A Battery Charger and State of Charge Indicator

A battery charger which has a full wave rectifier in series with a transformer isolated 20 kHz dc-dc converter with high frequency switches, which are programmed to actively shape the input dc line current to be a mirror image of the ac line voltage is discussed. The power circuit operates at 2 kW peak and 1 kW average power. The BC/SCI has two major subsystems: (1) the battery charger power electronics with its controls; and (2) a microcomputer subsystem which is used to acquire battery terminal data and exercise the state of charge software programs. The state of charge definition employed is the energy remaining in the battery when extracted at a 10 kW rate divided by the energy capacity of a fully charged new battery. The battery charger circuit is an isolated boost converter operating at an internal frequency of 20 kHz. The switches selected for the battery charger are the single most important item in determining its efficiency. The combination of voltage and current requirements dictate the use of high power NPN Darlington switching transistors. The power circuit topology is a three switch design which utilizes a power FET on the center tap of the isolation transformer and the power Darlingtons on each of the two ends. An analog control system is employed to accomplish active input current waveshaping as well as the necessary regulation.

Latos, T. S.↗

Switching Voltage Regulator

Both pulsed and continuous outputs available. Switching power-supply circuit converts input power from two 9-V batteries in series to output of 5 Vdc regulated within 1.5 percent, either at continuous current of 5 mA or at current of 500 mA in 0.5-s pulses at 1-min intervals. Power supply is buck converter. Principle of operation inductive and capacitive filtering of controlled pulses of battery voltage.

Mclyman, W. T.↗

Multivariable control of the Space Shuttle remote manipulator system using H2 and H(infinity) optimization

Three linear controllers are desiged to regulate the end effector of the Space Shuttle Remote Manipulator System (SRMS) operating in Position Hold Mode. In this mode of operation, jet firings of the Orbiter can be treated as disturbances while the controller tries to keep the end effector stationary in an orbiter-fixed reference frame. The three design techniques used include: the Linear Quadratic Regulator (LQR), H2 optimization, and H-infinity optimization. The nonlinear SRMS is linearized by modelling the effects of the significant nonlinearities as uncertain parameters. Each regulator design is evaluated for robust stability in light of the parametric uncertanties using both the small gain theorem with an H-infinity norm and the less conservative micro-analysis test. All three regulator designs offer significant improvement over the current system on the nominal plant. Unfortunately, even after dropping performance requirements and designing exclusively for robust stability, robust stability cannot be achieved. The SRMS suffers from lightly damped poles with real parametric uncertainties. Such a system renders the micro-analysis test, which allows for complex peturbations, too conservative.

Prakash, OM, II↗

Multivariable control of the Space Shuttle Remote Manipulator System

Linear controllers are designed to regulate the end effector of the Space Shuttle Remote Manipulator System (SRMS) operating in position hold mode. Design techniques used include H2 and H-infinity optimization. The nonlinear SRMS is linearized by modeling the effects of the significant nonlinearities as uncertain parameters. Each regulator design is evaluated for robust stability using both the small gain theorem with an H-infinity norm and the less conservative mu-analysis test. Regulator designs offer significant improvement over the current system for the nominal plant. Unfortunately, the SRMS model suffers from lightly damped poles with real parametric uncertainty. Under such conditions, the mu-analysis test, which allows for complex perturbations, cannot guarantee robust stability.

Adams, Neil J.↗

Control, Fault Management, and Grid Support Functionality of an MV AC-DC Solid State Transformer based EV Extreme Fast Charging Station

