Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detectors Instrumentation Imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Hard X-ray imaging survey of the Galactic plane with the Caltech gamma-ray imaging payload GRIP-2

In a two-day balloon flight during October 1995, the Caltech coded aperture gamma ray imaging payload (GRIP-2) imaged various fields in the Galactic plane and center in the 25 to 600 keV energy band. The large phoswich detector, the 15 deg field of view, the 30 arcmin angular resolution and 6 arcmin point source localization capability of GRIP-2 provides the possibility of surveying the accreting binary population of the Galaxy at high energy. The instrument is described and preliminary imaging results are reported on. The capabilities of this instrument for hard X-ray/gamma ray imaging are demonstrated.

Corbel, S.↗

Reflectivity of VUV-sensitive silicon photomultipliers in liquid Xenon

Silicon photomultipliers are regarded as a very promising technology for next-generation, cutting-edge detectors for low-background experiments in particle physics. This work presents systematic reflectivity studies of Silicon Photomultipliers (SiPM) and other samples in liquid xenon at vacuum ultraviolet (VUV) wavelengths. A dedicated setup at the University of Münster has been used that allows to acquire angle-resolved reflection measurements of various samples immersed in liquid xenon with 0.45° angular resolution. Four samples are investigated in this work: one Hamamatsu VUV4 SiPM, one FBK VUV-HD SiPM, one FBK wafer sample and one Large-Area Avalanche Photodiode (LA-APD) from EXO-200. Here, the reflectivity is determined to be 25–36 % at an angle of incidence of 20° for the four samples and increases to up to 65 % at 70° for the LA-APD and the FBK samples. The Hamamatsu VUV4 SiPM shows a decline with increasing angle of incidence. The reflectivity results will be incorporated in upcoming light response simulations of the nEXO detector.

(pin diodes, APDs, SiPMs, G-APDs, CCDs, EBCCDs, EM↗

Advanced Land Imager Assessment System

The Advanced Land Imager Assessment System (ALIAS) supports radiometric and geometric image processing for the Advanced Land Imager (ALI) instrument onboard NASA s Earth Observing-1 (EO-1) satellite. ALIAS consists of two processing subsystems for radiometric and geometric processing of the ALI s multispectral imagery. The radiometric processing subsystem characterizes and corrects, where possible, radiometric qualities including: coherent, impulse; and random noise; signal-to-noise ratios (SNRs); detector operability; gain; bias; saturation levels; striping and banding; and the stability of detector performance. The geometric processing subsystem and analysis capabilities support sensor alignment calibrations, sensor chip assembly (SCA)-to-SCA alignments and band-to-band alignment; and perform geodetic accuracy assessments, modulation transfer function (MTF) characterizations, and image-to-image characterizations. ALIAS also characterizes and corrects band-toband registration, and performs systematic precision and terrain correction of ALI images. This system can geometrically correct, and automatically mosaic, the SCA image strips into a seamless, map-projected image. This system provides a large database, which enables bulk trending for all ALI image data and significant instrument telemetry. Bulk trending consists of two functions: Housekeeping Processing and Bulk Radiometric Processing. The Housekeeping function pulls telemetry and temperature information from the instrument housekeeping files and writes this information to a database for trending. The Bulk Radiometric Processing function writes statistical information from the dark data acquired before and after the Earth imagery and the lamp data to the database for trending. This allows for multi-scene statistical analyses.

