Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BOLOMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

First snowflake divertor experiments in MAST-U tokamak

First snowflake (SF) divertor experiments in the MAST-U tokamak demonstrated steady-state snowflake-plus divertor configurations in 450 kA ohmic L-mode plasmas. The SF divertor configuration features a second poloidal field (PF) null in the divertor region close by or overlapping with the main X-point. The resulting low PF region and two additional divertor legs (strike points) may lead to additional power and particle flux sharing via a hypothesized convective cell, and increased plasma-wetted area and radiation. The free-boundary Grad–Shafranov equilibrium code FIESTA was used to design SF configurations with several inter-null distances and orientations. In the experiment, the SF configurations with inter-null distances 0.13–0.20 m and lasting 0.2–0.3 s were obtained. Parallel connection lengths between the midplane and the outer strike point in the SF configurations (evaluated at field lines 1–2 mm from the separatrix in the midplane) were 25–30 m, higher than in the standard divertor (20–25 m) or the Super-X divertor (25 m). Diagnostic measurements highlighted salient SF features. The infra-red video bolometer diagnostic showed that the radiated power peaking in the PF null region was not as pronounces as in the standard divertor. Divertor ion fluxes measured by target Langmuir probes showed increased ion flux in the plate region where a secondary SF strike point landed, concomitantly with the SF formation. These measurements may suggest that some particle and heat redistribution was taking place in the convective SF zone. The first SF experiments provide a basis for future SF studies in MAST-U tokamak with higher input power, improved plasma control and diagnostic measurements, to be compared with the modeling predictions of plasma convective SF mixing and lower density strike point detachment threshold.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Broadband Infrared Carbon Nanotube Linear Photodetector Arrays

Carbon nanotubes (CNTs) possess exceptional optoelectronic properties, including broadband absorption and high absorption coefficients, making them promising candidates for photodetector applications. However, conventional designs often rely on single or aligned nanotubes, which restrict device scalability and require complex fabrication techniques. Here, in this work, we address these limitations by utilizing CNT-suspended solutions to fabricate large-area photodetectors based on CNT networks via vacuum filtration and direct laser scribing. CNT networks are uniformly formed onto low-thermal-conductance polymeric filter papers that serve as substrates and mitigate the need for suspended structures, reducing the fabrication complexity and cost. The CNT films are patterned into single devices and 49-pixel linear arrays by using a laser-cutting process, enabling scalable and cost-effective production. The resulting devices operate as bolometers and exhibit broad spectral sensitivity extending from visible to midwave infrared, showing stable operation at room temperature. We further demonstrate proof-of-concept IR imaging using linear arrays.

IR imaging↗

Planck 2018 results - IV. Diffuse component separation

We present full-sky maps of the cosmic microwave background (CMB) and polarized synchrotron and thermal dust emission, derived from the third set of Planck frequency maps. These products have significantly lower contamination from instrumental systematic effects than previous versions. The methodologies used to derive these maps follow closely those described in earlier papers, adopting four methods (Commander, NILC, SEVEM, and SMICA) to extract the CMB component, as well as three methods (Commander, GNILC, and SMICA) to extract astrophysical components. Our revised CMB temperature maps agree with corresponding products in the Planck 2015 delivery, whereas the polarization maps exhibit significantly lower large-scale power, reflecting the improved data processing described in companion papers; however, the noise properties of the resulting data products are complicated, and the best available end-to-end simulations exhibit relative biases with respect to the data at the few percent level. Using these maps, we are for the first time able to fit the spectral index of thermal dust independently over 3° regions. We derive a conservative estimate of the mean spectral index of polarized thermal dust emission of β d = 1.55 ± 0.05, where the uncertainty marginalizes both over all known systematic uncertainties and different estimation techniques. For polarized synchrotron emission, we find a mean spectral index of β s = -3.1 ± 0.1, consistent with previously reported measurements. We note that the current data processing does not allow for construction of unbiased single-bolometer maps, and this limits our ability to extract CO emission and correlated components. The foreground results for intensity derived in this paper therefore do not supersede corresponding Planck 2015 products. For polarization the new results supersede the corresponding 2015 products in all respects.

79 ASTRONOMY AND ASTROPHYSICS↗

Maximal absorption in ultrathin TiN films for microbolometer applications

Ultrathin light absorbers present a viable route toward improving the specific detectivity and response time of microbolometers. However, for an ultrathin film to absorb light efficiently, the dielectric function of the film and its thickness must satisfy strict requirements. Here we experimentally demonstrate an average absorptance of 48% ± 2.5% in the 8–13 μm (769–1250 cm -1 ) spectral range for 10 nm thick titanium nitride (TiN), a value bordering on the 50% fundamental absorptance limit for a suspended thin film. The heat capacity per unit area of this absorber is only 1.2 × 10 -6 J/K/cm 2 , which is beneficial for improving the response time of a microfabricated bolometer. We also show that a sufficient condition for reaching maximal absorption in an ultrathin film is that ε" $\gg$ |ε'|.

