Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DUCTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

On the onset of secondary flow and unsteady solutions through a loosely coiled rectangular duct for large aspect ratio

The study of flows through coiled ducts and channels has attracted considerable attention not only because of their ample applications in Chemical, Mechanical, Civil, Nuclear and Biomechanical engineering but also because of their ample applications in other areas, such as blood flow in the veins and arteries of human and other animals. In this paper, a numerical study is presented for the fully developed two-dimensional flow of viscous incompressible fluid through a loosely coiled rectangular duct of large aspect ratio. Numerical calculations are carried out by using a spectral method, and covering a wide range of the Dean number, Dn, for two types of curvatures of the duct. The main concern of the present study is to find out effects of curvature as well as formation of secondary vortices on unsteady solutions whether the unsteady flow is steady-state, periodic, multi-periodic or chaotic, if Dn is increased. Time evolution calculations as well as their phase spaces are performed with a view to study the non-linear behavior of the unsteady solutions, and it is found that the steady-state flow turns into chaotic flow through various flow instabilities, if Dn is increased no matter what the curvature is. It is found that the unsteady flow is a steady-state solution for small Dn’s and oscillates periodically or non-periodically (chaotic) between two- and twelve-vortex solutions, if Dn is increased. It is also found that the chaotic solution is weak for small Dn’s but strong as Dn becomes large. Axial flow distribution is also investigated and shown in contour plots.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Whistler waves guided by density depletion ducts in a magnetoplasma

The guided propagation of whistler waves along cylindrical density depletion ducts in a magneto-plasma is studied. It is shown that, under certain conditions, such ducts can support volume and surface eigenmodes. The dispersion properties and field structure of whistler modes guided by density depletion ducts are analyzed. The effect of collisional losses in the plasma on the properties of modes is discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Waves guided by density ducts in magnetoplasma in the nonresonant region of the whistler frequency range

Guidance of azimuthally symmetric waves by cylindrical density ducts in magnetoplasma in the nonresonant region of the whistler frequency range is investigated. It is demonstrated that eigenmodes existing at the studied frequencies in ducts with enhanced plasma density allow simplified description that makes analysis of the features of their guided propagation much easier. The results of calculation of the dispersion characteristics and field structure of the whistler modes supported by such ducts are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of ducted fuel injection at high-pressure transcritical conditions using large-eddy simulations

Ducted fuel injection (DFI) is a proposed fuel injection concept for achieving substantial reductions in emissions. In this concept, the fuel is injected through a coannular duct, resulting in increased fuel-air mixing and minimized formation of soot and other unwanted combustion products. Apart from comprehensive experimental investigations on DFI, so far computational studies have been limited to single-point Reynolds-averaged Navier Stokes simulations. Therefore, the objective of this work is to complement these studies by performing large-eddy simulations using a diffuse-interface method to examine the physical mechanisms and combustion processes of DFI, specifically focusing on the mixing process and the effect of fuel-ducting on combustion and pollutant emissions. To this end, finite-rate chemistry simulations are performed of the DFI configuration corresponding to the Engine Combustion Network Spray A injector at transcritical conditions (n-dodecane fuel, 60 bar pressure and 1000 K temperature chamber conditions). A two-equation soot model is employed for the qualitative analysis of soot emissions. Direct comparisons of averaged and instantaneous flow field results with the Spray A configuration are performed to assess the effect of DFI on the first- and second-stage ignition and soot formation. Compared to the free-spray condition, the results show that the DFI case exhibits a combination of (i) increased mass flow rate and entrained air, (ii) larger pressure drop magnitude and flow velocity, and (iii) a closer-to-stoichiometric mixture composition (both globally and locally), each of which is conjectured to contribute toward reduced soot production.

