Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DETECTOR PHYSICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Event-by-event direction reconstruction of solar neutrinos in a high light-yield liquid scintillator

The direction of individual B 8 solar neutrinos has been reconstructed using the SNO + liquid scintillator detector. Prompt, directional Cherenkov light was separated from the slower, isotropic scintillation light using time information, and a maximum likelihood method was used to reconstruct the direction of individual scattered electrons. A clear directional signal was observed, correlated with the solar angle. The observation was aided by a period of low primary fluor concentration that resulted in a slower scintillator decay time. This is the first time that event-by-event direction reconstruction in high light-yield liquid scintillator has been demonstrated in a large-scale detector. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New Radiation Tolerant LGAD for High Energy Physics

Low Gain Avalanche Detectors (LGADS) have recently been studied for applications in high energy physics. However, radiation hardness remains a problem. Here, we propose new LGAD process flow that allows for the creation of a very steep born profile in the multiapplication region, reducing the fractional acceptor removal and resulting performance degradation.

47 OTHER INSTRUMENTATION↗

Pixel detectors in 3D technologies for high energy physics

This paper reports on the current status of the development of International Linear Collider vertex detector pixel readout chips based on multi-tier vertically integrated electronics. Initial testing results of the VIP2a prototype are presented. The chip is the second embodiment of the prototype data-pushed readout concept developed at Fermilab. The device was fabricated in the MIT-LL 0.15 {micro}m fully depleted SOI process. The prototype is a three-tier design, featuring 30 x 30 {micro}m{sup 2} pixels, laid out in an array of 48 x 48 pixels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Toolkit to Study Sensitivity of the Geant4 Predictions to the Variations of the Physics Model Parameters

Geant4 is the leading detector simulation toolkit used in high energy physics to design detectors and to optimize calibration and reconstruction software. It employs a set of carefully validated physics models to simulate interactions of particles with matter across a wide range of interaction energies. These models, especially the hadronic ones, rely largely on directly measured cross-sections and phenomenological predictions with physically motivated parameters estimated by theoretical calculation or measurement. Because these models are tuned to cover a very wide range of possible simulation tasks, they may not always be optimized for a given process or a given material. This raises several critical questions, e.g. how sensitive Geant4 predictions are to the variations of the model parameters, or what uncertainties are associated with a particular tune of a Geant4 physics model, or a group of models, or how to consistently derive guidance for Geant4 model development and improvement from a wide range of available experimental data. We have designed and implemented a comprehensive, modular, user-friendly software toolkit to study and address such questions. It allows one to easily modify parameters of one or several Geant4 physics models involved in the simulation, and to perform collective analysis of multiple variants of the resulting physics observables of interest and comparison against a variety of corresponding experimental data. Based on modern event-processing infrastructure software, the toolkit offers a variety of attractive features, e.g. flexible run-time configurable workflow, comprehensive bookkeeping, easy to expand collection of analytical components. Design, implementation technology, and key functionalities of the toolkit are presented and illustrated with results obtained with Geant4 key hadronic models.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Accessing new physics with an undoped, cryogenic CsI CEvNS detector for COHERENT at the SNS

We consider the potential for a 10 kg undoped cryogenic CsI detector operating at the Spallation Neutron Source to measure coherent elastic neutrino-nucleus scattering and its sensitivity to discover new physics beyond the standard model (BSM). Through a combination of increased event rate, lower threshold, and good timing resolution, such a detector would significantly improve on past measurements. We considered tests of several BSM scenarios such as neutrino nonstandard interactions and accelerator-produced dark matter. This detector’s performance was also studied for relevant questions in nuclear physics and neutrino astronomy, namely the weak charge distribution of Cs and I nuclei and detection of neutrinos from a core-collapse supernova. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optimizing Geant4 Hadronic Models