Chander, Gyanesh↗

The Design and Integrated Performance of SPT-3G

Abstract SPT-3G is the third survey receiver operating on the South Pole Telescope dedicated to high-resolution observations of the cosmic microwave background (CMB). Sensitive measurements of the temperature and polarization anisotropies of the CMB provide a powerful data set for constraining cosmology. Additionally, CMB surveys with arcminute-scale resolution are capable of detecting galaxy clusters, millimeter-wave bright galaxies, and a variety of transient phenomena. The SPT-3G instrument provides a significant improvement in mapping speed over its predecessors, SPT-SZ and SPTpol. The broadband optics design of the instrument achieves a 430 mm diameter image plane across observing bands of 95, 150, and 220 GHz, with 1.2′ FWHM beam response at 150 GHz. In the receiver, this image plane is populated with 2690 dual-polarization, trichroic pixels (∼16,000 detectors) read out using a 68× digital frequency-domain multiplexing readout system. In 2018, SPT-3G began a multiyear survey of 1500 deg 2 of the southern sky. We summarize the unique optical, cryogenic, detector, and readout technologies employed in SPT-3G, and we report on the integrated performance of the instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implanted Silicon Resistor Layers for Efficient Terahertz Absorption

Broadband absorption structures are an essential component of large format bolometer arrays for imaging GHz and THz radiation. We have measured electrical and optical properties of implanted silicon resistor layers designed to be suitable for these absorbers. Implanted resistors offer a low-film-stress, buried absorber that is robust to longterm aging, temperature, and subsequent metals processing. Such an absorber layer is readily integrated with superconducting integrated circuits and standard micromachining as demonstrated by the SCUBA II array built by ROE/NIST (1). We present a complete characterization of these layers, demonstrating frequency regimes in which different recipes will be suitable for absorbers. Single layer thin film coatings have been demonstrated as effective absorbers at certain wavelengths including semimetal (2,3), thin metal (4), and patterned metal films (5,6). Astronomical instrument examples include the SHARC II instrument is imaging the submillimeter band using passivated Bi semimetal films and the HAWC instrument for SOFIA, which employs ultrathin metal films to span 1-3 THz. Patterned metal films on spiderweb bolometers have also been proposed for broadband detection. In each case, the absorber structure matches the impedance of free space for optimal absorption in the detector configuration (typically 157 Ohms per square for high absorption with a single or 377 Ohms per square in a resonant cavity or quarter wave backshort). Resonant structures with -20% bandwidth coupled to bolometers are also under development; stacks of such structures may take advantage of instruments imaging over a wide band. Each technique may enable effective absorbers in imagers. However, thin films tend to age, degrade or change during further processing, can be difficult to reproduce, and often exhibit an intrinsic granularity that creates complicated frequency dependence at THz frequencies. Thick metal films are more robust but the requirement for patterning can limit their absorption at THz frequencies and their heat capacity can be high. patterned absorber structures that offer low heat capacity, absence of aging, and uniform, predictable behavior at THz frequencies. We have correlated DC electrical and THz optical measurements of a series of implanted layers and studied their frequency dependence of optical absorption from .3 to 10 THz at cryogenic temperatures. We have modeled the optical response to determine the suitability of the implanted silicon resistor as a function of resistance in the range 10 Ohms/sq to 300 Ohms/sq.

Chervenak, J. A.↗

Determination of X-ray detection limit and applications in perovskite X-ray detectors

X-ray detection limit and sensitivity are important figure of merits for perovskite X-ray detectors, but literatures lack a valid mathematic expression for determining the lower limit of detection for a perovskite X-ray detector. In this work, we present a thorough analysis and new method for X-ray detection limit determination based on a statistical model that correlates the dark current and the X-ray induced photocurrent with the detection limit. The detection limit can be calculated through the measurement of dark current and sensitivity with an easy-to-follow practice. Alternatively, the detection limit may also be obtained by the measurement of dark current and photocurrent when repeatedly lowering the X-ray dose rate. While the material quality is critical, we show that the device architecture and working mode also have a significant influence on the sensitivity and the detection limit. Our work establishes a fair comparison metrics for material and detector development.

