Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Clean room”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Solar Array at Very High Temperatures: Ground Tests

Solar array design for any spacecraft is determined by the orbit parameters. For example, operational voltage for spacecraft in Low Earth Orbit (LEO) is limited by significant differential charging due to interactions with low temperature plasma. In order to avoid arcing in LEO, solar array is designed to generate electrical power at comparatively low voltages (below 100 volts) or to operate at higher voltages with encapsulation of all suspected discharge locations. In Geosynchronous Orbit (GEO) differential charging is caused by energetic electrons that produce differential potential between the coverglass and the conductive spacecraft body in a kilovolt range. In such a case, the weakly conductive layer over coverglass, indium tin oxide (ITO) is one of the possible measures to eliminate dangerous discharges on array surface. Temperature variations for solar arrays in both orbits are measured and documented within the range of minus150 degrees Centigrade to plus 1100 degrees Centigrade. This wide interval of operational temperatures is regularly reproduced in ground tests with radiative heating and cooling inside a shroud with flowing liquid nitrogen. The requirements to solar array design and tests turn out to be more complicated when planned trajectory crosses these two orbits and goes closer to the Sun. The conductive layer over coverglass causes a sharp increase in parasitic current collected from LEO plasma, high temperature may cause cracks in encapsulating (Room Temperature Vulcanizing (RTV) material; radiative heating of a coupon in vacuum chamber becomes practically impossible above 1500 degrees Centigrade; conductivities of glass and adhesive go up with temperature that decrease array efficiency; and mechanical stresses grow up to critical magnitudes. A few test arrangements and respective results are presented in current paper. Coupons were tested against arcing in simulated LEO and GEO environments under elevated temperatures up to 2000 degrees Centigrade. The dependence of leakage current on temperature was measured, and electrostatic cleanness was verified for coupons with antireflection (AR) coating over the indium tin oxide (ITO) layer.

differential charging↗

COTS MEMS Flow-Measurement Probes

As an alternative to conventional tubing instrumentation for measuring airflow, designers and technicians at Glenn Research Center have been fabricating packaging components and assembling a set of unique probes that contain commercial off-the-shelf (COTS) microelectromechanical systems (MEMS) sensor chips. MEMS sensor chips offer some compelling advantages over standard macroscopic measurement devices. MEMS sensor technology has matured through mass production and use in the automotive and aircraft industries. At present, MEMS are the devices of choice for sensors in such applications as tire-pressure monitors, altimeters, pneumatic controls, cable leak detectors, and consumer appliances. Compactness, minimality of power demand, rugged construction, and moderate cost all contribute to making MEMS sensors attractive for instrumentation for future research. Conventional macroscopic flow-measurement instrumentation includes tubes buried beneath the aerodynamic surfaces of wind-tunnel models or in wind-tunnel walls. Pressure is introduced at the opening of each such tube. The pressure must then travel along the tube before reaching a transducer that generates an electronic signal. The lengths of such tubes typically range from 20 ft (approx.= 6 m) to hundreds of feet (of the order of 100 m). The propagation of pressure signals in the tubes damps the signals considerably and makes it necessary to delay measurements until after test rigs have reached steady-state operation. In contrast, a MEMS pressure sensor that generates electronic output can take readings continuously under dynamic conditions in nearly real time. In order to use stainless-steel tubing for pressure measurements, it is necessary to clean many tubes, cut them to length, carefully install them, delicately deburr them, and splice them. A cluster of a few hundred 1/16-in.- (approx.=1.6-mm-) diameter tubes (such clusters are common in research testing facilities) can be several inches (of the order of 10 cm) in diameter and could weigh enough that two technicians are needed to handle it. Replacing hard tubing with electronic chips can eliminate much of the bulk. Each sensor would fit on the tip of a 1/16-in. tube with room to spare. The Lucas NovaSensor P592 piezoresistive silicon pressure sensor was chosen for this project because of its cost, availability, and tolerance to extreme ambient conditions. The sensor chip is 1 mm square by 0.6 mm thick (about 0.039 by 0.039 by 0.024 in.) and includes 0.12-mm (approx.=0.005-in.) wire connection tabs. The figure shows a flow-angularity probe that was built by use of three such MEMS chips. It is planned to demonstrate this MEMS probe as an alternative to a standard tube-type "Cobra" probe now used routinely in wind tunnels and aeronautical hardware. This MEMS probe could be translated across a flow field by use of a suitable actuator, so that its accuracy and the shortness of its response time could be exploited to obtain precise dynamic measurements of a sort that cannot be made by use of conventional tubing-based instrumentation.

