Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Configurable lighting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Physical correction filter for improving the optical quality of an image

A family of physical correction filters is described. Each filter is designed to correct image content of a photographed scene of limited resolution and includes a first filter element with a pinhole through which light passes to a differential amplifier. A second filter element through which light passes through one or more openings, whose geometric configuration is a function of the cause of the resolution loss included. The light, passing through the second filter element, is also supplied to the differential amplifier whose output is used to activate an optical display or recorder to reproduce a photograph or display of the scene in the original photograph or display of the scene in the original photograph with resolution which is significantly greater than that characterizing the original photograph.

Lee, S. Y.↗

Realization of a single and closed {lambda}-system in a room-temperature three-level coherently prepared resonant medium with narrow D{sub 1} hyperfine splittings

A single, closed three-state {lambda}-system in room-temperature rubidium is investigated experimentally using a copropagating beam parallel-polarization configuration under weakly driven electromagnetically induced transparency (EIT) condition. Compare with the widely used orthogonal-polarization beam EIT configuration where multiple nonclosed {lambda}-schemes coexist, the parallel-polarizations configuration can completely eliminate the leakage light from the control field. Our state preparation and laser polarization lead to a single and closed {lambda}-scheme that eliminates the detrimental absorption due to nearby states in atomic species with hyperfine separations smaller than Doppler-broadened line widths, a case where the conventional EIT configuration fails completely.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of miniaturized, spectroscopically assisted Penning gauges for fractional helium and hydrogen neutral pressure measurements

Direct measurements of the helium (He) fractional neutral pressure in the neutral gas around fusion devices is challenging because of the small mass difference between the abundant D{sub 2} molecules and the He ash which will be produced by deuterium-tritium fusion. To study He exhaust, an in situ Penning gauge system is being developed at UW-Madison that is optimized for good pressure and high spectroscopic sensitivity. Three different anode geometries have been studied regarding their vacuum electrostatic fields, light output, and ion current. The light output of the two new anode configurations are at least one order of magnitude above the currently available designs, hence improving the spectroscopic sensitivity at similar total neutral pressure resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LADEE UVS Observations of Atoms and Dust in the Lunar Tail

The Lunar Atmosphere and Dust Environment Explorer (LADEE) was a lunar orbiter launched in September 2013 that investigated the composition and temporal variation of the tenuous lunar exosphere and dust environment. A major goal of the mission was to characterize the dust exosphere prior to future lunar exploration activities, which may alter the lunar environment. The Ultraviolet/Visible Spectrometer (UVS) onboard LADEE addresses this goal, utilizing two sets of optics: a limbviewing telescope, and a solar-viewing telescope. We report on spectroscopic (approximately 280 - 820 nm) observations viewing down the lunar wake or along the 'lunar tail' from lunar orbit. Prior groundbased studies have observed the emission from neutral sodium atoms extended along the lunar tail, so often this region is referred to as the lunar sodium tail. UVS measurements were made on the dark side of the moon, with the UVS limb-viewing telescope pointed outward in the direction of the Moon's wake (almost anti-sun), during different lunar phases. These UVS observation activities sample a long column and allow the characterization of scattered light from dust and emission lines from atoms in the lunar tail. Observations in this UVS configuration show the largest excess of scattered blue light in our data set, indicative of the presence of small dust grains in the tail. Once lofted, nanoparticles may become charged and picked up by the solar wind, similar to the phenomena witnessed above Enceladus's northern hemisphere or by the STEREO/WAVES instrument while close to Earth's orbit. The UVS data show that small dust grains as well as atoms become entrained in the lunar tail.

Dust and Solar Wind↗

Evaluation of optical imaging and spectroscopy approaches for cardiac tissue depth assessment

NIR light scattering from ex vivo porcine cardiac tissue was investigated to understand how imaging or point measurement approaches may assist development of methods for tissue depth assessment. Our results indicate an increase of average image intensity as thickness increases up to approximately 2 mm. In a dual fiber spectroscopy configuration, sensitivity up to approximately 3 mm with an increase to 6 mm when spectral ratio between selected wavelengths was obtained. Preliminary Monte Carlo results provided reasonable fit to the experimental data.

