Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ERROR DETECTING CODE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Practical applications of model checking in the finnish nuclear industry - 281

Model checking is a powerful, formal, computer-assisted verification method that can be used to prove that a model of a (hardware or software) system fulfills stated properties. When used right, model checking can prove the correctness of instrumentation and control (I and C) system application logic, be it a software or a field-programmable gate array (FPGA) based design. The verified properties can also address unwanted functionality, making model checking a very effective method for analyzing spurious actuation. Despite the benefits, model checking is still not widely adopted in the verification of I and C systems, one exception being the Finnish nuclear industry. Since 2008, VTT has applied model checking in practical customer work related to the Olkiluoto 3 EPR, Loviisa 1 and 2 VVER-440, and Hanhikivi 1 AES-2006 nuclear power plants, on commission from either the regulator or the utilities. In this paper, we look at how the method has been used in each of these three projects. We also introduce a user-friendly, graphical modelling tool called MODCHK. We then present an overall view of the design issues detected during nine years of customer work, and one practical example. The 100% coverage means that the design errors that are found often relate to scenarios that are otherwise hard to account for (e.g., exact timing of events, or improper operator actions). (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SU-F-P-07: Applying Failure Modes and Effects Analysis to Treatment Planning System QA

Purpose: A small-scale implementation of Failure Modes and Effects Analysis (FMEA) for treatment planning system QA by utilizing methodology of AAPM TG-100 report. Methods: FMEA requires numerical values for severity (S), occurrence (O) and detectability (D) of each mode of failure. The product of these three values gives a risk priority number (RPN). We have implemented FMEA for the treatment planning system (TPS) QA for two clinics which use Pinnacle and Eclipse TPS. Quantitative monthly QA data dating back to 4 years for Pinnacle and 1 year for Eclipse have been used to determine values for severity (deviations from predetermined doses at points or volumes), and occurrence of such deviations. The TPS QA protocol includes a phantom containing solid water and lung- and bone-equivalent heterogeneities. Photon and electron plans have been evaluated in both systems. The dose values at multiple distinct points of interest (POI) within the solid water, lung, and bone-equivalent slabs, as well as mean doses to several volumes of interest (VOI), have been re-calculated monthly using the available algorithms. Results: The computed doses vary slightly month-over-month. There have been more significant deviations following software upgrades, especially if the upgrade involved re-modeling of the beams. TG-100 guidance and the data presented here suggest an occurrence (O) of 2 depending on the frequency of re-commissioning the beams, severity (S) of 3, and detectability (D) of 2, giving an RPN of 12. Conclusion: Computerized treatment planning systems could pose a risk due to dosimetric errors and suboptimal treatment plans. The FMEA analysis presented here suggests that TPS QA should immediately follow software upgrades, but does not need to be performed every month.

60 APPLIED LIFE SCIENCES↗

Analyzing rocket plume spectral data with neural networks

The Optical Plume Anomaly Detection (OPAD) system is under development to provide early-warning failure detection in support of ground-level testing of the Space Shuttle Main Engine (SSME). Failure detection is to be achieved through the acquisition of spectrally resolved plume emissions and subsequent identification of abnormal levels indicative of engine corrosion or component failure. Two computer codes (one linear and the other non-linear) are used by the OPAD system to iteratively determine specific element concentrations in the SSME plume, given emission intensity and wavelength information. Since this analysis is extremely labor intensive, a study was initiated to develop neural networks that would model the 'inverse' of these computer codes. Optimally connected feed-forward networks with imperceptible prediction error have been developed for each element modeled by the linear code, SPECTRA4. Radial basis function networks were developed for the non-linear code, SPECTRA5, and predict combustion temperature in addition to element concentrations.