36 MATERIALS SCIENCE↗

Soft x-ray power diagnostics for fusion experiments at NIF, Omega, and Z facilities

Here, in this Review Article, we discuss a range of soft x-ray power diagnostics at inertial confinement fusion (ICF) and pulsed-power fusion facilities. This Review Article describes current hardware and analysis approaches and covers the following methods: x-ray diode arrays, bolometers, transmission grating spectrometers, and associated crystal spectrometers. These systems are fundamental for the diagnosis of ICF experiments, providing a wide range of critical parameters for the evaluation of fusion performance.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-n Rydberg transition spectroscopy for heavy impurity transport studies in W7-X (invited)

Here, we present a novel spectroscopy approach to investigate impurity transport by analyzing line-radiation following high-n Rydberg transitions. While high-n Rydberg states of impurity ions are unlikely to be populated via impact excitation, they can be accessed by charge exchange (CX) reactions along the neutral beams in high-temperature plasmas. Hence, localized radiation of highly ionized impurities, free of passive contributions, can be observed at multiple wavelengths in the visible range. For the analysis and modeling of the observed Rydberg transitions, a technique for calculating effective emission coefficients is presented that can well reproduce the energy dependence seen in datasets available on the OPEN-ADAS database. By using the rate coefficients and comparing modeling results with the new high-n Rydberg CX measurements, impurity transport coefficients are determined with well-documented 2σ confidence intervals for the first time. This demonstrates that high-n Rydberg spectroscopy provides important constraints on the determination of impurity transport coefficients. By additionally considering Bolometer measurements, which provide constraints on the overall impurity emissivity and, therefore, impurity densities, error bars can be reduced even further.

Instruments & Instrumentation↗

Thermal detector for measuring radiation parameters of pulsed lasers and generators of submillimetre and millimetre ranges

A theoretical formula is derived that makes it possible to establish a relationship between the speed and sensitivity of bolometers with geometric and thermophysical parameters of the receiving element and substrate. The result is confirmed by a preliminary (evaluation) experiment. The proposed thermal detectors can record and measure the radiation power of lasers and generators of the submillimetre (SMM) and millimetre (MM) ranges. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Observation of impurity accumulation and its compatibility with high plasma performance in W7-X

At the W7-X stellarator, the bolometer system has measured an intensive radiation zone in the inner plasma region (at a normalized radius $ρ$ ~ 0.3–0.4) in the hydrogen plasma generated by electron cyclotron resonance heating; it differs from the normal plasma radiation distribution with an edge-localized emission zone. Spectroscopic diagnostics have recorded high-Z elements such as iron. This phenomenon happens in the plasma phases after gas supply turn-off, which results in all impurity relevant diagnostic signals increasing for several seconds. Despite the enhancement of the core radiation, the plasma energy confinement is improved. A transport analysis shows that this impurity radiation behavior is associated with a low diffusion coefficient ($D$~ 0.02 m 2 s -1 ) and a reversal of the convection around the radial position of the emission peak, which, under normal conditions, separates the zones of outward convection in the central (|$V$| ~ 0.1 m s -1 ) and inward convection in the outer region (|$V$| ~ 0.3 m s -1 ). An impurity accumulation around this radial position has been identified. The transport coefficients obtained are comparable with the theoretical predictions of collisional impurity transport. In the plasma phases studied, both impurity and energy confinement are enhanced. The mechanism responsible for the improvement is believed to be a reduction of micro-instabilities associated with the observed steepening of the density profile, initiated by a low edge plasma density (<1.0 × 10 19 m -3 ) after switching off the gas fueling. The normalized temperature and density gradients fulfil the condition for the suppression of ITG turbulence.

suppression of ITG turbulence↗

The large scale polarization explorer (LSPE) for CMB measurements: performance forecast

