Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Capillary Pressure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Regulation of muscle sympathetic nerve activity after bed rest deconditioning

Cardiovascular deconditioning reduces orthostatic tolerance. To determine whether changes in autonomic function might produce this effect, we developed stimulus-response curves relating limb vascular resistance, muscle sympathetic nerve activity (MSNA), and pulmonary capillary wedge pressure (PCWP) with seven subjects before and after 18 days of -6 degrees head-down bed rest. Both lower body negative pressure (LBNP; -15 and -30 mmHg) and rapid saline infusion (15 and 30 ml/kg body wt) were used to produce a wide variation in PCWP. Orthostatic tolerance was assessed with graded LBNP to presyncope. Bed rest reduced LBNP tolerance from 23.9 +/- 2.1 to 21.2 +/- 1.5 min, respectively (means +/- SE, P = 0.02). The MSNA-PCWP relationship was unchanged after bed rest, though at any stage of the LBNP protocol PCWP was lower, and MSNA was greater. Thus bed rest deconditioning produced hypovolemia, causing a shift in operating point on the stimulus-response curve. The relationship between limb vascular resistance and MSNA was not significantly altered after bed rest. We conclude that bed rest deconditioning does not alter reflex control of MSNA, but may produce orthostatic intolerance through a combination of hypovolemia and cardiac atrophy.

Non-NASA Center↗

Cardiac atrophy after bed-rest deconditioning: a nonneural mechanism for orthostatic intolerance

BACKGROUND: The cardiovascular adaptation to bed rest leads to orthostatic intolerance, characterized by an excessive fall in stroke volume (SV) in the upright position. We hypothesized that this large fall in SV is due to a change in cardiac mechanics. METHODS AND RESULTS: We measured pulmonary capillary wedge pressure (PCWP), SV, left ventricular end-diastolic volume (LVEDV), and left ventricular mass (by echocardiography) at rest, during lower-body negative pressure, and after saline infusion before and after 2 weeks of bed rest with -6 degrees head-down tilt (n=12 subjects aged 24+/-5 years). Pressure (P)-volume (V) curves were modeled exponentially by P=ae(kV)+b and logarithmically by P=-Sln[(Vm-V)/(Vm-V0)], where V0 indicates volume at P=0, and the constants k and S were used as indices of normalized chamber stiffness. Dynamic stiffness (dP/dV) was calculated at baseline LVEDV. The slope of the line relating SV to PCWP during lower-body negative pressure characterized the steepness of the Starling curve. We also measured plasma volume (with Evans blue dye) and maximal orthostatic tolerance. Bed rest led to a reduction in plasma volume (17%), baseline PCWP (18%), SV (12%), LVEDV (16%), V0 (33%), and orthostatic tolerance (24%) (all P<.05). The slope of the SV/PCWP curve increased from 4.6+/-0.4 to 8.8+/-0.9 mL/mm Hg (P<.01) owing to a parallel leftward shift in the P-V curve. Normalized chamber stiffness was unchanged, but dP/dV was reduced by 50% at baseline LVEDV, and cardiac mass tended to be reduced by 5% (P<.10). CONCLUSIONS: Two weeks of head-down-tilt bed rest leads to a smaller, less distensible left ventricle but a shift to a more compliant portion of the P-V curve. This results in a steeper Starling relationship, which contributes to orthostatic intolerance by causing an excessive reduction in SV during orthostasis.

NASA Discipline Cardiopulmonary↗

Silicon Heat Pipe Array

Improved methods of heat dissipation are required for modern, high-power density electronic systems. As increased functionality is progressively compacted into decreasing volumes, this need will be exacerbated. High-performance chip power is predicted to increase monotonically and rapidly with time. Systems utilizing these chips are currently reliant upon decades of old cooling technology. Heat pipes offer a solution to this problem. Heat pipes are passive, self-contained, two-phase heat dissipation devices. Heat conducted into the device through a wick structure converts the working fluid into a vapor, which then releases the heat via condensation after being transported away from the heat source. Heat pipes have high thermal conductivities, are inexpensive, and have been utilized in previous space missions. However, the cylindrical geometry of commercial heat pipes is a poor fit to the planar geometries of microelectronic assemblies, the copper that commercial heat pipes are typically constructed of is a poor CTE (coefficient of thermal expansion) match to the semiconductor die utilized in these assemblies, and the functionality and reliability of heat pipes in general is strongly dependent on the orientation of the assembly with respect to the gravity vector. What is needed is a planar, semiconductor-based heat pipe array that can be used for cooling of generic MCM (multichip module) assemblies that can also function in all orientations. Such a structure would not only have applications in the cooling of space electronics, but would have commercial applications as well (e.g. cooling of microprocessors and high-power laser diodes). This technology is an improvement over existing heat pipe designs due to the finer porosity of the wick, which enhances capillary pumping pressure, resulting in greater effective thermal conductivity and performance in any orientation with respect to the gravity vector. In addition, it is constructed of silicon, and thus is better suited for the cooling of semiconductor devices.

