Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BYPASSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Effect of steady-state pressure distortion on inlet flow to a high-bypass-ratio turbofan engine

Static pressure and total pressure distributions were measured in the inlet duct upstream of the engine inlet and within the fan and compressor of a YTF34 turbofan engine. In addition, the free stream flow angle was measured between the distortion generator and the engine inlet. Distortions were generated using three screen configurations with extents of 90 deg or 180 deg. The screens were mounted on a rotatable screen assembly. Reynolds number index upstream of the distortion device was maintained at 0.5 or 0.2, and engine fan speed corrected to station 2 temperature was maintained at 80 or 90 percent of rated condition (7005 rpm). Flow angle was nearly constant near the distortion device and increased as flow approached the engine inlet. The largest flow angle occurred in the hub region of the engine inlet. Static pressure distortion along the inlet duct increased exponentially as the flow approached the engine. Both static pressure and total pressure distortions were attenuated between engine inlet and compressor exit.

Soeder, R. H.↗

Experiments on high bypass internal mixer nozzle jet noise

Model scale jet noise data are presented for a variety of internal lobed mixer nozzle configurations for take off power settings in a static environment. The results are presented for a 17.5 cm diameter fan nozzle to show the effect on noise levels caused by changes in geometric shape of the internal, or core flow, nozzle. The geometric variables include the lobe discharge angle, the number of lobes, spacing between the center plug and lobe valley, lobe side wall shape and axial contour of the lobes. An annular plug core flow nozzle was also tested and is used as a baseline for comparative purposes. Comparison of data from the internal lobed configurations showed that for comparative effect, in terms of the effect on full scale perceived noise levels, was caused by a change in the lobe discharge angle. The results showed that increasing the discharge angle caused an increase as large as 7 dB in sound pressure levels in the high frequency portion of the spectra. Changes in the other geometric variables cause negligible effects.

Goodykoontz, J. H.↗

Effect of combined pressure and temperature distortion orientation on high-bypass-ratio turbofan engine stability

Total-temperature, static-pressure and total-pressure distributions were measured in the inlet duct upstream of the engine inlet and within the fan and compressor of a YTF34 turbofan engine. Free-stream and boundary layer yaw angle variations were measured between a rotable screen assembly and the engine inlet. Total pressure distortions were generated using three 180 deg extent screens and total temperature distortions were generated using a rotatable hydrogen burner. Reynolds number index upstream of the rotatable screen assembly was maintained at 0.5 (based on the undistorted sectors at station 1, the inlet flow measuring station). The engine mechanical fan speed at sea level condition was rated at 7005 rpm. The engine was tested at a corrected fan speed of 90 percent of rated condition. Yaw angle increased between the rotatable screen assembly and the engine inlet. The largest variation in free-stream and boundary layer yaw angle occurs when the combined distortions are 180 deg out-of-phase. Static-pressure distortion increased exponentially as flow approached the engine. Total-pressure distortions were attenuated between the engine inlet and the compressor exit. Total-temperature distortion persisted through the compressor for all four combined distortions investigated.

Soeder, R. H.↗

Some characteristics of bypass transition in a heated boundary layer

Experimental measurements of both mean and conditionally sampled characteristics of laminar, transitional and low Reynolds number turbulent boundary layers on a heated flat plate are presented. Measurements were obtained in air over a range of freestream turbulence intensities from 0.3 percent to 6 percent with a freestream velocity of 30.5 m/s and zero pressure gradient. Conditional sampling performed in the transitional boundary layers indicate the existence of a near-wall drop in intermittency, especially pronounced at low intermittencies. Nonturbulent intervals were observed to possess large levels of low-frequency unsteadiness, and turbulent intervals had peak intensities as much as 50 percent higher than were measured at fully turbulent stations. Heat transfer results were consistent with results of previous researchers and Reynolds analogy factors were found to be well predicted by laminar and turbulent correlations which accounted for unheated starting length. A small dependence of the turbulent Reynolds analogy factors on freestream turbulence level was observed. Laminar boundary layer spectra indicated selective amplification of unstable frequencies. These instabilities appear to play a dominant role in the transition process only for the lowest freestream turbulence level studied, however.

