Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Dynamical mean field theory”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

933 records · Page 20

Thermally induced mimicry of quantum cluster excitations and implications for the magnetic transition in FePSe 3

In two dimensional magnets, the interplay of thermal fluctuations and spin anisotropy control the existence of long-range magnetic order. In the van der Waals antiferromagnets FePX 3 , orbital degeneracy in the 𝑡 2⁢𝑔 levels of the Fe 2+ ions in octahedral coordination yields strong uniaxial anisotropy, which stabilizes magnetic order up to 𝑇 ≈ 100 K. Recent inelastic neutron scattering measurements around the magnetic ordering transition have shown the existence of a broad spectrum of magnetic fluctuations with nontrivial momentum dependence, which has been interpreted as evidence for localized entangled cluster excitations. In this paper, we offer an alternative interpretation using classical nonlinear spin dynamics simulations. We present stochastic Landau Lifshitz dynamics simulations that reproduce the neutron scattering measurements of Chen et al. [npj Quantum Mater. 9, 40 (2024)] on FePSe 3 . These calculations faithfully explain the dynamical structure factor's momentum and energy dependence and point to a classical origin for the excitations observed in neutron spectroscopy and that the order-disorder transition can be understood in terms of thermal fluctuations overcoming the anisotropy energy.

Landau-Lifschitz-Gilbert equation

Dynamics and Structure of Weakly-Strained Flames In Normal- and Micro-Gravity

Strained laminar flames have been systematically studied, as the understanding of their structure and dynamic behavior is of relevance to turbulent combustion. Most of these studies have been conducted in opposed-jet, stagnation-type flow configurations. Flame studies in stagnation flows also allow for the determination of fundamental flame properties such as laminar flame speeds and extinction states that can be also conveniently modeled in detail. Studies at high strain rates are important in quantifying and understanding the response of vigorously-burning flames under conditions in which the transport time scales become comparable to the chemical time scales. Studies of weakly-strained flames can be of particular interest for all stoichiometries. For example, the laminar flame speeds for any equivalence ratio, phi, can be accurately determined by using the counterflow technique only if measurements are obtained at very low strain rates. Furthermore, near-limit flames can be only stabilized by weak strain rates. Previous studies have shown that weakly-burning flames are particularly sensitive to chain mechanisms, thermal radiation, and unsteadiness. The stabilization and study of weakly-strained flames is complicated by the presence of buoyancy that can render the flames unstable to the point of extinction. Such instabilities are caused either by the induced natural convection or the fact that higher density fluid can find itself on top of a lower density fluid. Thus, the use of microgravity (mu-g) becomes essential in order to provide meaningful insight into this important combustion regime. In view of the foregoing considerations, the main objectives of the program are to: (1) Experimentally determine the laminar flame speed at near-zero strain rates; (2) Experimentally determine the extinction limits of near-limit flames; (3) Experimentally determine the response of near-limit flames to unsteadiness and heat loss; (4) Introduce Digital Particle Image Velocimetry (DPIV) in microgravity; (5) Conduct detailed numerical simulations of the experiments; and (6) Provide physical insight into the underlying physico-chemical mechanisms.

Hai Zhang

Empirical Model Development for Predicting Shock Response on Composite Materials Subjected to Pyroshock Loading: Appendices - Volume 2, Part 1

The NASA Engineering and Safety Center (NESC) received a request to develop an analysis model based on both frequency response and wave propagation analyses for predicting shock response spectrum (SRS) on composite materials subjected to pyroshock loading. The model would account for near-field environment (approximately 9 inches from the source) dominated by direct wave propagation, mid-field environment (approximately 2 feet from the source) characterized by wave propagation and structural resonances, and far-field environment dominated by lower frequency bending waves in the structure. This document contains appendices to the Volume I report.

