Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Calorimeters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Calibrated particle identification for Belle II

We present several efforts aimed at improving charged particle identification at the Belle II experiment. We define an ablation test to quantify and evaluate the impact of each sub-detector on the global particle identification performance. We demonstrate that the performance of the identification scheme can be improved via a simple calibration of the sub-detector likelihoods through a set of per hypothesis, per sub-detector weights. Finally, we present preliminary results on an improved definition of the likelihoods contributed by the electromagnetic calorimeter. A set of multiclass boosted decision trees is trained to exploit the shape of energy depositions of different particle species. In simulated $B\bar{B}$ events, the pion-to-electron and muon fake rates are reduced by 55% and 31% respectively at low-medium momentum.

Hohmann, Marcel [Univ. of Melbourne, Parkville, VI↗

Detector and Physics Performance at a Muon Collider

A muon collider represents the ideal machine to reach very high center-of-mass energies and luminosities by colliding elementary particles. This is the result of the low level of beamstrahlung and synchrotron radiation compared to linear or circular electron-positron colliders. In contrast with other lepton machines, the design of a detector for a multi-TeV muon collider requires detailed knowledge of the interaction region due to the significant backgrounds created by muon beam decays in the collider ring. The physics reach can be properly evaluated only when the detector performance in such an environment is determined. In this work, the backgrounds generated by muon beams of 750 GeV are characterized and the performance of the tracking system and the calorimeter detector is illustrated. Solutions to minimize the effect of the beam-induced backgrounds are discussed and applied to obtain track and jet reconstruction performance. The μ + μ – → $Hν\bar{ν} → b\bar{b} ν\bar{ν}$ process is fully simulated and reconstructed to demonstrate that physics measurements are possible in this harsh environment. The measurement precision for the Higgs boson coupling to $b\bar{b}$ is evaluated for $\sqrt{s}$=1.5, 3, and 10 TeV and compared to other proposed machines.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

DCTRGAN: improving the precision of generative models with reweighting

Significant advances in deep learning have led to more widely used and precise neural network-based generative models such as Generative Adversarial Networks (Gans). We introduce a post-hoc correction to deep generative models to further improve their fidelity, based on the Deep neural networks using the Classification for Tuning and Reweighting (Dctr) protocol. The correction takes the form of a reweighting function that can be applied to generated examples when making predictions from the simulation. We illustrate this approach using Gans trained on standard multimodal probability densities as well as calorimeter simulations from high energy physics. We show that the weighted Gan examples significantly improve the accuracy of the generated samples without a large loss in statistical power. This approach could be applied to any generative model and is a promising refinement method for high energy physics applications and beyond.

47 OTHER INSTRUMENTATION↗

200 mm sensor development using bonded wafers

Sensors fabricated from high resistivity, float zone, silicon material have been the basis of vertex detectors and trackers for the last 30 years. The areas of these devices have increased from a few square cm to > 200m 2 for the existing CMS tracker. High Luminosity Large Hadron Collider (HL-LHC), CMS and ATLAS tracker upgrades will each require more than 200 m 2 of silicon and the CMS High Granularity Calorimeter (HGCAL) will require more than 600 m 2 . The cost and complexity of assembly of these devices is related to the area of each module, which in turn is set by the size of the silicon sensors. In addition to large area, the devices must be radiation hard, which requires the use of sensors thinned to 200 microns or less. The combination of wafer thinning and large wafer diameter is a significant technical challenge, and is the subject of this work. In this paper we describe work on development of thin sensors on 200 mm wafers using wafer bonding technology. Results of development runs with float zone, Silicon-on-Insulator and Silicon-Silicon bonded wafer technologies are reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutral pion reconstruction using machine learning in the experiment at 〈E ν〉 6 GeV

This paper presents a novel neutral-pion reconstruction that takes advantage of the machine learning technique of semantic segmentation using MINERvA data collected between 2013–2017, with an average neutrino energy of 6 GeV. Semantic segmentation improves the purity of neutral pion reconstruction from two γs from 70.7 ± 0.9% to 89.3 ± 0.7% and improves the efficiency of the reconstruction by approximately 40%. We demonstrate our method in a charged current neutral pion production analysis where a single neutral pion is reconstructed. This technique is applicable to modern tracking calorimeters, such as the new generation of liquid-argon time projection chambers, exposed to neutrino beams with 〈E ν〉 between 1–10 GeV. In such experiments it can facilitate the identification of ionization hits which are associated with electromagnetic showers, thereby enabling improved reconstruction of charged-current νe events arising from νμ → νe appearance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Silicon-Photomultipliers for a Cosmic Muon Veto detector