33 ADVANCED PROPULSION SYSTEMS↗

Energy Savings and Peak Demand Reduction of a SEER 21 Heat Pump vs. a SEER 13 Heat Pump with Attic and Indoor Duct Systems

This report describes results of experiments that were conducted in an unoccupied 1600 square foot house--the Manufactured Housing (MH Lab) at the Florida Solar Energy Center (FSEC)--to evaluate the delivered performance as well as the relative performance of a SEER 21 variable capacity heat pump versus a SEER 13 heat pump. The performance was evaluated with two different duct systems: a standardattic duct system and an indoor duct system located in a dropped-ceiling space.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hydrogen Storage for Load-Following and Clean Power: Duct-firing of Hydrogen to Improve the Capacity Factor of NGCC Plants (Final Report, Phase II Pre-Front End Engineering Design Study)

GTI Energy (GTI) and team members Southern Company Services (SCS), Pacific Gas & Electric (PG&E) and the Electric Power Research Institute (EPRI) performed a Phase II Pre-Feed Study under contract DE-FE0032008 for Hydrogen Storage for Load-Following and Clean Power. The configuration of the proposed system consists of subsystems for on-site H 2 production, on-site H 2 storage (up to 54 MWth in commercial vessels) and H 2 combustion in a duct burner in a Heat Recovery Steam Generator (HRSG) integrated with an existing fossil asset. Here, the firing rate of the duct burner is varied to let the plant respond to fluctuations of electrical load and H 2 production is relatively constant by storing H 2 . The proposed system is an improvement over alternate low carbon dispatchable power options. Technoeconomic analyses show H 2 produced with GTI’s patented Compact Hydrogen Generator (CHG) with inherent carbon capture will be lower cost (Levelized Cost of Hydrogen, LCOH) relative to hydrogen produced with a Steam Methane Reformer (SMR) with an amine system for carbon capture. This lower cost hydrogen enables our integrated system to deliver electricity (Levelized Cost of Electricity, LCOE) at 17.4% lower cost relative to a SMR sourced H 2 -fired HRSG (with an amine system for carbon capture) – Steam Turbine Generator (STG). Our analysis using EPRI’s US REGEN macroeconomic model shows our system will have significant demand in the power market and therefore require significant capacity expansion (CHG plants built to deliver hydrogen) to deliver low cost, low carbon power. In Phase II, our Team has completed a detailed system definition including the development of process models, definition of battery limits, Process Flow Diagrams (PFDs), Piping and Instrumentation Drawings (P&IDs), and a plant layout. A preliminary design for the key components of the CHG was developed including component lists & specifications. An evaluation of environmental and permitting considerations was completed and included the development of an Environmental Information Volume (EIV). The duct burners, which are flexible and can burn hydrogen and/or natural gas, were defined and initial CFD analyses were completed.

03 NATURAL GAS↗

Source Diagnostic Fan II (22-inch) Duct Mode Characteristics as Measured by the Rotating Rake Mode Measurement System while Operated in the NASA Glenn 9x15 Low Speed Wind Tunnel

The second entry of the Source Diagnostic Test (SDT2) was a continuation of the first SDT entry with additional parameters tested. The rotor, stators, and general flow path hardware used in SDT2 were the same as those for SDT1. This included a radial baseline set of stator vanes, which had a vane count such that the rotor-stator interaction at the fan blade passing fundamental was cut-off, as is typical for modern turbofans. Two sets of stator vanes were designed and tested with a count generating a cut-on rotor-stator interaction at the fan blade passing fundamental. One of the sets maintained the no aerodynamic sweep as the radial baseline, the other was designed with leading edge sweep with the intent to generate lower noise. The NASA Glenn Research Center’s Rotating Rake Mode Measurement System was utilized to obtain a complete map of the acoustic duct modes present. The system is a radial rake immersed into the duct that continuously rotates about the duct centerline. For each of the three stator vane configurations, data were acquired at several different fan speeds which included nominal, approach, cutback, and takeoff conditions. Analysis of the mode power level results at the fan fundamentals showed the improved designed set resulted in lower rotor-stator interaction mode acoustic levels. Multiple-pure tones generated by the M5 rotor in the inlet were also measured.