Redding, Chip↗

Methylammonium Lead Tribromide Single Crystal Detectors towards Robust Gamma-Ray Photon Sensing

In recent years, hybrid perovskite single crystalline solid-state detectors have shown promise in γ-ray spectroscopy. Here, the γ-ray photon induced electrical pulses are investigated, which are produced by perovskite solid-state detectors made with the commonly used methylammonium lead tribromide crystals with chlorine incorporation. Under low electric field detector operation, slow pulses generated by γ-rays with average rise times of 65 µs are observed, which decreases to 20 µs when a higher electrical field of 500 V cm -1 is applied. However, the baseline becomes noisy quickly, which prevents collection of clean pulses for spectra construction. Further, by systematically measuring the temperature dependence and current–voltage characteristics, such instability is attributed to the local ion migration under electrical field creating a fluctuating dark noise, which presents a major challenge in perovskite γ-ray detector technologies. It is demonstrated that cycling the bias between positive and negative polarity can stabilize the detector, allowing for longer periods of pulse accumulation for generating energy resolved spectra with resolutions of ≈35% at 59.6 keV and ≈25% at 662 keV at room temperature. The study indicates that the main limiting factors of perovskite-based γ-ray detectors are slow rise times and bias instability. Finally, these challenges must be properly addressed to achieve reproducible, high-resolution γ-ray detection.

47 OTHER INSTRUMENTATION↗

Hotel Room Computational Fluid Dynamics to Investigate Airborne Pathogen Dispersal Patterns

A hotel room unit consisting of a bedroom and bathroom was modelled using computational fluid dynamics (CFD) to investigate airborne pathogen dispersal patterns. The full-scale model includes a ‘typical’ hotel room configuration, furniture, and vents. The air sources and sinks include a bathroom vent, a heating, ventilation, and cooling (HVAC) unit located in the bedroom, and a ½” gap at the bottom of the entry door. In addition, the entry door and window can be opened or closed, as desired. Three key configuration simulations were conducted: 1) both the bathroom vent and HVAC were on, 2) only the HVAC was on, and 3) only the bathroom vent was on. If the HVAC air is from a fresh, clean source, or passes through a high-efficiency filter/UV device, then the first configuration is the safest, as contaminated air is highly reduced. The second configuration is also safe, but does not benefit from the outsourcing of potentially-infected air, such as contaminated air flowing through an ineffective filter. The third configuration should be avoided, as the bathroom vent causes air to flow from the hallway, which can be of dubious origin. The CFD simulations also showed that recirculation and swirling regions tend to accumulate the largest concentrations of heavier airborne particles, pathogens, dust, etc. These regions are associated with the largest turbulence kinetic energy (TKE) , and tend to occur in areas with flow recirculation and corners. Therefore, TKE presents a reasonable metric to guide the strategic location of pathogen mitigation devices. The simulations show complex flow patterns with distinct upper and lower flow regions, swirling flow, and significant levels of turbulent mixing. These simulations provide intriguing insights that can be applied to help mitigate pathogen aerosol dispersal, generate building design guidelines, as well as provide insights for the strategic placement of mitigation devices, such as ultraviolet (UV) light, supplemental fans, and filters.

