Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Control Systems Security”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Smart Contract-Defined Secondary Control and Co-Simulation for Smart Solar Inverters using Blockchain Technology

This paper proposes a cooperative control approach using blockchain technology for solar inverters in a photovoltaic system. Moreover, a co-simulation method for smart inverters and a blockchain network is studied. The blockchain assisted-smart inverter (BASI) consists of a solar inverter and an internet of things device as a client node of a blockchain network, which can fully utilize emerging blockchain technologies such as distributed ledger, security functions, and smart contract. The control includes a primary-level droop control in a BASI and smart contract-defined secondary-level supervisory control in a secured blockchain network. The concept of the proposed smart contract-defined control approach is validated by simulation studies using the cyber-physical co-simulation testbed built-in MATLAB/Simulink in a PC interfacing with a Hyperledger-Fabric blockchain software implemented in a PC.

14 SOLAR ENERGY↗

Optoelectronic polymer memristors with dynamic control for power-efficient in-sensor edge computing

Abstract As the demand for edge platforms in artificial intelligence increases, including mobile devices and security applications, the surge in data influx into edge devices often triggers interference and suboptimal decision-making. There is a pressing need for solutions emphasizing low power consumption and cost-effectiveness. In-sensor computing systems employing memristors face challenges in optimizing energy efficiency and streamlining manufacturing due to the necessity for multiple physical processing components. Here, we introduce low-power organic optoelectronic memristors with synergistic optical and mV-level electrical tunable operation for a dynamic “control-on-demand” architecture. Integrating signal sensing, featuring, and processing within the same memristors enables the realization of each in-sensor analogue reservoir computing module, and minimizes circuit integration complexity. The system achieves 97.15% fingerprint recognition accuracy while maintaining a minimal reservoir size and ultra-low energy consumption. Furthermore, we leverage wafer-scale solution techniques and flexible substrates for optimal memristor fabrication. By centralizing core functionalities on the same in-sensor platform, we propose a resilient and adaptable framework for energy-efficient and economical edge computing.

Optics↗

Microreactor Security-by-Design Recommendations for Domestic and International Deployments

This report outlines methods vendors can use to incorporate security-by-design (SeBD) into their microreactor facility design to support and address security for both U.S. and international deployment. The team developed a hypothetical below-grade microreactor with a physical protection system (PPS) to protect the microreactor against acts of theft and sabotage and evaluated it against two adversary attack scenarios defined by a group of adversary subject matter experts (SMEs). The hypothetical microreactor facility consists of two distinct buildings. The first is the above-grade protected area (PA) entry control point (ECP) building, which houses security personnel responsible for conducting screenings and managing access to the PA. The second building is the reactor building, which features both an above-grade floor and a below-grade floor.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Towards generic memory forensic framework for programmable logic controllers

A Programmable Logic Controller (PLC) is a microprocessor-based controller that is used to automate physical processes in critical infrastructure and various other industries and manufacturing sectors. Initially, PLCs were completely isolated from the Internet, and cyber security was not incorporated at the time of development. The introduction of industry 4.0 and the evolution of ICS systems to communicate over public IP addresses from the Internet enhanced productivity and efficiency, but Internet connectivity exposed the systems and their vulnerabilities, which led to an increase in cyber attacks. When a system is sabotaged/compromised, security analysts need to get to the root cause of the attack as quickly as possible to recover the system. To do so, memory forensic analysis is critical to provide a unique insight into the run-time memory activities and extract a reliable source of evidence. In this paper, we analyze the memory structure of the Schneider Electric Modicon M221 PLC. To build a memory profile, we reverse engineer the communication protocol and conduct differential analysis to gain knowledge about the structure of the memory and the low-level representation of control logic instructions. We then identify dynamic and static memory regions by modifying different project fields and conducting differential analysis, which allows us to identify boundaries of critical memory structures and extract important forensic artifacts that can be found in the memory. The Python implementation of the memory profile can help reduce the time and effort required for manual analysis in case of cyber incident or system failure.