Whitaker, Kevin W.↗

Online 3D EPID-based dose verification: Proof of concept

Purpose: Delivery errors during radiotherapy may lead to medical harm and reduced life expectancy for patients. Such serious incidents can be avoided by performing dose verification online, i.e., while the patient is being irradiated, creating the possibility of halting the linac in case of a large overdosage or underdosage. The offline EPID-based 3D in vivo dosimetry system clinically employed at our institute is in principle suited for online treatment verification, provided the system is able to complete 3D dose reconstruction and verification within 420 ms, the present acquisition time of a single EPID frame. It is the aim of this study to show that our EPID-based dosimetry system can be made fast enough to achieve online 3D in vivo dose verification. Methods: The current dose verification system was sped up in two ways. First, a new software package was developed to perform all computations that are not dependent on portal image acquisition separately, thus removing the need for doing these calculations in real time. Second, the 3D dose reconstruction algorithm was sped up via a new, multithreaded implementation. Dose verification was implemented by comparing planned with reconstructed 3D dose distributions delivered to two regions in a patient: the target volume and the nontarget volume receiving at least 10 cGy. In both volumes, the mean dose is compared, while in the nontarget volume, the near-maximum dose (D2) is compared as well. The real-time dosimetry system was tested by irradiating an anthropomorphic phantom with three VMAT plans: a 6 MV head-and-neck treatment plan, a 10 MV rectum treatment plan, and a 10 MV prostate treatment plan. In all plans, two types of serious delivery errors were introduced. The functionality of automatically halting the linac was also implemented and tested. Results: The precomputation time per treatment was ∼180 s/treatment arc, depending on gantry angle resolution. The complete processing of a single portal frame, including dose verification, took 266 ± 11 ms on a dual octocore Intel Xeon E5-2630 CPU running at 2.40 GHz. The introduced delivery errors were detected after 5–10 s irradiation time. Conclusions: A prototype online 3D dose verification tool using portal imaging has been developed and successfully tested for two different kinds of gross delivery errors. Thus, online 3D dose verification has been technologically achieved.

60 APPLIED LIFE SCIENCES↗

A Lightning Channel Retrieval Algorithm for the North Alabama Lightning Mapping Array (LMA)

A new multi-station VHF time-of-arrival (TOA) antenna network is, at the time of this writing, coming on-line in Northern Alabama. The network, called the Lightning Mapping Array (LMA), employs GPS timing and detects VHF radiation from discrete segments (effectively point emitters) that comprise the channel of lightning strokes within cloud and ground flashes. The network will support on-going ground validation activities of the low Earth orbiting Lightning Imaging Sensor (LIS) satellite developed at NASA Marshall Space Flight Center (MSFC) in Huntsville, Alabama. It will also provide for many interesting and detailed studies of the distribution and evolution of thunderstorms and lightning in the Tennessee Valley, and will offer many interesting comparisons with other meteorological/geophysical wets associated with lightning and thunderstorms. In order to take full advantage of these benefits, it is essential that the LMA channel mapping accuracy (in both space and time) be fully characterized and optimized. In this study, a new revised channel mapping retrieval algorithm is introduced. The algorithm is an extension of earlier work provided in Koshak and Solakiewicz (1996) in the analysis of the NASA Kennedy Space Center (KSC) Lightning Detection and Ranging (LDAR) system. As in the 1996 study, direct algebraic solutions are obtained by inverting a simple linear system of equations, thereby making computer searches through a multi-dimensional parameter domain of a Chi-Squared function unnecessary. However, the new algorithm is developed completely in spherical Earth-centered coordinates (longitude, latitude, altitude), rather than in the (x, y, z) cartesian coordinates employed in the 1996 study. Hence, no mathematical transformations from (x, y, z) into spherical coordinates are required (such transformations involve more numerical error propagation, more computer program coding, and slightly more CPU computing time). The new algorithm also has a more realistic definition of source altitude that accounts for Earth oblateness (this can become important for sources that are hundreds of kilometers away from the network). In addition, the new algorithm is being applied to analyze computer simulated LMA datasets in order to obtain detailed location/time retrieval error maps for sources in and around the LMA network. These maps will provide a more comprehensive analysis of retrieval errors for LMA than the 1996 study did of LDAR retrieval errors. Finally, we note that the new algorithm can be applied to LDAR, and essentially any other multi-station TWA network that depends on direct line-of-site antenna excitation.