Turbofan, Duct Modes↗

Source Diagnostic Fan II (22-inch) Duct Mode Characteristics as Measured by the Rotating Rake Mode Measurement System while Operated in the NASA Glenn 9x15 Low Speed Wind Tunnel

The second entry of the Source Diagnostic Test (SDT2) was a continuation of the first SDT entry with additional parameters tested. The rotor, stators, and general flow path hardware used in SDT2 were the same as those for SDT1. This included a radial baseline set of stator vanes, which had a vane count such that the rotor-stator interaction at the fan blade passing fundamental was cut-off, as is typical for modern turbofans. Two sets of stator vanes were designed and tested with a count generating a cut-on rotor-stator interaction at the fan blade passing fundamental. One of the sets maintained the no aerodynamic sweep as the radial baseline, the other was designed with leading edge sweep with the intent to generate lower noise. The NASA Glenn Research Center’s Rotating Rake Mode Measurement System was utilized to obtain a complete map of the acoustic duct modes present. The system is a radial rake emersed into the duct that continuously rotates about the duct centerline. For each of the three stator vane configurations, data were acquired at several different fan speeds which included nominal, approach, cutback, and takeoff conditions. Analysis of the mode power level results at the fan fundamentals showed the improved designed set resulted in lower rotor-stator interaction mode acoustic levels. Multiple-pure tones generated by the M5 rotor in the inlet were also measured.

Turbofan↗

Acoustic Mode Decomposition in Rectangular Ducts with Sheared Flow

The performance of new acoustic liner concepts are, in general, characterized and assessed in grazing flow rigs early in the development cycle. These test rigs expose an acoustic liner sample, installed on the side wall of the duct, to a grazing flow and incident acoustic field. The process to characterize these liners involves educing the impedance on the wall where the sample is installed and examining the acoustic power attenuation. Standard approaches to computing impedance or power attenuation generally consider only the effects of a 2D shear flow or uniform flow, on the acoustic field. In this study, the objective is to incorporate 3D shear flow effects in the analysis of acoustic mode attenuation in a rectangular duct flow rig. A modal analysis of microphone measurements obtained on the side walls of the duct upstream and downstream of the test section of the rig is developed. A Galerkin projection of the Pridmore-Brown equation is performed with Chebyshev basis functions in order to incorporate the effects of the Mach number profile on the computation of the axial wavenumber of each mode. Measurements of the Mach number profile are obtained in the test rig and used as input to compute the modes. Comparisons made between the sound field computed with traditional convective Helmholtz modes and the new procedure using Pridmore-Brown modes indicate that the computed acoustic field using Pridmore-Brown modes more accurately reconstructs the acoustic signal at each microphone in the array. The mode structure of the lowest-order mode is shown to be significantly impacted by shear flow refraction effects, and higher-order mode structures are also affected at higher frequencies and centerline Mach number. An assessment of the acoustic mode attenuation for two acoustic liner samples demonstrates that the computed mode amplitudes for both the traditional and new approach are in agreement for the lowest-order mode, but discrepancies arise when higher-order modes are the dominant component of the acoustic field.

Duct acoustics↗

Acoustic Mode Decomposition in Rectangular Ducts with Sheared Flow

The performance of new acoustic liner concepts are, in general, characterized and assessed in grazing flow rigs early in the development cycle. These test rigs expose an acoustic liner sample, installed on the side wall of the duct, to a grazing flow and incident acoustic field. The process to characterize these liners involves educing the impedance on the wall where the sample is installed and examining the acoustic power attenuation. Standard approaches to computing impedance or power attenuation generally consider only the effects of a 2D shear flow or uniform flow, on the acoustic field. In this study, the objective is to incorporate 3D shear flow effects in the analysis of acoustic mode attenuation in a rectangular duct flow rig. A modal analysis of microphone measurements obtained on the side walls of the duct upstream and downstream of the test section of the rig is developed. A Galerkin projection of the Pridmore-Brown equation is performed with Chebyshev basis functions in order to incorporate the effects of the Mach number profile on the computation of the axial wavenumber of each mode. Measurements of the Mach number profile are obtained in the test rig and used as input to compute the modes. Comparisons made between the sound field computed with traditional convective Helmholtz modes and the new procedure using Pridmore-Brown modes indicate that the computed acoustic field using Pridmore-Brown modes more accurately reconstruct the acoustic signals at each microphone in the array. The mode structure of the lowest order mode is shown to be significantly impacted by shear flow refraction effects, and higher order mode structures are also effected at higher frequencies and centerline Mach number. An assessment of the acoustic mode attenuation for two acoustic liner samples demonstrates that the computed mode amplitudes for both the traditional and new approach are in agreement for the lowest order mode, but discrepancies arise when higher order modes are the dominant component of the acoustic field.