Electric vehicles (EVs) have become increasingly popular in recent times while revolutionizing the consumer and commercial transportation market. The development of charging infrastructure has become one of the priorities for increasing the adoption of EVs. Extreme fast charging (XFC) technology can reduce the so-called ’range anxiety’ of consumers as they significantly reduce the charging time. With the advent of wide band-gap (WBG) power devices and improvement in power electronic converters, medium voltage (MV) solid state transformer (SST) based XFC system has the potential to replace the traditional XFC stations because of the lower footprint, ease of installation, enhanced control feature, and better system efficiency. The control system design is one of the critical aspects of the SST development process. Careful consideration and detailed analysis are required to find out suitable control method for the SST based on its topology among different centralized and decentralized control architectures. Also, the control parameters selection and potential improvement to the transient response of the controller ought to be investigated. Another major concern of the SST is different types of internal fault which reduces the overall reliability of the XFC system. As a result, designing a robust protection system is essential. Among different fault modes, open circuit switch faults have received significant attention as an active research area because of their likelihood and severe effects on converters. Therefore, the power stages used in the XFC system require functional and accurate open circuit switch fault management methods. An equally significant aspect of this SST based XFC is its compatibility in a microgrid where there is no synchronous generator present. When the grid is not available, the XFC SSTs can provide grid forming capability and continue supplying the critical loads in islanded mode. The transition between grid connected and islanded mode, especially the grid resynchronization process has to be carefully performed for the safety of the microgrid components. The challenges posed by the aforementioned issues have inspired the work done in this dissertation. Here, a 13.2 kV, 1 MVA, AC/DC SST for the XFC system is examined and a comparative analysis is conducted to select the control architecture based on feasibility of implementation and performance. A detailed control parameter design process is demonstrated considering the sensor dynamics and delay. The selected decentralized control method is augmented by introducing a novel sensor-less load current feedforward method to provide better voltage regulation at the DC bus during a change of load. Next, in the fault management section, a hierarchical failure mode effect analysis (FMEA) is proposed to enable a systematic design of the internal fault protection of the XFC SST as there are limited examples in the literature regarding the analysis of the safety and design of the protection of a power electronic converter system. Novel open circuit switch fault management methods for the converters in the system are presented. Finally, XFC SST based MV microgrid operations in grid connected mode and islanded mode are explored. A secondary control method for grid resynchronization is presented and a design process of control parameters is shown to ensure the stability of the secondary voltage and frequency regulation.

30 DIRECT ENERGY CONVERSION↗

A Systematic Approach to Developing Paths Towards Airborne Vehicle Autonomy

Advanced Air Mobility (AAM) demands greater levels of aircraft autonomy than are currently implemented today. To enable this requirement, novel aircraft functionalities and technologies as well as supporting airworthiness and operational regulations are required. A structured method to derive a comprehensive list of aircraft level decision-making functions is defined and applied. The resulting function set is programmed into an ontology, and enables autonomous decision-making through the application of a defined decision-making process. Paths to implementing the functions are generated by applying a structured four step method. By surveying current technologies, airspace, procedures and regulations, the paths generation method defines incremental paths to autonomy that the current regulatory environment can support. Opportunities to implement novel technologies and functions are identified, and regulatory mechanisms supporting their implementation are underscored. The analysis provides the tools to further define aircraft functions and paths to their implementation, while demonstrating that for particular use cases, aircraft autonomy is attainable in the medium-term.

Paul Vajda↗

Electrochemical Synthesis of Zeolite Coatings with Controlled Crystal Polymorphism and Self-Regulating Growth

Zeolite coatings are studied as molecular sieves for membrane separation, membrane reactors, and chemical sensor applications. They are also studied as anticorrosive films for metals and alloys, antimicrobial and hydrophobic films for heating, ventilation, and air conditioning, and dielectrics for semiconductor applications. Zeolite coatings are synthesized by hydrothermal, ionothermal, and dry-gel conversion approaches, which require high process temperatures and lengthy times (ranging from hours to days). Here, we report the first zeolite coatings synthesized via electrochemical deposition on a cathodic electrode, with controlled crystal polymorphism achieved within subhourly duration. We demonstrate this approach by developing sodium zeolite (e.g., sodalite (SOD), NaA (LTA), and Linde Type N (LTN)) coatings on a titanium electrode and extending the synthesis method to porous stainless steel. The coating morphology and crystallinity depend on the temperature, time, and applied current. The coating thickness is independent of the applied current, showing the presence of a self-regulating mechanism to ensure a uniform coating thickness across the metal surface. The electrochemical zeolite growth mechanism was elucidated with high-resolution transmission electron microscopy, and applications of the resultant zeolite coatings for oil/water separation and ethanol/water pervaporation were exploited. Electrochemical synthesis represents a novel, simple, fast, and environmentally friendly approach to preparing zeolite coatings. It can potentially be generalized for developing zeolite materials with diverse framework structures, morphologies, and orientations for substrates with complicated geometries.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Thermal Ion Dynamics Experiment and Plasma Source Instrument