Koshak, William↗

WAVELENGTH ACCURACY OF THE KECK HIRES SPECTROGRAPH AND MEASURING CHANGES IN THE FINE STRUCTURE CONSTANT

We report on an attempt to accurately wavelength calibrate four nights of data taken with the Keck HIRES spectrograph on QSO PHL957, for the purpose of determining whether the fine structure constant was different in the past. Using new software and techniques, we measured the redshifts of various Ni II, Fe II, Si II, etc. lines in a damped Lyalpha system at z = 2.309. Roughly half the data were taken through the Keck iodine cell which contains thousands of well calibrated iodine lines. Using these iodine exposures to calibrate the normal Th-Ar Keck data pipeline output, we found absolute wavelength offsets of 500 m s{sup -1} to 1000 m s{sup -1} with drifts of more than 500 m s{sup -1} over a single night, and drifts of nearly 2000 m s{sup -1} over several nights. These offsets correspond to an absolute redshift of uncertainty of about DELTAz approx 10{sup -5}(DELTAlambda approx 0.02 A), with daily drifts of around DELTAz approx 5 x 10{sup -6} (DELTAlambda approx 0.01 A), and multiday drifts of nearly DELTAz approx 2 x 10{sup -5}(approx0.04 A). The causes of the wavelength offsets are not known, but since claimed shifts in the fine structure constant would result in velocity shifts of less than 100 m s{sup -1}, this level of systematic uncertainty may make it difficult to use Keck HIRES data to constrain the change in the fine structure constant. Using our calibrated data, we applied both our own fitting software and standard fitting software to measure DELTAalpha/alpha, but discovered that we could obtain results ranging from significant detection of either sign, to strong null limits, depending upon which sets of lines and which fitting method were used. We thus speculate that the discrepant results on DELTAalpha/alpha reported in the literature may be due to random fluctuations coming from underestimated systematic errors in wavelength calibration and fitting procedure.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-G-JeP4-01: An Assessment of a Microsoft Kinect V2 Sensor for Voluntary Breath-Hold Monitoring in Radiotherapy

Purpose: To determine whether the Microsoft Kinect Version 2 (Kinect v2), a commercial off-the-shelf (COTS) depth sensors designed for entertainment purposes, were robust to the radiotherapy treatment environment and could be suitable for monitoring of voluntary breath-hold compliance. This could complement current visual monitoring techniques, and be useful for heart sparing left breast radiotherapy. Methods: In-house software to control Kinect v2 sensors, and capture output information, was developed using the free Microsoft software development kit, and the Cinder creative coding C++ library. Each sensor was used with a 12m USB 3.0 active cable. A solid water block was used as the object. The depth accuracy and precision of the sensors was evaluated by comparing Kinect reported distance to the object with a precision laser measurement across a distance range of 0.6m to 2.0 m. The object was positioned on a high-precision programmable motion platform and moved in two programmed motion patterns and Kinect reported distance logged. Robustness to the radiation environment was tested by repeating all measurements with a linear accelerator operating over a range of pulse repetition frequencies (6Hz to 400Hz) and dose rates 50 to 1500 monitor units (MU) per minute. Results: The complex, consistent relationship between true and measured distance was unaffected by the radiation environment, as was the ability to detect motion. Sensor precision was < 1 mm and the accuracy between 1.3 mm and 1.8 mm when a distance correction was applied. Both motion patterns were tracked successfully with a root mean squared error (RMSE) of 1.4 and 1.1 mm respectively. Conclusion: Kinect v2 sensors are capable of tracking pre-programmed motion patterns with an accuracy <2 mm and appear robust to the radiotherapy treatment environment. A clinical trial using Kinect v2 sensor for monitoring voluntary breath hold has ethical approval and is open to recruitment. The authors are supported by a National Institute of Health Research (NIHR) Career Development Fellowship (CDF-2013-06-005). Microsoft Corporation donated three sensors. The views expressed in this publication are those of the author(s) and not necessarily those of the NHS, the National Institute for Health Research or the Department of Health.