Duct acoustics↗

Clad and duct materials property needs for sodium fast reactors: US perspective

In the Advanced Fuel Cycle Initiative, the clad and duct materials property needs are driven by the program direction of using a fast reactor to transmute minor actinides. To economically perform transmutation requires fuels to be irradiated to at least 200/0 burnup before discharge and recycle. The cladding materials used in sllch high dose irradiations will experience at least 200 dpa of exposure. The requirements are that the cladding must contain the fuel until discharge and the duct must maintain ductility and mechanical strength to direct the sodium coolant and withdraw the fuel at discharge. Presently, achieving a bumup of 20% in fast reactor fuels is a significant challenge. The materials property needs for clad materials are the following in order of importance: (1) Radiation resistance: the material must be tolerant of radiation damage up to 200 dpa or greater depending on the final burnup desired at temperatures ranging from 350-600 C (temperature range for maximum dose is 400-500 C). Thus, the material must be tolerant of swelling, irradiation creep, and embrittlement effects. (2) Mechanical properties: tensile properties (strength, ductility), creep resistance, fracture toughness and fatigue resistance must all sufficient to contain the fuel during irradiation and discharge. (3) Fuel Clad Chemical Interaction: the cladding must be resistant to chemical interaction with the fuel during irradiation to prevent clad failure. (4) Fabrication and joining: the material must be able to be fabricated into component parts and joined to contain the fuel during the irradiation and during discharge. (5) Corrosion resistance: the material must be tolerant of the sodium coolant, with minimal corrosion rate. (6) Reprocessing: the cladding must be dissolvable to enable fuel reprocessing. (7) Long-term stability: the clad and duct materials must be stable through 6 or more years of irradiation depending on the final fuel burnup desired. (8) Thermal properties: thermal conductivity and thermal expansion are important to maintain desired fuel temperatures during irradiation. (9) Neutronic properties: low neutron absorption is required. (10) Material availability: enough raw material must be readily available. (11) Economics: the cost of the material must be considered but is not a significant driver.

36 MATERIALS SCIENCE↗

Compact Buried Ducts in a Hot-Humid Climate House

A system of compact, buried ducts provides a high-performance and cost-effective solution for delivering conditioned air throughout the building. This report outlines research activities that are expected to facilitate adoption of compact buried duct systems by builders. The results of this research would be scalable to many new house designs in most climates and markets, leading to wider industry acceptance and building code and energy program approval.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Endoluminal Intervention in the Salivary Duct: Clinical Outcomes at a District General Hospital