Steven J Gentz

Dynamic Interfacial Design in Adaptive Hybrid Materials Enables Reversible and Tunable Mechano-Optic Smart Responses

Next-generation polymeric materials are shifting toward adaptive and interactive behaviors of living systems; however, designing materials that can reversibly modulate optical properties under mechanical deformation while maintaining mechanical robustness remains a key challenge. Here, we report a mechanically robust vitrimer-based adaptive hybrid material (AHM) that exhibits a stretch-induced reversible transparency-to-opacity transition, enabled by the integration of dynamic interactions at the polymer–silica nanoparticle interface and controlled nanoparticle self-assembly. The AHM combines boronic ester–functionalized polystyrene-b-poly(ethylene-co-butylene)-b-polystyrene (S-Bpin) with diol-functionalized silica nanoparticles (diol-SiNPs) to form a hybrid network hosting both dynamic boronic ester and hydrogen-bonding interactions. These reversible linkages facilitate controlled nanoparticle self-assembly and enable strain-induced nanoparticle alignment/aggregation. Upon stretching, SiNP-rich domains align and aggregate within the polymer matrix, while local modulus mismatch between stiff aggregated SiNP/borylated-styrene-rich regions and the softer elastomeric midblock induces surface microwrinkle formation. These internal aggregates and surface wrinkles cooperatively enhance light scattering, producing the opaque state under strain. Furthermore, the tailored AHM exhibits high toughness, thermomechanical stability, reprocessability, and programmable shape-memory behavior. This work presents a dynamic interfacial design strategy for mechanically robust, optically reconfigurable, and reusable soft materials for adaptive optics, smart windows, sensing, soft robotics, and circular smart-material platforms.

adaptive hybrid materials

Vesicular Stomatitis Virus Transmission Dynamics Within Its Endemic Range in Chiapas, Mexico

Vesicular stomatitis virus (VSV), comprising vesicular stomatitis New Jersey virus (VSNJV) and vesicular stomatitis Indiana virus (VSIV), emerges from its focus of endemic transmission in Southern Mexico to cause sporadic livestock epizootics in the Western United States. A dearth of information on the role of potential arthropod vectors in the endemic region hampers efforts to identify factors that enable endemicity and predict outbreaks. In a two-year, longitudinal study at five cattle ranches in Chiapas, Mexico, insect taxa implicated as VSV vectors (blackflies, sandflies, biting midges, and mosquitoes) were collected and screened for VSV RNA, livestock vesicular stomatitis (VS) cases were monitored, and serum samples were screened for neutralizing antibodies. VS cases were reported during the rainy (n = 20) and post-rainy (n = 2) seasons. Seroprevalence against VSNJV in adult cattle was very high (75–100% per ranch) compared with VSIV (0.6%, all ranches). All four potential vector taxa were sampled, and VSNJV RNA was detected in each of them (11% VSNJV-positive of 874 total pools), while VSIV RNA was only detected in four pools of mosquitoes. Our findings indicate that VSNJV is the dominant serotype across our sampling sites with a variety of potential insect vectors involved in its transmission throughout the year. Although no livestock cases were reported in Chiapas during the dry season, VSNJV was detected in insects during this period, suggesting that mechanisms other than transmission from livestock support VSV endemicity.

Virology

Single-Drop Reactive Extraction/Extractive Reaction With Forced Convective Diffusion and Interphase Mass Transfer

An algorithm has been developed for time-dependent forced convective diffusion-reaction having convection by a recirculating flow field within the drop that is hydrodynamically coupled at the interface with a convective external flow field that at infinity becomes a uniform free-streaming flow. The concentration field inside the droplet is likewise coupled with that outside by boundary conditions at the interface. A chemical reaction can take place either inside or outside the droplet, or reactions can take place in both phases. The algorithm has been implemented, and for comparison results are shown here for the case of no reaction in either phase and for the case of an external first order reaction, both for unsteady behavior. For pure interphase mass transfer, concentration isocontours, local and average Sherwood numbers, and average droplet concentrations have been obtained as a function of the physical properties and external flow field. For mass transfer enhanced by an external reaction, in addition to the above forms of results, we present the enhancement factor, with the results now also depending upon the (dimensionless) rate of reaction.