The measurement of the polarization of the Cosmic Microwave Background (CMB) radiation is one of the current frontiers in cosmology. In particular, the detection of the divergence-free component of the polarization field, the B-mode component, reveals the presence of gravitational waves in the early Universe. The detection of such component is at the moment the most promising technique to probe the inflationary theory describing the very early evolution of the Universe. The measurement of the polarization of the Cosmic Microwave Background (CMB) radiation is one of the current frontiers in cosmology. In particular, the detection of the primordial divergence-free component of the polarization field, the B-mode, could reveal the presence of gravitational waves in the early Universe. The detection of such a component is at the moment the most promising technique to probe the inflationary theory describing the very early evolution of the Universe. We present the updated performance forecast of the Large Scale Polarization Explorer (LSPE), a program dedicated to the measurement of the CMB polarization. LSPE is composed of two instruments: LSPE-Strip, a radiometer-based telescope on the ground in Tenerife-Teide observatory, and LSPE-SWIPE (Short-Wavelength Instrument for the Polarization Explorer) a bolometer-based instrument designed to fly on a winter arctic stratospheric long-duration balloon. The program is among the few dedicated to observation of the Northern Hemisphere, while most of the international effort is focused into ground-based observation in the Southern Hemisphere. Measurements are currently scheduled in Winter 2022/23 for LSPE-SWIPE, with a flight duration up to 15 days, and in Summer 2022 with two years observations for LSPE-Strip. In this work, we describe the main features of the two instruments, identifying the most critical aspects of the design, in terms of impact on the performance forecast. We estimate the expected sensitivity of each instrument and propagate their combined observing power to the sensitivity to cosmological parameters, including the effect of scanning strategy, component separation, residual foregrounds and partial sky coverage. We also set requirements on the control of the most critical systematic effects and describe techniques to mitigate their impact. LSPE will reach a sensitivity in tensor-to-scalar ratio of σr < 0.01, set an upper limit r < 0.015 at 95% confidence level, and improve constraints on other cosmological parameters.

79 ASTRONOMY AND ASTROPHYSICS↗

Progress in DIII-D towards validating divertor power exhaust predictions

In this study, UEDGE simulations highlight the role of cross-field drifts on the onset of detached conditions, and new calibrated divertor vacuum ultra violet (VUV) spectroscopy is used to challenge the predictions of radiative constituents in these simulations. UEDGE simulations for DIII-D H-mode plasmas with the open divertor with the ion ∇B-drift towards the X-point show a bifurcated onset of the low field side (LFS) divertor detachment, consistent with experimentally observed step-like detachment onset (Jaervinen A.E. et al 2018 Phys. Rev. Lett. 121 075001). The divertor plasma in the simulations exhibits hysteresis in upstream separatrix density between attached and detached solution branches. Reducing the drift magnitude by a factor of 3 eliminates the step-like detachment onset in the simulations, confirming the strong role of drifts in the bifurcated detachment onset. When measured local plasma densities and temperatures are within proximity of predicted values in the simulations, there is no shortfall of the local emission of the dominant resonant radiating lines. However, the simulations systematically predict a factor of two lower total integrated radiated power than measured by the bolometer with the difference lost through radial heat flow out of the computational domain. Even though there is no shortfall in the emission of the dominant lines, a shortfall of total radiated power can be caused by underpredicted spatial extent of the radiation front, indicating a potential upstream or divertor transport physics origin for the radiation shortfall, or shortfall of radiated power in the spectrum between the dominant lines. In addition to the underpredicted spatial extent, in detached conditions, the simulations overpredict the peak radiation and dominant carbon lines near the X-point, which can be alleviated by manually increasing divertor diffusivity in the simulations, highlighting the ad hoc cross-field transport as one of the key limitations of the predictive capability of these divertor fluid codes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Validation of 3D MHD simulations of Ne/D 2 mixed shattered pellet injection in JET

Nonlinear 3D magnetohydrodynamic (MHD) modeling of shattered pellet injection (SPI) in JET tokamak plasmas is performed with the JOREK code. The study focuses on the validation of simulation result with respect to experimental observations, addressing in particular figures of merit for the efficiency of the SPI, as a technique to mitigate thermal loads by injecting radiative impurities like neon during the thermal quench (TQ) phase of disruptions. A set of JET pulses with neon/deuterium atomic mixture ratio in the shattered pellet varying from 10% to 100% provides the experimental data to be compared with. Simulations using different models for the ablation of solid fragments and the radiation of neon impurities are considered. Synthetic diagnostics are employed for a direct quantitative comparison with key JET diagnostic systems providing in particular radiation, electron temperature and density, and magnetic measurements. 3D radiation structures from MHD simulations are analyzed to estimate the toroidal asymmetry of radiation, which is difficult to measure in JET due to the presence of only two toroidally displaced multi-channel bolometry systems. JOREK simulations show that, before the TQ, the bulk of the radiation is concentrated in a toroidal region enclosing the radiating fragments that is missed by both multi-channel bolometers, suggesting a possible underestimation of the total radiation by such diagnostic systems in the pre-TQ phase. On the other hand, JOREK predicts that during the TQ the radiation becomes more toroidally symmetric, with positive implications for the heat load to plasma facing components.