60 APPLIED LIFE SCIENCES↗

Small arms suppression project (LLNL final report)

US Special Operations Command (USSOCOM) was seeking a technological leap in small firearms weapon suppressor technology, because anticipated enemy capabilities are requiring the operators to have smaller detection cross sections to ensure the safe execution of missions. Suppressors have been developed almost exclusively through trial-and-error methods since the time of the original design by Hiram Maxim over one hundred years ago. Consequently USSOCOM deemed it prudent to perform a physicsbased study of weapon suppression to understand performance limits and possibly identify breakthrough technologies. Lawrence Livermore National Laboratory’s (LLNL’s) high performance production level computational tool called ALE3D (Arbitrary Lagrangian-Eulerian 3D and 2D) has unique physics models and numerical algorithms for modeling suppressor dynamics. The flexible and extendable code framework supports fully integrated hydrodynamics, heat transfer, solid and fluid dynamics, and chemistry that can be applied to simulating propellant-driven motion of a bullet down a gun barrel, the transfer of heat from the burning propellant to the barrel and suppressor, the chemistry of muzzle flash, and the shock/acoustic/optical signatures in the near-field. LLNL’s originally anticipated role was to augment ALE3D for this task, by developing the software and analysis methodologies specific to the simulation of blast and muzzle flash phenomena. It was believed that insights provided by our ALE3D simulations in tandem with a coordinated experimental component by our other team members from Oak Ridge National Laboratory (ORNL) and the U. S. Army Armament, Research, Development and Engineering Center (ARDEC), would have excellent prospects of yielding useful suppressor design improvements that could be transitioned to industry and utilized by US Special Operations Command. The three year effort has come to fruition with the development of revolutionary suppressor designs that far outperform any previous or current design by anyone outside this multi-lab team.

42 ENGINEERING↗

The AAMP5/AAMP-FV project

This presentation describes a project, formal verification of the microcode in the AAMP5 microprocessor, conducted to explore how formal techniques for specification and verification could be introduced into an industrial process. Sponsored by the Systems Validation Branch of NASA Langley and by Collins Commercial Avionics, a division of Rockwell International, it was conducted by Collins and the SRI International Computer Science Laboratory. The project consisted of specifying in the PVS language developed by SRI a portion of a Rockwell proprietary microprocessor, the AAMP5, at both the instruction set and register-transfer levels and using the PVS theorem prover to prove the microcode correct for a representative subset of instructions. While this presentation includes a brief technical overview, its emphasis is on the lessons learned in using PVS for an example of this size and the implications for using formal methods in an industrial setting. The central result of this project was to demonstrate the feasibility of formally specifying a commercial microprocessor and the use of mechanical proofs of correctness to verify microcode. This is particularly significant since the AAMP5 was not designed for formal verification, but to provide a more than three fold performance improvement, by pipelining instruction execution, while remaining object code compatible with the earlier AAMP2. As a consequence, the AAMP5 is one of the most complex microprocessors to which formal methods have been applied. Another key result was the discovery of both actual and seeded errors. Two actual microcode errors were discovered and corrected during development of the formal specification, illustrating the value of simply creating a precise specification. Two seeded errors were systematically uncovered while doing correctness proofs. One of these was an actual error that had been discovered after first fabrication but left in the microcode provided to SRI. The other error was designed to be unlikely to be detected by walkthroughs, testing, or simulation. Several other results emerged during the project, including the ease with which practicing engineers became comfortable with PVS, the need for libraries of general purpose theories, the usefulness of formal specification in revealing errors, the natural fit between formal specification and inspections, the difficulty of selecting the best style of specification for a new problem domain, the high level of assurance provided by proofs of correctness, and the need to engineer proof strategies for reuse.