97 MATHEMATICS AND COMPUTING↗

5G Securely Energized and Resilient: (5G-SER) (Final Report)

NREL's work on 5G integration with physical power systems (versus simulated systems demonstrated in task 3) under 5G-Securely Energized and Resilient (5G-SER) achieved a major milestone in with the completion of Task 4 activities. After many months (6+) of planning and development along with scaling challenges along the way, a full 5G end-to-end network with physical hardware components (physical inverter, physical power panel, physical battery, etc.) was deployed in a containerized environment. In parallel, a distributed controls architecture for a microgrid powering 5G resources was also successfully modified from its previous instantiation for a simulated environment to work with these physical components. These accomplishments set the stage to use newly setup 5G technology with physical microgrid components to test the feasibility of 5G wireless with physical systems to enable resilient communications between controls and distributed solar and storage resources while exploring ways to configure 5G components to survive power disturbances. The results detailed in the report below show that even utilizing physical components, 5G wireless systems were able to provide resilient results that were similar to the results from the simulated environment Task 3).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhancing Power Resilience for Remote Communities: A Comprehensive Renewable Energy Solution for Itbayat Island

The island of Itbayat, Philippines, faces significant challenges in maintaining a reliable and resilient power supply due to its current reliance on a vulnerable power distribution system managed by a local electric cooperative. The existing infrastructure, which includes diesel generators and a radial network configuration with some above-ground lines, is highly susceptible to frequent typhoons and adverse weather conditions. These factors, combined with inadequate staffing and high operational costs, result in frequent power outages that disrupt daily life and hinder economic development. This white paper proposes a comprehensive solution to enhance the resilience and reliability of Itbayat's power system by integrating renewable energy sources, specifically solar photovoltaic (PV) systems, battery storage, and a microgrid controller. The proposed solution aims to reduce dependency on diesel fuel, optimize energy use, and provide a sustainable and robust power supply for the island. Key components of the solution include: 1. Solar PV Installation: Deploying solar PV panels to harness abundant solar energy, reducing reliance on diesel fuel. 2. Battery Storage Systems: Installing battery storage to store excess solar energy and ensure a continuous power supply during low solar generation periods. 3. Microgrid Controller: Implementing a microgrid controller to manage and optimize the integration of solar PV, battery storage, and existing diesel generators. The proposed solution addresses several critical issues, including system vulnerability, generator dependency, and operational inefficiencies. By adopting this innovative approach, Itbayat Island can achieve a more resilient, efficient, and sustainable energy infrastructure, ensuring a stable power supply for its residents and enhancing overall energy security.

14 SOLAR ENERGY↗

Assembling a Cyber Range to Evaluate Artificial Intelligence / Machine Learning (AI/ML) Security Tools

In this case study, we will describe the design and assembly of a cyber security test range we have built at Oak Ridge National Laboratory in Oak Ridge, TN, USA. The range is designed to provide a flexible environment to evaluate cyber security tools—particularly those involving AI/ML—in a way that provides realistic environments and where we can control the experiments to determine the strengths and weaknesses of the tools. We have designed in the ability to repeat the evaluations, so additional tools can be evaluated and compared at a later time. The system is one that can be scaled up or down for experiment sizes. At the time of the conference we will have completed two full-scale, national, government challenges on this range. These challenges are evaluating the performance and operating costs for AI/ML-based cyber security tools for application into large, government-sized environments. These evaluations will be described, in order to provide motivation and context for various design decisions and adaptations we have made. The first challenge measured end-point security tools against 100K malware samples chosen across a range of types. The second is network detection of attempted penetration and exploitations with varying levels of covertness in a high-volume, business network. The scale of each of these challenges is requiring us to create automation systems to repeat the experiments identically for each tool. Preventing there being easy signs of malicious activity for the AI/ML tools to focus on has been a particularly interesting and challenging aspect of designing and executing these challenge events. After the events, the range continues to be used for other research such as adversarial machine learning where the repeatability, scale, and automation required for the national challenge events become essential elements for research.

