At least 361 records · Page 20

Protecting Smart Buildings with STIG

This is a submission for the 2022 Intern Poster Session. The abstract of the poster is: Smart buildings are getting more common, and so are hackers that target them. The physical systems in our businesses and homes are now vulnerable to cyber attacks. Using STIG, an INL program that turns cybersecurity data into graphs, buildings can be better protected.

99 GENERAL AND MISCELLANEOUS↗

Building morphologies of the USA structures database; a gauntlet feature set

In recent years there has been a proliferation of methods and data to extract building footprints from satellite imagery. However there has been very little effort to provide additional insight about these buildings beyond their spatial location and shape. Features derived from their geometries can be used to better characterize these buildings which are critical for further research and development. In this work a set of 65 unique features for every building for more than 131 million buildings covering the US has been developed. This rich feature dataset will enable researchers, policymakers and various agencies to derive additional building characteristics like height, occupancy type, and help to gain valuable and new insights of the built environment.

Environmental sciences↗

Analytic Modeling of a Deep Shielding Problem

Previous generations of scientists would make tremendous efforts to simplify non-tractable problems and generate simpler models that preserved the fundamental physics. This process involved applying assumptions and simplifications to reduce the complexity of the problem until it reached a solvable form. Each assumption and simplification was chosen and applied with the intent to preserve the essential physics of the problem, since, if the core physics of the problem were eliminated, the simplified model served no purpose. Moreover, if done correctly, solutions to the reduced model would serve as useful approximations to the original problem. In a sense, solving the simple models laid the ground-work for and provided insight into the more complex problem. Today, however, the affordability of high performance computing has essentially replaced the process for analyzing complex problems. Rather than "building up" a problem by understanding smaller, simpler models, a user generally relies on powerful computational tools to directly arrive at solutions to complex problems. As computational resources grow, users continue trying to simulate new, more complex, or more detailed problems, resulting in continual stress on both the code and computational resources. When these resources are limited, the user will have to make concessions by simplifying the problem while trying to preserve important details. In the context of MCNP, simplifications typically come as reductions in geometry, or by using variance reduction techniques. Both approaches can influence the physics of the problem, leading to potentially inaccurate or non-physical results. Errors can also be introduced as a result of faulty input into a computational tool: something as simple as transposing numbers in a tally input can result in incorrect answers. In this paradigm, reduced complexity computational and analytical models still have an important purpose. The explicit form of an analytic solution is arguably the best way to understand the qualitative properties of simple models. In contrast to "building up" a complex problem through understanding simpler problems, results from detailed computational scenarios can be better explained by "building down" the complex model through simple models rooted in the fundamental or essential phenomenology. Simplified analytic and computational models can be used to 1) increase a user's confidence in the computational solution of a complex model, 2) confirm there are no user input errors, and 3) ensure essential assumptions of the simulation tool are preserved. This process of using analytic models to develop a more valuable analysis of simulation results is named the results analysis methodology. The utility of the results assessment methodology and a complimentary sensitivity analysis is exemplified through the analysis of the neutron flux in a dry used fuel storage cask. This application was chosen due to current scientific interest in used nuclear fuel storage.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analytic Modeling of a Deep Shielding Problem

