Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CRYOGENIC FLUID”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Liquid Acquisition Device Testing with Sub-Cooled Liquid Oxygen

When transferring propellant in space, it is most efficient to transfer single phase liquid from a propellant tank to an engine. In earth s gravity field or under acceleration, propellant transfer is fairly simple. However, in low gravity, withdrawing single-phase fluid becomes a challenge. A variety of propellant management devices (PMD) are used to ensure single-phase flow. One type of PMD, a liquid acquisition device (LAD) takes advantage of capillary flow and surface tension to acquire liquid. Previous experimental test programs conducted at NASA have collected LAD data for a number of cryogenic fluids, including: liquid nitrogen (LN2), liquid oxygen (LOX), liquid hydrogen (LH2), and liquid methane (LCH4). The present work reports on additional testing with sub-cooled LOX as part of NASA s continuing cryogenic LAD development program. Test results extend the range of LOX fluid conditions examined, and provide insight into factors affecting predicting LAD bubble point pressures.

Jurns, John M.↗

Composite-Material Tanks with Chemically Resistant Liners

Lightweight composite-material tanks with chemically resistant liners have been developed for storage of chemically reactive and/or unstable fluids . especially hydrogen peroxide. These tanks are similar, in some respects, to the ones described in gLightweight Composite-Material Tanks for Cryogenic Liquids h (MFS-31379), NASA Tech Briefs, Vol. 25, No. 1 (January, 2001), page 58; however, the present tanks are fabricated by a different procedure and they do not incorporate insulation that would be needed to prevent boil-off of cryogenic fluids. The manufacture of a tank of this type begins with the fabrication of a reusable multisegmented aluminum mandrel in the shape and size of the desired interior volume. One or more segments of the mandrel can be aluminum bosses that will be incorporated into the tank as end fittings. The mandrel is coated with a mold-release material. The mandrel is then heated to a temperature of about 400 F (approximately equal to 200 C) and coated with a thermoplastic liner material to the desired thickness [typically approxiamtely equal to 15 mils (approximately equal to 0.38 mm)] by thermal spraying. In the thermal-spraying process, the liner material in powder form is sprayed and heated to the melting temperature by a propane torch and the molten particles land on the mandrel. The sprayed liner and mandrel are allowed to cool, then the outer surface of the liner is chemically and/or mechanically etched to enhance bonding of a composite overwrap. The etched liner is wrapped with multiple layers of an epoxy resin reinforced with graphite fibers; the wrapping can be done either by manual application of epoxy-impregnated graphite cloth or by winding of epoxy-impregnated filaments. The entire assembly is heated in an autoclave to cure the epoxy. After the curing process, the multisegmented mandrel is disassembled and removed from inside, leaving the finished tank. If the tank is to be used for storing hydrogen peroxide, then the liner material should be fluorinated ethylene/propylene (FEP), and one or more FEP O ring(s) should be used in the aluminum end fitting(s). This choice of materials is dictated by experimental observations that pure aluminum and FEP are the only materials suitable for long-term storage of hydrogen peroxide and that other materials tend to catalyze the decomposition of hydrogen peroxide to oxygen and water. Other thermoplastic liner materials that are suitable for some applications include nylon 6 and polyethylene. The processing temperatures for nylon 6 are lower than those for FEP. Nylon 6 is compatible with propane, natural gas, and other petroleum-based fuels. Polyethylene is compatible with petroleum- based products and can be used for short-term storage of hydrogen peroxide.

DeLay, Thomas K.↗

Systems and operations - Living with complexity and growth

Since the space station concept currently being developed by NASA calls for system updates and additions over a period of at least ten years following launch, attention must be given to the interfaces between station elements. Efforts have begun to develop generic fault detection, isolation, and correction techniques that could simplify on-orbit operations, maintenance and repair. An integrated hydrogen-oxygen system has been identified as the feature promising the greatest reduction in resupply costs. Scavenging excess fuel from the Space Shuttle's internal and external tanks, and using leftover Shuttle payload for fluid tankage, could supply hydrogen and oxygen for consumption in the form of propellants, fuel cell electricity, and life support gases. Advancements in cryogenic fluid management and storage technology are the keys to the design of this integrated system. Attention is given to the Interactive Design and Evaluation of Advanced Spacecraft computer-aided design and analysis system, which allows system engineers to study the integration problems presented by 40 technical modules.

