Precise Truss Assembly using Commodity Parts and Low Precision Welding

We describe an Intelligent Precision Jigging Robot (IPJR), which allows high precision assembly of commodity parts with low-precision bonding. We present preliminary experiments in 2D that are motivated by the problem of assembling a space telescope optical bench on orbit using inexpensive, stock hardware and low-precision welding. An IPJR is a robot that acts as the precise "jigging", holding parts of a local assembly site in place while an external low precision assembly agent cuts and welds members. The prototype presented in this paper allows an assembly agent (in this case, a human using only low precision tools), to assemble a 2D truss made of wooden dowels to a precision on the order of millimeters over a span on the order of meters. We report the challenges of designing the IPJR hardware and software, analyze the error in assembly, document the test results over several experiments including a large-scale ring structure, and describe future work to implement the IPJR in 3D and with micron precision.

Komendera, Erik↗

Evaluation of the Paratrend Multi-Analyte Sensor for Potential Utilization in Long-Duration Automated Cell Culture Monitoring

BACKGROUND: Compact and automated sensors are desired for assessing the health of cell cultures in biotechnology experiments. While several single-analyte sensors exist to measure culture health, a multi-analyte sensor would simplify the cell culture system. One such multi-analyte sensor, the Paratrend 7 manufactured by Diametrics Medical, consists of three optical fibers for measuring pH, dissolved carbon dioxide (pCO(2)), dissolved oxygen (pO(2)), and a thermocouple to measure temperature. The sensor bundle was designed for intra-vascular measurements in clinical settings, and can be used in bioreactors operated both on the ground and in NASA's Space Shuttle and International Space Station (ISS) experiments. METHODS: A Paratrend 7 sensor was placed at the outlet of a bioreactor inoculated with BHK-21 (baby hamster kidney) cells. The pH, pCO(2), pO(2), and temperature data were transferred continuously to an external computer. Cell culture medium, manually extracted from the bioreactor through a sampling port, was also assayed using a bench top blood gas analyzer (BGA). RESULTS: Two Paratrend 7 sensors were used over a single cell culture experiment (64 days). When compared to the manually obtained BGA samples, the sensor had good agreement for pH, pCO(2), and pO(2) with bias (and precision) 0.005(0.024), 8.0 mmHg (4.4 mmHg), and 11 mmHg (17 mmHg), respectively for the first two sensors. A third Paratrend sensor (operated for 141 days) had similar agreement (0.02+/-0.15 for pH, -4+/-8 mm Hg for pCO(2), and 24+/-18 mmHg for pO(2)). CONCLUSION: The resulting biases and precisions are com- parable to Paratrend sensor clinical results. Although the pO(2) differences may be acceptable for clinically relevant measurement ranges, the O(2) sensor in this bundle may not be reliable enough for the ranges of pO(2) in these cell culture studies without periodic calibration.

Validation Studies↗

A benchtop shock physics laboratory: Ultrafast laser driven shock spectroscopy and interferometry methods

Common Ti:sapphire chirped pulse amplified laser systems can be readily adapted to be both a generator of adjustable pressure shock waves and a source for multiple probes of the ensuing ultrafast shock dynamics. Here, we detail experimental considerations for optimizing the shock generation, interferometric characterization, and spectroscopic probing of shock dynamics with visible and mid-infrared transient absorption. While we have reported results using these techniques elsewhere, in this work we detail how the spectroscopies are integrated with the shock and interferometry experiment. The interferometric characterization uses information from beams at multiple polarizations and angles of incidence combined with thin film equations and shock dynamics to determine the shock velocity, particle velocity, and shocked refractive index. Visible transient absorption spectroscopy uses a white light supercontinuum in a reflection geometry, synchronized to the shock wave, to time resolve shock-induced changes in visible absorption such as changes to electronic structure or strongly absorbing products and intermediates due to reaction. Mid-infrared transient absorption spectroscopy uses two color filamentation supercontinuum generation combined with a simple thermal imaging microbolometer spectrometer to enable broadband single shot detection of changes in the vibrational spectra. These methods are reflected here in the study of shock dynamics at stresses from 5 to 30 GPa in organic materials and from a few GPa to >70 GPa in metals with spatial resolution of a few micrometers and temporal resolution of a few picoseconds. This experiment would be possible to replicate in any ultrafast laser laboratory containing a single bench top commercial chirped pulse amplification laser system.

