment along the sample lines of sight. The measured accuracy of sample responses as well as planned modifications to the XTRRA cassette is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical smoothing of laser imprinting in planar-target experiments on OMEGA EP using multi-FM 1-D smoothing by spectral dispersion

Direct-drive ignition on the National Ignition Facility (NIF) requires single-beam smoothing to minimize imprinting of laser nonuniformities that can negatively affect implosion performance. One-dimensional, multi-FM smoothing by spectral dispersion (SSD) has been proposed to provide the required smoothing [Marozas et al., Bull. Am. Phys. Soc. 55, 294 (2010)]. A prototype multi-FM SSD system has been integrated into the NIF-like beamline of the OMEGA EP Laser System. Experiments have been performed to verify the smoothing performance by measuring Rayleigh–Taylor growth rates in planar targets of laser-imprinted and preimposed surface modulations. Multi-FM 1-D SSD has been observed to reduce imprint levels by ∼50% compared to the nominal OMEGA EP SSD system. The experimental results are in agreement with 2-D DRACO simulations using realistic, time-dependent far-field spot-intensity calculations that emulate the effect of SSD.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The charge exchange recombination spectroscopy diagnostic on the upgraded Lithium Tokamak eXperiment (LTX-β)

The Lithium Tokamak eXperiment has undergone an upgrade to LTX-β, a major part of which is the addition of neutral beam injection (NBI). NBI has allowed for a new charge exchange recombination spectroscopy (CHERS) system to be installed in order to measure impurity concentrations, ion temperature, and toroidal velocity. Previously on LTX measuring these parameters relied on passive spectroscopy and inversion techniques and had large uncertainty. The CHERS system has 52 total views, split into four groups of 13, half facing toward the beam and half symmetrically facing away from the beam, so the background non-beam related emission can be simultaneously subtracted. Both sets of views sample a major radius of 27-59 cm, with resolution through the beam of 1.5-2.5 cm. LTX-β is expected to have its magnetic axis near 35 cm, with minor radii of 18-23 cm. Three separate spectrometers will be used for the diagnostic, giving the system great flexibility to simultaneously measure emission from multiple impurity lines. The viewing optics are f/1.8, allowing all of the spectrometers to be fully illuminated. Design and calibration of the system as well as the advantages of various configurations of the spectrometers will be highlighted.

Elliott, Drew↗

Dual-pass upgrade to the Thomson scattering diagnostic on the Prototype-Material Plasma Exposure eXperiment (Proto-MPEX)

The Thomson scattering (TS) diagnostic on the Prototype-Material Plasma Exposure eXperiment has been upgraded to measure electron temperature (T e ) and density (n e ) simultaneously at two axial locations. After the first pass through the vacuum vessel, the exiting laser beamline is re-collimated in the atmosphere and rerouted into the vacuum vessel for the second pass. The upgrade will help diagnose axial T e and n e gradients between the “central chamber” and the target region which are located 1 m and 2.5 m, respectively, downstream from the Helicon radio-frequency source. The TS measurements have given T e ≈ 4–15 eV and n e ≈ 2–4 × 10 19 m -3 at the central chamber and T e ≈ 1–2 eV and n e ≈ 1–2 × 10 19 m -3 at the target region. The upgrade also increases the number of sampling points at the target region from 3 fibers to 5 fibers, measuring 3 cm radially across the plasma column, and 25 fibers in the central chamber, radially spanning 8 cm. The intensified CCD camera is double triggered for each laser pulse in order to measure (1) the TS and laser stray light and (2) the plasma background light that contains nuisance emission lines and bremsstrahlung. Subtracting the background light from the TS photons improves the temperature and density measurements. Details of the diagnostic setup, axial and radial measurements, and areas for further optimization are discussed.

dual-pass Thomson Scattering↗

Cinema:Snap: Real-time tools for analysis of dynamic diamond anvil cell experiment data

We report we developed tools and a workflow for real-time analysis of data from dynamic diamond anvil cell experiments performed at user light sources. These tools allow users to determine the phases of matter observed during the compression of materials in order to make decisions during an experiment to improve the quality of experimental results and maximize the use of scarce experimental facility time. The tools fill a gap in dynamic compression data analysis tools that are real-time, are flexible to the needs of high-pressure scientists, connect to automated processing of results, can be easily incorporated into workflows with existing tools and data formats, and support remote experimental data analysis workflows. Specific analytics developed include novel automated two-peak analysis for overlapping peaks and multiple phases, coordinated views of pressure and temperature values, full-compression contour plots, and configurable views of integrated x-ray diffraction. We present an experimental use case to show how the tools produce real-time analytics that help the scientists revise parameters for the next compression