JOREK↗

First data from the CUPID-Mo neutrinoless double beta decay experiment

The CUPID-Mo experiment is searching for neutrinoless double beta decay in $^{100}$Mo, evaluating the technology of cryogenic scintillating Li$_{2}^{100}$MoO$_4$ detectors for CUPID (CUORE Upgrade with Particle ID). CUPID-Mo detectors feature background suppression using a dual-readout scheme with Li$_{2}$MoO$_4$ crystals complemented by Ge bolometers for light detection. The detection of both heat and scintillation light signals allows the efficient discrimination of $\alpha$ from $\gamma$&$\beta$ events. In this proceedings, we discuss results from the first 2 months of data taking in spring 2019. In addition to an excellent bolometric performance of 6.7$\,$keV (FWHM) at 2615$\,$keV and an $\alpha$ separation of better than 99.9% for all detectors, we report on bulk radiopurity for Th and U. Finally, we interpret the accumulated physics data in terms of a limit of $T_{1/2}^{0\nu}\,> 3\times10^{23}\,$yr for $^{100}$Mo and discuss the sensitivity of CUPID-Mo until the expected end of physics data taking in early 2020.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Pulse shape discrimination in CUPID-Mo using principal component analysis

CUPID-Mo is a cryogenic detector array designed to search for neutrinoless double-beta decay ($0\nu\beta\beta$) of $^{100}$Mo. It uses 20 scintillating $^{100}$Mo-enriched Li$_2$MoO$_4$ bolometers instrumented with Ge light detectors to perform active suppression of $\alpha$ backgrounds, drastically reducing the expected background in the $0\nu\beta\beta$ signal region. As a result, pileup events and small detector instabilities that mimic normal signals become non-negligible potential backgrounds. These types of events can in principle be eliminated based on their signal shapes, which are different from those of regular bolometric pulses. We show that a purely data-driven principal component analysis based approach is able to filter out these anomalous events, without the aid of detector response simulations.

47 OTHER INSTRUMENTATION↗

A first test of CUPID prototypal light detectors with NTD-Ge sensors in a pulse-tube cryostat

CUPID is a next-generation bolometric experiment aiming at searching for neutrinoless double-beta decay with ~250 kg of isotopic mass of 100 Mo. It will operate at ~10 mK in a cryostat currently hosting a similar-scale bolometric array for the CUORE experiment at the Gran Sasso National Laboratory (Italy). CUPID will be based on large-volume scintillating bolometers consisting of 100 Mo-enriched Li 2 MoO 4 crystals, facing thin Ge-wafer-based bolometric light detectors. In the CUPID design, the detector structure is novel and needs to be validated. In particular, the CUORE cryostat presents a high level of mechanical vibrations due to the use of pulse tubes and the effect of vibrations on the detector performance must be investigated. In this paper we report the first test of the CUPID-design bolometric light detectors with NTD-Ge sensors in a dilution refrigerator equipped with a pulse tube in an above-ground lab. Light detectors are characterized in terms of sensitivity, energy resolution, pulse time constants, and noise power spectrum. Despite the challenging noisy environment due to pulse-tube-induced vibrations, we demonstrate that all the four tested light detectors comply with the CUPID goal in terms of intrinsic energy resolution of 100 eV RMS baseline noise. Indeed, we have measured 70–90 eV RMS for the four devices, which show an excellent reproducibility. We have also obtained high energy resolutions at the 356 keV line from a 133 Ba source, as good as Ge semiconductor γ detectors in this energy range.

47 OTHER INSTRUMENTATION↗

Cryogenic light detectors with thermal signal amplification for 0 νββ search experiments

As a step towards the realization of cryogenic-detector experiments to search for neutrinoless double-beta decay (such as CROSS, BINGO, and CUPID), we investigated a batch of 10 Ge light detectors (LDs) assisted by Neganov-Trofimov-Luke (NTL) signal amplification. Each LD was assembled with a large cubic light-emitting crystal (45 mm side) using the recently developed CROSS mechanical structure. The detector array was operated at milli-Kelvin temperatures in a pulse-tube cryostat at the Canfranc underground laboratory in Spain. We achieved good performance with scintillating bolometers from CROSS, made of Li 2 100 MoO 4 crystals and used as reference detectors of the setup, and with all LDs tested (except for a single device that encountered an electronics issue). No leakage current was observed for 8 LDs with an electrode bias up to 100 V. Operating the LDs at an 80 V electrode bias applied in parallel, we obtained a gain of around 9 in the signal-to-noise ratio of these devices, allowing us to achieve a baseline noise RMS of O(10 eV). Thanks to the strong current polarization of the temperature sensors, the time response of the devices was reduced to around half a millisecond in rise time. The achieved performance of the LDs was extrapolated via simulations of pile-up rejection capability for several configurations of the CUPID detector structure. Despite the sub-optimal noise conditions of the LDs (particularly at high frequencies), we demonstrated that the NTL technology provides a viable solution for background reduction in CUPID.