Previous generations of scientists would make tremendous efforts to simplify non-tractable problems and generate simpler models that preserved the fundamental physics. This process involved applying assumptions and simplifications to reduce the complexity of the problem until it reached a solvable form. Each assumption and simplification was chosen and applied with the intent to preserve the essential physics of the problem, since, if the core physics of the problem were eliminated, the simplified model served no purpose. Moreover, if done correctly, solutions to the reduced model would serve as useful approximations to the original problem. In a sense, solving the simple models laid the ground-work for and provided insight into the more complex problem. Today, however, the affordability of high performance computing has essentially replaced the process for analyzing complex problems. Rather than "building up" a problem by understanding smaller, simpler models, a user generally relies on powerful computational tools to directly arrive at solutions to complex problems. As computational resources grow, users continue trying to simulate new, more complex, or more detailed problems, resulting in continual stress on both the code and computational resources. When these resources are limited, the user will have to make concessions by simplifying the problem while trying to preserve important details. In the context of the Monte Carlo N-Particle radiation transport simulation tool, simplifications typically come as reductions in geometry, or by using variance reduction techniques. Both approaches can influence the physics of the problem, leading to potentially inaccurate or non-physical results. Errors can also be introduced as a result of faulty input into a computational tool: something as simple as transposing numbers in a tally input can result in incorrect answers. In this paradigm, reduced complexity computational and analytical models still have an important purpose. The explicit form of an analytic solution is arguably the best way to understand the qualitative properties of simple models. In contrast to "building up" a complex problem through understanding simpler problems, results from detailed computational scenarios can be better explained by "building down" the complex model through simple models rooted in the fundamental or essential phenomenology. Simplified analytic and computational models can be used to 1) increase a user's confidence in the computational solution of a complex model, 2) confirm there are no user input errors, and 3) ensure essential assumptions of the simulation tool are preserved. This process of using analytic models to develop a more valuable analysis of simulation results is named the results assessment methodology. The utility of the results assessment methodology and a complimentary sensitivity analysis is exemplified through the analysis of the neutron flux in a dry used fuel storage cask. This application was chosen due to current scientific interest in used nuclear fuel storage.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Analytic Modeling of a Deep Shielding Problem

Previous generations of scientists would make tremendous efforts to simplify non-tractable problems and generate simpler models that preserved the fundamental physics. This process involved applying assumptions and simplifications to reduce the complexity of the problem until it reached a solvable form. Each assumption and simplification was chosen and applied with the intent to preserve the essential physics of the problem, since, if the core physics of the problem were eliminated, the simplified model served no purpose. Moreover, if done correctly, solutions to the reduced model would serve as useful approximations to the original problem. In a sense, solving the simple models laid the ground-work for and provided insight into the more complex problem. Today, however, the affordability of high performance computing has essentially replaced the process for analyzing complex problems. Rather than "building up" a problem by understanding smaller, simpler models, a user generally relies on powerful computational tools to directly arrive at solutions to complex problems. As computational resources grow, users continue trying to simulate new, more complex, or more detailed problems, resulting in continual stress on both the code and computational resources. When these resources are limited, the user will have to make concessions by simplifying the problem while trying to preserve important details. In the context of the Monte Carlo N-Particle radiation transport simulation tool, simplifications typically come as reductions in geometry, or by using variance reduction techniques. Both approaches can influence the physics of the problem, leading to potentially inaccurate or non-physical results. Errors can also be introduced as a result of faulty input into a computational tool: something as simple as transposing numbers in a tally input can result in incorrect answers. In this paradigm, reduced complexity computational and analytical models still have an important purpose. The explicit form of an analytic solution is arguably the best way to understand the qualitative properties of simple models. In contrast to "building up" a complex problem through understanding simpler problems, results from detailed computational scenarios can be better explained by "building down" the complex model through simple models rooted in the fundamental or essential phenomenology. Simplified analytic and computational models can be used to 1) increase a user's confidence in the computational solution of a complex model, 2) con firm there are no user input errors, and 3) ensure essential assumptions of the simulation tool are preserved. This process of using analytic models to develop a more valuable analysis of simulation results is named the results assessment methodology. The utility of the results assessment methodology and a complimentary sensitivity analysis is exempli fied through the analysis of the neutron flux in a dry used fuel storage cask. This application was chosen due to current scientific interest in used nuclear fuel storage.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development and testing of a performance evaluation methodology to assess the reliability of occupancy sensor systems in residential buildings