The Thermal Ion Dynamics Experiment (TIDE) and the Plasma Source Instrument (PSI) have been developed in response to the requirements of the ISTP Program for three-dimensional (3D) plasma composition measurements capable of tracking the circulation of low-energy (0-500 eV) plasma through the polar magnetosphere. This plasma is composed of penetrating magnetosheath and escaping ionospheric components. It is in part lost to the downstream solar wind and in part recirculated within the magnetosphere, participating in the formation of the diamagnetic hot plasma sheet and ring current plasma populations. Significant obstacles which have previously made this task impossible include the low density and energy of the outflowing ionospheric plasma plume and the positive spacecraft floating potentials which exclude the lowest-energy plasma from detection on ordinary spacecraft. Based on a unique combination of focusing electrostatic ion optics and time of flight detection and mass analysis, TIDE provides the sensitivity (seven apertures of about 1 cm squared effective area each) and angular resolution (6 x 18 degrees) required for this purpose. PSI produces a low energy plasma locally at the POLAR spacecraft that provides the ion current required to balance the photoelectron current, along with a low temperature electron population, regulating the spacecraft potential slightly positive relative to the space plasma. TIDE/PSI will: (a) measure the density and flow fields of the solar and terrestrial plasmas within the high polar cap and magnetospheric lobes; (b) quantify the extent to which ionospheric and solar ions are recirculated within the distant magnetotail neutral sheet or lost to the distant tail and solar wind; (c) investigate the mass-dependent degree energization of these plasmas by measuring their thermodynamic properties; (d) investigate the relative roles of ionosphere and solar wind as sources of plasma to the plasma sheet and ring current.

Moore, T. E.↗

Resistojet control and power for high frequency ac buses

Resistojets are operational on many geosynchronous communication satellites which all use dc power buses. Multipropellant resistojets were selected for the Initial Operating Capability (IOC) Space Station which will supply 208 V, 20 kHz power. This paper discusses resistojet heater temperature controllers and passive power regulation methods for ac power systems. A simple passive power regulation method suitable for use with regulated sinusoidal or square wave power was designed and tested using the Space Station multipropellant resistojet. The breadboard delivered 20 kHz power to the resistojet heater. Cold start surge current limiting, a power efficiency of 95 percent, and power regulation of better than 2 percent were demonstrated with a two component, 500 W breadboard power controller having a mass of 0.6 kg.

Gruber, Robert P.↗

Resistojet control and power for high frequency ac buses

Resistojets are operational on many geosynchronous communication satellites which all use dc power buses. Multipropellant resistojets were selected for the Initial Operating Capability (IOC) Space Station which will supply 208 V, 20 kHz power. This paper discusses resistojet heater temperature controllers and passive power regulation methods for ac power systems. A simple passive power regulation method suitable for use with regulated sinusoidal or square wave power was designed and tested using the Space Station multipropellant resistojet. The breadboard delivered 20 kHz power to the resistojet heater. Cold start surge current limiting, a power efficiency of 95 percent, and power regulation of better than 2 percent were demonstrated with a two component, 500 W breadboard power controller having a mass of 0.6 kg.

Gruber, Robert P.↗

Underwater Noise Measurements around a Tidal Turbine in a Busy Port Setting

Acoustic emissions from current energy converters remain an environmental concern for regulators because of their potential effects on marine life and uncertainties about their effects stemming from a lack of sufficient observational data. Several recent opportunities to characterize tidal turbine sound emissions have begun to fill knowledge gaps and provide a context for future device deployments. In July 2021, a commercial-off-the-shelf hydrophone was deployed in a free-drifting configuration to measure underwater acoustic emissions and characterize a 25 kW-rated tidal turbine at the University of New Hampshire’s Living Bridge Project in Portsmouth, New Hampshire. Sampling methods and analysis were performed in alignment with the recently published IEC 62600-40 Technical Specification for acoustic characterization of marine energy converters. Results from this study indicate acoustic emissions from the turbine were below ambient sound levels and therefore did not have a significant impact on the underwater noise levels of the project site. As a component of Pacific Northwest National Laboratory’s Triton Field Trials (TFiT) described in this Special Issue, this effort provides a valuable use case for the IEC 62600-40 Technical Specification framework and further recommendations for cost-effective technologies and methods for measuring underwater noise at future current energy converter project sites.