Sohn, K. H.↗

Some characteristics of bypass transition in a heated boundary layer

Experimental measurements of both mean and conditionally sampled characteristics of laminar, transitional and low Reynolds number turbulent boundary layers on a heated flat plate are presented. Measurements were obtained in air over a range of freestream turbulence intensities from 0.3 percent to 6 percent with a freestream velocity of 30.5 m/s and zero pressure gradient. Conditional sampling performed in the transitional boundary layers indicate the existence of a near-wall drop in intermittency, especially pronounced at low intermittencies. Nonturbulent intervals were observed to possess large levels of low-frequency unsteadiness, and turbulent intervals had peak intensities as much as 50 percent higher than were measured at fully turbulent stations. Heat transfer results were consistent with results of previous researches and Reynolds analogy factors were found to be well predicted by laminar and turbulent correlations which accounted for unheated starting length. A small dependence of the turbulent Reynolds analogy factors on freestream turbulence level was observed. Laminar boundary layer spectra indicated selective amplification of unstable frequencies. These instabilities appear to play a dominant role in the transition process only for the lowest freestream turbulence level studied, however.

Sohn, K. H.↗

H2-fueled high-bypass turbofan

The study developed preliminary design concepts for the exploitation of the properties of LH2 in a turbofan engine intended for air transport use, and showed the benefits which accrue in reduction of aircraf direct operating cost. Design concepts for the engine fuel delivery and control system, including the engine high pressure fuel pump, were developed, and general concept feasibility was shown. For both the engine and the fuel delivery and control system, recommendations were made for the advanced development which is necessary to bring the technology to a state of readiness for design application. The study was of necessity abbreviated in nature: more intensive study of both the engine and fuel delivery and control system is recommended.

Riple, J. C.↗

Ultra high bypass Nacelle aerodynamics inlet flow-through high angle of attack distortion test

A flow-through inlet test program was conducted to evaluate inlet test methods and determine the impact of the fan on inlet separation when operating at large angles of attack. A total of 16 model configurations of approximately 1/6 scale were tested. A comparison of these flow-through results with powered data indicates the presence of the fan increased separation operation 3 degrees to 4 degrees over the flow through inlet. Rods and screens located at the fan face station, that redistribute the flow, achieved simulation of the powered-fan results for separation angle of attack. Concepts to reduce inlet distortion and increase angle of attack capability were also evaluated. Vortex generators located on the inlet surface increased inlet angle of attack capability up to 2 degrees and reduced inlet distortion in the separated region. Finally, a method of simulating the fan/inlet aerodynamic interaction using blockage sizing method has been defined. With this method, a static blockage device used with a flow-through model will approximate the same inlet onset of separation angle of attack and distortion pattern that would be obtained with an inlet model containing a powered fan.

Larkin, Michael J.↗

Interference effects of very high bypass ratio nacelle installations on a low-wing transport

A twin-engine, low-wing transport model, with a supercritical wing designed for a cruise Mach number of 0.77 and a lift coefficient of 0.55 was tested in the 16-Foot Transonic Tunnel at NASA Langley Research Center. The purpose of this test was to compare the wing/nacelle interference effects of superfans (BPR 18) with the interference effects of advanced turbofans (BPR 6). Flow-through nacelles were used. Forces and moments on the complete model were measured using a strain gage balance, and extensive surface static pressure measurements were made on the model's wing, nacelles, and pylons. Results of the investigation indicate that superfan nacelles can be installed with approximately the same drag penalty as conventional turbofan nacelles.

Ingraldi, Anthony M.↗

Application of laminar flow control to high-bypass-ratio turbofan engine nacelles

Recently, the concept of the application of hybrid laminar flow to modern commercial transport aircraft was successfully flight tested on a Boeing 757 aircraft. In this limited demonstration, in which only part of the upper surface of the swept wing was designed for the attainment of laminar flow, significant local drag reduction was measured. This paper addresses the potential application of this technology to laminarize the external surface of large, modern turbofan engine nacelles which may comprise as much as 5-10 percent of the total wetted area of future commercial transports. A hybrid-laminar-flow-control (HLFC) pressure distribution is specified and the corresponding nacelle geometry is computed utilizing a predictor/corrector design method. Linear stability calculations are conducted to provide predictions of the extent of the laminar boundary layer. Performance studies are presented to determine potential benefits in terms of reduced fuel consumption.

Wie, Y. S.↗