Hook, W. R.↗

Using Composite Materials in a Cryogenic Pump

Several modifications have been made to the design and operation of an extended-shaft cryogenic pump to increase the efficiency of pumping. In general, the efficiency of pumping a cryogenic fluid is limited by thermal losses which is itself caused by pump inefficiency and leakage of heat through the pump structure. A typical cryogenic pump includes a drive shaft and two main concentric static components (an outer pressure containment tube and an intermediate static support tube) made from stainless steel. The modifications made include replacement of the stainless-steel drive shaft and the concentric static stainless-steel components with components made of a glass/epoxy composite. The leakage of heat is thus reduced because the thermal conductivity of the composite is an order of magnitude below that of stainless steel. Taking advantage of the margin afforded by the decrease in thermal conductivity, the drive shaft could be shortened to increase its effective stiffness, thereby increasing the rotordynamic critical speeds, thereby further making it possible to operate the pump at a higher speed to increase pumping efficiency. During the modification effort, an analysis revealed that substitution of the shorter glass/epoxy shaft for the longer stainless-steel shaft was not, by itself, sufficient to satisfy the rotordynamic requirements at the desired increased speed. Hence, it became necessary to increase the stiffness of the composite shaft. This stiffening was accomplished by means of a carbon-fiber-composite overwrap along most of the length of the shaft. Concomitantly with the modifications described thus far, it was necessary to provide for joining the composite-material components with metallic components required by different aspects of the pump design. An adhesive material formulated specially to bond the composite and metal components was chosen as a means to satisfy these requirements.

Batton, William D.↗

Structural Heat Intercept, Insulation and Vibration Evaluation Rig (SHIIVER)

The Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER) is a large scale cryogenic fluid management (CFM) test bed designed to scale CFM technologies for inclusion on large, in-space stages. A part of the evolvable Cryogenics (eCryo) project, SHIIVER is a technology development task that is supportive of future exploration propulsion needs. Technologies developed under the eCryo Project will play a critical role in enabling increasingly longer duration in-space missions beyond Low Earth Orbit (LEO).

Vapor cooling↗

Updated Human Mars Ascent Vehicle Concept in Support of NASA’s Strategic Analysis Cycle 2021

The NASA Artemis program has brought significant change to the agency’s human exploration strategy over the last several years. The human exploration of Mars remains an ultimate objective of the overall human exploration strategy. However, how the agency intends to execute initial human exploration of Mars has shifted to better align with current policy. These changes find their way into the design of key architecture elements, such as the Mars Ascent Vehicle (MAV). Of the numerous changes in the conceptual human Mars architecture, two in particular have had significant impact on the design of the human MAV: the desire for minimal surface infrastructure for initial human Mars missions, and technology investment timelines in support of initial human missions to Mars. The first leads to a surface mission architecture targeting a 30-day surface duration with two crewmembers. The second drives out in-situ resource utilization (ISRU) from the initial sortie. As a result, the reference MAV design for initial human Mars missions in the Human Exploration and Operations Mission Directorate’s Strategic Analysis Cycle 2021 (SAC21) is based around supporting the return of 2 crew from the surface of Mars, without surface ISRU. This has led to several design changes since 2019, when details of a reference human MAV were last published. The MAV concept for SAC21 consists of a two-stage vehicle capable of supporting two crew for 84 hours. This duration is derived from a baseline ascent trajectory targeting an apoapsis rendezvous with the habitation element in a nominal 5-sol Mars aggregation orbit. With the goal of minimizing technology investments for the initial surface sortie removing ISRU from the trade space, the MAV must now be landed either fully loaded with propellant, or with some portion of the propellant off-loaded. Landing a partially-fueled MAV will require additional surface assets to perform robotic propellant transfer on the surface of Mars from a pre-emplaced propellant depot. Furthermore, cryogenic fluid management and storage for extended duration with no losses represents additional technology investment that would have to be made to support cryogenic-based propellant concepts that have been the baseline in past architectures. As a result, the SAC21 architecture utilizes a storable propellant-based MAV propulsion system to minimize these potential technology investments incurred by cryogenic-based propulsion systems. Recent efforts also focused on evaluating the sensitivity of key design parameters, such as landing site latitude, elevation, and local atmospheric conditions. All play a large role in determining the predicted propellant requirements of the MAV. Understanding their potential impacts is important because of the rippling effects of changes to the MAV design on other architecture elements, such as entry, descent, landing, and transportation systems. Results indicate up to +2% to -4% wet mass variation due to landing site latitude, with higher latitudes greater than 70 degrees North resulting in greater than 6% wet mass increases. The MAV saw reduced impact due to atmospheric design parameters, which only accounting for -0.6% to +0.4% wet mass variation.