Leonid S Kleinman

Identifying Strain Stacking Boundaries between Multiphase Domains in Atomically Thin Two-Dimensional Magnets

Stacking engineering of van der Waals materials is an important strategy to control the materials’ properties, such as electronic correlations, ferroelectricity, and layer-dependent two-dimensional magnetism. A timely testbed for the study of the latter is atomically thin chromium trihalides (CrX 3 , X = Cl, Br, I). Notably, by understanding the sliding mechanism between different stacking sequences, control of the stacking arrangement, and thus magnetic properties in CrX 3 , can be achieved. Such insight, however, is currently lacking. Here, in this study, advanced electron microscopy methods are used to identify multiple stacking sequences corresponding to different bulk phases in atomically thin CrX 3 (X = Cl and Br) down to bilayer thickness and with lateral domain sizes as small as tens of nanometers. Indications of nanometer scale transitions and interactions at the stacking boundaries are found, including a universally preferred sliding direction that is consistent with density functional theory calculations and the strain fields at lateral heterostructure boundaries. This study demonstrates the necessity to consider local stacking structures when interpreting averaged magnetic properties measured with macroscale probes. Additionally, the preferred sliding direction insight from this study provides a strategy to control stacking sequence in atomically thin CrX 3 samples during the exfoliation and sample fabrication process.

DFT calculations

Theoretical perspective on phase stability and polarization switching in ferroelectric hafnia

Fluorite-based ferroelectric materials are revolutionizing the application space of polar semiconductors. These materials leverage robust polarization of extremely thin films, compatibility with the silicon chip processing, and decades of manufacturing experience to enable a new generation of ferroelectric memory devices. As a new paradigm for ferroelectrics, understanding of phase transitions and the switching mechanism in fluorites is essential both for advancing applications and for fundamental science. In this article, we outline the recent progress that has been made to understand the relative phase stability, phase transition and order parameter coupling, ferroelectric switching through unique nucleation and growth processes, and how defects affect these phases and processes. The main challenges, opportunities, and next steps for leveraging these materials for next-generation devices are reviewed.

Condensed Matter Physics

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Organic Inventory - Planetary Protection on the Moon

All spacecraft generate and carry contaminants, i.e., unwanted and potentially harmful material. When a spacecraft lands and operates in vacuum, as onto Earth’s Moon, it introduces contaminants into its environment that may compromise mission science objectives and engineering performance. Contamination may degrade sites of unique value to planetary science or in situ resource utilization. This presentation will identify and compare source terms and transport vectors for contaminants – in particular, organic material – generated by landed spacecraft. An integrated modeling framework for the organic contamination footprint of spacecraft missions will be described and presented.

Planetary Protection

WRF-Comfort: simulating microscale variability in outdoor heat stress at the city scale with a mesoscale model

Abstract. Urban overheating and its ongoing exacerbation due to global warming and urban development lead to increased exposure to urban heat and increased thermal discomfort and heat stress. To quantify thermal stress, specific indices have been proposed that depend on air temperature, mean radiant temperature (MRT), wind speed, and relative humidity. While temperature and humidity vary on scales of hundreds of meters, MRT and wind speed are strongly affected by individual buildings and trees and vary on the meter scale. Therefore, most numerical thermal comfort studies apply microscale models to limited spatial domains (commonly representing urban neighborhoods with building blocks) with resolutions on the order of 1 m and a few hours of simulation. This prevents the analysis of the impact of city-scale adaptation and/or mitigation strategies on thermal stress and comfort. To solve this problem, we develop a methodology to estimate thermal stress indicators and their subgrid variability in mesoscale models – here applied to the multilayer urban canopy parameterization BEP-BEM within the Weather Research and Forecasting (WRF) model. The new scheme (consisting of three main steps) can readily assess intra-neighborhood-scale heat stress distributions across whole cities and for timescales of minutes to years. The first key component of the approach is the estimation of MRT in several locations within streets for different street orientations. Second, mean wind speed and its subgrid variability are downscaled as a function of the local urban morphology based on relations derived from a set of microscale LES and RANS simulations across a wide range of realistic and idealized urban morphologies. Lastly, we compute the distributions of two thermal stress indices for each grid square, combining all the subgrid values of MRT, wind speed, air temperature, and absolute humidity. From these distributions, we quantify the high and low tails of the heat stress distribution in each grid square across the city, representing the thermal diversity experienced in street canyons. In this contribution, we present the core methodology as well as simulation results for Madrid (Spain), which illustrate strong differences between heat stress indices and common heat metrics like air or surface temperature both across the city and over the diurnal cycle.

