At least 361 records · Page 20

A necessary condition of Pontryagin type for fuzzy control systems

In the present paper, we prove necessary optimality conditions of Pontryagin type for a class of fuzzy optimal control problems. The new results are illustrated by computing the extremals of two fuzzy optimal control systems, which improve recent results of Najariyan and Farahi.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Trustworthiness modeling and evaluation for a nearly autonomous management and control system

The Nearly Autonomous Management and Control (NAMAC) system supports the advanced reactor operation by recommending control actions to operators based on real-time measurements and digital twins (DTs) learning from the knowledge base. To enable the safe and reliable use of autonomous technologies, NAMAC and its recommendations should be trustworthy to operators and regulators at both the design and operation stages. This study proposes a NAMAC trustworthiness modeling and evaluation framework supported by trustworthiness ontologies and evidence-based approaches. The development-time and run-time ontologies are separately constructed and then converted to Bayesian networks to quantitatively evaluate the NAMAC trustworthiness. This evaluation is demonstrated by collecting and characterizing evidence from NAMAC practices, such as the development and assessment of the NAMAC system, data coverage assessment, and the training and optimizations of neural-network-based DTs. Our proposed approach can aggregate various trustworthiness attributes of complex artificial-intelligence-supported systems for safety-critical applications. It also considers the interaction between different DTs and extends beyond the trustworthiness evaluation of a single DT. In conclusion, the evidence-based method enhances the transparency of the trustworthiness modeling and evaluation processes and helps identify uncertainties and subjectivity involved in the processes.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Distributed Timing and Triggering Control System

This document is a slide show type presentation regarding the need and realization of a new control system for work at the Nevada National Security Site. Commercial products that met the need are identified, both hardware and software. Particular emphasis is on the Integrated Signal Programmer.

42 ENGINEERING↗

A Markov Model for Assessing the Reliability of a Digital Feedwater Control System

A Markov approach has been selected to represent and quantify the reliability model of a digital feedwater control system (DFWCS). The system state, i.e., whether a system fails or not, is determined by the status of the components that can be characterized by component failure modes. Starting from the system state that has no component failure, possible transitions out of it are all failure modes of all components in the system. Each additional component failure mode will formulate a different system state that may or may not be a system failure state. The Markov transition diagram is developed by strictly following the sequences of component failures (i.e., failure sequences) because the different orders of the same set of failures may affect the system in completely different ways. The formulation and quantification of the Markov model, together with the proposed FMEA (Failure Modes and Effects Analysis) approach, and the development of the supporting automated FMEA tool are considered the three major elements of a generic conceptual framework under which the reliability of digital systems can be assessed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Upgrading the Data Acquisition and Control System of the LANSCE LINAC

Los Alamos National Laboratory LANL is in the process of upgrading the control system for the Los Alamos Neutron Science Center (LANSCE) linear accelerator. The 38 year-old data acquisition and control equipment is being replaced with COTS hardware. An overview of the current system requirements and how the National Instruments cRIO system meets these requirements will be given, as well as an update on the installation and operation of a prototype system in the LANSCE LINAC.

Accelerator Design, Technology, and Operations↗

Designing a Magnetic Measurement Data Acquisition and Control System With Reuse in Mind: A Rotating Coil System Example

Accelerator magnet test facilities frequently need to measure different magnets on differently equipped test stands and with different instrumentation. Designing a modular and highly reusable system that combines flexibility built-in at the architectural level as well as on the component level addresses this need. Specification of the backbone of the system, with the interfaces and dataflow for software components and core hardware modules, serves as a basis for building such a system. The design process and implementation of an extensible magnetic measurement data acquisition and control system are described, including techniques for maximizing the reuse of software. The discussion is supported by showing the application of this methodology to constructing two dissimilar systems for rotating coil measurements, both based on the same architecture and sharing core hardware modules and many software components. The first system is for production testing 10 m long cryo-assemblies containing two MQXFA quadrupole magnets for the high-luminosity upgrade of the Large Hadron Collider and the second for testing IQC conventional quadrupole magnets in support of the accelerator system at Fermilab.

43 PARTICLE ACCELERATORS↗

INDUSTRIAL CONTROL SYSTEM CYBER SECURITY: QUESTIONS AND ANSWERS RELEVANT TO NUCLEAR FACILITIES, SAFEGUARDS AND SECURITY

Typical questions surrounding industrial control system (ICS) cyber security always lead back to: What could a cyber attack do to my system(s) and; how much should I worry about it? These two leading questions represent only a fraction of questions asked when discussing cyber security as it applies to any program, company, business, or organization. The intent of this paper is to open a dialog of important pertinent questions and answers that managers of nuclear facilities engaged in nuclear facility security and safeguards should examine, i.e., what questions should be asked; and how do the answers affect an organization's ability to effectively safeguard and secure nuclear material. When a cyber intrusion is reported, what does that mean? Can an intrusion be detected or go un-noticed? Are nuclear security or safeguards systems potentially vulnerable? What about the digital systems employed in process monitoring, and international safeguards? Organizations expend considerable efforts to ensure that their facilities can maintain continuity of operations against physical threats. However, cyber threats particularly on ICSs may not be well known or understood, and often do not receive adequate attention. With the disclosure of the Stuxnet virus that has recently attacked nuclear infrastructure, many organizations have recognized the need for an urgent interest in cyber attacks and defenses against them. Several questions arise including discussions about the insider threat, adequate cyber protections, program readiness, encryption, and many more. These questions, among others, are discussed so as to raise the awareness and shed light on ways to protect nuclear facilities and materials against such attacks.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Industrial control system device classification using network traffic features and neural network embeddings