With the emergence of advanced occupancy sensor technologies to better detect occupancy in buildings, a universal methodology and metrics are required to evaluate and report sensor systems’ reliability and compare the performance across multiple sensor systems. Herein this research presents a methodology to assess the reliability of occupancy sensor systems in residential buildings in a controlled laboratory environment, including both “typical” and “failure” testing scenarios. The developed methodology was then implemented to evaluate a novel occupancy detection sensor system’s reliability. “Typical” testing evaluates the overall accuracy of the sensor system, which suggest how reliable the occupancy sensor system is over time. Results show that on average, the precision and recall are 0.75 and 0.70, indicating similar numbers of false positives and false negatives across the dataset. The overall accuracy of the tested sensor system was 62.4% to 76.4%. Failure testing results indicate whether there are influential variables impacting the sensor performance. For the tested sensor system, the number of occupants, presence of large objects, presence of interior light sources, and number of doors are not influential, while lighting level, location of occupants, additional door in the entry/exit area, and having the TV on are variables determined to impact the sensor system performance.

47 OTHER INSTRUMENTATION↗

Residential Building Energy Efficiency Field Studies: Low-Rise Multifamily

In recent years, the U.S. Department of Energy (DOE) has conducted a series of research studies to validate energy efficient building technologies in the field. Much of the work has focused on single-family construction, and some has also addressed commercial energy codes. The work detailed in this DOE-funded study (EE0007616) focuses on low-rise multifamily buildings (three stories or fewer above grade) in various regions of the United States, and reports on how state-level building codes are being implemented, both in terms of observed characteristics and also in terms of estimated energy impacts. Nearly 100 buildings across four states—Illinois, Minnesota, Oregon, and Washington—were sampled, which represent a range of climate types from mild temperature to very cold continental. Both common entry and outdoor entry buildings were included, and a parallel research project evaluated envelope air tightness and current still-evolving air tightness testing methods. Finally, a set of structured interviews of building designers and other relevant professionals was carried to out to gain more insight into this market. To the greatest extent possible, the methodology developed under the project for low-rise multifamily buildings mirrored the approach established by Pacific Northwest National Laboratory (PNNL) for single-family residential buildings (https://www.energy.gov/eere/buildings/downloads/residential-building-energy-code-field-study). This included the general approach to sampling, recruitment, and data collection, as well as data analysis and presentation. The range of permitting dates for the sites encompassed two energy code cycles in most regions. All states in the study had adopted a variation of the International Energy Conservation Code (IECC) for the structure of their state code. The low-rise multifamily occupancy presents a hybrid building type: most of the building’s conditioned floor area was covered by the residential chapter of the code while portions of the building (such as corridors and common spaces) fell under the commercial code chapter. The key items assessed in this work were: Building Shell—exterior wall insulation, ceiling insulation, foundation insulation, windows. Common Areas—HVAC and lighting. Living Units—lighting, ventilation. A few items were not assessed in detail, given their relative paucity in this occupancy type; these included duct leakage, pipe insulation, and hot water circulation controls. Building characteristics were collected via a combination of architectural, mechanical, electrical, and plumbing plan reviews and field inspections, and entered into a spreadsheet-based tool that was later queried to build a database. Data went through quality control both upon arrival and via a later semi-automated review and assurance process. Most of the data are presented graphically so that the reader can quickly assess compliance with the applicable energy codes (both by state and by code year). As a final step, EnergyPlus™ simulations were created for all buildings in the study to estimate both the as-found energy use intensity (EUI) and the energy and CO 2 that could be saved if features that were found to not meet code minimums were brought up to code. The savings estimates were tabulated for each of the four states in the study. The research team found that the single-family approach was largely applicable to low-rise multifamily buildings. This applies to both the data collection and the prototype EUI analysis. Most of the occupied space is living units and falls under residential energy codes, and many characteristics use similar envelope construction and relatively straightforward mechanical systems and lighting. One of the most challenging aspects of this work was to build an effective spreadsheet-based data collection instrument that could allow efficient collection of both building plan and field data. The research team is of the view that other methods could be equally effective if the work is done carefully with diligent quality control. The primary findings for the work center around the thermal envelope and mechanical systems and lighting at the sites: For thermal envelope components, the majority of buildings met or were better than the prescriptive code.This suggests that building designers and builders are aware of code requirements. In some cases, surveyed buildings were designed to qualify for energy efficiency certification programs. These buildings made up at least 20% of sampled buildings in each state. Almost all buildings met mechanical system efficiency requirements (for both living units and common areas). In some cases, sites employed systems that were considerably more efficient than required by the applicable energy code. Dwelling units had a majority of high-efficacy lighting, often in excess of the state’s residential code requirements. While high-efficacy fixtures were also typical in common areas (corridors and stairwells), lighting power densities (LPDs) in these areas were sometimes higher than levels dictated by the applicable part of the state commercial energy code. The simulation models run on a series of low-rise multifamily prototypes, informed by a composite of the field data collected, calculated annual EUIs of between 20 and 50 kBtu/ft2-yr, with the range representing the effects of both building characteristics and building location (climate zone). A detailed process (based on simulations of prototype buildings) was used to estimate the amount of avoided energy use that would occur if 100% adherence to energy codes were attained. The results indicated modest savings are attainable for items such as window thermal performance and common area lighting. The result is overall only a modest potential for additional energy savings, averaging about 10% of EUI.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Building Efficiency Targeting Tool for Energy Retrofits (BETTER) Application Programing Interface (API) (BETTER API) v1.0