Geology

Adaptation and Response in Drylands (ARID): A Dryland Research Agenda and Campaign Strategy

Dryland ecosystems cover 41% of Earth’s land surfaces, account for 44% of cultivated lands and 60% of food sources, and make large contributions to the global water and carbon cycles. However, these ecosystems are experiencing unprecedented extremes including heatwaves, floods, and droughts as well as hotter temperatures and often declining water resource availability. These ecosystems are some of the most challenging to monitor given their high temporal variability with rapid response to their environment as well as vast spatial variability with intermixing of different plant species and life forms amongst bare soil coverage. The Adaptation and Response in Drylands (ARID) campaign was selected by National Aeronautics and Space Administration (NASA) as a scoping study to develop a research agenda for a dryland field campaign. Here, we detail our ARID science research agenda and implementation plan that were developed based on an extensive community engagement effort in over 160 events with over a thousand scientists, land managers, and Tribal communities between 2023 and 2024. The selected science themes cover drought and climate variability, ecosystem structure, function, and biodiversity, carbon cycle interannual variability and trends, and social ecological systems (land management and adaptation). We then detail our remote sensing, modeling, and field-based strategies to capture high temporal and high spatial resolution processes. Finally, our implementation strategy is presented which includes focus area selections in a core intensive western U.S. domain and distributed international domains. This strategy includes our overarching guiding principles of using multi-temporal airborne acquisitions and super sites as well as enhancing land management in co-development with end-user partners. While originally developed for NASA, our ARID report creates a blueprint for any future dryland field campaign, at any scale, that can be implemented widely for foundational and applied science objectives.

drylands

Dynamic asymmetric strain imprinted into substrates by an oxide thin film

In film-substrate systems, the substrate role is often considered to be limited to providing static mechanical constraints. Dynamic film-substrate interactions when a structural change in the film modifies the substrate are generally disregarded. Here, using combined x-ray and electron microscopies, we observed that an electrically induced filament in a vanadium dioxide film created strong asymmetric strain in an underlying sapphire substrate. This asymmetric substrate strain fed back into the film and defined the filament expansion direction, revealing the importance of film-substrate dynamic interactions in determining film functionality. Furthermore, the strain imprint propagated at least tens of micrometers deep into the substrate, exceeding the film thickness by more than 200-fold, potentially enabling substrate functionalization as an active mechanical coupling media in three-dimensional integrated microelectronic architectures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND

The Contaminant Footprint of Landed Spacecraft: Toward an Inventory and Modelling Framework

All spacecraft generate and carry contaminants, i.e., unwanted and potentially harmful material. When a spacecraft lands and operates in vacuum, as onto Earth’s Moon, it introduces contaminants into its environment that may compromise mission science objectives and engineering performance. Contamination may degrade sites of unique value to planetary science or in situ resource utilization. This presentation will identify and compare source terms and transport vectors for contaminants – in particular, organic material – generated by landed spacecraft. An integrated modeling framework for the organic contamination footprint of spacecraft missions will be described and presented.