Characterization of modern cyber–physical Industrial Control System (ICS) devices is critical to the evaluation of their security posture and an understanding of the underlying industrial processes with which they interact. In this work, we address two related ICS device identification tasks: (1) separating ICS from non-ICS devices and (2) identifying specific ICS device types. We propose two distinct methods (one based on the existing IP2Vec method, and a novel traffic-features-based method) for achieving the first task. For transferability of the first task between two datasets, the traffic-features-based method performs significantly better (75% overall accuracy) compared to IP2Vec (22.5% overall accuracy). We further propose a novel method called DNP2Vec to address the second task. DNP2Vec is evaluated on two different datasets and achieves perfect multi-class classification accuracy (100%) for both datasets.

42 ENGINEERING↗

Recent results from a testbed for the reliability of the digital instrumentation and control systems and cybersecurity in nuclear power plants - 392

Transition from analog to digital instrumentation and control systems requires a systematic study of the modifications, and assessment of their reliability. Such studies are often carried out on a test bed. The test bed developed earlier includes a commercially available triple modular redundant (TMR) programmable logic controller (PLC) for testing not only the reliability of the digital I and C but also the cyber-security of the system during plant operation. This paper reports results of our preliminary analyses carried out using the test bed following the injection of faults mimicking faulty sensors. The fault injection tool generates faulty signals in single or multiple sensors located in the primary loop. These scenarios studied under steady-state operation conditions simulate a bad sensor, a cut wire, noise, etc. The faults injected can lead to information being displayed in the main control room (MCR) to not match the conditions in the plant. In addition to a fault injection module, a result analyzer module is also a part of this testbed. Operator actions can be based on information displayed in the MCR, or they can be informed by the result analyzer. Potential operator actions following these single- or multiple faulty signals are assessed. It is concluded that the result analyzer in some cases can be helpful in guiding operators to make the right decisions. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Online monitoring of rod control systems in combustion engineering pressurized water reactors - 195

Current designs of Pressurized Water Reactors (PWRs) are equipped with control and shutdown rods that are inserted and withdrawn from the reactor core to control reactivity. In Combustion Engineering (CE) plants, these rods are moved using the Control Element Drive Mechanism (CEDM) and controlled by the CEDM Control System (CEDMCS). In the event of system failure, troubleshooting activities can have a substantial impact on plant resources. Furthermore, CEDM component failures have occurred without warning, which has led to increased costs for the plants. These issues, combined with the inherently complex design of the CEDMCS, create a need for an online diagnostics system that can improve system health monitoring, increase diagnostic capabilities, and decrease troubleshooting time. This paper describes an advanced analysis and diagnostics system that monitors the CEDMCS during plant operation and provides critical information to onsite personnel to help detect and prevent problems before they impact normal plant operation. This system uses existing CEDMCS test points to acquire data and needs no modifications to the CEDMCS for implementation. The online monitoring capabilities automatically collect data during normal operation and diagnose failure events, reduce troubleshooting time and provide plant personnel with valuable information which is not currently available. Additionally, the system has built-in features used to streamline routine surveillance testing, collect stationary and movement data on multiple rods simultaneously, automate analysis, and generate reports. This system was developed with input from industry CEDMCS engineers at existing commercial facilities and has been deployed in multiple operating nuclear plants. The system has demonstrated itself to be a valuable tool for CEDMCS health monitoring, not only in reducing required man-power for routine system testing, but also in detected impending coil faults and allowing plant engineers to mitigate system component failures to prevent impending plant shut downs. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

DIRECT RF SAMPLING BASED LLRF CONTROL SYSTEM FOR C-BAND LINEAR ACCELERATOR

Low Level RF (LLRF) control systems of linear accel- erators (LINACs) are typically implemented with hetero- dyne based architectures, which have complex analog RF mixers for up and down conversion. The Gen 3 Radio Fre- quency System-on-Chip (RFSoC) device from AMD Xilinx integrates data converters with maximum RF frequency of 6 GHz. This enables direct RF sampling of C-band LLRF signal typically operated at 5.712 GHz without any analogue mixers, which can significantly simplify the system architec- ture. The data converters sample RF signals in higher order Nyquist zones and then up or down convert digitally by the integrated data path in RFSoC. The closed-loop feedback control firmware implemented in FPGA integrated in RF- SoC can process the base-band signal from the ADC data path and calculate the updated phase and amplitude to be up- mixed by the DAC data path. We have developed a C-band LLRF control RFSoC platform with direct RF sampling, which targets Cool Copper Collider (𝐶3) and other C or S band LINAC research and development projects. In this paper, the architecture of the platform will be described. We have optimized the configuration of the data converter and characterized performance of them with RF pulses. The test results for some of the key performance parameters for the LLRF platform with our custom solid-state amplifier, such as phase and amplitude stability, will be discussed in this paper.