47 OTHER INSTRUMENTATION↗

Highly Extensible X-ray Diffraction Toolkit

This code has been previous released as open source under LLNL-CODE-529294. The HEXRD program comprises a library of X-ray diffraction analysis tools and a stand-alone GUI application. While there are many software packages that provide similar capabilities, HEXRD was designed to provide an extremely flexible and extensible basis for describing a broad array of X-ray diffraction instruments; this includes both mono- and poly-chromatic modalities as well as poly- and single-crystal samples. The high-level objects include Material: an abstraction for defining crystalline materials, including unit cell parameters and anisotropic elastic moduli Imageseries: an interface for series of diffraction images containing one or more frames, including provisions for metadata. Instrument: an abstraction of an X-ray diffraction instrument including support for the definition of multiple detector elements as well as powder, Laue, and mono-chromatic single/multi-grain diffraction analysis modalities (including attendant calibration routines). The hexrdgui package is a standalone PySide2/Qt5 GUI built on top of hexrd. The 0.8.1 release includes various bug fixes as well as some new functionality in the GUI, including: o Enhancements to the import tools for LLNL diffraction instruemtns (PXRDIP and TARDIS) o The ability to save 1-d LeBail fits of integrated diffraction spectra.

Barton, NathanR.↗

Gamma-ray bursters

Current theoretical models developed to explain the observational data (from spaceborne detectors) on gamma-ray bursters are summarized and illustrated with drawings, diagrams, graphs, and photographic images. Although the data are fragmentary and often flawed by instrument defects, models involving neutron stars with strong magnetic fields are generally favored, and it is assumed that most observed bursters lie within the Galaxy. The neutron-star origin of the bursts is suggested by their intensity and rapid variability (implying a very compact high-energy source) and the presence in some burster spectra of a line at 420 keV which is explained by the combination of electron-positron annihilation and gravitational reddening. Consideration is also given to optical flashes observed to occur about once per year in the direction of gamma bursters, and the need for further searches for lower-energy emissions from bursters is stressed.

Schaefer, B. E.↗

Sounding rockets shot from the Shuttle

The Space Shuttle-launched sounding rocket Spartan-1 will map the structure of two extended X-ray sources: the hot gas pervading the Perseus cluster of galaxies, and the central core of the Milky Way. Spartan-1 contains two large X-ray proportional counter detectors sensitive to the 1-15 A wavelength range. A new generation of instruments destined for X-ray telescope focal planes will yield high resolution imaging and spectroscopy, over observation times sometimes exceeding one day/source, in the course of a long-term Spartan research program that will encompass planetary, solar, and UV astronomy missions.

Cruddace, R.↗

Gamma-ray burst and spectroscopy instrumentation development at the Goddard Space Flight Center

This paper summarizes the activities that are specifically related to the development of instrumentation for gamma-ray astronomy. Three programs are described: (1) the Gamma-Ray Imaging Spectrometer (GRIS), a balloon-borne array of seven germanium detectors for high-resolution spectrographic studies of persistent gamma-ray sources; (2) the Transient Gamma-Ray Spectrometer (TGRS), a single radiatively-cooled germanium detector for the spectrographic study of gamma-ray bursts, and (3) the Rapidly Moving Telescope (RMT), a ground-based optical telescope for the detection and study of short-lived optical transients, particularly those that occur in coincidence with gamma-ray bursts.

Teegarden, B. J.↗

The evaluation of a deformable diffraction grating for a stigmatic EUV spectroheliometer

A high-efficiency, extreme ultraviolet (EUV) imaging spectrometer is constructed and tested. The spectrometer employs a concave toroidal grating illuminated at normal incidence in a Rowland circle mounting and has only one reflecting surface. The toroidal grating has been fabricated by a new technique employing an elastically-deformable sub-master grating replicated in a spherical form and then mechanically distorted to produce the desired aspect ratio of the toroidal surface for stigmatic imaging over the selected wavelength range. The fixed toroidal grating used in the spectrometer is then replicated from this surface. Photographic tests and initial photoelectric tests with a two-dimensional, pulse-counting detector system verify the image quality of the toroidal grating at wavelengths near 600 A. The results of these tests and the basic designs of two instruments which could employ the imaging spectrometer for astrophysical investigations in space are described; i.e., a high-resolution EUV spectroheliometer for studies of the solar chromosphere, transition region, and corona; and an EUV spectroscopic telescope for studies of non-solar objects.