The BETTER API allows advanced users and developers to access BETTER's analytical functionalities via HTTP requests from their own software platform without using the BETTER web-interface. API users prepare the input data and analysis configurations in a JSON format and send it to the web application via an HTTP request. The web application runs the analytical workflow on the back end and returns an HTTP response in JSON format. The user can then decide to render the results or further process it.

Szum, Carolyn↗

A bi-level advanced control framework for large-scale control of buildings with system-level impact

Increased electricity consumption combined with new forms of generation is testing the reliability of our grid infrastructure. This work describes a method to improve the reliability of the grid through large-scale advanced building control. This paper develops a bi-level distributed control framework to shift the load of 153 buildings to achieve a system-level objective of tracking a power reference signal. This bi-level control is based on the previously-developed ANPV-MPC, a predictive controller that uses a Bayesian neural network to generate an accurate control model and adapt to changing conditions over time. By shifting the building electricity demand to better match the available power, the grid system supplying the buildings is more reliable as evidenced by the analysis of node voltages across an IEEE 13-bus distribution system. The proposed bi-level control framework tracks the system-level power reference with enough accuracy to regulate node voltages across the IEEE 13-bus distribution system within ANSI limits of ±5%. Additionally, the adaptive nature of ANPV-MPC allows each building across the system to adapt to changing conditions, further amplifying the system-level reliability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

BuildingSync® v.2.7.0 (released 9.11.2025) [SWR-18-28]

BuildingSync® is a building data exchange schema to better enable integration between software tools and building data workflows. The schema's original use case was focused on commercial building energy audits; however, several additional use cases have been realized including building energy modeling and more high-level generic building data exchange. Version 2.7.0 adds new elements for file attachment feature and FederalBuilding, and generalizes usage of Optional Elements (e.g. EquipmentCondition, EquipmentID) to all assets/systems. BuildingSync helps streamline the data exchange process, improving the value of the data, minimizing duplication of effort for subsequent building data collection efforts (including audits), and facilitating the achievement of greater energy efficiency. This in done in part by standardizing on (a) reporting audits in an electronic format, (b) tracking proposed, implemented, and discarded energy conservation measures, and (c) storing building characteristics (at multiple levels) for audits, benchmarking, and building energy analysis. BuildingSync has several documents and tools available to help users understand how to best leverage BuildingSync. The list below are only a subset of the resources available. If new resources are discovered, then feel free to create a new pull request with the additions. Generic BuildingSync information is available on the DOE website and the project website. BuildingSync Examples - These examples are kept up to date and show a wide range of implementations. Any new update to BuildingSync is required to pass validation on these example files. BuildingSync Use Case Validator allows for users to determine if their instance complies with a specific use case for BuildingSync by checking if the required elements are implemented in an uploaded instance. An API is also provided for automated integration into other tools. Also, the website contains an easy way to view the entirety of the schema and how elements relate to the Building Exchange Data Exchange Specification. The Validator is open sourced here Use Case TestSuite provides a Python package for easier generation of BuildingSync use cases. BuildingSync use cases depend on the generation of schematron documents, which is time-consuming and difficult to implement well. The TestSuite allows users to define a use case using a more palatable CSV template, which it then turns into a Schematron document. The source code is available here. BuildingSync to OpenStudio/EnergyPlus. The translator is open sourced here. This project will translate a Level 1 (and partial Level 2) ASHRAE Energy Audit to a fully defined OpenStudio and EnergyPlus model. This project is in early Beta testing and any feedback is welcome!