A Cosmic Muon Veto (CMV) detector using extruded scintillators is being designed around the mini-Iron Calorimeter detector at the transit campus of the India-based Neutrino Observatory, Madurai for measuring its efficiency at shallow depth underground experiments. The scintillation signal is transmitted through a Wavelength Shifting (WLS) fibre and readout by Hamamatsu Silicon-Photomultipliers (SiPMs). A Light Emitting Diode (LED) system is included on the front-end readout for in-situ calibration of the gain of each SiPM. A characterization system was developed for the measurement of gain and choice of the overvoltage (V ov ) of SiPMs using the LED as well as a cosmic muon telescope. The V ov is obtained by studying the noise rate, the gain of the SiPM, and the muon detection efficiency. In case of any malfunction of the LED system during the operation, the SiPM can also be calibrated with the noise data as well as using radioactive sources. Furthermore, this paper describes the basic characteristics of the SiPM and the comparison of the calibration results using all three methods, as well as the V ov of the SiPMs and muon selection criteria for the veto detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The straw tracking detector for the Fermilab Muon g-2 Experiment

The Muon g-2 Experiment at Fermilab uses a gaseous straw tracking detector to make detailed measurements of the stored muon beam profile, which are essential for the experiment to achieve its uncertainty goals. Positrons from muon decays spiral inward and pass through the tracking detector before striking an electromagnetic calorimeter. The tracking detector is therefore located inside the vacuum chamber in a region where the magnetic field is large and non-uniform. As such, the tracking detector must have a low leak rate to maintain a high-quality vacuum, must be non-magnetic so as not to perturb the magnetic field and, to minimize energy loss, must have a low radiation length. The performance of the tracking detector has met or surpassed the design requirements, with adequate electronic noise levels, an average straw hit resolution of (110 ± 20) μm, a detection efficiency of 97% or higher, and no performance degradation or signs of aging. The tracking detector's measurements result in an otherwise unachievable understanding of the muon's beam motion, particularly at early times in the experiment's measurement period when there are a significantly greater number of muons decaying. This is vital to the statistical power of the experiment, as well as facilitating the precise extraction of several systematic corrections and uncertainties. This paper describes the design, construction, testing, commissioning, and performance of the tracking detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prototype hardware design and testing of the global common module for the global trigger subsystem of the ATLAS phase-II upgrade

We report the High-Luminosity Large Hadron Collider (HL-LHC) will deliver more than ten times the integrated luminosity of the previous runs combined. Meeting its stricter throughput requirements poses new challenges to the Trigger and Data Acquisition (TDAQ) systems of the LHC experiments. Introduced in the framework of the ATLAS experiment’s HL upgrade, the Global Trigger (GT) is a new subsystem which will perform offline-like algorithms on full-granularity calorimeter data. The implementation of the GT’s functionality is firmware-focused and is composed of three layers: multiplexing (or data aggregating), global event processing, and demultiplexing interface to the central trigger processor. Each layer will be composed of several, similar nodes, hosted on replicas of identical hardware, the Global Common Module (GCM), an ATCA front board which is designed to be adopted throughout the entire GT subsystem. This article proceeds from the TWEPP 2021 conference and presents the GCM hardware design, performed in 2020, and focuses on some key results of its extensive testing performed in 2021.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Centrality determination in heavy-ion collisions with the LHCb detector

The centrality of heavy-ion collisions is directly related to the created medium in these interactions. A procedure to determine the centrality of collisions with the LHCb detector is implemented for lead-lead collisions at √ s NN = 5 TeV and lead-neon fixed-target collisions at √ s NN = 69 GeV. The energy deposits in the electromagnetic calorimeter are used to determine and define the centrality classes. The correspondence between the number of participants and the centrality for the lead-lead collisions is in good agreement with the correspondence found in other experiments, and the centrality measurements for the lead-neon collisions presented here are performed for the first time in fixed-target collisions at the LHC.

47 OTHER INSTRUMENTATION↗

Muon track reconstruction in a segmented bolometric array using multi-objective optimization

Recent advances in segmented solid-state detector arrays for rare-event searches have allowed the technology to approach the ton-scale in detector mass and the scale of meters in size. Often focused around searches for neutrinoless double-beta decay or direct dark matter detection, such experiments also have the capability to search for exotic particles that leave track-like signatures across their volume. However, the segmented nature of such detector arrays often sets the spatial resolution and makes the problem of reconstructing track-like paths non-trivial. Here, in this paper, we present an algorithm that improves reconstruction of track-like events in segmented detectors using multi-objective optimization — a computational technique that optimizes more than one cost function at a time without specifying a quantitative weighting between them. Such a technique allows the reconstruction of tracks through a detector and the determination of path-lengths through individual elements. When combined with the reconstructed energy depositions in each element this allows for a calculation of the stopping power of track-like particles and opens the door to searches for particles with abnormal stopping power like monopoles or lightly-ionizing particles (LIPs). Results are presented which evaluate the precision of the reconstruction tools as they currently stand against Monte Carlo generated data. The algorithm is presented in the context of the CUORE experiment, but has applications to other segmented calorimeter detectors.