47 OTHER INSTRUMENTATION↗

High-rate strength response of tantalum from dynamic hole closure experiments

The science and engineering communities have significant interest in experimental platforms to evaluate and improve models for dynamic material deformation. While well-developed platforms exist, there are still gaps to fill for strain and strain rate conditions accessed during impact and other high-rate loading scenarios. To fill one such gap for strength measurements, a platform was recently developed that accesses high strain rate (≥ 10 5 /s) and large strain (≥ 50%) conditions by measuring the transient closure of a cylindrical hole using in situ x-ray imaging. In the work reported here, further refinement of the platform is performed to reduce the potential effects of porosity and anelasticity on the measurement. This helps us to isolate the strength effects that are the focus of the experiment. The updated experimental configuration employs a two-layer flyer design and elongated target to reduce the magnitude of the tensile excursions associated with rarefaction wave interactions. This allows for a more direct assessment of strength models commonly used for dynamic simulations of metals. Here we apply the new technique to well-characterized tantalum material, allowing for a robust connection to other experimental techniques. Deformation localization can be a concern in large strain experiments, and to help inform future use of the experimental platform, we use simulations with a sub-zone treatment of shear banding to explore potential localization behavior. Here we develop and utilize an experimental configuration with improved isolation of strength effects that can be applied to an expanded range of materials.

42 ENGINEERING↗

Soil metabolome response to whole-ecosystem warming at the Spruce and Peatland Responses under Changing Environments experiment

In this study, a suite of complementary environmental geochemical analyses, including NMR and gas chromatography-mass spectrometry (GC-MS) analyses of central metabolites, Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) of secondary metabolites, and lipidomics, was used to investigate the influence of organic matter (OM) quality on the heterotrophic microbial mechanisms controlling peatland CO2, CH4, and CO2:CH4 porewater production ratios in response to climate warming. Our investigations leverage the Spruce and Peatland Responses under Changing Environments (SPRUCE) experiment, where air and peat warming were combined in a whole-ecosystem warming treatment. We hypothesized that warming would enhance the production of plant-derived metabolites, resulting in increased labile OM inputs to the surface peat, thereby enhancing microbial activity and greenhouse gas production. Because shallow peat is most susceptible to enhanced warming, increases in labile OM inputs to the surface, in particular, are likely to result in significant changes to CO2 and CH4 dynamics and methanogenic pathways. In support of this hypothesis, significant correlations were observed between metabolites and temperature consistent with increased availability of labile substrates, which may stimulate more rapid turnover of microbial proteins. An increase in the abundance of methanogenic genes in response to the increase in the abundance of labile substrates was accompanied by a shift toward acetoclastic and methylotrophic methanogenesis. Our results suggest that as peatland vegetation trends toward increasing vascular plant cover with warming, we can expect a concomitant shift toward increasingly methanogenic conditions and amplified climate–peatland feedbacks.

Wilson, Rachel M.↗

Probing the electronic properties of the electrified silicon/water interface by combining simulations and experiments.

Silicon (Si) is broadly used in electrochemical and photoelectrochemical devices, where the capacitive and Faradaic reactions at the Si/water interfaces are critical for signal transduction or noise generation. However, probing the electrified Si/water interface at the microscopic level remains a challenging task. Here we focus on hydrogenated Si surfaces in contact with water, relevant to transient electronics and photoelectrochemical modulation of biological cells and tissues. We show that by carrying out first principles molecular dynamics simulations of the Si(100)/water interface in the presence of an electric field we can realistically correlate the computed flat-band potential and tunneling current images at the interface with experimentally measured capacitive and Faradaic currents. Specifically, we validate our simulations in the presence of bias by performing pulsed chronoamperometry measurements on Si wafers in solution. Consistent with prior experiments, our measurements and simulations indicate the presence of voltage-dependent capacitive currents at the interface. We also find that Faradaic currents are weakly dependent on the applied bias, which we relate to surface defects present in newly prepared samples.

Ye, Zifan↗

Directional resolution of dish antenna experiments to search for WISPy dark matter

Dark matter consisting of very light and very weakly interacting particles such as axions, axion-like particles and hidden photons could be detected using reflective surfaces. On such reflectors some of the dark matter particles are converted into photons and, given a suitable geometry, concentrated on the detector. This technique offers sensitivity to the direction of the velocity of the dark matter particles. In this note we investigate how far spherical mirrors can concentrate the generated photons and what this implies for the resolution in directional detection as well as the sensitivity of discovery experiments not aiming for directional resolution. Finally we discuss an improved setup using a combination of a reflecting plane with focussing optics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The MICE Muon Beam on ISIS and the beam-line instrumentation of the Muon Ionization Cooling Experiment

