In situ cryogenic characterization of proton damage in thick p-channel skipper CCDs

Skipper charge-coupled devices (CCDs) are an offshoot of standard silicon pixel detectors and are capable of performing repeated non-destructive charge measurements, enabling deeply sub-electron readout noise. This capability has opened the door to single-photon counting from the near-infrared ($\sim$1.1 $μ$m) to the soft X-ray (several keV), making these devices strong candidates for future astronomical instruments operating in the photon-starved limit. Furthermore, the p-channel architecture used to fabricate Skipper CCDs on n-type silicon has been demonstrated to have an increased hardness to the intense radiation environment of space. Building upon previous irradiation campaigns on room-temperature sensors, here we describe the first radiation-hardness tests of p-channel skipper CCDs at their cryogenic operating temperatures. We assess the performance of the floating-gate output stage and global CCD parameters (charge transfer inefficiency, dark current, hot pixels, and charge traps). We find that these devices maintain excellent performance after displacement damage doses equivalent to ${\sim}$10 years at the Earth/Sun L2 Lagrange point, demonstrating for the first time that these sensors remain radiation-hard in realistic deep-space thermal and radiation environments.

Roach, Brandon M. [Chicago U., KICP] (ORCID:000000↗

Design of a Cryogenic Assembly for Comparing Qubit Infrared Packaging Inefficiencies

It is well known that everything emits infrared (IR) light in the form of thermal radiation. IR radiation on superconducting qubits carries enough energy to cause decoherence and so-called “quasiparticle poisoning.” Therefore, proper IR shielding is needed to keep the qubit in a high-coherence state. However, trying to extract IR-specific information from a qubit is difficult, so a microwave kinetic inductance detector (MKID) can be used instead. We show that the IR shielding inefficiencies of MKID packages can only be compared with other packaging inefficiencies. We create a cryogenic assembly CAD design, consisting of magnetic shield cans, a copper mounting plate and mounts, and an MKID enclosure, which thermalizes the assembly to dilution refrigerator temperatures. Phase 1 of this design involves using a narrowband IR laser source to test the IR shielding of packaging at the laser’s wavelength. When the best IR shielding packaging is determined, the superconducting qubit can replace the MKID, allowing the qubit to avoid decoherence due to IR radiation and boost its performance and coherence lifetime.

Mailliard, Robert J. [Fermilab] (ORCID:00090000277↗

Effective thermal conductivity of insulation materials for cryogenic LH 2 storage tanks: A review

An accurate estimation of the effective thermal conductivity of various insulation materials is essential in the evaluation of heat leak and boil-off rate from liquid hydrogen storage tanks. In this work, we review the existing experimental data and various proposed correlations for predicting the effective conductivity of insulation systems consisting of powders, foams, fibrous materials, and multilayer systems. We also propose a first principles-based correlation that may be used to estimate the dependence of the effective conductivity as a function of temperature, interstitial gas composition, pressure, and structural properties of the material. We validate the proposed correlation using available experimental data for some common insulation materials. Further improvements and testing of the proposed correlation using laboratory scale data obtained using potential LH 2 tank insulation materials are also discussed.

08 HYDROGEN↗

An in situ ambient and cryogenic transmission electron microscopy study of the effects of temperature on dislocation behavior in CrCoNi-based high-entropy alloys with low stacking-fault energy

Temperature is known to affect deformation mechanisms in metallic alloys. As temperature decreases, the stacking-fault energy in many face-centered cubic (fcc) alloys decreases, resulting in a change of deformation mode from dislocation slip to deformation twinning. Such an impact of temperature can be more complex in compositionally heterogeneous microstructures that exhibit, for example, local concentration fluctuation such as that in multi-principal element alloys. In this work, we compare the dislocation behavior and mechanical properties of a fcc Cr 20 Mn 10 Fe 30 Co 30 Ni 10 high-entropy alloy at ambient and liquid-nitrogen temperatures. We find that a network of stacking faults is formed by uniformly extended dislocations at ambient temperatures with low stacking-fault energy, whereas at lower temperatures, uneven dissociation of dislocations becomes significant, which results in severe dislocation pile-ups together with their pronounced entanglement. Our findings indicate that as the stacking-fault energy decreases with decreasing temperature, the heterogeneity of the distribution of elements becomes more dominant in tuning the local variation of lattice resistance. As a result, the change in dislocation behavior at low temperatures strongly affects microstructural evolution and consequently leads to significantly more pronounced work hardening.