47 OTHER INSTRUMENTATION↗

The potential role of aerobic biological waste treatment in regenerative life support systems

The purpose of the paper is to make a preliminary assessment of the feasibility of using aerobic biological waste treatment in closed systems. Issues that are addressed in this paper are: (1) how high a degree of material balance is possible, (2) how much might such a system weigh, and (3) how would system closure and weight be affected if animals were included in the system. A computer model has been developed to calculate for different scenarios the compositions and amounts of the streams entering or leaving the waste treatment system and to estimate the launch weight of such a system. A bench scale apparatus has been built to mimic the proposed waste treatment system; the experiments are used to verify model predictions and to improve model parameter estimations.

Shuler, M. L.↗

Bench-Scale Process for Low-Cost Carbon Dioxide (CO2) Capture Using a Phase-Changing Absorbent

The objective of this project is to design and build a bench-scale process for a novel phase-changing aminosilicone-based CO2-capture solvent. The project will establish scalability and technical and economic feasibility of using a phase-changing CO2-capture absorbent for post-combustion capture of CO2 from coal-fired power plants with 90% capture efficiency and 95% CO2 purity at a cost of $40/tonne of CO2 captured by 2025 and a cost of <$10/tonne of CO2 captured by 2035. In the first budget period of this project, the bench-scale phase-changing CO2 capture process was designed using data and operating experience generated under a previous project (ARPA-e project DE-AR0000084). Sizing and specification of all major unit operations was completed, including detailed process and instrumentation diagrams. The system was designed to operate over a wide range of operating conditions to allow for exploration of the effect of process variables on CO2 capture performance.

Westendorf, Tiffany↗

First experiments with the negative ion source NIO1

Neutral Beam Injectors (NBIs), which need to be strongly optimized in the perspective of DEMO reactor, request a thorough understanding of the negative ion source used and of the multi-beamlet optics. A relatively compact radio frequency (rf) ion source, named NIO1 (Negative Ion Optimization 1), with 9 beam apertures for a total H{sup −} current of 130 mA, 60 kV acceleration voltage, was installed at Consorzio RFX, including a high voltage deck and an X-ray shield, to provide a test bench for source optimizations for activities in support to the ITER NBI test facility. NIO1 status and plasma experiments both with air and with hydrogen as filling gas are described. Transition from a weak plasma to an inductively coupled plasma is clearly evident for the former gas and may be triggered by rising the rf power (over 0.5 kW) at low pressure (equal or below 2 Pa). Transition in hydrogen plasma requires more rf power (over 1.5 kW)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the temperature of a stator winding with fiber-optic sensors in bench tests of a turbogenerator

The temperature of the elementary conductors of the stator winding of a 225 MW turbogenerator has been measured using miniature fiber-optic sensors, built in to the winding during manufacture. This is the first time that practical bench tests have been made in Russian electrical machine construction practice. The results of the experiment are used as the initial data for determining important parameters of the construction of turbogenerators with air cooling, namely, the thermal conductivity of the body insulation in the slot, and the heat-transfer coefficient in the front parts of the stator winding.

42 ENGINEERING↗

Investigating the process of white etching crack initiation in bearing steel

White etching cracks (WECs) have been identified as a dominant mode of premature failure within wind turbine gearbox bearings. Though WECs have been reported in the field for over a decade, the conditions leading to WECs, and the process by which this failure culminates, are both highly debated. In previously published work, the generation of WECs on a benchtop scale was linked to sliding at the surface of the test sample, it was also postulated that the generation of WECs was dependent on the cumulative energy that had been applied to the sample over the entirety of the test. In this paper, a three ring on roller bench top test rig is used to systematically alter the cumulative energy that a sample experiences through changes in normal load, sliding, and run time, in an attempt to correlate cumulative energy with the formation of WECs. It was determined that, in the current test setup, the presence of WECs can be predicted by this energy criterion. The authors then used this information to study the process by which WECs initiate. Lastly, it was found that, under the current testing conditions, the formation of a dark etching microstructure precedes the formation of a crack, and a crack precedes the formation of white etching microstructure.