Timothy, J. G.↗

Results from Source-Based and Detector-Based Calibrations of a CLARREO Calibration Demonstration System

The Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission is formulated to determine long-term climate trends using SI-traceable measurements. The CLARREO mission will include instruments operating in the reflected solar (RS) wavelength region from 320 nm to 2300 nm. The Solar, Lunar for Absolute Reflectance Imaging Spectroradiometer (SOLARIS) is the calibration demonstration system (CDS) for the reflected solar portion of CLARREO and facilitates testing and evaluation of calibration approaches. The basis of CLARREO and SOLARIS calibration is the Goddard Laser for Absolute Measurement of Response (GLAMR) that provides a radiance-based calibration at reflective solar wavelengths using continuously tunable lasers. SI-traceability is achieved via detector-based standards that, in GLAMRs case, are a set of NIST-calibrated transfer radiometers. A portable version of the SOLARIS, Suitcase SOLARIS is used to evaluate GLAMRs calibration accuracies. The calibration of Suitcase SOLARIS using GLAMR agrees with that obtained from source-based results of the Remote Sensing Group (RSG) at the University of Arizona to better than 5 (k2) in the 720-860 nm spectral range. The differences are within the uncertainties of the NIST-calibrated FEL lamp-based approach of RSG and give confidence that GLAMR is operating at 5 (k2) absolute uncertainties. Limitations of the Suitcase SOLARIS instrument also discussed and the next edition of the SOLARIS instrument (Suitcase SOLARIS- 2) is expected to provide an improved mechanism to further assess GLAMR and CLARREO calibration approaches. (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

Angal, Amit↗

Fabricating Sub-Collimating Grids for an X-Ray Solar Imaging Spectrometer Using LIGA Techniques

A proposed NASA mission uses a High Energy Solar Spectroscopic Imager (HESSI) to image solar X-rays. The HESSI instrument consists of twelve rotating pairs of high aspect ratio, high Z grids, each pair of which is separated by 1.7 meters and backed by a single Ge detector. Discussed are the fabrication of these proof-of-concept sub-collimating X-ray grids which are to be used in HESSI.

solar↗

Capabilities, Performance, and Status of the SOFIA Science Instrument Suite

The Stratospheric Observatory for Infrared Astronomy (SOFIA) is an airborne observatory, carrying a 2.5 m telescope onboard a heavily modified Boeing 747SP aircraft. SOFIA is optimized for operation at infrared wavelengths, much of which is obscured for ground-based observatories by atmospheric water vapor. The SOFIA science instrument complement consists of seven instruments: FORCAST (Faint Object InfraRed CAmera for the SOFIA Telescope), GREAT (German Receiver for Astronomy at Terahertz Frequencies), HIPO (High-speed Imaging Photometer for Occultations), FLITECAM (First Light Infrared Test Experiment CAMera), FIFI-LS (Far-Infrared Field-Imaging Line Spectrometer), EXES (Echelon-Cross-Echelle Spectrograph), and HAWC (High-resolution Airborne Wideband Camera). FORCAST is a 540 m imager with grism spectroscopy, developed at Cornell University. GREAT is a heterodyne spectrometer providing high-resolution spectroscopy in several bands from 60240 m, developed at the Max Planck Institute for Radio Astronomy. HIPO is a 0.31.1 m imager, developed at Lowell Observatory. FLITECAM is a 15 m wide-field imager with grism spectroscopy, developed at UCLA. FIFI-LS is a 42210 m integral field imaging grating spectrometer, developed at the University of Stuttgart. EXES is a 528 m high-resolution spectrograph, developed at UC Davis and NASA ARC. HAWC is a 50240 m imager, developed at the University of Chicago, and undergoing an upgrade at JPL to add polarimetry capability and substantially larger GSFC detectors. We describe the capabilities, performance, and status of each instrument, highlighting science results obtained using FORCAST, GREAT, and HIPO during SOFIA Early Science observations conducted in 2011.

