Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Doppler effect”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Detection of zonal flow spectra in DIII-D by a dual-channel Doppler backscattering system

Doppler backscattering (DBS) has been successfully used to measure the ExB flow velocity and local intermediate wavenumber density fluctuation levels in the DIII-D tokamak. Depending on the launch angle and the frequency of the probing beam, the signal backscattered from the plasma cut-off layer is sensitive to density fluctuations at a specific perpendicular wavenumber (1{<=}k{sub perpendicular}{rho}{sub s}{<=}4). Due to the localization and high time resolution for poloidal flow measurements, DBS is well suited to detect stationary and time-dependent shear flows [zonal flows (ZFs)]. We present a novel scheme to measure ZF spectra using a dual-channel DBS system capable of simultaneously probing two minor radii separated by a distance of 0.2 cm<{delta}r<3 cm. Frequency spectra of geodesic acoustic modes and low frequency ZFs (f{<=}10 kHz) have been obtained for 0.6<r/a<0.95.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Charge exchange spectroscopy as a fast ion diagnostic on TEXTOR

An upgraded charge exchange spectroscopy diagnostic has been taken into operation at the TEXTOR tokamak. The angles of the viewing lines with the toroidal magnetic field are close to the pitch angles at birth of fast ions injected by one of the neutral beam injectors. Using another neutral beam for active spectroscopy, injected counter the direction in which fast ions injected by the first beam are circulating, we can simultaneously measure a fast ion tail on the blue wing of the D{sub {alpha}} spectrum while the beam emission spectrum is Doppler shifted to the red wing. An analysis combining the two parts of the spectrum offers possibilities to improve the accuracy of the absolute (fast) ion density profiles. Fast beam modulation or passive viewing lines cannot be used for background subtraction on this diagnostic setup and therefore the background has to be modeled and fitted to the data together with a spectral model for the slowing down feature. The analysis of the fast ion D{sub {alpha}} spectrum obtained with the new diagnostic is discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A new fast-ion D{sub {alpha}} diagnostic for DIII-D

The fast-ion D{sub {alpha}} (FIDA) technique is a charge-exchange recombination spectroscopy measurement that exploits the large Doppler shift of Balmer-alpha light from energetic hydrogenic atoms to infer the fast-ion density. Operational experience with the first dedicated FIDA diagnostic on DIII-D is guiding the design of the second-generation instrument. In the first instrument, dynamic changes in background light associated with plasma instabilities usually dominate measurement uncertainties. Accordingly, the design of the new instrument minimizes scattering of cold D{sub {alpha}} light while monitoring its level. The first instrument uses a vertical view to avoid bright interference from the injected-neutral beams. The sightline of the new instrument includes a toroidal component but only measures blueshifted fast-ion light that is Doppler shifted away from the redshifted light of the injected neutrals. The new views are more sensitive to fast ions that circulate in the direction of the plasma current and less sensitive to the trapped-ion and countercirculating populations. Details of the design criteria and solutions are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Observation of fast-ion Doppler-shifted cyclotron resonance with shear Alfven waves

The Doppler-shifted cyclotron resonance ({omega}-k{sub z}v{sub z}={omega}{sub f}) between fast ions and shear Alfven waves is experimentally investigated ({omega}, wave frequency; k{sub z}, axial wavenumber; v{sub z}, fast-ion axial speed; {omega}{sub f}, fast-ion cyclotron frequency). A test particle beam of fast ions is launched by a Li{sup +} source in the helium plasma of the LArge Plasma Device (LAPD) [W. Gekelman, H. Pfister, Z. Lucky, J. Bamber, D. Leneman, and J. Maggs, Rev. Sci. Instrum. 62, 2875 (1991)], with shear Alfven waves (SAW) (amplitude {delta} B/B up to 1%) launched by a loop antenna. A collimated fast-ion energy analyzer measures the nonclassical spreading of the beam, which is proportional to the resonance with the wave. A resonance spectrum is observed by launching SAWs at 0.3-0.8{omega}{sub ci}. Both the magnitude and frequency dependence of the beam-spreading are in agreement with the theoretical prediction using a Monte Carlo Lorentz code that launches fast ions with an initial spread in real/velocity space and random phases relative to the wave. Measured wave magnetic field data are used in the simulation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gamma ray sources using imperfect relativistic mirrors

The collective backscattering of intense laser radiation by energetic electron beams is considered. Exact solutions for the radiation field are obtained, for arbitrary electron pulse shapes and laser intensities. The electron beams act as imperfect nonlinear mirrors on the incident laser radiation. This collective backscattering process can lead to the development of new sources of ultrashort pulse radiation in the gamma-ray domain. Numerical examples show that, for plausible experimental conditions, intense pulses of gamma rays, due to the double Doppler shift of the harmonics of the incident laser radiation, can be produced using the available technology, with durations less than one attosecond.