Geant4, the leading detector simulation toolkit used in high energy physics, employs a set of physics models to simulate interactions of particles with matter across a wide range of energies. These models, especially the hadronic ones, rely largely on directly measured cross-sections and inclusive characteristics, and use physically motivated parameters. However, they generally aim to cover a broad range of possible simulation tasks and may not always be optimized for a particular process or a given material. The Geant4 collaboration recently made many parameters of the models accessible via a configuration interface. This opens a possibility to fit simulated distributions to the thin target experimental datasets and extract optimal values of the model parameters and the associated uncertainties. Such efforts are currently undertaken by the Geant4 collaboration with the goal of offering alternative sets of model parameters, also known as "tunes", for certain applications. The effort should subsequently lead to more accurate estimates of the systematic errors in physics measurements given the detector simulation role in performing the physics measurements. Results of the study are presented to illustrate how Geant4 model parameters can be optimized through applying fitting techniques, to improve the agreement between the Geant4 and the experimental data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Belle II imaging Time-of-Propagation (iTOP) Detector

High precision flavor physics measurements are an essential complement to the direct searches for new physics at the LHC. Such measurements will be performed using the upgraded Belle II detector that will take data at the SuperKEKB accelerator. With 40x the luminosity of KEKB, the detector systems must operate eciently at much higher rates than the original Belle detector. A central element of the upgrade is the barrel particle identication system. Belle II has built and installed an imaging-Time-of-Propagation (iTOP) detector. The iTOP uses quartz optics as Cerenkov radiators. The photons are transported down the quart bars via total internal reection with a spherical mirror at the forwardend to reflect photons to the backward end where they are imaged onto an array of segmented Micro-Channel Plate Photo-Multiplier Tubes. The system is readout using gigsample per second waveform sampling Application-Specific Integrated Circuits that provide precise photon timing. The combined timing and spatial distribution of the photons for each event are used to determine particle species. This paper provides an overview of the iTOP system.

Fast, James E.↗

Underground Physics at Berkeley: SNO, SNO+ and Detector R&D

Final technical report on the work carried out under this grant. The group plays a leadership role in both detector operations and production of science results from SNO+. The previous period has seen over 20 papers produced in journals such as Phys. Rev. C, Phys. Rev. D, and Eur. Phys. Jour. C. Results include new science from the Sudbury Neutrino Observatory, scientific results from the water phase of SNO+, and small-scale R&D work. The group has played a leadership role in each physics result from SNO and SNO+ during this period, including new solar neutrino results, leading limits on certain moves of invisible nucleon decay, limits on the neutrino lifetime and Lorentz violating effects, and studies of neutrons produced by cosmogenic muon and atmospheric neutrino interactions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Deep Underground Neutrino Experiment (DUNE), Far Detector Technical Design Report, Volume II: DUNE Physics

The preponderance of matter over antimatter in the early universe, the dynamics of the supernovae that produced the heavy elements necessary for life, and whether protons eventually decay -- these mysteries at the forefront of particle physics and astrophysics are key to understanding the early evolution of our universe, its current state, and its eventual fate. DUNE is an international world-class experiment dedicated to addressing these questions as it searches for leptonic charge-parity symmetry violation, stands ready to capture supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the standard model. The DUNE far detector technical design report (TDR) describes the DUNE physics program and the technical designs of the single- and dual-phase DUNE liquid argon TPC far detector modules. Volume II of this TDR, DUNE Physics, describes the array of identified scientific opportunities and key goals. Crucially, we also report our best current understanding of the capability of DUNE to realize these goals, along with the detailed arguments and investigations on which this understanding is based. This TDR volume documents the scientific basis underlying the conception and design of the LBNF/DUNE experimental configurations. As a result, the description of DUNE's experimental capabilities constitutes the bulk of the document. Key linkages between requirements for successful execution of the physics program and primary specifications of the experimental configurations are drawn and summarized. This document also serves a wider purpose as a statement on the scientific potential of DUNE as a central component within a global program of frontier theoretical and experimental particle physics research. Thus, the presentation also aims to serve as a resource for the particle physics community at large.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Science Requirements and Detector Concepts for the Electron-Ion Collider: EIC Yellow Report