Miller, Steven P.↗

The shape of the CMB lensing bispectrum

Lensing of the CMB generates a significant bispectrum, which should be detected by the Planck satellite at the 5-sigma level and is potentially a non-negligible source of bias for f{sub NL} estimators of local non-Gaussianity. We extend current understanding of the lensing bispectrum in several directions: (1) we perform a non-perturbative calculation of the lensing bispectrum which is ∼ 10% more accurate than previous, first-order calculations; (2) we demonstrate how to incorporate the signal variance of the lensing bispectrum into estimates of its amplitude, providing a good analytical explanation for previous Monte-Carlo results; and (3) we discover the existence of a significant lensing bispectrum in polarization, due to a previously-unnoticed correlation between the lensing potential and E-polarization as large as 30% at low multipoles. We use this improved understanding of the lensing bispectra to re-evaluate Fisher-matrix predictions, both for Planck and cosmic variance limited data. We confirm that the non-negligible lensing-induced bias for estimation of local non-Gaussianity should be robustly treatable, and will only inflate f{sub NL} error bars by a few percent over predictions where lensing effects are completely ignored (but note that lensing must still be accounted for to obtain unbiased constraints). We also show that the detection significance for the lensing bispectrum itself is ultimately limited to 9 sigma by cosmic variance. The tools that we develop for non-perturbative calculation of the lensing bispectrum are directly relevant to other calculations, and we give an explicit construction of a simple non-perturbative quadratic estimator for the lensing potential and relate its cross-correlation power spectrum to the bispectrum. Our numerical codes are publicly available as part of CAMB and LensPix.