The international Muon Ionization Cooling Experiment (MICE), which is under construction at the Rutherford Appleton Laboratory (RAL), will demonstrate the principle of ionization cooling as a technique for the reduction of the phase-space volume occupied by a muon beam. Ionization cooling channels are required for the Neutrino Factory and the Muon Collider. MICE will evaluate in detail the performance of a single lattice cell of the Feasibility Study 2 cooling channel. The MICE Muon Beam has been constructed at the ISIS synchrotron at RAL, and in MICE Step I, it has been characterized using the MICE beam-instrumentation system. In this paper, the MICE Muon Beam and beam-line instrumentation are described. The muon rate is presented as a function of the beam loss generated by the MICE target dipping into the ISIS proton beam. For a 1 V signal from the ISIS beam-loss monitors downstream of our target we obtain a 30 KHz instantaneous muon rate, with a neglible pion contamination in the beam.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Experiments on the synthesis of superheavy nuclei Fl 284 and Fl 285 in the Pu 239 , 240 + Ca 48 reactions

Irradiations of 239 Pu and 240 Pu targets with 48Ca beams aimed at the synthesis of Z=114 flerovium isotopes were performed at the Dubna Gas Filled Recoil Separator. A new spontaneously fissioning (SF) isotope 284 Fl was produced for the first time in the 240 Pu+ 48 Ca (250 MeV) and 239 Pu+ 48 Ca (245 MeV) reactions. The cross section of the 239 Pu( 48 Ca,3n) 284 Fl reaction channel was about 20 times lower than predicted by theoretical models and about 50 times lower than the maximum fusion-evaporation cross section for the 3n and 4n channels measured in the 244 Pu+ 48 Ca reaction. In the 240 Pu+ 48 Ca experiment, performed at 245 MeV in order to maximize the 3n-evaporation channel, three decay chains of 285 Fl were detected. The α-decay energy of 285 Fl was measured for the first time and decay properties of its descendants 281 Cn, 277 Ds, 273 Hs, 269 Sg, and 265 Rf were determined with higher accuracy. The assignment of SF events observed during the irradiation of the 240 Pu target with a 250 MeV 48 Ca beam to 284 Fl decay is presented and discussed. The cross sections at both 48 Ca energies are similar and exceed that observed in the reaction with the lighter isotope 239 Pu by a factor of 10. In conclusion, the decay properties of the synthesized nuclei and their production cross sections indicate a rapid decrease of stability of superheavy nuclei as the neutron number decreases from the predicted magic neutron number N = 184.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Electron radiated power in cyclotron radiation emission spectroscopy experiments

The recently developed technique of Cyclotron Radiation Emission Spectroscopy (CRES) uses frequency information from the cyclotron motion of an electron in a magnetic bottle to infer its kinetic energy. Here we derive the expected radio-frequency signal from an electron in a waveguide CRES apparatus from first principles. We demonstrate that the frequency-domain signal is rich in information about the electron's kinematic parameters and extract a set of measurables that in a suitably designed system are sufficient for disentangling the electron's kinetic energy from the rest of its kinematic features. This lays the groundwork for high-resolution energy measurements in future CRES experiments, such as the Project 8 neutrino mass measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Constraints on dark photons and axionlike particles from the SuperCDMS Soudan experiment

We present an analysis of electron recoils in cryogenic germanium detectors operated during the SuperCDMS Soudan experiment. The data are used to set new constraints on the axioelectric coupling of axion-like particles and the kinetic mixing parameter of dark photons, assuming the respective species constitutes all of the galactic dark matter. This study covers the mass range from 40 eV/$c^2$ to 500 eV/$c^2$ for both candidates, excluding previously untested parameter space for masses below ~1 keV/$c^2$. For the kinetic mixing of dark photons, values below $10^{-15}$ are reached for particle masses around 100 eV/$c^2$; for the axioelectric coupling of axion-like particles, values below $10^{-12}$ are reached for particles with masses in the range of a few-hundred eV/$c^2$.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effective field theory interactions for liquid argon target in DarkSide-50 experiment

We reanalize data collected with the DarkSide-50 experiment and recently used to set limits on the spin-independent interaction rate of weakly interacting massive particles (WIMPs) on argon nuclei with an effective field theory framework. The dataset corresponds to a total (16660 ± 270) kg d exposure using a target of low-radioactivity argon extracted from underground sources. We obtain upper limits on the effective couplings of the 12 leading operators in the nonrelativistic systematic expansion. For each effective coupling we set constraints on WIMP-nucleon cross sections, setting upper limits between 2.4×10-45 cm2 and 2.3×10-42 cm2 (8.9 ×10-45 cm2 and 6.0 ×10-42 cm2) for WIMPs of mass of 100 GeV/c2 (1000 GeV/c2) at 90% confidence level.

Agnes, P↗