17 WIND ENERGY↗

Thermal decomposition of expanded polystyrene in a pebble bed reactor to get higher liquid fraction yield at low temperatures

Expanded polystyrene is one of the polymers produced in large quantities due to its versatile application in different fields. This polymer is one of the most intractable components in municipal solid waste. Disposal of polymeric material by pyrolysis or catalytic cracking yields valuable hydrocarbon fuels or monomers. Literature reports different types of reactors and arrangements that have uniform temperatures during pyrolysis and catalytic cracking. The present study focuses on reducing the temperature to maximize the quantity of styrene monomer in the liquid product. A bench scale reactor has been developed to recover the styrene monomer and other valuable chemicals. Experiments were carried under partial oxidation and vacuum conditions in the temperature range of 300-500 deg. C. In the pyrolysis optimization studies, the best atmospheric condition was determined to be vacuum, the pyrolysis temperature should be 500 deg. C, yield of liquid product obtained was 91.7% and yield of styrene obtained was 85.5%. In the characterization studies, distillation and IR spectroscopy experiments were carried out. The remaining of the liquid product comprises of benzene, ethyl benzene, and styrene dimers and trimers.

54 ENVIRONMENTAL SCIENCES↗

Analysis of materials from MSFC LDEF experiments

In preparation for the arrival of the Long Duration Exposure Facility (LDEF) samples, a material testing and handling approach was developed for the evaluation of the materials. A configured lab was made ready for the de-integration of the LDEF experiments. The lab was prepared to clean room specifications and arranged with the appropriate clean benches, tables, lab benches, clean room tools, particulate counter, and calibrated and characterized analytical instrumentation. Clean room procedures were followed. Clean room attire and shoe cleaning equipment were selected and installed for those entering. Upon arrival of the shipping crates they were taken to the lab, logged in, and opened for examination. The sample trays were then opened for inspection and test measurements. The control sample measurements were made prior to placement into handling and transport containers for the flight sample measurements and analysis. Both LDEF flight samples and LDEF type materials were analyzed and tested for future flight candidate material evaluation. Both existing and newly purchased equipment was used for the testing and evaluation. Existing Space Simulation Systems had to be upgraded to incorporate revised test objectives and approaches. Fixtures such as special configured sample holders, water, power and LN2 feed-throughs, temperature measurement and control, front surface mirrors for reflectance and deposition, and UV grade windows had to be designed, fabricated, and installed into systems to achieve the revised requirements. New equipment purchased for LDEF analysis was incorporated into and/or used with existing components and systems. A partial list of this equipment includes a portable monochromator, enhanced UV System, portable helium leak detector for porosity and leak measurements, new turbo pumping system, vacuum coaster assembly, cryopumps, and analytical and data acquisition equipment. A list of materials tested, equipment designed, fabricated and installed, systems used, and analytical research accomplished on both LDEF flight samples and on similar materials which were lab tested for a comparative analysis to the LDEF flight samples is presented.

Johnson, R. Barry↗

High Bandwidth Differential Amplifier for Shock Experiments

We developed a high bandwidth differential amplifier for gas gun shock experiments/applications. The circuit has a bandwidth > 1 GHz, and is capable of measuring signals of ≤1.5 V with a common mode rejection of 250 V. Conductivity measurements of gas gun targets are measured by flowing high currents through the targets. The voltage is measured across the target using a technique similar to a four-point probe. Because of the design of the current source and load, the target voltage is approximately 250 V relative to ground. Since the expected voltage change in the target is < 1 V, the differential amplifier must have a large common mode rejection. High pass filters suppress internal ringing of operational amplifiers. Results of bench tests are shown.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experiment-Based Verification of the SAFR/V1 Module of the EVKLID/V2 Integral Code for Thermal Breakdown of Fuel Pins in a Fast Reactor