79 ASTRONOMY AND ASTROPHYSICS↗

Influence of Coronal Abundance Variations

The PI of this project was Jeff Scargle of NASA/Ames. Co-I's were Alma Connors of Eureka Scientific/Wellesley, and myself. Part of the work was subcontracted to Eureka Scientific via SAO, with Vinay Kashyap as PI. This project was originally assigned grant number NCC2-1206, and was later changed to NCC2-1350 for administrative reasons. The goal of the project was to obtain, derive, and develop statistical and data analysis tools that would be of use in the analyses of high-resolution, high-sensitivity data that are becoming available with new instruments. This is envisioned as a cross-disciplinary effort with a number of "collaborators" including some at SA0 (Aneta Siemiginowska, Peter Freeman) and at the Harvard Statistics department (David van Dyk, Rostislav Protassov, Xiao-li Meng, Epaminondas Sourlas, et al). We have developed a new tool to reliably measure the metallicities of thermal plasma. It is unfeasible to obtain high-resolution grating spectra for most stars, and one must make the best possible determination based on lower-resolution, CCD-type spectra. It has been noticed that most analyses of such spectra have resulted in measured metallicities that were significantly lower than when compared with analyses of high- resolution grating data where available (see, e.g., Brickhouse et al., 2000, ApJ 530,387). Such results have led to the proposal of the existence of so-called Metal Abundance Deficient, or "MAD" stars (e.g., Drake, J.J., 1996, Cool Stars 9, ASP Conf.Ser. 109, 203). We however find that much of these analyses may be systematically underestimating the metallicities, and using a newly developed method to correctly treat the low-counts regime at the high-energy tail of the stellar spectra (van Dyk et al. 2001, ApJ 548,224), have found that the metallicities of these stars are generally comparable to their photospheric values. The results were reported at the AAS (Sourlas, Yu, van Dyk, Kashyap, and Drake, 2000, BAAS 196, v32, #54.02), and at the conference on Statistical Challenges in Modem Astronomy (Sourlas, van Dyk, Kashyap, Drake, and Pease, 2003, SCMA 111, Eds. E.D.Feigelson, G.J.Babu, New York:Springer, p489-490). We also described the limitations of one of the most egregiously misused and misapplied statistical tests in astrophysical literature, the F-test for verifying model components (Protassov, van Dyk, Connors, Kashyap, and Siemiginowska, 2002, ApJ, 571,545). Indeed, a search through the ApJ archives turned up 170 papers in the 5 previous years that used the F-test explicitly in some form or the other, and with the vast majority of them not using it correctly! Indeed, looking at just 4 issues of the ApJ in 2001, we found 13 instances of its use, of which nine were demonstrably incorrect. Clearly, it is difficult to understate the importance of this issue. We also worked on speeding up Bayes Blocks and Sparse Bayes Blocks algorithms to make them more tractable for large searches. We also supported staistics students and postdocs in both explicit physics- model-based (spectra with tens of thousands of atomic lines) and "model-free" -- i.e. non-parametric or semi-parametric -- algorithms. Work on using more of the latter is just beginning; while using multi-scale methods for Poisson imaging has come to hition. In fact, "An Image Restoration Technique with Error Estimates", by D. Esch, A. Connors, M. Karovska, and D. van Dyk, was published by ApJ (Esch et a1.2004, ApJ, 610, 1213). The code has been delivered to M. Karovska for CXC; and is available for beta-testing upon request. The other large project we worked on was on the self-consistent modeling of logN-logs curves in the Poisson limit. logN-logs curves are a fundamental tool in the study of source populations, luminosity functions, and cosmological parameters. However, their determination is hampered by statistical effects such as the Eddington bias, incompleteness due to detection efficiency, faint source flux fluctuations, etc. We have develed a new and powerful method using the full Poisson machinery that allows us to model the logN-logs distribution of X-ray sources in a self-consistent manner. Because we properly account for all the above statistical effects, our modeling is valid over the full range of the data, and not just for strong sources, as is normally done. Using a Bayesian approach and modeling the fluxes with known functional forms such as simple or broken power-laws, and conditioning the expected photon counts on the fluxes, the background contamination, effective area, detector vignetting, and detection probability, we can delve deeply into the low counts regime and extend the usefulness of medium sensitivity surveys such as ChAMP by orders of magnitude. The built-in flexibility of the algorithm also allows a simultaneous analysis of multiple datasets. We have applied this analysis to a set a Chandra observations (Sourlas, Kashyap, Zezas, van Dyk, 2004, HEAD #8, #16.32)

Scargle, Jeffrey D.↗

Coexistent quantum channel characterization using quantum process tomography with spectrally resolved detection

The coexistence of classical and quantum signals over the same optical fiber is critical for quantum networks operating within the existing communications infrastructure. Here, we characterize the quantum channel that results from distributing approximate single-photon polarization-encoded qubits simultaneously with classical light of varying intensities through a 25 km fiber-optic channel. We use spectrally resolved quantum process tomography with a newly developed Bayesian reconstruction method to estimate the quantum channel from experimental data, both with and without classical noise. Furthermore, we show that the coexistent fiber-based quantum channel has high process fidelity with an ideal depolarizing channel if the noise is dominated by Raman scattering. These results aid future development of quantum repeater designs and quantum error-correcting codes which benefit from realistic channel error models.

Chapman, Joseph↗

Quantum steganography with noisy quantum channels

Steganography is the technique of hiding secret information by embedding it in a seemingly ''innocent'' message. We present protocols for hiding quantum information by disguising it as noise in a codeword of a quantum error-correcting code. The sender (Alice) swaps quantum information into the codeword and applies a random choice of unitary operation, drawing on a secret random key she shares with the receiver (Bob). Using the key, Bob can retrieve the information, but an eavesdropper (Eve) with the power to monitor the channel, but without the secret key, cannot distinguish the message from channel noise. We consider two types of protocols: one in which the hidden quantum information is stored locally in the codeword, and another in which it is embedded in the space of error syndromes. We analyze how difficult it is for Eve to detect the presence of secret messages, and estimate rates of steganographic communication and secret key consumption for specific protocols and examples of error channels. We consider both the case where there is no actual noise in the channel (so that all errors in the codeword result from the deliberate actions of Alice), and the case where the channel is noisy and not controlled by Alice and Bob.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Flow Characteristics of Intermediate Heat Exchanger with CFD Methodology on Nuclear Safety Application