59 BASIC BIOLOGICAL SCIENCES↗

Development of photocatalyst by combined nitrogen and yttrium doping

Graphical abstract: The simulated compensated YN{sub SUB} co-doped TiO{sub 2} model can reasonably explain the experimental observations. Calculation results show that substitutional Y at Ti sites and substitutional N at O sites with an oxygen vacancy give stable configuration, reduced band gap, better visible light absorption and enhance separations of photoexcited charge carriers. The experimental observations confirmed the theoretical findings. - Highlights: • (Y, N) codoped TiO{sub 2} was synthesized by mild one pot hydrothermal method. • The Y doping concentration was varied from 0.01 to 1.38 at%. • 0.05% (Y, N) codoped TiO{sub 2} shows enhanced visible light photocatalytic activity. • Compensated and noncompensated ab-initio calculations were performed. • Calculation results reasonably explained the experimental findings. - Abstract: Titanium dioxide co-doped with yttrium and nitrogen with different yttrium doping concentration has been synthesized by mild one pot hydrothermal method without any post calcination for crystallization. Irrespective of the yttrium doping concentration, all the synthesized samples were composed of pure anatase phase with good crystallinity. And the synthesized co-doped samples have spherical morphology with uniform particle size distribution. The absorption edge of the co-doped TiO{sub 2} was shifted toward visible light region depicting that the intrinsic band gap of TiO{sub 2} was affected by the co-doping. Among the different samples, the co-doped sample with 0.05% yttrium doping concentration exhibits enhanced visible light photocatalytic activity by degradation of methylene blue in aqueous solution. Compensated and non-compensated yttrium–nitrogen co-doped TiO{sub 2} models were simulated using density functional theory to explain the experimental findings. The calculation results show that the compensated yttrium–nitrogen co-doped TiO{sub 2} model may reasonably explain the experimental observations due to its stable configuration, narrowed band gap and enhanced separation of photoexcited carriers.

36 MATERIALS SCIENCE↗

Cost of Oil and Biomass Supply Shocks under Different Biofuel Supply Chain Configurations

This analysis estimates the cost of selected oil and biomass supply shocks for producers and consumers in the light-duty vehicle fuel market under various supply chain configurations using a mathematical programing model, BioTrans. The supply chain configurations differ by whether they include selected flexibility levers: multi-feedstock biorefineries; advanced biomass logistics; and the ability to adjust ethanol content of low-ethanol fuel blends, from E10 to E15 or E05. The simulated scenarios explore market responses to supply shocks including substitution between gasoline and ethanol, substitution between different sources of ethanol supply, biorefinery capacity additions or idling, and price adjustments. Welfare effects for the various market participants represented in BioTrans are summarized into a net shock cost measure. As oil accounts for a larger fraction of fuel by volume, its supply shocks are costlier than biomass supply shocks. Corn availability and the high cost of adding biorefinery capacity limit increases in ethanol use during gasoline price spikes. During shocks that imply sudden decreases in the price of gasoline, the renewable fuel standard (RFS) biofuel blending mandate limits the extent to which flexibility can be exercised to reduce ethanol use. The selected flexibility levers are most useful in response to cellulosic biomass supply shocks.

Uria Martinez, Rocio↗

Is 1220 Crocus a precessing, binary asteroid?

Photoelectric data of the asteroid 1220 Crocus over a 13 night period in 1984 revealed the presence of two separate periods. The light curves were indicative of a precessing body, but not one in free precession due to motions induced by a collision. Closer examinations revealed periods of 30.7 and 7.9 hr with amplitudes of 0.87 and 0.15 mag, respectively. An analysis of the source of an external torque which could be causing a forced precession led to the hypothesis that 1220 Crocus has a satellite. Verification of the binary asteroid configuration will depend on more detailed light curves, the possible modulation of the shorter period by the longer, and possible use of the Space Telescope.

Binzel, R. P.↗

Simultaneous measurement of group refractive index and thickness of optical samples using optical coherence tomography

Optical coherence tomography (OCT), based on a Michelson interferometer and utilizing low coherence light as the optical source, is a novel technique for the noninvasive imaging of optical scattering media. A simple OCT scheme based on a 3x3 fiber coupler is presented for the simultaneous measurement of the refractive index and thickness of optical samples. The proposed system enables the refractive index and thickness to be determined without any prior knowledge of the sample parameters and is characterized by a simple and compact configuration, a straightforward measurement procedure, and a low cost. The feasibility of the proposed approach is demonstrated experimentally using BK7 and B270 optical glass samples.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Early Air Force Flight Test Center (AFFTC) experience with Peripheral Vision Horizon Displays (PVHD)

Three separate Air Force Flight Test Center (AFFTC) tests were conducted in 1980 and 1981 on two models of the peripheral vision horizon displays (PVHD) (Malcolm Horizon). A fixed base simulator test was conducted with twenty test pilot subjects using the Flight Simulator Demonstration Model which incorporated a Helium Neon laser as the light bar medium. Two separate flight tests were conducted by the Test Pilot School classes 80A and 80B in a Twin Otter commuter aircraft using the Stage A Model PVHD. The Xenon lighted A Model was tested in its original configuration by class 80A. Class 80B used a modified configuration which incorporated an AFFTC designed and manufactured hood. With the hood, the PVHD projected a thinner, distinct light bar. Only a few general remarks concerning the tests and unrestricted, overall conclusions reached by the author are presented. The conclusions of all three AFFTC evaluations of the PVHD concept were that it has not yet been adequately evaluated. There seems to be a significant learning curve associated with the PVHD and the project pilots for Test Pilot School Class 80B only got a good start on the learning curve. A lengthy learning curve for the PVHD should be anticipated in view of the training period required for the attitude display indicator (ADI). This does seem to point out that the PVHD, in its present form, is simply not as compelling as the natural horizon. It can also be concluded that any attempt at a valid evaluation of the PVHD concept can be done only under instrument meteorological conditions (IMC) or validly simulated IMC conditions. The knee in the learning curve, however, may be reached without full IMC, although it may take much longer to reach.