54 ENVIRONMENTAL SCIENCES↗

Advanced Subsonic Combustion Rig Developed

The Advanced Subsonic Combustion Rig (ASCR), a unique, state-of-the-art facility for conducting combustion research, is located at the NASA Lewis Research Center in Cleveland, Ohio. The ASCR, which was nearing completion at the close of 1995, will be capable of simulating the very high pressure and high temperature conditions that are expected to exist in future, advanced subsonic gas turbine (jet) engines. Future environmental regulations will require much cleaner burning (more environmentally friendly) aircraft engines. The ASCR is critical to the development of these cleaner engines. It will allow NASA and U.S. aircraft engine industry researchers to identify and test promising clean-burning gas turbine engine combustion concepts under the pressure and temperature conditions that are expected for those future engines. Combustion processes will be investigated for a variety of next-generation aircraft engine sizes, including engines for large, long-range aircraft (with typical trip lengths of about 3000 mi) and for regional aircraft (with typical trip lengths of about 400 mi). The ASCR design was conceived and initiated in 1993, and fabrication and construction of the rig, including the buildup of an advanced control room, took place throughout 1994 and 1995. In early 1996, the ASCR will be operational for obtaining research data. The ASCR is an intricate part of the NASA Advanced Subsonic Technology Propulsion Program, which is aimed at developing technologies critical to the next generation of gas turbine engines. This effort is in collaboration with the U.S. aircraft gas turbine engine industry. A goal of the Advanced Subsonic Technology Propulsion Program is to develop combustion concepts and technologies that will result in gas turbine engines that produce 50 percent less nitrous oxide (NO_x) pollutants than current engines do. This facility is unique in its capability to simulate advanced subsonic engine pressure, temperature, and air flow rate conditions. Specifically, it will provide operating temperatures up to 3000 F and pressures up to 60 atm. Under these conditions, researchers will obtain detailed combustion temperatures, pressures, and flow velocities as well as the chemical compositions of the combustion exhaust. Researchers also will be able to obtain data by using nonintrusive laser diagnostic techniques. The ASCR facility will be used to test fundamental combustion configurations (flametubes) for detailed study of combustion processes, to test sectors of gas turbine combustors to study the process in configurations more like those of aircraft engines, and in some cases to test full annular combustors.

Source record↗

Researches on interactions of satellite-speed helium atoms with aluminum and quartz surfaces

Three major areas were experimentally studied: (1) energy transfer in collisions of satellite-speed (700 m/sec) helium atoms with a cleaned satellite-type aluminum surface was investigated using the molecular-beam technique. Spatial and energy distributions of reflected helium atoms were measured and analyzed, (2) The gross accommodation coefficient for a satellite-speed (7000 m/sec) helium beam entering a 2-inch-diameter aluminum spherical cavity was determined by measuring the exit velocity distribution of the leaving helium atoms using a metastable time-of-flight method. Results indicate that the 7000-m/sec satellite-speed helium atoms entering the cavity gain full accommodation with the room-temperature inner surface of the sphere through a large number of collisions before leaving the spherical cavity; and (3) the feasibility of producing a satellite-speed atomic hydrogen beam by arc-heating, for use in studies of interactions of satellite-surfaces with hydrogen atoms under laboratory conditions, was investigated. It was found that a stable arc-heated molecular hydrogen beam can be obtained using the arc-heater, and that a partially dissociated hydrogen beam can be produced. Photographs of laboratory equipment are shown.

Liu, S. M.↗

Method for Manufacturing Thin-film Lithium Microbatteries

A process for making thin-film batteries including the steps of cleaning a glass or silicon substrate having an amorphous oxide layer several microns thick; defining with a mask the layer shape when depositing cobalt as an adhesion layer and platinum as a current collector; using the same mask as the preceding step to sputter a layer of LiCoO2 on the structure while rocking it back and forth; heating the substrate to 300 C. for 30 minutes; sputtering with a new mask that defines the necessary electrolyte area; evaporating lithium metal anodes using an appropriate shadow mask; and, packaging the cell in a dry-room environment by applying a continuous bead of epoxy around the active cell areas and resting a glass slide over the top thereof.

Jay F Whitacre↗

Structure of Thin-Film Lithium Microbatteries

A process for making thin-film batteries including the steps of cleaning a glass or silicon substrate having an amorphous oxide layer several microns thick; defining with a mask the layer shape when depositing cobalt as an adhesion layer and platinum as a current collector; using the same mask as the preceding step to sputter a layer of LiC(0)O2, on the structure while rocking it back and forth; heating the substrate to 300 C. for 30 minutes; sputtering with a new mask that defines the necessary electrolyte area; evaporating lithium metal anodes using an appropriate shadow mask; and, packaging the cell in a dry-room environment by applying a continuous bead of epoxy around the active cell areas and resting a glass slide over the top thereof. The batteries produced by the above process are disclosed.

