Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Balloon”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

UV photon counting detectors for high-altitude balloon and sounding rocket experiments

We report on development of ultraviolet photon counting detectors based on the 2D-doped and atomic layer deposition (ALD) custom coated electron multiplying CCD (EMCCDs) and their deployment in a high-altitude balloon experiment Faint Intergalactic-medium Redshifted Emission Balloon (FIREBall)-2 that was launched on September 22, 2018. The detector quantum efficiency (QE) was optimized for the narrow stratospheric window of a balloon at 200 - 225 nm.

Jones, Todd J.↗

Shaping Effects on Non-Ideal Ballooning Mode

The dependence of shaping effects on the growth rate of collisionless and resistive ballooning mode (CBM/RBM) is numerically researched. Furthermore, that of the drift ballooning modes (DCBM/DRBM) is investigated by taking kinetic effects into account. Resistivity scans of linear growth rates of CBM/RBM and DCBM/DRBM in a circular geometry show that both modes have 3 branches in accordance with decreasing resistivity, fast, resistive and collisionless branch. The last two branches are in the edge relevant resistivity regime and are in the scope of this paper. For CBM/RBM, shaping effect on the growth rate becomes weak with increasing resistivity and the growth rate monotonically increases with decrease of the elongation and increase of the triangularity, on the other hand, the opposite tendency appears on the triangularity for DCBM, namely it weakly decreases with increase of the triangularity. This fact indicates that the inverted D-shaped equilibrium can be unstable against DCBM compared with the D-shaped equilibrium.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Power Systems Design for Long Duration Ballooning

The Columbia Scientific Balloon Facility has been designing and building high-altitude balloon power systems for over 26 years. With that experience, we have found certain types of PV panels, batteries, and charge controllers that are reliable in stratospheric environments. The ultimate goal is to ensure that power systems will provide power reliably throughout the duration of an LDB flight. The purpose of this presentation is to provide some general guidelines and best practices for power system design.

Long Duration Balloon↗

Fracture and Collapse of Balloon-Expandable Stents in the Bilateral Common Iliac Arteries Due to Shiatsu Massage

We report a case of stent fracture and collapse of balloon-expandable stents caused by shiatsu massage. A 76-year-old man presented with complaints of intermittent claudication of the right lower extremity. Stenoses of the bilateral common iliac arteries (CIAs) were detected. Balloon-expandable stents were deployed in both CIAs, resulting in resolution of symptoms. Five months later, pelvis x-ray showed collapse of both stents. Despite the stent collapse, the patient was asymptomatic, and his ankle brachial index values were within the normal range. Further history showed that the patient underwent daily shiatsu therapy in the umbilical region, which may have triggered collapse of the stent. Physicians should advise patients to avoid compression of the abdominal wall after implantation of a stent in the iliac artery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Developments of Highly Multiplexed, Multi-chroic Pixels for Balloon-Borne Platforms

We present our work to develop and characterize low thermal conductance bolometers that are part of sinuous antenna multi-chroic pixels (SAMP). We use longer, thinner and meandered bolometer legs to achieve 9 pW/K thermal conductance bolometers. We also discuss the development of inductor–capacitor chips operated at 4 K to extend the multiplexing factor of the frequency domain multiplexing to 105, an increase of 60% compared to the factor currently demonstrated for this readout system. This technology development is motivated by EBEX-IDS, a balloon-borne polarimeter designed to characterize the polarization of foregrounds and to detect the primordial gravity waves through their B-mode signature on the polarization of the cosmic microwave background. EBEX-IDS will operate 20,562 transition edge sensor bolometers spread over 7 frequency bands between 150 and 360 GHz. Balloon and satellite platforms enable observations at frequencies inaccessible from the ground and with higher instantaneous sensitivity. This development improves the readiness of the SAMP and frequency domain readout technologies for future satellite applications.

42 ENGINEERING↗

Is There a Safety Concern for Drug-Coated Balloons in Peripheral Arterial Disease?