47 OTHER INSTRUMENTATION↗

Hardware design and testing of the generic rear transition module for the global trigger subsystem of ATLAS Phase-II Upgrade

Abstract In the framework of the ATLAS experiment’s Phase-II Upgrade at the High-Luminosity Large Hadron Collider (HL-LHC), new and improved trigger hardware and algorithms will be implemented onto a single-level, 10 μs-latency architecture. The Global Trigger is a new subsystem which will bring event-filter capabilities by performing offline-like algorithms on full-granularity calorimeter data. The implementation of the functionality is firmware-focused and composed of several processing nodes, which are hosted on identical hardware, made up of an Advanced Telecommunications Computing Architecture (ATCA) front board, called Global Common Module (GCM), and a rear transition module (RTM), called Generic RTM (GRM). The GRM, which was developed to mitigate the risks deriving from the complex design and power management of the GCM, features an advanced Xilinx Versal Prime system-on-chip and can handle communication with the GCM and Front-End Link eXchange (FELIX) subsystem and trigger processors through 124 25.8 Gb/s transceiver links, for readout and control. Additionally, the GRM mounts a Low-Power GigaBit Transceiver (lpGBT) chip which enables emulation of the detector front-ends for integration tests. This paper presents the GRM hardware design and its testing.

Instruments & Instrumentation↗

Thin film charged particle detectors

Silicon tracking detectors have grown to cover larger surface areas up to hundreds of square meters, and are even taking over other sub-detectors, such as calorimeters. However, further improvements in tracking detector performance are more likely to arise from the ability to make a low mass detector comprised of a high ratio of active sensor to inactive materials, where dead materials include electrical services, cooling, mechanical supports, etc. In addition, the cost and time to build these detectors is currently large. Therefore, advancements in the fundamental technology of tracking detectors may need to look at a more transformative approach that enables extremely large area coverage with minimal dead material and is easier and faster to build. The advancement of thin film fabrication techniques has the potential to revolutionize the next-to-next generation of particle detector experiments. Some thin film deposition techniques have already been developed and widely used in the industry to make LED screens for TVs and monitors. If large area thin film detectors on the order of several square meters can be fabricated with similar performance as current silicon technologies, they could be used in future particle physics experiments. This paper aims to review the key fundamental performance criteria of existing silicon detectors and past research to use thin films and other semi-conductor materials as particle detectors in order to explore the important considerations and challenges to pursue thin film detectors.

Solid state detectors↗

ALICE luminosity determination for Pb–Pb collisions at $\sqrt{s_{NN}}$ = 5.02 TeV

Luminosity determination within the ALICE experiment is based on the measurement, in van der Meer scans, of the cross sections for visible processes involving one or more detectors (visible cross sections). In 2015 and 2018, the Large Hadron Collider provided Pb–Pb collisions at a centre-of-mass energy per nucleon pair of $\sqrt{s_{NN}}$ = 5.02 TeV. Two visible cross sections, associated with particle detection in the Zero Degree Calorimeter (ZDC) and in the V0 detector, were measured in a van der Meer scan. This article describes the experimental set-up and the analysis procedure, and presents the measurement results. The analysis involves a comprehensive study of beam-related effects and an improved fitting procedure, compared to previous ALICE studies, for the extraction of the visible cross section. The resulting uncertainty of both the ZDC-based and the V0-based luminosity measurement for the full sample is 2.5%. The inelastic cross section for hadronic interactions in Pb–Pb collisions at $\sqrt{s_{NN}}$ = 5.02 TeV, obtained by efficiency correction of the V0-based visible cross section, was measured to be 7.67 ± 0.25 b, in agreement with predictions using the Glauber model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First test results of the HGCAL concentrator ASICs: ECON-T and ECON-D

With over 6 million channels, the High Granularity Calorimeter for the CMS HL-LHC upgrade presents a unique data transmission challenge. The ECON ASICs provide a critical stage of on-detector data compression and selection for the trigger path (ECON-T) and data acquisition path (ECON-D) of the HGCAL. The ASICs, fabricated in 65 nm CMOS, are radiation tolerant up to 200 Mrad and require low power consumption: < 2.5 mW/sensor-channel per chip. Here, we report on the first functionality and radiation tests for the ECON-D-P1 full-functionality prototype. We present a comparison of single event effect (SEE) cross sections measured for different methods of triple modular redundancy using test results from the ECON-T-P1 full-functionality prototype.