Yee, Karl Y.↗

Initial characterization of mudstone nanoporosity with small angle neutron scattering using caprocks from carbon sequestration sites.

Geological carbon sequestration relies on the principle that CO{sub 2} injected deep into the subsurface is unable to leak to the atmosphere. Structural trapping by a relatively impermeable caprock (often mudstone such as a shale) is the main trapping mechanism that is currently relied on for the first hundreds of years. Many of the pores of the caprock are of micrometer to nanometer scale. However, the distribution, geometry and volume of porosity at these scales are poorly characterized. Differences in pore shape and size can cause variation in capillary properties and fluid transport resulting in fluid pathways with different capillary entry pressures in the same sample. Prediction of pore network properties for distinct geologic environments would result in significant advancement in our ability to model subsurface fluid flow. Specifically, prediction of fluid flow through caprocks of geologic CO{sub 2} sequestration reservoirs is a critical step in evaluating the risk of leakage to overlying aquifers. The micro- and nanoporosity was analyzed in four mudstones using small angle neutron scattering (SANS). These mudstones are caprocks of formations that are currently under study or being used for carbon sequestration projects and include the Marine Tuscaloosa Group, the Lower Tuscaloosa Group, the upper and lower shale members of the Kirtland Formation, and the Pennsylvanian Gothic shale. Total organic carbon varies from <0.3% to 4% by weight. Expandable clay contents range from 10% to {approx}40% in the Gothic shale and Kirtland Formation, respectively. Neutrons effectively scatter from interfaces between materials with differing scattering length density (i.e. minerals and pores). The intensity of scattered neutrons, I(Q), where Q is the scattering vector, gives information about the volume of pores and their arrangement in the sample. The slope of the scattering data when plotted as log I(Q) vs. log Q provides information about the fractality or geometry of the pore network. Results from this study, combined with high-resolution TEM imaging, provide insight into the differences in volume and geometry of porosity between these various mudstones.

54 ENVIRONMENTAL SCIENCES↗

Capillary toroid cavity detector for high pressure NMR

A Toroid Cavity Detector (TCD) is provided for implementing nuclear magnetic resonance (NMR) studies of chemical reactions under conditions of high pressures and temperatures. A toroid cavity contains an elongated central conductor extending within the toroid cavity. The toroid cavity and central conductor generate an RF magnetic field for NMR analysis. A flow-through capillary sample container is located within the toroid cavity adjacent to the central conductor to subject a sample material flowing through the capillary to a static magnetic field and to enable NMR spectra to be recorded of the material in the capillary under a temperature and high pressure environment.

47 OTHER INSTRUMENTATION↗

Measuring Viscosities of Gases at Atmospheric Pressure

Variant of general capillary method for measuring viscosities of unknown gases based on use of thermal mass-flowmeter section for direct measurement of pressure drops. In technique, flowmeter serves dual role, providing data for determining volume flow rates and serving as well-characterized capillary-tube section for measurement of differential pressures across it. New method simple, sensitive, and adaptable for absolute or relative viscosity measurements of low-pressure gases. Suited for very complex hydrocarbon mixtures where limitations of classical theory and compositional errors make theoretical calculations less reliable.