tidal turbine↗

Improved dc voltage regulator

Simplified solid-state circuit provides a closely regulated dc voltage from an unregulated dc source. It eliminates the undesirable loading effect of the emitter-base current of a transistor used in an error-sensing circuit of a regulated dc power supply.

Barnes, H. F.↗

Physiological Self-Regulation and Adaptive Automation

Adaptive automation has been proposed as a solution to current problems of human-automation interaction. Past research has shown the potential of this advanced form of automation to enhance pilot engagement and lower cognitive workload. However, there have been concerns voiced regarding issues, such as automation surprises, associated with the use of adaptive automation. This study examined the use of psychophysiological self-regulation training with adaptive automation that may help pilots deal with these problems through the enhancement of cognitive resource management skills. Eighteen participants were assigned to 3 groups (self-regulation training, false feedback, and control) and performed resource management, monitoring, and tracking tasks from the Multiple Attribute Task Battery. The tracking task was cycled between 3 levels of task difficulty (automatic, adaptive aiding, manual) on the basis of the electroencephalogram-derived engagement index. The other two tasks remained in automatic mode that had a single automation failure. Those participants who had received self-regulation training performed significantly better and reported lower National Aeronautics and Space Administration Task Load Index scores than participants in the false feedback and control groups. The theoretical and practical implications of these results for adaptive automation are discussed.

Prinzell, Lawrence J.↗

Apple Bitter Rot: Biology, Ecology, Omics, Virulence Factors, and Management of Causal Colletotrichum Species

ABSTRACT Apple bitter rot is caused by various Colletotrichum spp. that threaten apple production globally resulting in millions of dollars in damage annually. The fungus causes a decline in fruit quality and yield, eventually rotting the fruit and rendering it inedible. The pathogen is difficult to keep out of orchards because of its broad host range and transmissibility by rain splash and insects. Once the disease manifests, pathogen identification is difficult due to evolving taxonomy and similar morphology between species. Current management strategies are threatened by an increase in fungicide resistance and regulations on many multisite fungicides, leading to a pressing need for new management options for control. This review aims to summarise the most current knowledge regarding the biology, virulence factors, ecology, omics and emerging management strategies for Colletotrichum species that cause apple bitter rot. Taxonomy Colletotrichum species—Domain Eukaryota, Kingdom Fungi, Phylum Ascomycota, Class Sordariomycetes, Order Glomerellales, Family Glomerellaceae, Genus Colletotrichum . Biology Hemibiotrophic pathogen with a wide host range that establishes a biotrophic interaction where it penetrates host plants using appressoria followed by a switch to necrotrophy causing rot symptoms. Toxins Cercosporin, colletotrichins, colletotric acid, ferricrocin. Host Range The host range varies by species but largely occurs on dicotyledonous plants and is less prevalent on monocots as well as gymnosperms, ferns, mosses and animals (e.g., insects). Disease Symptoms Symptoms often manifest as flat to sunken necrotic areas on fruit. Lesions on leaves and fruit can have concentric rings with abundant pathogen sporulation. Disease Control Colletotrichum spp. are primarily managed by single‐site quinone outside inhibitor (Qol), methyl benzimidazole carbamate (MBC), demethylation inhibitor (DMI) fungicides, and multisite dithiocarbamate and phthalimide fungicides. Susceptibility may vary with species, strain specificity, or geographic region. Other management options include clean stock production, cultural practices, resistance breeding, and biological control through the introduction of protective or competing microorganisms.