The intermediate heat exchanger (IHX) plays an important role in the field of nuclear power plant, and its safety margin could strongly affected by the flow distribution of secondary flow inlet. As a result, the size of secondary inlet is crucial in thermal design. However, the IHX contains thousands of heat exchanger tubes, and it takes larger time to simulate each tube accurately. Other than that, there are more delicate devices in a nuclear power plant, so it would take too much time to simulate actual model. Although system code could solve problems effectively, it could not detect local deformation. On nuclear safety application, how to save time and receive specific results in an efficient way is necessary. Therefore, the porous media model and the heat exchanger model from computational fluid dynamics (CFD) were adopted in this study. The methodology not only can save much time than actual model but also receive more specific results than system code. To ensure the accuracy, validation of the methodology is also presented in this study by modeling RHR heat exchanger of L nuclear power plant. The results of the simulation were compared to experimental values from L nuclear power plant and receive small errors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Implicit-explicit evolution of single black holes

Numerical simulations of binary black holes - an important predictive tool for the detection of gravitational waves - are computationally expensive, especially for binaries with high mass ratios or with rapidly spinning constituent holes. Existing codes for evolving binary black holes rely on explicit time-stepping methods, for which the time-step size is limited by the smallest spatial scale through the Courant-Friedrichs-Lewy condition. Binary inspiral typically involves spatial scales (the spatial resolution required by a small or rapidly spinning hole) which are orders of magnitude smaller than the relevant (orbital, precession, and radiation-reaction) time scales characterizing the inspiral. Therefore, in explicit evolutions of binary black holes, the time-step size is typically orders of magnitude smaller than the relevant physical time scales. Implicit time-stepping methods allow for larger time steps, and they often reduce the total computational cost (without significant loss of accuracy) for problems dominated by spatial rather than temporal error, such as for binary-black-hole inspiral in corotating coordinates. However, fully implicit methods can be difficult to implement for nonlinear evolution systems like the Einstein equations. Therefore, in this paper we explore implicit-explicit (IMEX) methods and use them for the first time to evolve black-hole spacetimes. Specifically, as a first step toward IMEX evolution of a full binary-black-hole spacetime, we develop an IMEX algorithm for the generalized harmonic formulation of the Einstein equations and use this algorithm to evolve stationary and perturbed single-black-hole spacetimes. Numerical experiments explore the stability and computational efficiency of our method.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-D-207-05: Real-Time Intrafractional Motion Tracking During VMAT Delivery Using a Conventional Elekta CBCT System

Purpose: Real-time kV projection streaming capability has become recently available for Elekta XVI version 5.0. This study aims to investigate the feasibility and accuracy of real-time fiducial marker tracking during CBCT acquisition with or without simultaneous VMAT delivery using a conventional Elekta linear accelerator. Methods: A client computer was connected to an on-board kV imaging system computer, and receives and processes projection images immediately after image acquisition. In-house marker tracking software based on FFT normalized cross-correlation was developed and installed in the client computer. Three gold fiducial markers with 3 mm length were implanted in a pelvis-shaped phantom with 36 cm width. The phantom was placed on a programmable motion platform oscillating in anterior-posterior and superior-inferior directions simultaneously. The marker motion was tracked in real-time for (1) a kV-only CBCT scan with treatment beam off and (2) a kV CBCT scan during a 6-MV VMAT delivery. The exposure parameters per projection were 120 kVp and 1.6 mAs. Tracking accuracy was assessed by comparing superior-inferior positions between the programmed and tracked trajectories. Results: The projection images were successfully transferred to the client computer at a frequency of about 5 Hz. In the kV-only scan, highly accurate marker tracking was achieved over the entire range of cone-beam projection angles (detection rate / tracking error were 100.0% / 0.6±0.5 mm). In the kV-VMAT scan, MV-scatter degraded image quality, particularly for lateral projections passing through the thickest part of the phantom (kV source angle ranging 70°-110° and 250°-290°), resulting in a reduced detection rate (90.5%). If the lateral projections are excluded, tracking performance was comparable to the kV-only case (detection rate / tracking error were 100.0% / 0.8±0.5 mm). Conclusion: Our phantom study demonstrated a promising Result for real-time motion tracking using a conventional Elekta linear accelerator. MV-scatter suppression is needed to improve tracking accuracy during MV delivery. This research is funded by Motion Management Research Grant from Elekta.