The results of verification of the IBRAE-developed SAFR/V1 module, describing in the EVKLID/V2 integral code the thermal breakdown of fuel pins, on the basis of data obtained using experimental facilities. The experiments performed on the TREAT and DEH facilities at the Argonne National Laboratory and on a bench at the Nizhny Novgorod State Technical University were picked for the verification process. The computational error was evaluated for individual parameters on the basis of the verification results. The impact of the uncertainties in the initial data on the computational results was analyzed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Electromagnetic Energy-Assisted Thermal Conversion of Fossil-Based Hydrocarbons to Low-Cost Hydrogen

The goal of this project was to develop and optimize catalysts for methane decomposition, particularly focusing on regeneration via an electromagnetic energy-assisted mechanism, to produce hydrogen more cost-effectively compared to electrolysis routes. To achieve this goal, the project pursued several key objectives. The project began with the preparation and testing of various catalysts. A nickel-silica based catalyst was identified as the most promising material for the pyrolysis of methane into carbon and hydrogen. Kinetic parameters for methane decomposition were determined, aiding in computational modeling efforts. Structured catalysts were investigated, highlighting the need for frequent cleaning or regeneration to maintain performance, with methane conversion rates exceeding 70% in tube furnace tests. Computational fluid dynamics modeling was employed to optimize reactor designs and electrode angles, leading the project team to propose a multi-compartment thermal conversion system for larger setups. This modeling work was important in understanding reaction characteristics, carbon deposition rates, and temperature profiles under various conditions. A bench-scale reactor system was assembled to evaluate catalyst regeneration using electromagnetic energy-assisted mechanisms. Experiments demonstrated the potential for carbon removal, though further optimization is needed. The carbon produced from the methane conversion process was evaluated for potential use in lithium-ion battery electrodes. The carbon exhibited properties similar to commercially available high-purity multi-walled carbon nanotubes and nanofibers, with a carbon content greater than 95%. Coin cell batteries assembled with this carbon showed that lower replacement levels (10% to 33%) outperformed the control group, improving specific capacity density and stability. However, higher replacement levels (100%) demonstrated poorer performance, suggesting that excessive carbon substitution negatively impacts battery performance. These findings indicate the potential marketability of the produced carbon as a component in lithium-ion batteries, though further testing is necessary to confirm long-term advantages and disadvantages associated with the use of the carbon product. These results however justified further technoeconomic assessments to determine if the process can provide low-cost hydrogen. The economic feasibility and technical performance of methane decomposition for hydrogen production were assessed, focusing on three plant configurations: 100E (electrically heated), 100C (combustion heated using produced hydrogen), and PE-Hybrid (a combination of pyrolysis (indicating decomposition) and electrolysis). The Levelized Cost of Hydrogen (LCOH) for the pyrolysis configurations was found to be approximately 25% lower than that of electrolysis. The 100E configuration had the lowest LCOH at $\$$3.12/kg. Including carbon product sales significantly improved the economics, with the 100C configuration achieving a negative LCOH of -$\$$0.35/kg. The PE-Hybrid configuration was not economically advantageous compared to pure pyrolysis plants due to its complexity and additional equipment requirements. Ultimately, methane pyrolysis presents a viable method for near carbon dioxide-free hydrogen production, with significant economic advantages over electrolysis, especially when considering the sale of carbon byproducts. The 100E and 100C configurations showed the most promise, with the choice between them ultimately depending on the prices of power and natural gas. In conclusion, this technology has the potential to lower hydrogen production costs by leveraging the methane decomposition process with the sale of valuable carbon byproducts. By optimizing catalyst performance and integrating electromagnetic energy-assisted regeneration, the process can achieve higher efficiency and economic viability, making it a competitive alternative to traditional hydrogen production methods.