SOFIA↗

The LXeCAT instrument for gamma-ray astrophysics

The Liquid Xenon Coded Aperture Telescope (LXeCAT) and its capability to image astrophysical gamma-ray sources in the MeV region is described. The gamma-ray detector is a Liquid Xenon Time Projection Chamber (LXeTPC) triggered by the primary scintillation light. Effective background rejection is a direct consequence of the intrinsic three-dimensional imaging capability of the LXeTPC. Initial results with a 10 liter prototype confirm an energy resolution of 6% FWHM, a position resolution of 1 mm RMS and a light triggering efficiency higher than 90% for 1 MeV gamma-rays.

Aprile, E.↗

Development of a synthetic phase contrast imaging diagnostic for turbulence studies at Wendelstein 7-X

Abstract We present a synthetic phase contrast imaging (PCI) diagnostic for studying turbulence at the Wendelstein 7-X (W7-X) stellarator. We first describe the implemented instrument response model, which captures diffraction effects, detector noise, and the long-wavelength cutoff due to the phase plate of the PCI system. To verify the instrument response model, we show that it is capable of reproducing the PCI signal generated by the sound wave speaker used for calibration at W7-X. Next, we discuss the calculation of synthetic PCI signals based on the global, nonlinear gyrokinetic codes GENE-3D and EUTERPE, including results from some of the first stellarator simulations of this type with kinetic electrons (KEs) in GENE-3D. While the simulations used in this work lack a neoclassical radial electric field, which is crucial for reproducing experimental PCI signals, they do indicate that the dominant rotation direction and velocities of the turbulent fluctuations can be inferred from the wave number-frequency spectra of the PCI signals, as expected. The synthetic PCI wave number spectra are further shown to be similar to those of the line-integrated fluctuating electron density, with distinct differences between adiabatic and KE simulations, explainable by previously published turbulence models. For example, the wave number spectra of all adiabatic electron simulations analyzed here follow a power law with an exponent close to −5 for sufficiently large wave numbers. This indicates that universal features of electron density turbulence at W7-X may be studied using the PCI system.

EUTERPE↗

The Design and Performance of the 384: Element Submillimeter Detector Array for SHARC II

We report on the performance of the SHARC II detector, a 12 x 32 array of ion implanted Si pop-up bolometers. This 384 element detector array was built as a prototype for the High Angular Resolution Widefield Camera (HAWC) for the Stratospheric Observatory for Infrared Astronomy (SOFIA). We will discuss the design process, the characterization of the detectors, and the performance of the array in the SHARC II instrument. SHARC II is now a facility instrument on the Caltech Submillimeter Observatory, providing background-limited imaging at 350 and 450 microns.

Moseley, Samuel H.↗

Technical Aspects of the Space Telescope Imaging Spectrograph Repair (STIS-R)

In August 2004, the Hubble Space Telescope (HST) Space Telescope Imaging Spectrograph (STIS) ceased operation, due to a failure in the Side 2 Low Voltage Power Supply (LVPS2). LVPS2 provided power to the entire instrument, including all detectors and mechanisms. Following the LVPS2 failure, a team was assembled to analyze the fault and to determine if STIS repair (STIS-R) was feasible. The team concluded that by replacing a power supply board within LVPS2, STIS could be brought back to full functionality. STIS-R will be conducted during Servicing Mission 4 (SM4), and will consist of replacing the power supply board and a new passive cooling system. STIS-R will restore full function of the instrument with one of the two redundant sides of the instrument. In this presentation, we focus on the technical aspects associated with STISR.

Rinehart, Stephen↗