Nichols, Jeff↗

Streamlined Approach for Environmental Restoration (SAFER) Plan for Corrective Action Unit 114: Area 25 EMAD Facility Nevada National Security Site, Nevada, (Rev.0, with ROTC 1)

This Streamlined Approach for Environmental Restoration (SAFER) Plan addresses the actions needed to achieve closure for Corrective Action Unit (CAU) 114, Area 25 EMAD Facility, identified in the Federal Facility Agreement and Consent Order (FFACO). CAU 114 comprises the following corrective action sites (CASs) located in Area 25 of the Nevada National Security Site (formerly, the Nevada Test Site): 25-41-03, EMAD Facility; 25-99-23, Manned Control Car (MCC) and Engine Installation Vehicle (EIV); and 25-33-05, Building 3901, Engine Transport System Maintenance Building. This plan provides the methodology for field activities needed to gather the necessary information for closing CAU 114. There is sufficient information and process knowledge from historical documentation and investigations of similar sites regarding the expected nature and extent of potential contaminants to recommend closure of CAU 114 using the SAFER process. Additional information will be obtained by conducting a field investigation before selecting the appropriate corrective actions for CAU 114. It is anticipated that the results of the field investigation and implementation of corrective actions will support a defensible recommendation that no further corrective action is necessary. The purpose of the corrective action investigation will be to document and verify the adequacy of existing information; to affirm the decision for either clean closure, closure in place, or no further action; and to provide sufficient data to implement the corrective action. The actual corrective action selected will be based on characterization activities implemented under this SAFER Plan. If specific conditions or findings fall outside the bounds of the SAFER Plan, the Nevada Division of Environmental Protection (NDEP) will be consulted to determine the path forward before proceeding. Upon completion of SAFER activities, a closure report will be prepared and submitted to NDEP for review and approval. The schedule for completion of the closure report will be established at the FFACO annual meeting.

54 ENVIRONMENTAL SCIENCES↗

CYVET: A Cyber-Physical Assurance Framework Based on a Semi-Supervised Vetting Approach

The project is designed to directly address the needs described in the Topic Area 4 (“Cybersecurity Verification and Validation”) of the CEDS’19 Research Call. The proposed CYVET system directly addresses the need to elevate the current industry capabilities to verify and validate OT cybersecurity and associated control system infrastructure. Currently, there is a significant gap in the energy sector’s capability in that regard during infrastructure improvement, equipment procurement, and compliance certification. CYVET provides that needed capability. CYVET is device and architecture agnostic and thus broadly applicable across the energy sector. The goal of this project is to develop and deliver a cybersecurity verification and validation framework testing capability to verify and validate OT equipment, software, and the underlying control system architecture. The primary project objectives are (i) Verification: the synthesis and reconciliation of standards and vendor supplied features, (ii) Validation: the generation, execution, and presentation of testing scripts of verified security features, and (3) Demonstration: apply the developed technology capabilities for verification and validation at a relevant end-user facility in the energy sector.

Lopez Jr, Juan↗

Detection of DoS Attacks Using ARFIMA Modeling of GOOSE Communication in IEC 61850 Substations