Liu, C↗

Syntheses of terminal control for nonlinear stationary controlled system under incomplete information

By constructing a Luenberger-type asymptotic observer, a method of finding the control function, that ensures the translation of a class of nonlinear stationary control systems of ordinary differential equations from the initial state to a given final state taking into account the actual measured values, was developed. A constructive criterion guaranteeing the existence of solution of this problem was found. An algorithm is proposed for constructing a control function that transfer wide class of nonlinear systems of ordinary differential equations from an initial state to an fixed state. The algorithm is convenient for numerical implementation. A constructive condition is obtained for which this transfer is possible.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Recent Developments of the Modelica"Buildings" Library for Building Energy and Control Systems

At the Modelica 2009 conference, we introduced the Buildings library, a freely available Modelica library for building energy and control systems. This paper reports the updates of the library and presents example applications for a range of heating, ventilation and air conditioning (HVAC) systems. Over the past two years, the library has been further developed. The number of HVAC components models has been doubled and various components have been revised to increase numerical robustness.The paper starts with an overview of the library architecture and a description of the main packages. To demonstrate the features of the Buildings library, applications that include multizone airflow simulation as well as supervisory and local loop control of a variable air volume (VAV) system are briefly described. The paper closes with a discussion of the current development.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Recovery Linac: Controls System

This paper examines the equipment and software from which the controls system interface for the Energy Recovery Linac (ERL) will be implemented at the Brookhaven National Laboratory.

43 PARTICLE ACCELERATORS↗

Device Classification for Industrial Control Systems Using Predicted Traffic Features

To achieve a secure interconnected Industrial Control System (ICS) architecture, security practitioners depend on accurate identification of network host behavior. However, accurate machine learning based host identification methods depends on the availability of significant quantities of network traffic data, which can be difficult to obtain due to system constraints such as network security, data confidentiality, and physical location. In this work, we propose a network traffic feature prediction method based on a generative model, which achieves high host identification accuracy. Furthermore, we develop a joint training algorithm to improve host identification performance compared to separate training of the generative model and the classifier responsible for host identification.

97 MATHEMATICS AND COMPUTING↗

Non-contact temperature control system for microfluidic devices

The present invention relates to a temperature control system for a microfluidic device. The system allows for non-contact heating by employing an infrared emitter. In some instances, the system can be used in conjunction with a centrifugal microfluidic device. Optionally, a mask can be implemented to provide selective heating of desired assay areas of the device.

Phaneuf, Christopher↗

Using EPICS enabled industrial hardware for upgrading control systems

Los Alamos National Laboratory has been working with National Instruments (NI) and Cosy lab to implement EPICS Input Output Controller (IOC) software that runs directly on NI CompactRIO Real Time Controller (RTC) and communicates with NI LabVIEW through a shared memory interface. In this presentation, we will discuss our current progress in upgrading the control system at the Los Alamos Neutron Science Centre (LANSCE) and what we have learned about integrating CompactRIO into large experimental physics facilities. We will also discuss the implications of using Channel Access Server for LabVIEW which will enable more commercial hardware platforms to be used in upgrading existing facilities or in commissioning new ones.

43 PARTICLE ACCELERATORS↗

Design of a Novel Information System for Semi-Automated Management of Cybersecurity in Industrial Control Systems

There is an urgent need in many critical infrastructure sectors, including the energy sector, for attaining detailed insights into cybersecurity features and compliance with cybersecurity requirements related to their Operational Technology (OT) deployments. Frequent feature changes of OT devices interfere with this need, posing a great risk to customers. One effective way to address this challenge is via a semi-automated cyber-physical security assurance approach, which enables verification and validation of the OT device cybersecurity claims against actual capabilities, both pre- and post-deployment. To realize this approach, this paper presents new methodology and algorithms to automatically identify cybersecurity-related claims expressed in natural language form in ICS device documents. Here, we developed an identification process that employs natural language processing (NLP) techniques with the goal of semi-automated vetting of detected claims against their device implementation. We also present our novel NLP components for verifying feature claims against relevant cybersecurity requirements. The verification pipeline includes components such as automated vendor identification, device document curation, feature claim identification utilizing sentiment analysis for conflict resolution, and reporting of features that are claimed to be supported or indicated as unsupported. Our novel matching engine represents the first automated information system available in the cybersecurity domain that directly aids the generation of ICS compliance reports.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