08 HYDROGEN↗

Development of a method for fabricating metallic matrix composite shapes by a continuous mechanical process

The continuing efforts in upscaling to produce larger diameter Al/B tubes are described. While the basic methodology remains unchanged, the larger volume of acrylic binder material and its removal by dissolution in toluene had to be performed by dynamic scrubbing. Similarly, the boron and MCF continuous length requirements increased when a 6 foot long by 7 inches wide mat was needed. These modifications and associated problems are described fully with schematics. Also included are seven experiments conducted to prepare larger tubes. The thermal profile, drawing speeds, and furnace positions in the draw bench bay are presented along with metallographic evidence of composite cross sections.

Divecha, A. P.↗

Impact of scaling on the nitric-glycolic acid flowsheet

Savannah River Remediation (SRR) is considering using glycolic acid as a replacement for formic acid in Sludge Receipt and Adjustment Tank (SRAT) processing in the Defense Waste Processing Facility (DWPF). Catalytic decomposition of formic acid is responsible for the generation of hydrogen, a potentially flammable gas, during processing. To prevent the formation of a flammable mixture in the offgas, an air purge is used to dilute the hydrogen concentration below the 60% of the Composite Lower Flammability Limit (CLFL). The offgas is continuously monitored for hydrogen using Gas Chromatographs (GCs). Since formic acid is much more volatile and toxic than glycolic acid, a formic acid spill would lead to the release of much larger quantities to the environment. Switching from formic acid to glycolic acid is expected to eliminate the hydrogen flammability hazard leading to lower air purges, thus downgrading of Safety Significant GCs to Process Support GCs, and minimizing the consequence of a glycolic acid tank leak in DWPF. Overall this leads to a reduction in process operation costs and an increase in safety margin. Experiments were completed at three different scales to demonstrate that the nitric-glycolic acid flowsheet scales from the 4-L lab scale to the 22-L bench scale and 220-L engineering scale. Ten process demonstrations of the sludge-only flowsheet for SRAT and Slurry Mix Evaporator (SME) cycles were performed using Sludge Batch 8 (SB8)-Tank 40 simulant. No Actinide Removal Process (ARP) product or strip effluent was added during the runs. Six experiments were completed at the 4-L scale, two experiments were completed at the 22-L scale, and two experiments were completed at the 220-L scale. Experiments completed at the 4-L scale (100 and 110% acid stoichiometry) were repeated at the 22-L and 220-L scale for scale comparisons.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An electron cyclotron resonance ion source based low energy ion beam platform

To satisfy the requirements of surface and atomic physics study in the field of low energy multiple charge state ion incident experiments, a low energy (10 eV/q-20 keV/q) ion beam platform is under design at IMP. A simple test bench has been set up to test the ion beam deceleration systems. Considering virtues such as structure simplicity, easy handling, compactness, cost saving, etc., an all-permanent magnet ECRIS LAPECR1 [Lanzhou all-permanent magnet electron cyclotron resonance (ECR) ion source No. 1] working at 14.5 GHz has been adopted to produce intense medium and low charge state ion beams. LAPECR1 source has already been ignited. Some intense low charge state ion beams have been produced on it, but the first test also reveals that many problems are existing on the ion beam transmission line. The ion beam transmission mismatches result in the depressed performance of LAPECR1, which will be discussed in this paper. To obtain ultralow energy ion beam, after being analyzed by a double-focusing analyzer magnet, the selected ion beam will be further decelerated by two afocal deceleration lens systems, which is still under design. This design has taken into consideration both ions slowing down and also ion beam focusing. In this paper, the conceptual design of deceleration system will be discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Hands-on Course on Intensified Membrane Processes for Sustainable Water Purification

The lack in process intensification (PI) training may be limiting processes to achieve sustainability goals. Furthermore, this project developed a hands-on course on intensified membrane processes to address knowledge gaps in PI. Bench-scale activities introduced concepts of membrane separation, operating engineering-scale modules provided a near-industrial experience, and simulation software allowed modeling and optimization of a process. Student evaluations showed that the combination of modeling, experimental, and peer-instruction work helped them understand the application of theoretical concepts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