Gas Dynamics

Dynamic nanodomains dictate macroscopic properties in lead halide perovskites

Lead halide perovskites have emerged as promising materials for solar energy conversion and X-ray detection owing to their remarkable optoelectronic properties. However, the microscopic origins of their superior performance remain unclear. Here we show that low-symmetry dynamic nanodomains present in the high-symmetry average cubic phases, whose characteristics are dictated by the A-site cation, govern the macroscopic behaviour. We combine X-ray diffuse scattering, inelastic neutron spectroscopy, hyperspectral photoluminescence microscopy and machine-learning-assisted molecular dynamics simulations to directly correlate local nanoscale dynamics with macroscopic optoelectronic response. Our approach reveals that methylammonium-based perovskites form densely packed, anisotropic dynamic nanodomains with out-of-phase octahedral tilting, whereas formamidinium-based systems develop sparse, isotropic, spherical nanodomains with in-phase tilting, even when crystallography reveals cubic symmetry on average. We demonstrate that these sparsely distributed isotropic nanodomains present in formamidinium-based systems reduce electronic dynamic disorder, resulting in a beneficial optoelectronic response, thereby enhancing the performance of formamidinium-based lead halide perovskite devices. By elucidating the influence of the A-site cation on local dynamic nanodomains, and consequently, on the macroscopic properties, we propose leveraging this relationship to engineer the optoelectronic response of these materials, propelling further advancements in perovskite-based photovoltaics, optoelectronics and X-ray imaging.

Materials Science

Geometric Delocalization in Two Dimensions

We demonstrate the existence of transient two-dimensional surfaces where a random-walking particle escapes to infinity in contrast to localization in standard flat two-dimensional space. We first prove that any rotationally symmetric two-dimensional membrane embedded in flat three-dimensional space cannot be transient. Then we formulate a criterion for the transience of a general asymmetric two-dimensional membrane. We use it to explicitly construct a class of transient two-dimensional manifolds with a nontrivial metric and height function but “zero average curvature,” which we dub “tablecloth manifolds.” The absence of the logarithmic infrared divergence of the Laplace-Beltrami operator in turn implies the absence of weak localization, nonexistence of bound states in shallow potentials, and breakdown of the Mermin-Wagner theorem and Kosterlitz-Thouless transition on the tablecloth manifolds, which may be realizable in both quantum simulators and corrugated two-dimensional materials.

Anderson localization

Chapter 24 - Propulsion

This chapter provides a basic guide to the flight testing of propulsion system operability and compatibility (O&C). For the purposes of establishing a frame of reference, O&C refers to the ability of the aircrew to establish and maintain the desired level of propulsion system net propulsive force throughout the operating envelope of the aircraft. For the purposes of definition, net propulsive force is used to refer to the vector resultant of all throttle dependant forces acting upon the aircraft. By limiting the discussion in this Section to flight testing of the O&C of the propulsion system, it should not be interpreted to mean that these are the only factors that need to be considered when conducting flight test to evaluate an aircraft propulsion system. Propulsion system structural interfaces, pneumatic interfaces, mechanical interfaces, hydraulic interfaces, thermodynamic interfaces and electrical interfaces must all be evaluated prior to or concurrently with the O&C test program in order to ensure a safe and effective flight test program of the aircraft and propulsion system.

Lawrence A Thomas

Geospatial modeling of near subsurface temperatures of the contiguous United States for assessment of materials degradation

Abstract Understanding subsurface temperature variations is crucial for assessing material degradation in underground structures. This study maps subsurface temperatures across the contiguous United States for depths from 50 to 3500 m, comparing linear interpolation, gradient boosting (LightGBM), neural networks, and a novel hybrid approach combining linear interpolation with LightGBM. Results reveal heterogeneous temperature patterns both horizontally and vertically. The hybrid model performed best achieving a root mean square error of 2.61 °C at shallow depths (50–350 m). Model performance generally decreased with depth, highlighting challenges in deep temperature prediction. State-level analyses emphasized the importance of considering local geological factors. This study provides valuable insights for designing efficient underground facilities and infrastructure, underscoring the need for depth-specific and region-specific modeling approaches in subsurface temperature assessment.

Science & Technology - Other Topics