Our aim was to assess the preliminary clinical outcomes of interventional radiology for salivary duct obstruction in relation to salivary duct strictures or calculi. A retrospective analysis of consecutive patients referred for endoluminal procedures by ENT surgeons during a 4-year period were identified. The procedure was performed by a single interventional radiologist under fluoroscopic guidance using wire baskets and angioplasty balloons. Between June 2004 and October 2008, 50 sialoplasties were performed in 43 patients (30 female and 13 male). Twenty-six patients were prepared for 32 procedures for extraction of calculi (13 submandibular and 13 parotid), and 17 patients had 18 procedures for strictures (16 parotid and 1 submandibular). One patient in the group with calculi was judged unsuitable for intervention because the stone had migrated outside the salivary duct. Information was collected regarding the clinical indication; duration and type of symptoms; technical factors; follow-up; and success or failure of reintervention. Complete stone removal was achieved in 18 of the 26 patients (69%), with success on the first attempt in 14 patients (54%). Redo procedures were required in 4 patients (15%), with subsequent complete clearance of calculi. In this cohort, 20 patients were symptomatically improved (77%). Of the 6 patients (26%) with continuing symptoms, 2 patients had mild symptoms; two had moderate symptoms; and two patients opted to have surgery for unremitting symptoms. In the stricture group, 18 procedures were performed in 17 patients, with a successful outcome in 16 patients after the initial sialoplasty. Only 1 patient required repeat intervention (6%) and later opted to have surgery for continuing symptoms. In this group, 14 patients (82%) were symptomatically improved, and 3 remained symptomatic despite a good immediate result due to restenosis. Two patients experienced early complications: One had a transient facial nerve palsy, and the other had sialadenitis treated with antibiotics. Preliminary results suggest that symptom resolution at first intervention is higher in patients with acalculous strictures. Patients with calculi are more likely to require a repeat procedure for complete clearance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Acetic Acid Sclerotherapy for Treatment of a Bile Leak from an Isolated Bile Duct After Laparoscopic Cholecystectomy

Bile leak after laparoscopic cholecystectomy is not uncommon, and it mainly occurs from the cystic duct stump and can be easily treated by endoscopic techniques. However, treatment for leakage from an isolated bile duct can be troublesome. We report a successful case of acetic acid sclerotherapy for bile leak from an isolated bile duct after laparoscopic cholecystectomy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transarterial Chemoembolization for Hepatocellular Carcinomas with Central Bile Duct Invasion: Safety, Prognosis, and Predictive Factors

PurposeTo assess the safety and effectiveness of transarterial chemoembolization (TACE) of patients who have hepatocellular carcinomas (HCCs) with central bile duct invasion.Materials and MethodsThe institutional review board approved this retrospective study and waived informed consent. Fifty-three patients, initially treated with TACE for HCCs with central bile duct invasion from January 1999 to September 2012, were included. Clinical, laboratory, and survival data were reviewed. Complications and hospitalization length were evaluated using the χ{sup 2} test, Fisher’s exact test, and logistic regression analysis. Survival was analyzed using the Kaplan–Meier method with log-rank test and Cox proportional hazard model.ResultsSeven patients experienced TACE-related major complications (severe post-embolization syndrome in 3, non-fatal sepsis in 3, and secondary bacterial peritonitis in 1). The overall major complication rate was 13.2 %, but there were no permanent adverse sequelae or deaths within 30 days. Serum total bilirubin ≥3.0 mg/dL was the only significant risk factor for long hospitalization [hazard ratio (HR) = 4.341, p = .022]. The median survival was 12.2 months. Extrahepatic metastasis (HR = 6.145, p < .001), international normalized ratio (PT-INR) ≥1.20 (HR = 4.564, p < .001), vascular invasion (HR = 3.484, p = .001), and intermediate tumor enhancement (HR = 2.417, p = .019) were significantly associated with shorter survival.ConclusionTACE can be a safe and effective treatment for patients who have HCCs with central bile duct invasion. In particular, long-term survival can be expected if patients have strongly enhancing tumors without poor prognostic factors such as extrahepatic metastasis, PT-INR prolongation, and vascular invasion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Matrix metalloproteinase-14 mediates formation of bile ducts and hepatic maturation of fetal hepatic progenitor cells