Douglas J. Trent↗

Numerical Analysis of Cavitation-Induced Two-Phase Fluid Transients in Cryogenic Feedlines Using Finite Volume Procedure

This article presents a numerical investigation of the cavitation induced fluid transient in cryogenic feedline due to sudden closure of the valve A one dimensional numerical model based on finite volume procedure consisting of nodes and branches using Generalized Fluid System Simulation Program ( has been employed for the prediction of pressure variations The unsteady friction formulation accurately determines wall shear stress, and a homogeneous mixture model is used for two phase flow modeling Numerical results obtained with the present formulation are compared with experimental results and Method of Characteristic ( based results It is observed that low residual in flow variable calculation improves the solution providing numerically stable results GFSSP is able to reproduce the fluid transient peak due to vapor collapse Subsequently, it can retain the shape of pressure wave for two phase fluid transients, but it is dampening faster compared to experiments Further investigation is required with set of experiments to validate the present numerical approach for different experimental data.

Fluid Transient↗

Aluminum to Stainless-Steel Joints for Cryogenic Applications

Aluminum to stainless-steel joints are necessary for cryogenic applications such as cryogenic fluid management and combustion devices. Supplemental development in this area was required for a test program at NASA Marshall Space Flight Center (MSFC) of an Al6061-RAM2 additively manufacturing liquid rocket nozzle. The test program identified a risk for installing stainless-steel fluid fittings to aluminum manifolds. To address this, a literature search was completed for various joint designs, and three designs were down selected to be cryogenic pressure cycle tested at MSFC. The test pieces were subsequently burst tested with ambient temperature water. This paper provides an overview of the literature review, down selected designs, test setup, test results, and fractography. The test results informed design decisions for the Al6061-RAM2 nozzle, and the recommended design proved to be a robust option with no notable issues identified during hot-fire testing.

Tessa M. Fedotowsky↗

Design review of fluid film bearing testers

The designs of three existing testers (Hybrid Bearing Tester, OTV Bearing Tester, and Long Life Bearing Tester) owned by NASA were reviewed for their capability to serve as a multi-purpose cryogenic fluid film bearing tester. The primary tester function is the validation of analytical predictions for fluid film bearing steady state and dynamic performance. Evaluation criteria were established for test bearing configurations, test fluids, instrumentation, and test objectives. Each tester was evaluated with respect to these criteria. A determination was made of design improvements which would allow the testers to meet the stated criteria. The cost and time required to make the design changes were estimated. A recommendation based on the results of this study was made to proceed with the Hybrid Bearing Tester.

Scharrer, Joseph K.↗

Liquid Nitrogen Testing of an Integrated Reaction Control System

Integrated Reaction Control Systems (IRCS) are considered an enabling technology for future human exploration of the solar system. An IRCS uses the same fuel and oxidizer as the main propulsion system, allowing for increased performance and simplified cryogenic fluid management operations. The IRCS team at Marshall Spaceflight Center is currently evaluating an IRCS system that uses a combination of electric pumps and pressure-regulation devices to provide a constant flow of conditioned propellant to a thruster bank during operation. In contrast to accumulator and gasifier designs, the recirculation loop design is less massive and can provide large, sustained flowrates to the thruster inlet. In the summer 2021 test series presented herein, the feasibility of this concept was evaluated using liquid nitrogen as a simulant for liquid oxygen. The goals of this test series were to demonstrate the ability of the pump and pressure regulator to maintain adequate thruster inlet conditions during transient operation, and to demonstrate the ability for the system to operate in an “idle mode” that maintains system chill between activations. During test operations, the back-pressure regulator responded more slowly than the opening/closing of valves in the thruster simulant, but it was still able to attenuate the pressure fluctuation at the pump discharge and ensure a stable flowrate through the pump. Similarly, the pump was able to be run far below its nominal operating point and successfully flow sufficient fluid to maintain chill conditions.