Singh, Jag J.↗

Development of a single-cell X-ray fluorescence flow cytometer

An X-ray fluorescence flow cytometer that can determine the total metal content of single cells has been developed. Capillary action or pressure was used to load cells into hydrophilic or hydrophobic capillaries, respectively. Once loaded, the cells were transported at a fixed vertical velocity past a focused X-ray beam. X-ray fluorescence was then used to determine the mass of metal in each cell. By making single-cell measurements, the population heterogeneity for metals in the µ M to m M concentration range on fL sample volumes can be directly measured, a measurement that is difficult using most analytical methods. This approach has been used to determine the metal composition of 936 individual bovine red blood cells (bRBC), 31 individual 3T3 mouse fibroblasts (NIH3T3) and 18 Saccharomyces cerevisiae (yeast) cells with an average measurement frequency of ~4 cells min –1 . These data show evidence for surprisingly broad metal distributions. Lastly, details of the device design, data analysis and opportunities for further sensitivity improvement are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Surface tensions of propellants

An apparatus is described for determining the surface tension of propellants by measuring the maximum bubble pressure using two capillaries of different bores. The innovation is the use of a pressure transducer coupled to a bridge supply and a strip chart recorder for registering the development of the pressure difference as the bubble is formed and released. This enables the measurements to be made under controlled atmospheres and to be remotely operated. Preliminary experiments were done on propellant-grade hydrazine and monomethylhydrazine, and on purified hydrazine, at temperatures between 275.4 and 353.2 K. Straight-line expressions and logarithmic expressions reproduce equally well the variation of surface tension with temperature. Contaminated hydrazine, pre-exposed to coupons of 6Al-4V titanium alloy for long periods, gives slightly higher values of surface tension.

Razouk, R.↗

Stabilization and Low-Frequency Oscillation of Capillary Bridges with Modulated Acoustic Radiation Pressure

In the work reported here it is demonstrated that acoustic radiation pressure may be used in simulated low gravity to produce stable bridges significantly beyond the Rayleigh limit with S as large as 3.6. The bridge (PDMS mixed with a dense liquid) has the same density as the surrounding water bath containing an ultrasonic standing wave. Modulation was first used to excite specific bridge modes. In the most recent work reported here the shape of the bridge is optically sensed and the ultrasonic drive is electronically adjusted such that the radiation stress distribution dynamically quenches the most unstable mode. This active control simulates passive stabilization suggested for low gravity. Feedback increases the mode frequency in the naturally stable region since the effective stiffness of the mode is increased.

Marston, Philip L.↗

Surfactants are Ineffective for Reducing Imbibition of Water-Based Fracturing Fluids in Deep Gas Reservoirs

Minimizing loss of injected hydraulic fracturing fluids into shale along fracture-matrix boundaries is desired because imbibed water restricts gas production and wastes valuable water resources. This problem has motivated the addition of surfactants into water-based hydraulic fracturing fluids in order to reduce the capillary driving force for imbibition. Here, we show that reduction in interfacial tension and wettability alteration has negligible ability to reduce imbibition in deep gas reservoirs. The effectiveness of altering capillary forces acting at the wetting front also depends on the injection pressure acting at the fracture-matrix boundary. The pressure at the interface between the fracture and the shale matrix is constrained between the reservoir pore pressure and formation pressure (rock fracture pressure, also known as breakdown pressure of the rock) and increases with depth to magnitudes that greatly exceed that of capillary pressures. Furthermore, the analyses presented here show that even maximum alteration of interfacial properties that result in strongly hydrophobic interactions between the fracturing fluid and reservoir rock is incapable of significantly reducing imbibition in deep reservoirs. Instead of using surfactants, this analysis points to decreases in wellbore shut-in pressures and shut-in times as practical options for reducing imbibition losses of water-based fluids.

03 NATURAL GAS↗

System automatically supplies precise analytical samples of high-pressure gases

High-pressure-reducing and flow-stabilization system delivers analytical gas samples from a gas supply. The system employs parallel capillary restrictors for pressure reduction and downstream throttling valves for flow control. It is used in conjunction with a sampling valve and minimizes alterations of the sampled gas.

Langdon, W. M.↗

Lasing in Ne-Like Argon Capillary Discharge at Low Current and the Effect of Current Prepulse

The output characteristics of saturated capillary discharge 46.9 nm Ne-like argon soft x-ray laser obtained with relatively low main discharge current of less than 20 kA, with the lowest being 9 kA. The 3 mm diameter and 200 mm long alumina capillary with Argon filling pressure range between 0.1-0.4 mbar was pumped by a discharge current with a quarter-cycle of about 40 ns. A current pulse with a typical RC shape (decay time {approx}30 {mu}s) was used as a prepulse. Measurements indicate that the laser output is affected by the timing of the application of the prepulse. This effect is most significant when the time delay between the application of the prepulse and the onset of the main current is around 2 to 4 {mu}s, and beyond these times, the effect is less significant.