Purpose of Review: Drug-coated balloons (DEB) and drug-eluting stents (DES) emerged as a tool to aid in lowering the rates of neointimal hyperplasia and target lesion restenosis following endovascular peripheral arterial disease (PAD) interventions. Recent Findings: Although the initial trials comparing these devices with non-drug balloons and stents showed favorable results, more recent data raised concerns regarding the mid to long-term safety of these devices. Summary: In this review, we will discuss the evolution of endovascular therapy for PAD, with highlights regarding the recent debates on the long-term safety of the drug-coated devices for treatment of PAD.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Real-Time Study of Prostate Intrafraction Motion During External Beam Radiotherapy With Daily Endorectal Balloon

Purpose: To prospectively investigate intrafraction prostate motion during radiofrequency-guided prostate radiotherapy with implanted electromagnetic transponders when daily endorectal balloon (ERB) is used. Methods and Materials: Intrafraction prostate motion from 24 patients in 787 treatment sessions was evaluated based on three-dimensional (3D), lateral, cranial-caudal (CC), and anterior-posterior (AP) displacements. The mean percentage of time with 3D, lateral, CC, and AP prostate displacements >2, 3, 4, 5, 6, 7, 8, 9, and 10 mm in 1 minute intervals was calculated for up to 6 minutes of treatment time. Correlation between the mean percentage time with 3D prostate displacement >3 mm vs. treatment week was investigated. Results: The percentage of time with 3D prostate movement >2, 3, and 4 mm increased with elapsed treatment time (p < 0.05). Prostate movement >5 mm was independent of elapsed treatment time (p = 0.11). The overall mean time with prostate excursions >3 mm was 5%. Directional analysis showed negligible lateral prostate motion; AP and CC motion were comparable. The fraction of time with 3D prostate movement >3 mm did not depend on treatment week of (p > 0.05) over a 4-minute mean treatment time. Conclusions: Daily endorectal balloon consistently stabilizes the prostate, preventing clinically significant displacement (>5 mm). A 3-mm internal margin may sufficiently account for 95% of intrafraction prostate movement for up to 6 minutes of treatment time. Directional analysis suggests that the lateral internal margin could be further reduced to 2 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Extended (5-year) Outcomes of Accelerated Partial Breast Irradiation Using MammoSite Balloon Brachytherapy: Patterns of Failure, Patient Selection, and Dosimetric Correlates for Late Toxicity

Purpose: Accelerated partial breast irradiation (APBI) with balloon and catheter-based brachytherapy has gained increasing popularity in recent years and is the subject of ongoing phase III trials. Initial data suggest promising local control and cosmetic results in appropriately selected patients. Long-term data continue to evolve but are limited outside of the context of the American Society of Breast Surgeons Registry Trial. Methods and Materials: A retrospective review of 157 patients completing APBI after breast-conserving surgery and axillary staging via high-dose-rate {sup 192}Ir brachytherapy from June 2002 to December 2007 was made. APBI was delivered with a single-lumen MammoSite balloon-based applicator to a median dose of 34 Gy in 10 fractions over a 5-day period. Tumor coverage and critical organ dosimetry were retrospectively collected on the basis of computed tomography completed for conformance and symmetry. Results: At a median follow-up time of 5.5 years (range, 0-10.0 years), the 5-year and 7-year actuarial incidences of ipsilateral breast control were 98%/98%, of nodal control 99%/98%, and of distant control 99%/99%, respectively. The crude rate of ipsilateral breast recurrence was 2.5% (n=4); of nodal failure, 1.9% (n=3); and of distant failure, 0.6% (n=1). The 5-year and 7-year actuarial overall survival rates were 89%/86%, with breast cancer–specific survival of 100%/99%, respectively. Good to excellent cosmetic outcomes were achieved in 93.4% of patients. Telangiectasia developed in 27% of patients, with 1-year, 3-year, and 5-year actuarial incidence of 7%/24%/33%; skin dose >100% significantly predicted for the development of telangiectasia (50% vs 14%, P<.0001). Conclusions: Long-term single-institution outcomes suggest excellent tumor control, breast cosmesis, and minimal late toxicity. Skin toxicity is a function of skin dose, which may be ameliorated with dosimetric optimization afforded by newer multicatheter brachytherapy applicators and a more rigorous skin dose constraint of ≤100%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Heterogeneity-corrected vs -uncorrected critical structure maximum point doses in breast balloon brachytherapy