36 MATERIALS SCIENCE↗

High-Fidelity CFD Modeling of Cryogenic Hydrogen Isotope Extrusion for Fusion Reactor Pellet Fueling

This study investigates the extrusion processes of deuterium and protium using ANSYS-Polyflow. The geometries and computational fluid dynamics (CFD) settings closely replicate the experimental setups and data acquired from the extruder experiments at Oak Ridge National Laboratory (ORNL) for validation purposes. We explore the impacts of (1) slip versus non-slip boundary conditions and (2) the use of constant, temperature-, and shear rate–dependent viscosities, concluding that the implementation of non-slip wall boundary conditions combined with shear rate–dependent viscosity produced more accurate predictions. The simulations achieved excellent agreement with the experimental data, with relative differences of only 5% for deuterium, and 3% to 6% for protium. This is the first time that experimental extrusion data at ORNL have been accurately predicted through high-fidelity CFD modeling. In conclusion, the advancements offer valuable insights and a foundational modeling tool for optimizing pellet injectors for ITER and other future reactor-scale devices.

ANSYS-Polyflow↗

Near-Monochromatic Tuneable Cryogenic Niobium Electron Field Emitter

We report creating, manipulating, and detecting coherent electrons is at the heart of future quantum microscopy and spectroscopy technologies. Leveraging and specifically altering the quantum features of an electron beam source at low temperatures can enhance its emission properties. Here, we describe electron field emission from a monocrystalline, superconducting niobium nanotip at a temperature of 5.9 K. The emitted electron energy spectrum reveals an ultranarrow distribution down to 16 meV due to tunable resonant tunneling field emission via localized band states at a nanoprotrusion’s apex and a cutoff at the sharp low-temperature Fermi edge. This is an order of magnitude lower than for conventional field emission electron sources. The self-focusing geometry of the tip leads to emission in an angle of 3.7°, a reduced brightness of 3.8 × 10 8 A/(m 2 srV), and a stability of hours at 4.1 nA beam current and 69 meV energy width. This source will decrease the impact of lens aberration and enable new modes in low-energy electron microscopy, electron energy loss spectroscopy, and high-resolution vibrational spectroscopy.

36 MATERIALS SCIENCE↗

Unraveling the discontinuous plastic flow of a Co-Cr-Fe-Ni-Mo multiprincipal-element alloy at deep cryogenic temperatures

We report an analysis of the discontinuous plastic flow of a multiprincipal-element alloy, Co 17.5 Cr 12.5 Fe 55 Ni 10 Mo 5 (atomic percent, at. %), in the temperature range of 0.5–4.2 K showing serrated deformation curves. Using the analytical techniques, we studied the statistics of the stress drops associated with the unstable plastic flow. The analysis showed that the complexity and heterogeneity of a discontinuous plastic flow were reduced when the temperature was lowered. This behavior was associated with the effects of dynamic recovery and adiabatic heating on the dislocation-density evolution.

36 MATERIALS SCIENCE↗

Cryogenic optical beam steering for superconducting device calibration

We have developed a calibration system based on a micro-electromechanical systems (MEMS) mirror that is capable of delivering an optical beam over a wavelength range of 180 -- 2000 nm (0.62 -- 6.89 eV) in a sub-Kelvin environment. This portable, integrated system can steer the beam over a $\sim$3 cm $\times$ 3 cm area on the surface of any sensor with a precision of $\sim$100 $μ$m, enabling characterization of device response as a function of position. This fills a critical need in the landscape of calibration tools for sub-Kelvin devices, including those used for dark matter detection and quantum computing. These communities have a shared goal of understanding the impact of ionizing radiation on device performance, which can be pursued with our system. This paper describes the design of the first-generation calibration system and the results from successfully testing its performance at room temperature and 20 mK.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Atomic faulting induced exceptional cryogenic strain hardening in gradient cell–structured alloy

Coarse-grained materials are widely accepted to display the highest strain hardening and the best tensile ductility. We experimentally report an attractive strain hardening rate throughout the deformation stage at 77 kelvin in a stable single-phase alloy with gradient dislocation cells that even surpasses its coarse-grained counterparts. Contrary to conventional understanding, the exceptional strain hardening arises from a distinctive dynamic structural refinement mechanism facilitated by the emission and motion of massive multiorientational tiny stacking faults (planar defects), which are fundamentally distinct from the traditional linear dislocation–mediated deformation. In conclusion, the dominance of atomic-scale planar deformation faulting in plastic deformation introduces a different approach for strengthening and hardening metallic materials, offering promising properties and potential applications.

Gradient dislocation structure↗