Jay F Whitacre↗

Detecting Airborne Mercury by Use of Palladium Chloride

Palladium chloride films have been found to be useful as alternatives to the gold films heretofore used to detect airborne elemental mercury at concentrations of the order of parts per billion (ppb). Somewhat more specifically, when suitably prepared palladium chloride films are exposed to parts-per-billion or larger concentrations of airborne mercury, their electrical resistances change by amounts large enough to be easily measurable. Because airborne mercury adversely affects health, it is desirable to be able to detect it with high sensitivity, especially in enclosed environments in which there is a risk of leakage of mercury from lamps or other equipment. The detection of mercury by use of gold films involves the formation of gold/mercury amalgam. Gold films offer adequate sensitivity for detection of airborne mercury and could easily be integrated into an electronic-nose system designed to operate in the temperature range of 23 to 28 C. Unfortunately, in order to regenerate a gold-film mercury sensor, one must heat it to a temperature of 200 C for several minutes in clean flowing air. In preparation for an experiment to demonstrate the present sensor concept, palladium chloride was deposited from an aqueous solution onto sets of gold electrodes and sintered in air to form a film. Then while using the gold electrodes to measure the electrical resistance of the films, the films were exposed, at a temperature of 25 C, to humidified air containing mercury at various concentrations from 0 to 35 ppb (see figure). The results of this and other experiments have been interpreted as signifying that sensors of this type can detect mercury in room-temperature air at concentrations of at least 2.5 ppb and can readily be regenerated at temperatures <40 C.

Ryan, Margaret↗

X-ray photoelectron spectroscopy and friction studies of nickel-zinc and manganese-zinc ferrites in contact with metals

X-ray photoelectron spectroscopy analysis and sliding friction experiments were conducted with hot-pressed, polycrystalline Ni-Zn and Mn-Zn ferrites in sliding contact with various transition metals at room temperature in a vacuum of 30 nPa. The results indicate that the coefficients of friction for Ni-Zn and Mn-Zn ferrites in contact with metals are related to the relative chemical activity in these metals: the more active the metal, the higher is the coefficient of friction. The coefficients of friction for the ferrites correlate with the free energy of formation of the lowest metal oxide. The interfacial bond can be regarded as a chemical bond between the metal atoms and the oxygen anions in the ferrite surfaces. The adsorption of oxygen on clean metal and ferrite surfaces increases the coefficients of friction for the Ni-Zn and Mn-Zn ferrite-metal interfaces.

Miyoshi, K.↗

Development of a Radiation-Tolerant Front End Digitizer

High-radiation and high-temperature environments represent notoriously detrimental conditions for electronics. Yet sensors and instrumentation are critically important for the safe operation of nuclear reactors and for the validity of the scientific experiments conducted within them. Traditionally, sensors in such extreme environments operate with few active components, resulting in small signals (mV–V, nA–µA range) that must be transmitted through long cable runs before digitization by sensitive data acquisition systems located in clean, less-harsh environments. Long cables are prone to picking up noise through electromagnetic interference and distortion caused by their parasitic impedances, resulting in signal degradation. The Front End Digitizer (FREND) system described and demonstrated herein seeks to address these issues by enabling the placement of a radiation-resistant analog front end within reactor containment, or other high-radiation environments. FREND will enable early signal pre-amplification, digitization, and optical encoding within the high-radiation field to transmit sensor signals over an optical fiber to the non-nuclear environment of an instrument room. Early signal pre-amplification and digitization maintain signal integrity, whereas optical transmission renders the system blind to induced electromagnetic noise over the long cable runs. This report describes the FREND initial prototype, which can multiplex and optically encode data from up to four sensor inputs, though, in principle, this can be extended to any number of sensor inputs. The end result is an extremely flexible, high-fidelity system.