Integration of Information and Communication Technology (ICT) in modern smart grids (SGs) offers many advantages including the use of renewables and an effective way to protect, control and monitor the energy transmission and distribution. To reach an optimal operation of future energy systems, availability, integrity and confidentiality of data should be guaranteed. Research on the cyber-physical security of electrical substations based on IEC 61850 is still at an early stage. In the present work, we first model the network traffic data in electrical substations, then, we present a statistical Anomaly Detection (AD) method to detect Denial of Service (DoS) attacks against the Generic Object Oriented Substation Event (GOOSE) network communication. According to interpretations on the self-similarity and the Long-Range Dependency (LRD) of the data, an Auto-Regressive Fractionally Integrated Moving Average (ARFIMA) model was shown to describe well the GOOSE communication in the substation process network. Based on this ARFIMA-model and in view of cyber-physical security, an effective model-based AD method is developed and analyzed. Two variants of the statistical AD considering statistical hypothesis testing based on the Generalized Likelihood Ratio Test (GLRT) and the cumulative sum (CUSUM) are presented to detect flooding attacks that might affect the availability of the data. Our work presents a novel AD method, with two different variants, tailored to the specific features of the GOOSE traffic in IEC 61850 substations. The statistical AD is capable of detecting anomalies at unknown change times under the realistic assumption of unknown model parameters. The performance of both variants of the AD method is validated and assessed using data collected from a simulation case study. We perform several Monte-Carlo simulations under different noise variances. The detection delay is provided for each detector and it represents the number of discrete time samples after which an anomaly is detected. In fact, our statistical AD method with both variants (CUSUM and GLRT) has around half the false positive rate and a smaller detection delay when compared with two of the closest works found in the literature. Our AD approach based on the GLRT detector has the smallest false positive rate among all considered approaches. Whereas, our AD approach based on the CUSUM test has the lowest false negative rate thus the best detection rate. Depending on the requirements as well as the costs of false alarms or missed anomalies, both variants of our statistical detection method can be used and are further analyzed using composite detection metrics.

IEC 61850 electrical substations↗

Grid Cyber-Security Strategy in an Attacker-Defender Model

The progression of cyber-attacks on the cyber-physical system is analyzed by the Probabilistic, Learning Attacker, and Dynamic Defender (PLADD) model. Although our research does apply to all cyber-physical systems, we focus on power grid infrastructure. The PLADD model evaluates the effectiveness of moving target defense (MTD) techniques. We consider the power grid attack scenarios in the AND configurations and OR configurations. In addition, we consider, for the first time ever, power grid attack scenarios involving both AND configurations and OR configurations simultaneously. Cyber-security managers can use the strategy introduced in this manuscript to optimize their defense strategies. Specifically, our research provides insight into when to reset access controls (such as passwords, internet protocol addresses, and session keys), to minimize the probability of a successful attack. Our mathematical proof for the OR configuration of multiple PLADD games shows that it is best if all access controls are reset simultaneously. For the AND configuration, our mathematical proof shows that it is best (in terms of minimizing the attacker's average probability of success) that the resets are equally spaced apart. We introduce a novel concept called hierarchical parallel PLADD system to cover additional attack scenarios that require combinations of AND and OR configurations.

97 MATHEMATICS AND COMPUTING↗

Security Enhancements for Distributed Energy Resource Systems Interconnected with Distribution Networks: Final Technical Report

The revised IEEE 1547 Standard defines new complex communication-adjustable voltage and frequency regulation and ride-through characteristics, while maintaining the general antiislanding requirement for unintentional islanding situations. Unintentional islanding is prohibited while intentional islanding is specifically allowed, thus effectively enabling microgrid operation mode. Further, IEEE 1547-2018 Standard introduces new requirements in terms of interoperability so that the DER plant/circuit segments may be seamlessly integrated with the utility networks but at the same time become vulnerable to a cyber-attack. Traditional cybersecurity measures including encryption, authentication and role-based access control may not be fully implementable to all communication protocols specified in the IEEE 1547 Standard. Therefore, in this project we have identified, researched, implemented and tested several cyberphysical approaches that rely mostly on the behavior of the DER circuit and may help with validating the incoming command and control action potentially coming through an insecure communications channel. Additionally, we have built semantic models and communications profiles for DER facilities and have implemented lightweight IEC 61850 based publisher-subscriber GOOSE messaging mechanism, with security extensions in terms of authentication and encryption. The project proposed information models for integration into UCA OpenFMB 2.0 profiles focusing on grid code compliance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Implementation Aspects of Smart Grids Cyber-Security Cross-Layered Framework for Critical Infrastructure Operation