Schofield, B. L.↗

Data of heavy elements for light sources in EUV and XUV and for other applications

Atomic ionic states and transition properties of elements with atomic numbers Z ranging from 50 to 80 are discussed as these are important to the understanding of plasmas containing such heavy elements. As such, data productions and the current status of theoretical calculations in this field are discussed. Further, recent spectroscopic measurements and respective theoretical analyses for W, Gd, and Nd are provided. The spectra of photoemissions elicited by the transitions between the sub-shell levels in N-sub-shell open atomic ions are of interest for the strong influence received from the interactions between the electronic state configurations with different constituent orbitals. Visible light emissions of W from M1 as well as E2 transitions are introduced and discussed.

74 ATOMIC AND MOLECULAR PHYSICS↗

IS NSVS 5066754 A NEAR-CONTACT OR A MARGINAL CONTACT BINARY?

BVR{sub cIc} light curves of NSVS 5066754 were taken on 2014 May at Dark Sky Observatory in North Carolina. This variable is a solar-type eclipsing binary ( T 1 ∼ 5750 K) with a period of only 0.3751689(1) days. It appeared to be one of the shortest periods in Shaw’s list of near-contact binaries. The Binary Maker fits and our Wilson–Devinney solutions show that the binary could have both semidetached and marginal contact binary configurations. Five new times of minimum light were calculated, along with two minima determined from archived All Sky Automated Survey observations. From these minima and the discovery epoch, a quadratic ephemeris was determined. Thus, a magnetic braking scenario is possible. Both semidetached and contact models were explored. A marginal contact solution had the best sum of square residuals. It gave a mass ratio of ∼0.5, and a component temperature difference of ∼360 K, albeit somewhat large for a contact binary. Two substantial cool spots were determined in this solution with 37° and 28° radii and t-factors or 0.94 and 0.78 respectively. The fill-out is very shallow, ∼106%. It may have recently achieved contact.

79 ASTRONOMY AND ASTROPHYSICS↗

Birefringence lens effects of an atom ensemble enhanced by an electromagnetically induced transparency

We study the optical control for birefringence of a polarized light by an atomic ensemble with a tripod configuration, which is mediated by the electromagnetically induced transparency with a spatially inhomogeneous laser. The atomic ensemble splits the linearly polarized light ray into two orthogonally polarized components, whose polarizations depend on quantum superposition of the initial states of the atomic ensemble. Accompanied with this splitting, the atomic ensemble behaves as a birefringent lens, which allows one polarized light ray passing through straightly while focuses the other light of vertical polarization with finite aberration of focus.

74 ATOMIC AND MOLECULAR PHYSICS↗

Light Water Reactor Sustainability Program: Technical Basis Guide Describing How to Perform Safety Margin Configuration Risk Management

The INL has carried out a demonstration of the RISMC approach for the purpose of configuration risk management. We have shown how improved accuracy and realism can be achieved by simulating changes in risk – as a function of different configurations – in order to determine safety margins as the plant is modified. We described the various technical issues that play a role in these configuration-based calculations with the intent that future applications can take advantage of the analysis benefits while avoiding some of the technical pitfalls that are found for these types of calculations. Specific recommendations have been provided on a variety of topics aimed at improving the safety margin analysis and strengthening the technical basis behind the analysis process.

97 MATHEMATICS AND COMPUTING↗

A transmitting and reflecting diffuser for ultraviolet light

Fabrication of ultraviolet radiation diffusing layer in configuration that uses ultraviolet properties of fused silica condensate is discussed. Construction and operation of the device are described. Diagram of reflecting diffuser to show construction and method of operation is included.

Keafer, L. S., Jr.↗

Deep learning unresolved lensed light curves

ABSTRACT Gravitationally lensed sources may have unresolved or blended multiple images, and for time varying sources, the light curves from individual images can overlap. We use convolutional neural nets to both classify the light curves as due to unlensed, double, or quad lensed sources and fit for the time delays. Focusing on lensed supernova systems with time delays Δt ≳ 6 d, we achieve 100 per cent precision and recall in identifying the number of images and then estimating the time delays to σΔt ≈ 1 d, with a 1000× speedup relative to our previous Monte Carlo technique. This also succeeds for flux noise levels $\sim 10{{\ \rm per\ cent}}$. For Δt ∈ [2, 6] d, we obtain 94–98 per cent accuracy, depending on image configuration. We also explore using partial light curves where observations only start near maximum light, without the rise time data, and quantify the success.

79 ASTRONOMY AND ASTROPHYSICS↗

Ultraviolet (UV) light emitting device (LED) driven photocathode

An apparatus includes an electromechanical x-ray generator (MEXRAY) configured to charged capacitors using a small, high-voltage direct current. The apparatus also includes an ultraviolet (UV) light emitting diode (LED) driven photocathode device configured to control/modulate an electron dose rate of the MEXRAY or other vacuum DC, source.

Watson, Scott Avery↗