47 OTHER INSTRUMENTATION↗

Characterization of the ATLAS Liquid Argon Front-End ASIC ALFE2 for the HL-LHC upgrade

In this study, ALFE2 is an ATLAS Liquid Argon Calorimeter (LAr) Front-End ASIC designed for the HL-LHC upgrade. ALFE2 comprises four channels of pre-amplifiers and CR-(RC) 2 shapers with adjustable input impedance. ALFE2 features two separate gain outputs to provide 16-bit dynamic-range coverage and an optimum resolution. ALFE2 is characterized using a Front-End Test Board (FETB) based on a Zynq UltraScale+ MPSoC and two octal-channel 16-bit high-speed ADCs. The test results indicate that ALFE2 fulfills or greatly exceeds all specifications on gain, noise, linearity, uniformity, and radiation tolerance.

47 OTHER INSTRUMENTATION↗

Beam-induced backgrounds measured in the ATLAS detector during local gas injection into the LHC beam vacuum

Inelastic beam-gas collisions at the Large Hadron Collider (LHC), within a few hundred metres of the ATLAS experiment, are known to give the dominant contribution to beam backgrounds. These are monitored by ATLAS with a dedicated Beam Conditions Monitor (BCM) and with the rate of fake jets in the calorimeters. These two methods are complementary since the BCM probes backgrounds just around the beam pipe while fake jets are observed at radii of up to several metres. In order to quantify the correlation between the residual gas density in the LHC beam vacuum and the experimental backgrounds recorded by ATLAS, several dedicated tests were performed during LHC Run 2. Local pressure bumps, with a gas density several orders of magnitude higher than during normal operation, were introduced at different locations. The changes of beam-related backgrounds, seen in ATLAS, are correlated with the local pressure variation. In addition the rates of beam-gas events are estimated from the pressure measurements and pressure bump profiles obtained from calculations. Using these rates, the efficiency of the ATLAS beam background monitors to detect beam-gas events is derived as a function of distance from the interaction point. These efficiencies and characteristic distributions of fake jets from the beam backgrounds are found to be in good agreement with results of beam-gas simulations performed with theFluka Monte Carlo programme.

43 PARTICLE ACCELERATORS↗

Advances in the Large Area Picosecond Photo-Detector (LAPPD TM ): 8" × 8" MCP-PMT with Capacitively Coupled Readout

Abstract We present advances made in the Large Area Picosecond Photodetector (LAPPD), an 8" × 8" microchannel plate photomultiplier tube (MCP-PMT), since pilot production was initiated at Incom, Inc. in 2018. The Gen-I LAPPD utilizes a stripline anode for direct charge readout. The novel Gen-II LAPPD employs an internal resistive thin-film which capacitively couples to a customizable external signal readout board, streamlining production and increasing customer flexibility. The Gen-II LAPPD, with an active area of 373 cm 2 , is capable of high single photoelectron (PE) gain of ∼10 7 , low dark rates (∼1 kHz/cm 2 ), single PE (SPE) timing resolution of ∼65 ps, and 𝒪(mm) position resolution. Coupled with a UV-grade fused silica window, the LAPPD features a high quantum efficiency (QE) bialkali photocathode of >30% at 365 nm with spectral response down to ∼165 nm. The LAPPD is an excellent candidate for electromagnetic calorimeter (ECAL) timing layers, photon-based neutrino detectors, high energy collider experiments, medical imaging systems, and nuclear non-proliferation applications.

Instruments & Instrumentation↗

A method to observe field-region oxide charge and inter-electrode isolation from CV-characteristics of n-on-p devices

Abstract N-on-psilicon sensors will be utilized in the Compact Muon Solenoid (CMS) detector's tracker and High Granularity Calorimeter (HGCAL) in the High Luminosity upgrade of the Large Hadron Collider (HL-LHC). Among their several advantages in terms of radiation hardness over the traditionalp-on-nsensors in the extreme radiation environment of the HL-LHC are electron collection instead of holes and overlapping maxima of weighting and electric fields at the charge-collecting electrodes. The disadvantage of the multi-channel SiO 2 -passivatedn-on-psensors is the generation of an inversion layer under the Si/SiO 2 -interface by a positive interface-oxide-charge (N ox ) that at high densities can compromise the position resolution by creating a conduction channel between the electrodes. This issue is typically addressed by including additional isolnts (p-stp,p-spray) between n + -electrodes. Focusing on the guard-ring regions ofn-on-psensors where no isolation implants are applied between the electrodes, a capacitance-voltage (CV) characterization study of both 6-inch wafer test diodes and 8-inch HGCAL prototype and pre-series sensors showed a distinct threshold voltage (V th,iso ) in theCV-characteristics of a biased n + -electrode when its enclosing guard-ring was left floating. When reproduced by simulations, the measuredV th,iso was found to contain information on the field-regionN ox and indicate the threshold where the two electrodes become electrically isolated by the influence of the reverse bias voltage. Together with previous studies on the inter-electrode isolation of irradiatedn-on-psensors, the results indicate that position sensitiven-on-psensors without isolation implants may be feasible in future HEP experiments.

Instruments & Instrumentation↗