Here, this report describes the physics case, the resulting detector requirements, and the evolving detector concepts for the experimental program at the Electron-Ion Collider (EIC). The EIC will be a powerful new high-luminosity facility in the United States with the capability to collide high-energy electron beams with high-energy proton and ion beams, providing access to those regions in the nucleon and nuclei where their structure is dominated by gluons. Moreover, polarized beams in the EIC will give unprecedented access to the spatial and spin structure of the proton, neutron, and light ions. The studies leading to this document were commissioned and organized by the EIC User Group with the objective of advancing the state and detail of the physics program and developing detector concepts that meet the emerging requirements in preparation for the realization of the EIC. The effort aims to provide the basis for further development of concepts for experimental equipment best suited for the science needs, including the importance of two complementary detectors and interaction regions. This report consists of three volumes. Volume I is an executive summary of our findings and developed concepts. In Volume II we describe studies of a wide range of physics measurements and the emerging requirements on detector acceptance and performance. Volume III discusses general-purpose detector concepts and the underlying technologies to meet the physics requirements. These considerations will form the basis for a world-class experimental program that aims to increase our understanding of the fundamental structure of all visible matter.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High Energy Physics Research: Experimental & Theoretical (Final Report)

The research at the energy frontier was to explore high energy and luminosity collisions at the LHC using the ATLAS and CMS detectors to lead physics analyses in characterization of the Higgs Boson, to search for its potential partners, to lead searches for Dark Matter and to make extensive studies of Electroweak phenomena. The objectives are also to operate and upgrade the ATLAS and CMS detectors and their computing to optimize their physics performance in the present data taking and to enable the full exploitation of planned High Luminosity LHC. The research for the theory frontier was to analyze and interpret the new data from the experimental frontiers: energy, cosmic and intensity (Phenomenology), to investigate new theories of high energy physics extending the standard model by including gravity within consistent frameworks such as string theory, and examine their phenomenological and cosmological implications (String Theory and Theoretical Cosmology.)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Status and Prospects of SBND

The Short-Baseline Near Detector (SBND) is one of the neutrino detectors positioned along the the Booster Neutrino Beam (BNB) at Fermilab. It is the near detector in the Short-Baseline Neutrino (SBN) Program, as well as having a wide-ranging independent physics program. The detector began taking neutrino data in the summer of 2024 and has already collected over 1 million neutrino events. Thanks to its unique combination of measurement resolution and statistics, SBND will soon carry out a rich program of neutrino interaction measurements and novel searches for physics beyond the Standard Model (BSM). As the SBN near detector, it will enable the full potential of the SBN sterile neutrino program by performing a precise characterisation of the unoscillated event rate and constraining BNB flux and neutrino-argon cross-section systematic uncertainties. In this talk, the physics reach, current status, and future prospects of SBND are discussed.

Paton, Josephine [Fermilab]↗

Measurement Of Gas Electron Multiplier (GEM) Detector Characteristics

The High Energy Physics group of the University of Texas at Arlington has been developing gas electron multiplier detectors to use them as sensitive gap detectors in digital hadron calorimeters for the International Linear Collider, a future high energy particle accelerator. For this purpose, we constructed numerous GEM detectors that employ double GEM layers. In this study, two kinds of prototype GEM detectors were tested; one with 28x28 cm{sup 2} active area double GEM structure with a 3 mm drift gap, a 1 mm transfer gap and a 1 mm induction gap and the other with two 3x3 cm{sup 2} GEM foils in the amplifier stage with a 5 mm drift gap, a 2 mm transfer gap and a 1 mm induction gap. The detectors' characteristics from exposure to high-energy charged particles and other radiations were measured using cosmic rays and {sup 55}Fe radioactive source. From the {sup 55}Fe tests, we observed two well separated characteristic X-ray emission peaks and confirmed the detectors' functionality. We also measured chamber gains to be over 6000 at a high voltage of 395 V across each GEM electrode. The responses to cosmic rays show the spectra that fit well to Landau distributions as expected from minimum ionizing particles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The large-area hybrid-optics CLAS12 RICH: Assembling, commissioning and first data-taking