Communication networks in power systems are a major part of the smart grid paradigm. It enables and facilitates the automation of power grid operation as well as self-healing in contingencies. Such dependencies on communication networks, though, create a roam for cyber-threats. An adversary can launch an attack on the communication network, which in turn reflects on power grid operation. Attacks could be in the form of false data injection into system measurements, flooding the communication channels with unnecessary data, or intercepting messages. Using machine learning-based processing on data gathered from communication networks and the power grid is a promising solution for detecting cyber threats. In this paper, a co-simulation of cyber-security for cross-layer strategy is presented. The advantage of such a framework is the augmentation of valuable data that enhances the detection as well as identification of anomalies in the operation of the power grid. The framework is implemented on the IEEE 118-bus system. The system is constructed in Mininet to simulate a communication network and obtain data for analysis. A distributed three controller software-defined networking (SDN) framework is proposed that utilizes the Open Network Operating System (ONOS) cluster. According to the findings of our suggested architecture, it outperforms a single SDN controller framework by a factor of more than ten times the throughput. This provides for a higher flow of data throughout the network while decreasing congestion caused by a single controller’s processing restrictions. Furthermore, our CECD-AS approach outperforms state-of-the-art physics and machine learning-based techniques in terms of attack classification. The performance of the framework is investigated under various types of communication attacks.

cross-layered↗

Cybersecurity concerns for the energy sector in the maritime domain

The world has seen a number of high-profile maritime disasters in recent months and years, and has felt the impact of them. At the same time, the world has also seen a number of high-profile cyberattacks. It has felt their impact, as well. And, likely no sector has been more affected by the maritime and cyber incidents than the energy sector, as fuel prices often spike or trough, and access to energy resources can become an instant source of concern, tension, or even conflict. As energy sectors—in all their forms—continue to rely on the maritime domain or even increase that reliance, they must be mindful that traditional maritime threats—like piracy, theft, and weather events—are not the only threats they face today. Maritime cybersecurity concerns are among the most potentially disruptive to energy-sector interests and, yet, are among the least understood and least addressed. This paper identifies nine areas in which the energy sector faces harmful cyber vulnerabilities in the maritime domain, to provide enough insight and examples to allow for action to be taken to reduce the risk of harm from these different vulnerabilities. The paper develops the example of offshore wind energy to model how to assess cyber considerations more fully. Ultimately, it concludes with a series of recommendations that offer policymakers, energy-sector actors, and security and law-enforcement professionals steps to minimize the exposure of the maritime energy sector to harmful cyberattacks.

99 GENERAL AND MISCELLANEOUS↗

Gridtrust: Electricity Grid Root-of-Trust Decentralized Supply Chain Cyber-Security (Final Scientific/Technical Report)

GridTrust represents a departure from reliance on a single organization or a single person to multiple organizations and therefore multiple people across organizational structures. The motivating idea behind involving multiple organizations is the increase in security due to human factors. More specifically, the requirement that distinct people in different organizations sign off on a change or an update makes a cyberattack much less likely due to the inherent requirement that both organizations be penetrated and fooled. GridTrust focuses on the software update process as the primary exemplar for the research and development work. A novel hardware-based technology referred to as a Physical Unclonable Function (PUF) provides a microchip Root-of-Trust (RoT), i.e., a starting point for verifying that the hardware being communicated with is the hardware the control center believes the hardware to be. As a result, staff at power grid control centers can ensure the accurate and reliable identification of hardware devices from the outset. The GridTrust protocol introduces two key innovations, as detailed in this report. Firstly, the utilization of a PUF as a root-of-trust in the initial phase of a software or firmware update. Secondly, the application of multiple cryptographic signatures from two or more organizations to the update binary. These signatures are verified before implementing the update on a power grid device in the field. In terms of GridTrust hardware design, this report outlines two main components. The first is the GridTrust Native Device, integrating PUF technology intrinsically into the hardware device itself. The second is the GridTrust Interfacing Device, which incorporates PUF technology and multiple cryptographic signatures. These signatures are cross-checked within a separate hardware positioned between the power grid control center and the legacy power grid device, functioning as an intermediary. While the GridTrust Interfacing Device offers the advantage of being applicable to existing power grid equipment, it may have reduced security if the intermediary component is targeted. On the other hand, the GridTrust Native Device boasts increased security due to protocol integration within a unified form factor. The effectiveness of GridTrust technology has been extensively demonstrated, with multiple external red-team attackers unable to breach GridTrust's security measures. This was observed both in controlled laboratory settings during Phase 1 of the project and in real-world conditions within a City of Marietta substation during Phase 2 of the project.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Independent Review of the Proof-of-Concept Cyber100 Compass Cybersecurity Risk Tool