74 ATOMIC AND MOLECULAR PHYSICS↗

Towards a Modern Theory of Multiphase Filtration Flow

An alternative theoretical model of joint filtration flow of immiscible incompressible fluids is presented. The model takes into account relaxation processes due to the interchange of the fluids between pores of difference sizes which is driven by capillary forces. The fluids occupy connected regions in a four-dimensional space formed by three coordinates and the pore length scale. When the fluid exchange between pores of given sizes is effected by way of successive flow through pores of all the intermediate sizes, the pressure within each region is governed by a hyperbolic equation, the role of time being played by the pore linear scale. Pressure jumps across hypersurfaces separating the regions equal corresponding values of the capillary pressure. A supplementary condition at any such hypersurface requires the speed of its displacement in the four-dimensional space to coincide with the normal velocity components of both the adjoining fluids. As a result, a principally new statement of multiphase filtration flow problems is gained with allowance for capillary relaxation in the porous space.

Buyevich, Yu A.↗

Temporal Fluctuations of Radiation of π and σ Components of a Mercury Capillary Lamp in the Presence of the Transverse Zeeman Effect

Temporal fluctuations of the intensity of radiation of the π component and of the sum of the σ{sup +} and σ components of capillary low-pressure lamps filled with mercury of natural isotopic composition are experimentally investigated in the presence of the transverse Zeeman effect. Results of investigations allow the operating regimes of such lamps used in a new experimental model of analyzer of mercury vapor concentration in atmospheric air to be optimized.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Supercritical drying of cementitious materials

Techniques to characterize the microstructure of hydrated cement require dried materials. However, the microstructure of hydrated products is significantly altered by high capillary forces during drying when using the conventional drying methods. To avoid drying stresses when preparing samples, we have employed supercritical drying (SCD) which has been used for decades to prepare aerogels that undergo no shrinkage during drying, but has rarely been used for cementitious materials. The pore solution is first replaced with isopropanol, and then with trifluoromethane (R23). The temperature and pressure are raised above the critical point, where no menisci or capillary pressure can exist; therefore, the dried samples are free of artifacts created by stresses. Images from scanning electron microscope show less compact morphology for supercritically dried samples than that dried by conventional methods, while BET surface areas of SCD samples are very close to samples dried by the isopropanol replacement method. This can be explained by the fact that isopropanol and supercritical fluid enter the micropores and block them. The nature of the chemical interactions of isopropanol and R23 with cement pastes are still not clear, but no reaction products were identified in the present study.

36 MATERIALS SCIENCE↗

Local supply of gas in vacuum: Application to a field ion source

The flow of hydrogen, helium, and nitrogen through a millimeter long and micrometer size annulus capillary from a high pressure chamber to a low pressure chamber is measured in a wide pressure range. The corresponding gas conductance is deduced. Molecular, transition, and viscous regimes are observed. The local supply of gas strongly increases with pressure in the viscous regime up to a regime controlled by capillary exit loss. Based on such a geometry, the gas supply to a field ion source with a coaxial structure is shown to be increased by more than three orders of magnitude compared to a conventional supply.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A mesoscale analysis of the Rayleigh-Plateau instability.

Capillary pinch-off results carried out with the Many-Body Dissipative Particle Dynamics (MDPD) method are compared with the two-phase continuum discretization of hydrodynamics. The MDPD method provides a mesoscale description of the liquid-gas interface -- molecules can be thought of as grouped in particles with modeled Brownian and dissipative effects. No liquid-gas interface is explicitly defined; surface properties, such as surface tension, result from the MDPD interaction parameters. In side-to-side comparisons, the behavior of the MDPD liquid is demonstrated to replicate the macroscale behavior (thin interface assumption) calculated by the Combined Level Set-Volume of Fluid (CLSVOF) method. For instance, in both the continuum and mesoscale discretizations the most unstable wavelength perturbation leads to pinch-off, whereas a smaller wavelength-to-diameter ratio, as expected, does not. The behavior of the virial pressure in MDPD will be discussed in relation to the hydrodynamic capillary pressure that results from the thin interface assumption.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