Long, Nicholas [National Renewable Energy Lab. (NR↗

Thermal Conductivity of a Novel Salt-Hydrogel Complex as a Phase Change Material for Building Thermal Management

Use of electricity for space heating, ventilation and air conditioning in buildings may be better managed through temporary energy storage. Compared with electrochemical storage, the levelized cost of thermal energy storage systems can be lower depending on geographical location and thermophysical properties [1]. In any phase change material (PCM), the rate of absorption and release of thermal energy increases with higher thermal conductivity [2]. However, leading PCMs like paraffin waxes have thermal conductivities on the order of 0.1 W/mK. Glauber’s salt, a salt hydrate, possesses a relatively high thermal conductivity but suffers from supercooling and phase segregation. Research has shown that polymer-based composites with salt hydrates can prevent phase segregation and limit supercooling over hundreds of cycles [3] though the thermal conductivity of the composite may be reduced leading to low energy storage rates. Here, we report thermal conductivity measurements on polymer hydrogels which are stable in solutions of Glauber’s salt. To measure thermal conductivity of soft gels, we use a 3-omega method [4] where heat flows bidirectionally through a substrate below and through a gel placed on top. This suits measurements of both gels and liquids unlike transient plane heat source or transient hot wire methods. We report measurements of thermal conductivity of salt-hydrogel complexes as a function of temperature, cross-linking and salt concentration. In addition, we present modeling of thermal conductivity of sodium sulfate solutions with available theories. We finally employ polarized optical microscopy to observe inside the transparent hydrogel networks, showing that precipitating crystals may influence thermal conductivity measurements for high salt concentrations. Our thermal conductivity results combined with enthalpy of phase change, mass density and specific heat are essential to accurately design thermal storage systems for energy-efficient buildings.

composite, thermal conductivity↗

Skew-Symmetric adjacency matrices for clustering directed graphs

Graph clustering methods often critically rely on the symmetry of graph matrices. Developing analogous methods for digraphs often proves more challenging, because digraph matrices are typically asymmetric and not orthogonally diagonalizable. However, researchers have recently proposed several complex-valued Hermitian digraph matrices. In particular, one such representation has been utilized as an input to an algorithm for finding imbalanced cuts. In this work, we establish an algebraic relationship between this matrix and an associated real-valued matrix. We show using this real-valued matrix for imbalanced cut-finding algorithms is not only sufficient but advantageous. Our algorithm uses less memory and asymptotically less computation while provably preserving solution quality. We also show our method can be easily implemented using standing computational building blocks, possesses better numerical properties, and loans itself to a natural interpretation via an objective function relaxation argument. We empirically demonstrate these advantages on real world data sets and show how our algorithm can uncover meaningful cluster structure.