60 APPLIED LIFE SCIENCES↗

The picasso map-making code: application to a simulation of the QUIJOTE northern sky survey

ABSTRACT Map-making is an important step for the data analysis of cosmic microwave background (CMB) experiments. It consists of converting the data, which are typically a long, complex, and noisy collection of measurements, into a map, which is an image of the observed sky. We present in this paper a new map-making code named picasso (Polarization and Intensity CArtographer for Scanned Sky Observations), which was implemented to construct intensity and polarization maps from the Multi Frequency Instrument (MFI) of the QUIJOTE (Q-U-I Joint TEnerife) CMB polarization experiment. picasso is based on the destriping algorithm, and is suited to address specific issues of ground-based microwave observations, with a technique that allows the fit of a template function in the time domain, during the map-making step. This paper describes the picasso code, validating it with simulations and assessing its performance. For this purpose, we produced realistic simulations of the QUIJOTE-MFI survey of the northern sky (approximately ∼20 000 deg2), and analysed the reconstructed maps with picasso, using real and harmonic space statistics. We show that, for this sky area, picasso is able to reconstruct, with high fidelity, the injected signal, recovering all the scales with ℓ > 10 in TT, EE, and BB. The signal error is better than 0.001 per cent at 20 < ℓ < 200. Finally, we validated some of the methods that will be applied to the real wide-survey data, like the detection of the CMB anisotropies via cross-correlation analyses. Despite that the implementation of picasso is specific for QUIJOTE-MFI data, it could be adapted to other experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

NASA Tech Briefs, August 2005

Topics include: Hidden Identification on Parts: Magnetic Machine-Readable Matrix Symbols; System for Processing Coded OFDM Under Doppler and Fading; Multipurpose Hyperspectral Imaging System; Magnetic-Flux-Compensated Voltage Divider; High-Performance Satellite/Terrestrial-Network Gateway; Internet-Based System for Voice Communication With the ISS; Stripline/Microstrip Transition in Multilayer Circuit Board; Dual-Band Feed for a Microwave Reflector Antenna; Quadratic Programming for Allocating Control Effort; Range Process Simulation Tool; Simulator of Space Communication Networks; Computing Q-D Relationships for Storage of Rocket Fuels; Contour Error Map Algorithm; Portfolio Analysis Tool; Glass Frit Filters for Collecting Metal Oxide Nanoparticles; Anhydrous Proton-Conducting Membranes for Fuel Cells; Portable Electron-Beam Free-Form Fabrication System; Miniature Laboratory for Detecting Sparse Biomolecules; Multicompartment Liquid-Cooling/Warming Protective Garments; Laser Metrology for an Optical-Path-Length Modulator; PCM Passive Cooling System Containing Active Subsystems; Automated Electrostatics Environmental Chamber; Estimating Aeroheating of a 3D Body Using a 2D Flow Solver; Artificial Immune System for Recognizing Patterns; Computing the Thermodynamic State of a Cryogenic Fluid; Safety and Mission Assurance Performance Metric; Magnetic Control of Concentration Gradient in Microgravity; Avionics for a Small Robotic Inspection Spacecraft; and Simulation of Dynamics of a Flexible Miniature Airplane.

Source record↗