47 OTHER INSTRUMENTATION↗

High-bandwidth frequency domain multiplexed readout of transition-edge sensors for neutrinoless double beta decay searches

The next-generation of cryogenic neutrinoless double-beta decay experiments require increasingly fast readout in order to improve background discrimination. These experiments, operated as cryogenic calorimeters at ∼ 10 mK, are usually read out by high-impedance neutron transmutation doped (NTD) thermistors, which provide good energy resolution, but are limited by ∼ 1 ms response times. Superconducting detectors, such as transition-edge sensors (TESs) with a time resolution of ∼ 100 μs, offer superior timing performance over NTD semiconductor bolometers. To make this technology viable for an application to a thousand or more channels, multiplexed readout is necessary in order to minimize the thermal load and radioactive contamination induced by the readout. Frequency-domain multiplexing readout (fMUX) for TESs, previously developed at Berkeley Lab and McGill University, is currently in use for mm-wave telescopes with detector sampling rates in the order of 100 Hz. We demonstrate a new readout system, based on the McGill/Berkeley digital fMux readout, to satisfy the higher bandwidth and noise requirements of the next generation of TES-instrumented cryogenic calorimeters. Each multiplexing readout module comprises 10 superconducting resonators in the 1–5 MHz range and a DC superconducting quantum interference device (DC-SQUID), interfaced to high-speed field programmable gate array (FPGA)-based electronics for digital signal processing and low-latency SQUID feedback. The new readout samples detectors at 156 kHz, three orders of magnitude faster than its cosmology-oriented predecessor, and demonstrates a stable feedback bandwidth of 3 kHz in a real TES-based system.

47 OTHER INSTRUMENTATION↗

New Limit for Neutrinoless Double-Beta Decay of 100 Mo from the CUPID-Mo Experiment

The CUPID-Mo experiment at the Laboratoire Souterrain de Modane (France) is a demonstrator for CUPID, the next-generation ton-scale cryogenic $0\nu\beta\beta$ experiment. It consists of a 4.2 kg array of 20 enriched Li$_{2}$$^{100}$MoO$_4$ scintillating bolometers to search for the lepton number violating process of $0\nu\beta\beta$ decay in $^{100}$Mo. With more than one year of operation (2.16 kg$\times$yr of physics data), no event in the region of interest and hence no evidence for $0\nu\beta\beta$ is observed. We report a new limit on the half-life of $0\nu\beta\beta$ decay in $^{100}$Mo of $T_{1/2} > 1.5 \times 10^{24}\,$yr at 90 % C.I. The limit corresponds to an effective Majorana neutrino mass $\langle m_{\beta\beta} \rangle$ $<$ (0.3--0.5)$\,$eV, dependent on the nuclear matrix element in the light Majorana neutrino exchange interpretation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ultrathin epitaxial MgB 2 on SiC: Substrate surface-polarity-dependent properties

High-quality, ultrathin superconducting films are required for advanced devices such as hot-electron bolometers, superconducting nanowire single-photon detectors, and quantum applications. Using hybrid physical-chemical vapor deposition, we show that MgB 2 films as thin as 4 nm can be fabricated on the carbon-terminated 6⁢H-SiC (0001) surface with a superconducting transition temperature above 33 K and a rms roughness of 0.7 nm. Remarkably, the film quality is a function of the SiC surface termination, with the C-terminated surface preferred to the Si-terminated surface. To understand the MgB 2 thin film/SiC substrate interactions giving rise to this difference, we characterized the interfacial structures using Rutherford backscattering spectroscopy/channeling, electron-energy-loss spectroscopy, and x-ray photoemission spectroscopy. The MgB 2 /SiC interface structure is complex and different for the two terminations. Both terminations incorporate substantial unintentional oxide layers influencing MgB 2 growth and morphology, but with a different extent, intermixing, and interface chemistry. In this paper, we report measurements of transport, resistivity, and the critical superconducting temperature of MgB 2 /SiC that are different for the two terminations, and they link interfacial structure variations to observed differences. The result shows that the C face of SiC is a preferred substrate for the deposition of ultrathin superconducting MgB 2 films.

36 MATERIALS SCIENCE↗