Hayashi, Koby↗

Humming Trains in Seismology: An Opportune Source for Probing the Shallow Crust

Abstract Seismologists are eagerly seeking new and preferably low-cost ways to map and track changes in the complex structure of the top few kilometers of the crust. By understanding it better, they can build on what is known regarding important, practical issues. These include telling us whether imminent earthquakes and volcanic eruptions are generating telltale underground signs of hazard, about mitigation of induced seismicity such as from deep injection of wastewater, how the Earth and its atmosphere couple, and where accessible natural resources are. Passive seismic imaging usually relies on blind correlations within extended recordings of Earth’s ceaseless “hum” or coda of well-mixed, small vibrations. In this article, we propose a complementary approach. It is seismic interferometry using opportune sources—specifically ones not stationary in time and moving in a well-understood configuration. Its interpretation relies on an accurate understanding of how these sources radiate seismic waves, precise timing, careful placement of pairs of listening stations, and seismic phase differentiation (surface and body waves). Massive freight trains were only recently recognized as such a persistent, powerful cultural (human activity-caused) seismic source. One train passage may generate a tremor with an energy output of a magnitude 1 earthquake and be detectable for up to 100 km from the track. We discuss the source mechanisms of train tremors and review the basic theory on sources. Finally, we present case studies of body- and surface-wave retrieval as an aid to mineral exploration in Canada and to monitoring of a southern California fault zone. We believe noise recovery from this new signal source, together with dense data acquisition technologies such as nodes or distributed acoustic sensing, will deeply transform our ability to monitor activity in the shallow crust at sharpened resolution in time and space.

Geochemistry & Geophysics↗

Residential Energy Efficiency Design Guide for Tribal Lands

Homeowners and renters on tribal lands have historically faced a disproportionate energy burden compared to the United States as a whole. The Indian Health Service (IHS), which serves these communities, strives to meet aggressive energy performance goals when constructing their residential housing. Challenges common in rural locations can hinder progress toward those goals, such as availability of materials, access to specialized labor, and budget constraints. This guide is for architects and builders who aim to incorporate energy efficiency (EE) into their residential designs. This report presents commercially viable energy efficiency packages for a variety of locations and home inputs to help guide home builders in choosing improvements for energy performance. The intention is to provide a diverse set of packages that can be used during the design phase to achieve energy savings compared to a code minimum building design. By presenting a set of diverse options with similar expected energy savings and life-cycle costs, final decisions can be left up to the building designers who can better determine the appropriate package given local costs, materials, and labor availability. Although this guide was developed for IHS projects, it can be used to help designers and construction professionals better make cost-effective choices when a detailed, project-specific building energy analysis is not possible.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Final Report on the 2023 LaserNetUS Annual Meeting

LaserNetUS is a network of advanced laser facilities created by the Department of Energy Fusion Energy Sciences to provide greatly improved access to the most powerful lasers in North America. It is dedicated to the development of the high energy density physics workforce, especially the training and advancement of early career scientists. The network is helping to build a larger, better skilled and more diverse scientific community. The result of the work of LaserNetUS towards these goals was on display at the 2023 LaserNetUS Annual Meeting, held at the University of Maryland, College Park, Maryland on June 27-29, 2023 (Figure 1). The meeting had 216 participants, the largest sponsor/exhibitor participation of any LaserNetUS annual meeting, wide ranging plenary, invited, and contributed talks, a vigorous poster session, outreach to a diverse range of students, and two awards sessions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Technical Challenges in Reliable Microelectronics Packaging of Microelectromechanical Systems (MEMS) for Space Applications

MEMS have shown a significant promise in the last decade for a variety of applications such as air-bag, pressure sensors, accelerometer, microgyro, chemical sensors, artificial nose, etc. Standard semiconductor microelectronics packaging needs the integrated circuits (IC) to be protected from the harsh environment, and provide electrical communication with the other parts of the circuit, facilitate thermal dissipation efficiently, and impart mechanical strength to the silicon die. Microelectronics packaging involves wafer dicing, bonding, lead attachment, encapsulation to protect from the environment, electrical integrity, and package leak tests to assure the reliable IC packaging technology. Active elements or microstructures in MEMS devices often interfaces with the hostile environment where packaging leak tests and testing of such devices using chemical and mechanical parameters will be very difficult and expensive. Packaging of MEMS is significantly complex as they serve to protect from the environment and microstructures interact with the same environment to measure or affect the desired physical or chemical parameters. The most of the silicon circuitry is sensitive to temperature, moisture, magnetic field, light, and electromagnetic interference. The package must then protect the on-board silicon circuitry while simultaneously exposing the microsensor to the effect it measures to assure the packaging technology of MEMS. MEMS technology has a major application in developing a microspacecraft for space systems provided reliability of MEMS packaging technology is sufficiently addressed. This MEMS technology would eventually miniaturize many of the components of the spacecraft to reach the NASA's goal by building faster, cheaper, better, smaller spacecraft to explore the space more effectively. This paper discusses the latest developments in the MEMS technology and challenging technical issues in the packaging of hermetically sealed and non-hermetically sealed MEMS sensor devices for microspacecraft applications.