integrated RCS↗

Liquid Nitrogen Testing of an Integrated Reaction Control System

Integrated Reaction Control Systems (IRCS) are considered an enabling technology for future human exploration of the solar system. An IRCS uses the same fuel and oxidizer as the main propulsion system, allowing for increased performance and simplified cryogenic fluid management operations. The IRCS team at Marshall Spaceflight Center is currently evaluating an IRCS system that uses a combination of electric pumps and pressure-regulation devices to provide a constant flow of conditioned propellant to a thruster bank during operation. In contrast to accumulator and gasifier designs, the recirculation loop design is less massive and can provide large, sustained flowrates to the thruster inlet. In the summer 2021 test series presented herein, the feasibility of this concept was evaluated using liquid nitrogen as a simulant for liquid oxygen. The goals of this test series were to demonstrate the ability of the pump and pressure regulator to maintain adequate thruster inlet conditions during transient operation, and to demonstrate the ability for the system to operate in an “idle mode” that maintains system chill between activations. During test operations, the back-pressure regulator responded more slowly than the opening/closing of valves in the thruster simulant, but it was still able to attenuate the pressure fluctuation at the pump discharge and ensure a stable flowrate through the pump. Similarly, the pump was able to be run far below its nominal operating point and successfully flow sufficient fluid to maintain chill conditions.

integrated RCS↗

Gravity jitter induced slosh waves in liquid propellant and disturbances of fluid stresses on spacecraft

The paper investigates the dynamical behavior of fluids, in particular the effect of surface tension on partially filled rotating fluids (cryogenic liquid helium and helium vapor) in a full-scale Gravity Probe-B spacecraft propellant dewar tank imposed by various frequencies of gravity jitters. Fluid stress distribution caused by the excitation of slosh waves and their associated large amplitude disturbances on the liquid-vapor interface and exerted on the outer and inner walls of a rotating dewar container are also examined. It is shown that fluid stress distributions near the outer and inner walls of the rotating dewar are closely related to the characteristics of slosh waves excited in the liquid-vapor interface in the rotating dewar tank. This can be of utility in managing spacecraft dynamic control leading to control of spacecraft imbalance caused by the uneven fluid stress distribution due to slosh wave excitations at the interface between liquid and vapor propellants.

Hung, R. J.↗

Apparatus and method for jet noise suppression

A method and apparatus for jet noise suppression through control of the static pressure of the jet and control of the rate of entrainment of ambient fluid into the jet downstream of the exhaust nozzle is disclosed. The momentum flux over an extended region of the jet is regulated, affecting Reynolds stresses in the jet and the spreading angle of the jet. Static pressure is controlled through a long hollow, porous nozzle plug centerbody which may be selectively vented to ambient conditions, connected to a vacuum source, or supplied with fluids of various densities for injection into the stream. Sound in the jet may be channeled along the nozzle plug centerbody by injecting coolant such as a cryogenic fluid throughout the center-body into the jet.

Maestrello, L.↗

NASA Cryogenic Propellant Systems Technology Development and Potential Opportunities for Discussion

Members of the eCryo Team are traveling to France to meet with CNES (Centre National d'Etudes Spatiales) on the benchmarking of CFM (Cryogenic Fluids Management) analytical models the week of January 26th, 2015. Mike Meyer is representing the Agency and eCryo Project and will conduct a conversation to explore future work. This slide package (28 charts and 3 movies) requires approval via a 1676. ISS data in this chart set has been copied from public websites.