Boeckman, Nathanial J. [Plant Pathology Laboratory↗

Characteristics of an Introduced Walleye Population with Implications for Suppression

Abstract The management of introduced fishes, including Walleye Sander vitreus, whether for control or enhancement, requires understanding of population dynamics at the invasion front. Walleye recently established in the Pend Oreille basin, Idaho, threaten the existing salmonid-based fish community and associated recreational fishery. Therefore, the objectives of this study were to describe population growth and associated life history characteristics. Walleye were sampled in October of 2011, 2014, and 2017 using a standardized gill netting survey protocol to describe trends in relative abundance and evaluate population dynamics. Relative abundance increased exponentially from 1.4 to 4.3 fish/net over the 6-year monitoring period. This population was characterized by fast somatic growth, robust body condition, and early age at maturity at or near the biological maxima for Walleye. Among the survey years, mean length at age 2 varied for female (359–441 mm) and male (358–426 mm) Walleye and relative weight varied from 91 to 98. The sampled Walleye matured at 1 to 4 years of age, and recruitment became more consistent as abundance increased. These density-dependent metrics suggest that the Walleye population is still at low density relative to carrying capacity. The information that was gained from this study was used to better understand potential risks and guide management decisions related to experimental population suppression that is now underway. Suppression under these conditions must overcome the recruitment capabilities of the population. We conclude that natural mortality is likely regulated by density-dependent processes. Therefore, at current (low) density, fishing mortality may be entirely additive and compensation is unlikely to further complicate management.

Ryan, Robert G.↗

Analysis of High Frequency AC Link Isolated Three Port Resonant Converter for UAV Applications

A high frequency AC link isolated three port semi-bridgeless resonant converter is analyzed for unmanned aerial vehicle (UAV) applications in this study. The proposed topology is established by replacing rectifier lover diodes with synchronous switches. A phase shifted pulse width modulation (PS-PWM) technique adjusts bi-directional power flow between ports. Proposed control technique provides high efficiency by reducing switching losses with zero voltage switching (ZVS) and zero current switching (ZCS) in a wide power range regulation. Compared to integrated PWM converters in a bi-directional mode, the proposed topology reduces the number of converter stages and allows centralized control at high operating frequency. Theoretical and experimental results demonstrate the feasibility and effectiveness of the proposed converter at a full power of 500 W in laboratory conditions.

Asa, Erdem↗

Provably-Stable Overload Ride-Through Control for Grid-Forming Inverters Using System-Wide Lyapunov Function Analysis

A key challenge associated with a grid-forming (GFM) inverter based resource (IBR) is its behavior during severe grid disturbances: since a GFM inverter regulates voltage in the fast timescale instead of current or power, it may experience a transient overload of current, power and/or energy during a severe grid disturbance. While many promising control strategies for overload ride-through have been proposed over the past two decades, transient stability of the system during and after the transition to an overload ride-through control mode remains difficult to guarantee. In this work, a novel overload ride-through control strategy is proposed for a system of grid-forming inverters that takes both self-protection and system-wide transient stability into account. A proposed system-level supervisory control uses slow communication to pre-emptively assign a set of local ride through control parameters to individual GFM IBR, including a current-limiting virtual reactance, that guarantees that synchronism is still preserved for any set of anticipated grid disturbances. At the core of the supervisory control lies a Lyapunov-function-based routine capable of establishing a strong, albeit conservative, transient stability guarantee for the system. Here, the proposed overload ride-through control strategy is validated via numerical integration of a reduced-order model, as well as through detailed electromagnetic transient (EMT) simulation.

30 DIRECT ENERGY CONVERSION↗

Towards a Deeper Understanding of Automation Transparency in the Operation of Nuclear Plants

Automation technologies have the potential to reduce operations and maintenance costs, ensure reliable power generation and safety, and thereby contribute to extending the lifespan of nuclear power plants. To fulfill this aspiration, automation behaviors have to be understandable and predictable to human operators and traceable for license holders and regulators in the event of automation failures. The current report investigates how automation transparency as a systems design principle can keep operators sufficiently informed about the inner workings of automation or make fail-safe automation run invisibly in the background to free up operator capacity.

99 GENERAL AND MISCELLANEOUS↗