Ramesham, Rajeshuni↗

Assessment and Assurance of Microelectronics Packaging Technology of Microelectromechanical Systems (MEMS)

Microelectromechanical systems (MEMS) have shown a significant promise in the last decade for a variety of applications such as air-bag, pressure sensors, accelerometer, microgyro, etc. Standard semiconductor microelectronics packaging needs the integrated circuits to be protected from the harsh environment, and provide electrical communication with the other parts of the circuit, facilitate thermal dissipation efficiently, and impart mechanical strength to the silicon die. Microelectronics packaging involves wafer dicing, bonding, lead attachment, encapsulation to protect from the environment, electrical integrity, and package leak tests to assure the packaging technology. In the case of MEMS the microstructures (active elements) often interfaces with the hostile environment where packaging leak tests and testing of such devices using chemical and mechanical parameters will be very difficult and expensive. Packaging of MEMS is significantly complex as they serve to protect from the environment and microstructures interact with the same environment to measure or affect the desired physical or chemical parameters. The most of the silicon circuitry is sensitive to temperature, moisture, magnetic field, light, and electromagnetic interference. The package must then protect the on-board silicon circuitry while simultaneously exposing the microsensor to the effect it 'measures to assure the MEMS technology by lowering the risk to zero. MEMS technology has a major application in developing a microspacecraft for space systems provided assurance of MEMS technology is sufficiently addressed nondestructively. This technology would eventually miniaturize many of the components of the spacecraft to reach the NASA's safety and mission assurance goal by building faster, cheaper, better, smaller spacecraft to explore the space more effectively by teaming-up with the other NASA centers using the limited resources available. This paper discusses the latest developments in the MEMS technology and challenging issues in the packaging of hermetically sealed and non-hermetically sealed MEMS sensor devices based on silicon, poly-silicon, and other materials for microspacecraft applications considering the space environment and reliability assurance qualification guidelines in perspective. Acknowledgments: The above research work is supported by the NASA Electronics Parts and Packaging Program (NEPP) and performed by the Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA under a contract with the NASA - Code Q for the Office of Safety and Mission Assurance Program 323-79.

Ramesham, Rajeshuni↗

Predicting Quadcopter Noise With The Lattice-Boltzmann Method

From small delivery Unmanned Aircraft Systems (UAS) to short-haul building-to-building aircraft, urban air mobility is gaining traction as a new approach to tackle the problem of transportation in densely populated areas. NASA’s vision for vertical lift vehicles is to capitalize on and improve unique capabilities to greatly benefit the United States’ growing civil flight requirements. This vision is embodied in the Revolutionary Vertical Lift Technology (RVLT)project [1]. Beyond safety, one of the chief concerns of communities where drones are becoming more popular is the noise they generate. Noise will undoubtedly be one of the major obstacles to public acceptance of any new urban air mobility technology. The ability to predict the acoustics of new conceptual aircraft with multiple rotors and complex fuselages is critical to enable the creation of quieter designs. The objective of this research is to build up a better physical understanding of the noise generated by a typical quadcopter drone and what it takes to predict it from first principles using computational fluid dynamics (CFD) with the Lattice-Boltzmann method (LBM). The specific goals are to establish best practices to predict multi-rotor and vehicle interaction noise with LBM, validate these predictions by comparing to wind tunnel measurements, and assess the computational cost necessary to obtain accurate predictions.

Francois Cadieux↗