Cryogenics CPST eCryo Propellent Transfer fluid ma↗

Propagation of Cryogenic Thermal Fractures from Unconfined PMMA Boreholes

In cryogenic fracturing, a rock surface exposed to cryogenic fluids undergoes a large thermal gradient, and the resultant local tensile stress overcomes rock strength and initiates fractures. This study investigates the development of cracks generated from the cryogenic treatment of a borehole under no external confining stress on specimens. The experiments were performed on transparent PMMA specimens to observe fracture proliferation around boreholes. Liquid nitrogen was flowed through the boreholes to cool the borehole surface. The results show that initial fracture growth is characterized by abrupt starts and stops, and as the fracture propagates outward, the growth appears more continuous. In an early stage, horizontal/radial fractures and vertical fractures are the defining patterns. Horizontal fractures tend to be separated by a specific exclusion distance (i.e., spacing between cracks). While distinct horizontal/vertical fractures and exclusion distance manifest themselves at an early stage, fractures resulting from fracture interactions and curvatures can develop into complex shapes at later stages. Cryogenic thermal loading induces distinctively curved fractures. The tendency of curvature may prevent greater penetration. An increase in the borehole pressure during liquid nitrogen flow, however, can lessen fracture tortuosity and facilitate radial propagation. A high flow pressure and rate are also advantageous in that they accelerate cooling and fracture propagation.

42 ENGINEERING↗

Turbopump thermodynamic cooling

System for cooling turbopumps used in cryogenic fluid storage facilities is described. Technique uses thermodynamic propellant vent to intercept pump heat at desired conditions. Cooling system uses hydrogen from outside source or residual hydrogen from cryogenic storage tank.

Patten, T. C.↗

Cryogenic wind tunnels. III

Specific problems pertaining to cryogenic wind tunnels, including LN(2) injection, GN(2) exhaust, thermal insulation, and automatic control are discussed. Thermal and other physical properties of materials employed in these tunnels, properties of cryogenic fluids, storage and transfer of liquid nitrogen, strength and toughness of metals and nonmetals at low temperatures, and material procurement and qualify control are considered. Safety concerns with cryogenic tunnels are covered, and models for cryogenic wind tunnels are presented, along with descriptions of major cryogenic wind-tunnel facilities the United States, Europe, and Japan. Problems common to wind tunnels, such as low Reynolds number, wall and support interference, and flow unsteadiness are outlined.

Kilgore, Robert A.↗

Universal Two-Phase Convection Heat Transfer Correlations for Cryogenic Pipe Chilldown

This paper presents a set of universal two-phase convection heat transfer correlations for modeling boiling heat transfer during pipe chilldown fit over the widest available range of cryogenic fluids and thermodynamic conditions. The correlations improve upon prior correlations that were developed separately for liquid nitrogen (LN2) and liquid hydrogen (LH2) pipe quenching datasets. The new correlations include equations to calculate the single-phase vapor heat transfer, film boiling heat transfer, transition boiling heat transfer, nucleate boiling heat transfer, single-phase liquid heat transfer, bulk vapor temperature during high quality film boiling, Leidenfrost temperature, critical heat flux, critical heat flux temperature, and the onset of nucleate boiling temperature. The correlations were validated against LH2, LN2, liquid methane, liquid oxygen, and liquid argon pipe quenching datasets. The eight datasets cover the following parameter ranges: pipe lengths of 0.1 to 6.5m; outer pipe diameters of 12.7 to 25.4 mm; pipe wall thicknesses from 0.51 to 1.64 mm; flow directions of upward, downward, and horizontal; gravity levels of 1g and 0g±0.01g. A numerical model assumes homogeneous mixing between the vapor and liquid and implicitly integrates the coupled energy equations for the pipe and fluid, as well as continuity for the fluid. The model was used to estimate the equilibrium quality and fluid mass accumulation along the pipes during chilldown from estimates of the fluid-pipe heat transfer extracted from temperature measurements. The correlations can be implemented in lumped parameter codes such as SINDA/FLUINT and the Generalized Fluid System Simulation Program (GFSSP) to improve the accuracy of chilldown time and chilldown boiloff mass predictions. Such predictions are useful for designing ground or in-space cryogenic liquid transfer systems.

Universal Correlations↗