Recent studies have reported potentially clinically meaningful dose differences when heterogeneity correction is used in breast balloon brachytherapy. In this study, we report on the relationship between heterogeneity-corrected and -uncorrected doses for 2 commonly used plan evaluation metrics: maximum point dose to skin surface and maximum point dose to ribs. Maximum point doses to skin surface and ribs were calculated using TG-43 and Varian Acuros for 20 patients treated with breast balloon brachytherapy. The results were plotted against each other and fit with a zero-intercept line. Max skin dose (Acuros) = max skin dose (TG-43) ⁎ 0.930 (R{sup 2} = 0.995). The average magnitude of difference from this relationship was 1.1% (max 2.8%). Max rib dose (Acuros) = max rib dose (TG-43) ⁎ 0.955 (R{sup 2} = 0.9995). The average magnitude of difference from this relationship was 0.7% (max 1.6%). Heterogeneity-corrected maximum point doses to the skin surface and ribs were proportional to TG-43-calculated doses. The average deviation from proportionality was 1%. The proportional relationship suggests that a different metric other than maximum point dose may be needed to obtain a clinical advantage from heterogeneity correction. Alternatively, if maximum point dose continues to be used in recommended limits while incorporating heterogeneity correction, institutions without this capability may be able to accurately estimate these doses by use of a scaling factor.

61 RADIATION PROTECTION AND DOSIMETRY↗

Rectal balloon use limits vaginal displacement, rectal dose, and rectal toxicity in patients receiving IMRT for postoperative gynecological malignancies

Pelvic radiotherapy for gynecologic malignancies traditionally used a 4-field box technique. Later trials have shown the feasibility of using intensity-modulated radiotherapy (IMRT) instead. But vaginal movement between fractions is concerning when using IMRT due to greater conformality of the isodose curves to the target and the resulting possibility of missing the target while the vagina is displaced. In this study, we showed that the use of a rectal balloon during treatment can decrease vaginal displacement, limit rectal dose, and limit acute and late toxicities. Little is known regarding the use of a rectal balloon (RB) in treating patients with IMRT in the posthysterectomy setting. We hypothesize that the use of an RB during treatment can limit rectal dose and acute and long-term toxicities, as well as decrease vaginal cuff displacement between fractions. We performed a retrospective review of patients with gynecological malignancies who received postoperative IMRT with the use of an RB from January 1, 2012 to January 1, 2015. Rectal dose constraint was examined as per Radiation Therapy Oncology Group (RTOG) 1203 and 0418. Daily cone beam computed tomography (CT) was performed, and the average (avg) displacement, avg magnitude, and avg magnitude of vector were calculated. Toxicity was reported according to RTOG acute radiation morbidity scoring criteria. Acute toxicity was defined as less than 90 days from the end of radiation treatment. Late toxicity was defined as at least 90 days after completing radiation. Twenty-eight patients with postoperative IMRT with the use of an RB were examined and 23 treatment plans were reviewed. The avg rectal V40 was 39.3% ± 9.0%. V30 was65.1% ± 10.0%. V50 was 0%. Separate cone beam computed tomography (CBCT) images (n = 663) were reviewed. The avg displacement was as follows: superior 0.4 + 2.99 mm, left 0.23 ± 4.97 mm, and anterior 0.16 ± 5.18 mm. The avg magnitude of displacement was superior/inferior 2.22 ± 2.04 mm, laterally 3.41 ± 3.62 mm, and anterior/posterior 3.86 ± 3.45 mm. The avg vector magnitude was 6.60 ± 4.14 mm. For acute gastrointestinal (GI) toxicities, 50% experienced grade 1 toxicities and 18% grade 2 GI toxicities. For acute genitourinary (GU) toxicities, 21% had grade 1 and 18% had grade 2 toxicities. For late GU toxicities, 7% had grade 1 and 4% had grade 2 toxicities. RB for gynecological patients receiving IMRT in the postoperative setting can limit V40 rectal dose and vaginal displacement. Although V30 constraints were not met, patients had limited acute and late toxicities. Further studies are needed to validate these findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Capability Demonstration of a 3D CdZnTe Detector on a High-Altitude Balloon Flight