The U.S. Department of Energy (DOE) Office of Cybersecurity, Energy Security, and Emergency Response (CESER), and Office of Electricity (OE) commissioned the National Renewable Energy Laboratory (NREL) to develop a method and tool to enable electric utilities to understand and manage the risk of cybersecurity events that can lead to physical effects like blackouts. This tool, called Cyber100 Compass, uses cybersecurity data elicited from cybersecurity experts, then incorporates that data into a tool designed to be usable by cybersecurity non-experts who understand the system itself. The tool estimates dollar-valued risks for a current or postulated future electric power digital control configuration, in order to enable utility risk planners to prioritize among proposed cybersecurity risk mitigation options. With the development of the Cyber100 Compass tool for quantification of future cyber-physical security risks, NREL has taken an initial bold step in the direction of enabling and indeed encouraging electric utilities to address the potential for cybersecurity incidents to produce detrimental physical effects related to electric power delivery. As part of the Cyber100 Compass development process, DOE funded NREL to seek out an independent technical review of the risk methodology embodied in the tool. NREL requested this review from Sandia National Laboratories, and made available to Sandia a very late version of the project report, as well as NREL personnel to provide clarification and to respond to questions. This paper provides the result of the independent review activity.

97 MATHEMATICS AND COMPUTING↗

Cyber-Physical Resiliency for Wind Power Generation

During the next three years, wind power generation is expected to add more generation capacity to the national electrical grid than any other energy sector. With new wind turbine designs rated power over 10 MW and wind farms reaching over 1 GW capacities, the consequences of cyber-attacks on wind power generation are becoming increasingly more critical. Moreover, the known vulnerabilities of wind turbine control systems and the potential damaging effects of intrusions, motivate an urgent protection improvement for the wind power generation sector. This program has developed a variety of new adaptive defense technologies that enable wind power generation systems to survive sophisticated cyberattacks by enhancing the control systems capabilities of detection, localization, and accommodation. The introduction of these technologies in the on-shore and the emerging off-shore market will result in a significantly more reliable and secure wind power infrastructure.

17 WIND ENERGY↗

Engineering Out Industry 4.0 Cyber Risk Presentation for EnCyCriS

The increasing complexity and business requirements of operational technology (OT) devices is beginning to break the normal segmentation between information technology (IT) and OT networks. The introduction of industry 4.0 devices such as industrial internet of things (IIoT) and other intelligent industrial devices (IID), virtualized OT systems, OT cloud integration, and artificial intelligence (AI)-driven industrial control systems (ICS) has challenged traditional IT/OT cybersecurity strategies. Industry 4.0 devices are analyzed through the lens of well-regarded models such as the PERA model and confidentiality, integrity, and availability (CIA) security objectives, showing the division between what is needed and traditional cybersecurity countermeasures. In this paper, the practice of Cyber-Informed Engineering (CIE) is proposed to bridge the gap between IT/OT security, enhance the practice of cybersecurity in this modern age, and reduce the impacts of consequential events in OT.

99 GENERAL AND MISCELLANEOUS↗