Here, the first module of a Ring Imaging Cherenkov detector has been recently installed on the CLAS12 spectrometer at the Jefferson Lab (JLab) to provide the experiment with kaon identification in the momentum range between 3 and 8 GeV/c. The detector adopts a hybrid optics solution with aerogel radiator, light planar and spherical mirrors and highly-segmented photon detectors. We report here on the assembly and installation of the RICH and we show the first preliminary results obtained during the commissioning of the detector and the first physics data taking.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress in end-to-end optimization of fundamental physics experimental apparata with differentiable programming

In this article we examine recent developments in the research area concerning the creation of end-to-end models for the complete optimization of measuring instruments. The models we consider rely on differentiable programming methods and on the specification of a software pipeline including all factors impacting performance — from the data-generating processes to their reconstruction and the inference on the parameters of interest — along with the careful specification of a utility function well aligned with the end goals of the experiment. Building on previous studies originated within the MODE Collaboration, we focus specifically on applications involving instruments for particle physics experimentation, as well as industrial and medical applications that share the detection of radiation as their data-generating mechanism. This report illustrates the most recent advancements in the area, and outlines, for each of the discussed applications as well as for automatic differentiation itself, ongoing and future work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A perspective on the device physics of lead halide perovskite semiconducting detector for gamma and x-ray sensing

Metal-halide perovskites are emerging materials for radiation sensing featuring high absorption cross section, high charge mobility, and long carrier lifetime enabling superior detection efficiencies even at room temperature. Perovskite detector technologies are more complex involving different detecting modes and device architectures. Here, to elucidate the working principles, we provide a Perspective on the device structures and the operational principles of halide perovskite direct conversion detectors for radiation sensing. We will first discuss different detection modes and introduce the commonly used device architectures and their working principles. Based on our work and pioneer developments in the field, we will next compare the performances of the reported detectors. Additionally, we will summarize the single crystal detectors and polycrystalline thin film devices and discuss their advantages and disadvantages for different applications. Finally, we provide a future Perspective on the critical problems that must be addressed to commercialize this technology.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Determination of electron beam polarization using electron detector in Compton polarimeter with less than 1% statistical and systematic uncertainty

The Q-weak experiment aims to measure the weak charge of proton with a precision of 4.2%. The proposed precision on weak charge required a 2.5% measurement of the parity violating asymmetry in elastic electron - proton scattering. Polarimetry was the largest experimental contribution to this uncertainty and a new Compton polarimeter was installed in Hall C at Jefferson Lab to make the goal achievable. In this polarimeter the electron beam collides with green laser light in a low gain Fabry-Perot Cavity; the scattered electrons are detected in 4 planes of a novel diamond micro strip detector while the back scattered photons are detected in lead tungstate crystals. This diamond micro-strip detector is the first such device to be used as a tracking detector in a nuclear and particle physics experiment. The diamond detectors are read out using custom built electronic modules that include a preamplifier, a pulse shaping amplifier and a discriminator for each detector micro-strip. We use field programmable gate array based general purpose logic modules for event selection and histogramming. Extensive Monte Carlo simulations and data acquisition simulations were performed to estimate the systematic uncertainties. Additionally, the Moller and Compton polarimeters were cross calibrated at low electron beam currents using a series of interleaved measurements. In this dissertation, we describe all the subsystems of the Compton polarimeter with emphasis on the electron detector. We focus on the FPGA based data acquisition system built by the author and the data analysis methods implemented by the author. The simulations of the data acquisition and the polarimeter that helped rigorously establish the systematic uncertainties of the polarimeter are also elaborated, resulting in the first sub 1% measurement of low energy (?1 GeV) electron beam polarization with a Compton electron detector. We have demonstrated that diamond based micro-strip detectors can be used for tracking in a high radiation environment and it has enabled us to achieve the desired precision in the measurement of the electron beam polarization which in turn has allowed the most precise determination of the weak charge of the proton.

43 PARTICLE ACCELERATORS↗