42 ENGINEERING↗

Mesofluidic Oil-Water Separation

Separating flowing multiphase solutions in process at industrial scale is challenging. A rapid continuous approach is desired. These mesofluidic oil-water separation tests were motivated by reports by Dijkshoorn et al [1] who reported separating droplets and particles using displacement with regularly spaced channels using a cross-flow microsieve.. Droplets, including deformable particles, larger than the channel migrate in one direction and thereby deplete in the other direction. Test flowrates were motivated by Burns et al. [4] who showed that separation could occur under laminar conditions, and Pease et al [8, 9] who extended the range to turbulent flow. Testing was conducted using two two-component oil-water mixtures at room temperature. Analysis showed separation of both mineral oils from their oil water mixtures at flowrates from 1-2 L/min and concentrations from 2-10 wt% oil in water.

cloud height, effective cleaning radius, effective↗

Surface and Interface Properties of PdCr/SiC Schottky Diode Gas Sensor Annealed at 425 C

The surface and interface properties of Pd(0.9,)Cr(0.1)/SiC Schottky diode gas sensors both before and after annealing are investigated using Auger electron spectroscopy (AES), scanning electron microscopy (SEM), and energy dispersive spectroscopy (EDS). At room temperature the alloy reacted with SiC and formed Pd,Si only in a very narrow interfacial region. After annealing for 250 h ,It 425 C, the surface of the Schottky contact area his much less silicon and carbon contamination than that found on the surface of an annealed Pd/SiC structure. Palladium silicides (Pd(x)Si) formed at a broadened interface after annealing, but a significant layer of alloy film is still free of silicon and carbon. The chromium concentration with respect to palladium is quite uniform down to the deep interface region. A stable catalytic surface and a clean layer of Pd(0.9)Cr(0.1) film are likely responsible for significantly improved device sensitivity.

Chen, Liang-Yu↗

Curation of Federally Owned Archeological Collections at NASA Langley Research Center

As a Federal agency, NASA has a moral and legal obligation to the public to manage the archeological heritage resources under its control. Archeological sites are unique, nonrenewable resources that must be preserved so that future generations may experience and interpret the material remains of the past. These sites are protected by a wide array of federal regulations. These regulations are intended to ensure that our nation's cultural heritage is preserved for the study and enjoyment of future generations. Once a site has been excavated, all that remains of it are the artifacts and associated records which, taken together, allow researchers to reconstruct the past. With the contextual information provided by associated records such as field notes, maps and photographs, archeological collections can provide important information about life in the past. An integral component of the federal archeology program is the curation of these databases so that qualified scholars will have access to them in years to come. Standards for the maintenance of archeological collections have been codified by various professional organizations and by the federal government. These guidelines focus on providing secure, climate-controlled archival storage conditions for the collections and an adequate study area in which researchers can examine the artifacts and documents. In the 1970's and early 1980's, a group of NASA employees formed the LRC Historical and Archeological Society (LRCHAS) in order to pursue studies of the colonial plantations that ha been displaced by Langley Research Center (LaRC). They collected data on family histories and land ownership as well as conducting archeological surveys and excavations at two important 17th-20th century plantation sites in LaRC, Cloverdale and Chesterville. The excavations produced a wealth of information in the form of artifacts, photographs, maps and other documents. Unfortunately, interest on the part of the LRCHAS membership waned before a report was written, and since 1982 the artifacts have moldered in a flimsy trailer with no climate controls, which had once served as a field laboratory but which threatened to become a tomb for the collection. A recent analysis of Langley's cultural resources by Gray & Pape, Inc. recommended that the collection be organized, cataloged, and placed in a proper curation facility in accordance with Federal regulations. The project for the LARSS program was to research curation standards, organize the collection, catalog it, and prepare it for transfer to a facility which could provide adequate long-term curation conditions for the artifacts and documents. The first phase was to organize the artifacts, which were lying about the lab in various stages of cleaning, analysis, and conservation. Once all of the artifacts from the various excavation units and levels had been regrouped, they were cleaned and/or repackaged in archivally-stable materials. A basic catalog was prepared which will provide interested parties with a rough idea of what we have and where it can be found. Another aspect of the project was to organize the records left by the LRCHAS. Bundles of papers, photographs, and field data found in every corner and drawer of the laboratory trailer were put into order and, where appropriate, copies were made on acid-free Permabond paper for long term storage. Finally, the entire collection and most of the lab equipment was transferred into a secure, climate controlled room which will serve as an archive and study space for qualified scholars interested in exploring LaRC's rich historical heritage.