In collaboration between the University of Michigan and Los Alamos National Laboratory, a 3D position-sensing CdZnTe (CZT) detector prototype was built and integrated into a high-altitude balloon platform to evaluate its performance in a space-like mixed-radiation environment. The detector prototype, Orion Eagle, was designed to operate in near-vacuum environments without any temperature regulation. Orion Eagle was hand-launched from NASA’s Columbia Scientific Balloon Facility (CSBF) at Fort Sumner, NM on September 26, 2021, and successfully operated throughout a 9-hour flight, which reached 38.5 km in altitude. The flight met its objectives, successfully detecting atmospheric gamma rays and galactic cosmic rays, and raising the Technical Readiness Level from 4 to 6 for large-volume 3D CZT detector technology for space applications. Ionization tracks produced by charged particles create spatial signatures in the detector that are distinguishable from discrete gamma-ray interactions. Therefore, the 3D position-sensing capabilities using pixelated electrodes on a CZT detector can help enable discrimination of background charged particles from gamma-ray events without an anticoincidence shield. The potential for background rejection capability, ambient-temperature operation, gamma-ray coded-aperture and Compton imaging, and near High Purity Germanium (HPGe) energy resolution motivate the use of large-volume 3D CZT imaging spectrometers in future space missions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detecting lightning infrasound using a high-altitude balloon

Acoustic waves with a wide range of frequencies are generated by lightning strokes during thunderstorms, including infrasonic waves (0.1 to 20 Hz). The source mechanism for these low frequency acoustic waves is still debated and studies have so far been limited to ground–based instruments. Here we report the first confirmed detection of lightning generated infrasound with acoustic instruments suspended at stratospheric altitudes using a free–flying balloon. We observe high–amplitude signals generated by lightning strokes located within 100 km of the balloon as it flew over the Tasman Sea on 17 May 2016. The signals share many characteristics with waveforms recorded previously by ground–based instruments near thunderstorms. The ability to measure lightning activity with high–altitude infrasound instruments has demonstrated the potential for using these platforms to image the full acoustic wavefield in the atmosphere. In conclusion, it validates the use of these platforms for recording and characterizing infrasonic sources located beyond the detection range of ground–based instruments.

54 ENVIRONMENTAL SCIENCES↗

Simulations of drift resistive ballooning L-mode turbulence in the edge plasma of the DIII-D tokamak

Results from simulations of electromagnetic drift-resistive ballooning turbulence for tokamak edge turbulence in realistic single-null geometry are reported. The calculations are undertaken with the BOUT three-dimensional fluid code that solves Braginskii-based fluid equations [X. Q. Xu and R. H. Cohen, Contrib. Plasma Phys. 36, 158 (1998)]. The simulation setup models L-mode edge plasma parameters in the actual magnetic geometry of the DIII-D tokamak [J. L. Luxon et al., Fusion Sci. Technol. 48, 807 (2002)]. The computations track the development of drift-resistive ballooning turbulence in the edge region to saturation. Fluctuation amplitudes, fluctuation spectra, and particle and thermal fluxes are compared to experimental data near the outer midplane from Langmuir probe and beam-emission-spectroscopy for a few well-characterized L-mode discharges in DIII-D. The simulations are comprised of a suite of runs in which the physics model is varied to include more fluid fields and physics terms. The simulations yield results for fluctuation amplitudes, correlation lengths, particle and energy fluxes, and diffusivities that agree with measurements within an order of magnitude and within factors of 2 or better for some of the data. The agreement of the simulations with the experimental measurements varies with respect to including more physics in the model equations within the suite of models investigated. The simulations show stabilizing effects of sheared E × B poloidal rotation (imposed zonal flow) and of lower edge electron temperature and density.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigation of peeling-ballooning stability prior to transient outbursts accompanying transitions out of H-mode in DIII-D

The H-mode transport barrier allows confinement of roughly twice as much energy as in an L-mode plasma. Termination of H-mode necessarily requires release of this energy, and the timescale of that release is of critical importance for the lifetimes of plasma facing components in next step tokamaks such as ITER. H-L transition sequences in modern tokamaks often begin with a transient outburst which appears to be superficially similar to and has sometimes been referred to as a type-I edge localized mode (ELM). Type-I ELMs have been shown to be consistent with ideal peeling ballooning instability and are characterized by significant (up to ∼50%) reduction of pedestal height on short (∼1 ms) timescales. Knowing whether or not this type of instability is present during H-L back transitions will be important of planning for plasma ramp-down in ITER. This paper presents tests of pre-transition experimental data against ideal peeling-ballooning stability calculations with the ELITE code and supports those results with secondary experiments that together show that the transient associated with the H-L transition is not triggered by the same physics as are type-I ELMs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Telescope performance and image simulations of the balloon-borne coded-mask protoMIRAX experiment