74 ATOMIC AND MOLECULAR PHYSICS↗

On the Use of Spectral Lines Emitted by Carbon Ions for Plasma Diagnostics in Magnetic Fusion Devices

Profiles of the n = 5-6 ({lambda} = 4658 A) and n = 6-7(7726 A) lines emitted by Li-like carbon C{sup +3} ions have been computed for plasma conditions of tokamak and stellarator divertors (N{sub e} = 10{sup 19}-10{sup 21} m{sup -3}, Te = 1-10 eV). The broadening and profiles of these lines are proposed to be used for plasma diagnostic purposes in particular to crosscheck the validity of the plasma parameters determined from the CIV line intensities measured in JT-60U tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Lifetime measurements using the CLARA-PRISMA setup around the {sup 48}Ca doubly-magic nucleus

The lifetimes of the first excited states of nuclei around the doubly-magic nucleus {sup 48}Ca have been determined using a novel method that combines the Recoil Distance Doppler Shift (RDDS) method with the CLARA-PRISMA spectrometers. This is the first time such a method is applied to measure lifetimes of neutron-rich nuclei populated via a multinucleon transfer reaction. This novel method and some preliminary results on lifetimes are presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Plunger lifetime measurements after Coulomb excitation at intermediate beam energies

Absolute transition probabilities of the first 2{sup +} state in {sup 110,114}Pd were remeasured using the recoil distance Doppler shift technique following projectile Coulomb excitation at intermediate beam energies for the first time. The {sup 110}Pd experiment served to check the novel technique as well as the method used for the data analysis which is based on the examination of {gamma}-ray lineshapes. Whereas the measured B(E2) value for {sup 110}Pd agrees very well with the literature, the value obtained for {sup 114}Pd differs considerably. The data is also used to test a novel concept, called the valence proton symmetry, which allows one to extrapolate nuclear properties to very neutron rich nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Low-lying Collective States in {sup 136}Ba

Low-lying collective states in {sup 136}Ba were investigated with (n,n'{gamma}) techniques, including Doppler-shift attenuation lifetime measurements. The level spins, lifetimes, branching ratios, multipole-mixing ratios and transition strengths reveal candidates for symmetric-phonon states up to third order. The 2{sub ms}{sup +} mixed-symmetry state was confirmed as unfragmented and a candidate for a [2{sub 1}{sup +} x 2{sub ms}{sup +}]{sub 3}{sup +} two-phonon mixed-symmetry state is proposed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Transition probabilities in the X(5) candidate {sup 122}Ba

The lifetimes of excited states of the {sup 122}Ba ground--state band, populated via the {sup 108}Cd({sup 16}O,2n){sup 122}Ba and the {sup 112}Sn({sup 13}C,2n){sup 122}Ba reactions, have been measured using the Recoil Distance Doppler--Shift method. The level scheme of {sup 122}Ba has also been revised.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Study of the Pygmy Dipole Resonance in {sup 124}Sn by means of the ({alpha},{alpha}'{gamma}) reaction

In recent years {alpha}-{gamma} coincidence experiments at 136 MeV incident energy on {sup 48}Ca, {sup 140}Ce, {sup 138}Ba and {sup 124}Sn were performed at the KVI in Groningen to study the isospin character of electric dipole excitations below the particle threshold, frequently called Pygmy Dipole Resonance (PDR). An array of HPGe {gamma}-detectors has been used in coincidence with the Big-Bite Spectrometer (BBS) and a resolution of about 10 keV in the {gamma}-ray energy has been achieved. The results show that the excitation patterns of the PDR in the ({alpha},{alpha}') reaction seem to differ significantly from results obtained in Nuclear Resonance Fluorescence (NRF)({gamma},{gamma}') measurements. The PDR, which until now has been assigned to one excitation mode, splits up into two parts: One that is excited in ({alpha},{alpha}'{gamma}) and ({gamma},{gamma}') reactions (denoting a dominant isoscalar character), and one that is only excited in ({gamma},{gamma}')(denoting a dominant isovector character). This indicates that two different excitation mechanisms produce these low-lying E1 excitations [1], The preliminary results of the latest measurements on the N = 82 nucleus {sup 138}Ba and the Z = 50 nucleus {sup 124}Sn show that this break up into two parts is a common feature of the PDR in semi-magic nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Lifetime Measurements and Coulomb Excitation of Light Hg Nuclei

Two complementary experimental programs have taken place to investigate the origin and evolution of shape coexistence in the light mercury region. Recoil Distance Doppler-shift measurements were performed at the University of Jyvaeskylae utilizing the Koeln plunger device in conjunction with the JUROGAM+RITU+GREAT setup. In addition, Coulomb excitation measurements of {sup 184,186,188}Hg were performed at REX-ISOLDE using the MINIBALL Ge-detector array. The results of the lifetime measurements of the yrast states up to I{sup {pi}} = 10{sup +} in {sup 182}Hg are reported. Preliminary analysis of the Coulomb excitation data is also discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evidence for the Importance of Soft Deformation Potentials in Strongly Deformed Nuclei