Eastman, John Arnold↗

Surface and Interface Properties of PdCr/SiC Schottky Diode Gas Sensor Annealed at 425 C

The surface and interface properties of Pd(0.9)Cr(0.1)/SiC Schottky diode gas sensors both before and after annealing are investigated using Auger Electron Spectroscopy (AES), Scanning Electron Microscopy (SEM), and Energy Dispersive Spectroscopy (EDS). At room temperature the alloy reacted with SiC and formed Pd(x)Si only in a very narrow interfacial region. After annealing for 250 hours at 425 C, the surface of the Schottky contact area has much less silicon and carbon contamination than that found on the surface of an annealed Pd/SiC structure. Palladium silicides (Pd(x)Si) formed at a broadened interface after annealing, but a significant layer of alloy film is still free of silicon and carbon. The chromium concentration with respect to palladium is quite uniform down to the deep interface region. A stable catalytic surface and a clean layer of Pd(0.9)Cr(0.1) film are likely responsible for significantly improved device sensitivity.

Chen, Liang-Yu↗

Multilayered microstructures with shape memory effects for vertical deployment

This paper presents a fabrication and characterization of multilayered microstructures with shape memory effects enabling large vertical deployment under electro-thermal actuation. Our previous research demonstrated vertical deployment of such microstructures by the effect of thermal mismatch. Development of equiatomic NiTi layers in the multilayered microstructure is investigated further for shape memory effects. Multilayered microstructures are built by sputtered NiTi layers and a lift-off process. Negative photoresist ma-N1420 enables clean lift-off of 500 nm thick NiTi layers by forming a significant undercut profile after development. The parametric study on co-sputter powers for Ti and Ni 50 Ti 50 targets suggests that 100 W RF on Ti target and 200 W DC on Ni 50 Ti 50 target can deposit Ni 49.62 Ti 50.38 layers. X-Ray Diffraction (XRD) and Atomic Force Microscopy (AFM) were used to study the crystal structures and surface topography of NiTi layers. XRD results of post-annealed Ni 49.62 Ti 50.38 layers show coexistence of austenite and martensitic phases at room temperature, suggesting that the transformation temperature of such NiTi layers should be approximate 20 °C. The surface topography of Ni 49.62 Ti 50.38 layers reveals substantial increase of surface roughness at ambient conditions after the annealing. Experimental verification of the multilayered microstructure for vertical deployment was carried out by Signatone Probe Station and Dual Scanning Electron Microscope/Focused Ion Beam (SEM/FIB) system. Finally, a vertical deployment of the two-dimensional (2D) multilayered microstructures for three-dimensional (3D) can be detected by applying a constant voltage of 0.04 V, and the expected 3D deployment displacement is enlarged from 2 μm to 10 μm by introducing the shape memory effect.

42 ENGINEERING↗

Laboratory hood design

A supply air hood is described that provides a curtain of clean air just outside of the hood surface for protection of the operator. The design consists of an overhead plenum which extends out from the hood with tapered sides extending from the plenum to the bench, a slotted baffle plate and two perforated plates with offset holes, dust filters, and a special deflector plate. The latter introduces less than 4 cubic feet flow per minute through the special perforated area so that a sweeping effort is almost always maintained at bench level. Performance tests indicate that even under adverse exhaust conditions some of the supply air may be lost to the room, but none of the air within the hood that represents contaminated flow is entrained or displayed so that it enters the work area. This hood operates with an efficiency of about 90% exhaust for supplied air.

Chamberlin, R. I.↗

Surface and Interface Study of PdCr/SiC Schottky Diode Gas Sensor Annealed at 425 C

The surface and interface properties of Pd(sub 0.9)Cr(sub 0.1/SiC Schottky diode gas sensor both before and after annealing are investigated using Auger Electron Spectroscopy (AES), Scanning Electron Microscopy (SEM), and Energy Dispersive Spectroscopy (EDS). At room temperature the alloy reacted with SiC and formed Pd(sub x)Si only in a very narrow interfacial region. After annealing for 250 hours at 425 deg. C, the surface of the Schottky contact area has much less silicon and carbon contamination than that found on the surface of an annealed Pd/SiC structure. Pd(sub x)Si formed at a broadened interface after annealing, but a significant layer of alloy film is still free of silicon and carbon. The chromium concentration with respect to palladium is quite uniform down to the deep interface region. A stable catalytic surface and a clean layer of Pd(sub 0.9)Cr(sub 0.1) film are likely responsible for significantly improved device sensitivity.

Chen, Liang-Yu↗