In this work we present the results of imaging simulations performed with the help of the GEANT4 package for the protoMIRAX hard X-ray balloon experiment. The instrumental background was simulated taking into account the various radiation components and their angular dependence, as well as a detailed mass model of the experiment. We modelled the meridian transits of the Crab Nebula and the Galactic Centre (CG) region during balloon flights in Brazil (∼ −23° of latitude and an altitude of ∼40 km) and introduced the correspondent spectra as inputs to the imaging simulations. We present images of the Crab and of three sources in the GC: 1E 1740.7-2942, GRS 1758-258 and GX 1+4. The results show that the protoMIRAX experiment is capable of making spectral and timing observations of bright hard X-ray sources as well as important imaging demonstrations that will contribute to the design of the MIRAX satellite mission.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Benchmark studies of the gyro-Landau-fluid code and gyro-kinetic codes on kinetic ballooning modes

A Gyro-Landau-Fluid (GLF) 3 + 1 model has been recently implemented in BOUT++ framework, which contains full Finite-Larmor-Radius effects, Landau damping, and toroidal resonance [Ma et al., Phys. Plasmas 22, 055903 (2015)]. A linear global beta scan has been conducted using the JET-like circular equilibria (cbm18 series), showing that the unstable modes are kinetic ballooning modes (KBMs). In this work, we use the GYRO code, which is a gyrokinetic continuum code widely used for simulation of the plasma microturbulence, to benchmark with GLF 3 + 1 code on KBMs. To verify our code on the KBM case, we first perform the beta scan based on “Cyclone base case parameter set.” We find that the growth rate is almost the same for two codes, and the KBM mode is further destabilized as beta increases. For JET-like global circular equilibria, as the modes localize in peak pressure gradient region, a linear local beta scan using the same set of equilibria has been performed at this position for comparison. With the drift kinetic electron module in the GYRO code by including small electron-electron collision to damp electron modes, GYRO generated mode structures and parity suggest that they are kinetic ballooning modes, and the growth rate is comparable to the GLF results. However, a radial scan of the pedestal for a particular set of cbm18 equilibria, using GYRO code, shows different trends for the low-n and high-n modes. The low-n modes show that the linear growth rate peaks at peak pressure gradient position as GLF results. However, for high-n modes, the growth rate of the most unstable mode shifts outward to the bottom of pedestal and the real frequency of what was originally the KBMs in ion diamagnetic drift direction steadily approaches and crosses over to the electron diamagnetic drift direction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Poloidal asymmetric flow and current relaxation of ballooned transport during I-phase in ASDEX Upgrade

Turbulence driven poloidal asymmetric parallel flow and current perturbations are studied for tokamak plasmas of circular geometry. Whereas zonal flows can lead to in-out asymmetry of parallel flows and currents via the Pfirsch–Schlüter mechanism, ballooned transport can result in an up-down asymmetry due to the Stringer spin-up mechanism. Measurements of up-down asymmetric parallel current fluctuations occurring during the I-phase in ASDEX Upgrade are not responses to the equilibrium by the Pfirsch–Schlüter current, but can be interpreted as a response to strongly ballooned plasma transport coupled with the Stringer spin-up mechanism. A good agreement of the experimental measured limit-cycle frequencies during I-phase with the Stringer spin-up relaxation frequency is found.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ballooning instability preventing the H-mode access in plasmas with negative triangularity shape on the DIII-D tokamak

Infinite toroidal mode number (n=∞ ) ballooning mode analysis of negative triangularity discharges on DIII-D shows that the access to 2nd stability becomes strongly restricted when the top triangularity decreases even modestly from -0.18 to -0.36. This is observed in experiment to coincide with the suppression of the L-H-transition. Further theoretical analysis with ballooning mode limited pedestals shows that the threshold for opening the 2nd stability access rises from a pedestal temperature of 0.3 keV to 1 keV when the top triangularity is decreased from -0.18 to -0.36 indicating that to access the 2nd stability with the more negative triangular shape would require unrealistically high pedestal temperature. Furthermore, the pedestal predicted by the EPED code agrees with the experimental H-mode profile for the negative triangularity case but in contrast to positive triangular shapes the prediction shows no increase in pedestal height with increasing core pressure when triangularity is negative. This work provides a first model to predict when negative triangularity plasmas can be expected to access the H-mode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