Excited states of {sup 168}Hf were populated using the {sup 124}Sn({sup 48}Ti,4n) fusion evaporation reaction at the WNSL of Yale University. The lifetimes of the J{sup {pi}} = 4{sup +},6{sup +},8{sup +}, and 10{sup +} levels along the ground state band of {sup 168}Hf were measured by means of the recoil distance Doppler shift (RDDS) method using the New Yale Plunger Device (NYPD) and the SPEEDY Ge detector array. The new lifetime values are sufficiently precise to clearly prove the increase of quadrupole collectivity as a function of angular momentum in the deformed nucleus {sup 168}Hf. The data agree with the predictions from the geometrical Confined {beta}-Soft (CBS) rotor model that involves centrifugal stretching in a soft potential. Relative and absolute E0 transition strengths [{rho}{sup 2}(E0)] on the transitional path between X(5) and the Rigid Rotor Limit have been evaluated within the framework of the CBS rotor model, too. Relative inter-band E0 transition strengths decrease with increasing angular momentum for a given potential stiffness, while for increasing potential stiffness, the absolute E0 transition strengths decrease with increasing angular momentum and increasing potential stiff0010ne.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Collectivity of {sup 98}Pd

The N = 52 nucleus {sup 98}Pd was investigated at the Cologne TANDEM accelerator both with the Cologne plunger using the recoil distance Doppler-shift method (RDDS) and with the Cologne HORUS spectrometer for a {gamma}{gamma} angular correlation experiment. For the first time lifetimes of yrast states and highly excited low-spin states were measured in {sup 98}Pd and the low-spin level scheme was extended. From our data we were able to interpret {sup 98}Pd as a nucleus that exhibits some collective features, but is obviously much less collective than the neighboring N = 52 isotones {sup 94}Mo and {sup 96}Ru due to its closeness to doubly-magic {sup 100}Sn.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comment on ''Generation of cold low divergent atomic beam of indium by laser ablation'' [Rev. Sci. Instrum. 76, 113302 (2005)]

We present measurements of the velocity distribution of calcium atoms in an atomic beam generated using a dual-stage laser back-ablation apparatus. Distributions are measured using a velocity selective Doppler time-of-flight technique. They are Boltzmann-like with rms velocities corresponding to temperatures above the melting point for calcium. Contrary to a recent report in the literature, this method does not generate a subthermal atomic beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Doppler-shifted cyclotron resonance of fast ions with circularly polarized shear Alfven waves

The Doppler-shifted cyclotron resonance between fast ions and shear Alfven waves (SAWs) has been experimentally investigated with a test-particle fast-ion (Li{sup +}) beam launched in the helium plasma of the Large Plasma Device [Gekelman et al., Rev. Sci. Instrum. 62, 2875 (1991)]. Left- or right-hand circularly polarized SAWs are launched by an antenna with four current channels. A collimated fast-ion energy analyzer characterizes the resonance by measuring the nonclassical spreading of the averaged beam signal. Left-hand circularly polarized SAWs resonate with the fast ions but right-hand circularly polarized SAWs do not. The measured fast-ion profiles are compared with simulations by a Monte Carlo Lorentz code that uses the measured wave field data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma And Beam Homogeneity Of The RF-Driven Negative Hydrogen Ion Source For ITER NBI

The neutral beam injection (NBI) system of ITER is based on a large RF driven negative hydrogen ion source. For good beam transmission ITER requires a beam homogeneity of better than 10%. The plasma uniformity and the correlation with the beam homogeneity are being investigated at the prototype ion sources at IPP. Detailed studies are carried out at the long pulse test facility MANITU with a source of roughly 1/8 of the ITER source size. The plasma homogeneity close to plasma grid is measured by optical emission spectroscopy and by fixed Langmuir probes working in the ion saturation region. The beam homogeneity is measured with a spatially resolved H{sub {alpha}} Doppler-shifted beam spectroscopy system. The plasma top-to-bottom symmetry improves with increasing RF power and increasing bias voltage which is applied to suppress the co-extracted electron current. The symmetry is better in deuterium than in hydrogen. The boundary layer near the plasma grid determines the plasma symmetry. At high ion currents with a low amount of co-extracted electrons the plasma is symmetrical and the beam homogeneity is typically 5-10%(RMS). The size scaling and the influence of the magnetic field strength of the filter field created by a plasma grid current is studied at the test facility RADI (roughly a 1/2 size ITER source) at ITER relevant RF power levels. In volume operation in deuterium (non-cesiated source), the plasma illumination of the grid is satisfying.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of a Source of Quasi-Monochromatic MeV Energy Photons

We report current progress on a project to develop an all-optically-driven x-ray photon source. A laser pulse with 40-50 TW of peak power is focused on a supersonic helium nozzle to drive a relativistic plasma wave. Electron beams with energies of 320 MeV (+/-28 MeV) are accelerated by means of laser wakefield acceleration. Remarkably, the acceleration region is only 3 mm in length. This accelerator is currently being employed to demonstrate the generation of MeV-energy x-ray by means of all-optical Thomson scattering. By this mechanism, a lower power, laser pulse (from the same laser system) is focused onto the above laser-driven electron beam, 1-eV energy photons are Doppler-shifted in energy to >1 MeV.

43 PARTICLE ACCELERATORS↗