Fetal hepatic stem/progenitor cells, called hepatoblasts, play central roles in liver development; however, the molecular mechanisms regulating the phenotype of these cells have not been completely elucidated. Matrix metalloproteinase (MMP)-14 is a type I transmembrane proteinase regulating pericellular proteolysis of the extracellular matrix and is essential for the activation of several MMPs and cytokines. However, the physiological functions of MMP-14 in liver development are unknown. Here we describe a functional role for MMP-14 in hepatic and biliary differentiation of mouse hepatoblasts. MMP-14 was upregulated in cells around the portal vein in perinatal stage liver. Formation of bile duct-like structures in MMP-14–deficient livers was significantly delayed compared with wild-type livers in vivo. In vitro biliary differentiation assays showed that formation of cholangiocytic cysts derived from MMP-14–deficient hepatoblasts was completely impaired, and that overexpression of MMP-14 in hepatoblasts promoted the formation of bile duct-like cysts. In contrast, the expression of molecules associated with metabolic functions in hepatocytes, including hepatic nuclear factor 4α and tryptophan 2,3-dioxygenase, were significantly increased in MMP-14–deficient livers. Expression of the epidermal growth factor receptor and phosphorylation of mitogen-activated protein kinases were significantly upregulated in MMP-14–deficient livers. We demonstrate that MMP-14–mediated signaling in fetal hepatic progenitor cells promotes biliary luminal formation around the portal vein and negatively controls the maturation of hepatocytes. - Highlights: • Loss of MMP-14 delayed formation of bile duct-like structures in perinatal liver. • Overexpression of MMP-14 in hepatobalsts promoted the biliary formation in vitro. • Loss of MMP-14 promoted hepatocyte maturation of hepatoblasts in vivo. • MMP-14–mediated signaling regulates terminal differentiation of hepatoblasts.

60 APPLIED LIFE SCIENCES↗

Effect of the length of the poloidal ducts on flow balancing in a liquid metal blanket

To address concerns associated with liquid metal (LM) flow balancing among multiple poloidal channels of a LM blanket, we investigate the factors (first of all the length of the channels) that influence the flow distribution when the duct walls are electrically insulated. We simulate LM MHD flow through multiple channels fed by a prototypical manifold for a range of channel lengths using a 3D MHD solver, HIMAG. The simplified manifold geometry consists of a rectangular, electrically insulated feeding duct which suddenly expands such that the duct thickness in the magnetic field direction abruptly increases by a factor of 4. After a short length downstream of the expansion, the flow is divided into three identical parallel channels. By measuring the flow rate in each of the channels, we conclude that flow balance among the channels is improved by increasing the length of the channels. An effort is made to obtain scaling laws that characterize flow balancing as a function of the flow parameters and the manifold geometry using a Resistor Network Model (RNM). Associated Hartman and Reynolds numbers in the computations were ~10 3 and 10 2 respectively. Compared to the full 3D analysis, the proposed RNM suggests a relatively quick and simpler way of computing the blanket length that might be needed to provide balanced flow among the parallel channels.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

3D modelling of MHD mixed convection flow in a vertical duct with transverse magnetic field and volumetric or surface heating

Understanding phenomena associated with the multiple effects/interactions of the fusion nuclear environment on liquid metal flow is required to correctly design liquid metal (LM) blankets for fusion facilities. These effects are investigated in the present work by numerically simulating 3D LM MHD flow. The simulated geometry consists of a straight, vertical duct which runs perpendicular to a strong, fringing applied magnetic field. There is also a region of applied heating as the primary goal is to explore buoyancy effects in MHD duct flows. Results are presented for both buoyancy assisted (upwards) and buoyancy opposed (downwards) flows in conducting and insulating ducts for a range of Hartmann numbers (Ha) up to 100, Reynolds numbers (Re) from 10 3 to 10 4 and Grashof (Gr) numbers from 10 7 to 10 8 . While increasing Gr or decreasing Re increases buoyancy effects, increasing Ha was shown to increase maximum temperature through turbulence reduction. The extent to which the MHD mixed convection flows are quasi-2D is analyzed and buoyant effects, in competition with electromagnetic forces, are shown to bring about 3D flow features not seen in purely MHD flows. Volumetric nuclear heating with steep gradients is applied to the vertical MHD flows for comparison to flows with surface heating only. Finally, surface heating generates stronger buoyancy effects than volumetric heating of the same total power; however, many of the same phenomena occur. Therefore, surface heating, the only option for lab experiments, can provide indication of the effects of volumetric heating in MHD flows.

42 ENGINEERING↗