Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM PROFILES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

A Quantitative Method for In Situ Pump-Beam Metrology in 4D Ultrafast Electron Microscopy

In this work, we report a method for measuring spot size and focusing conditions of the femtosecond (fs) excitation laser in situ at the specimen location in 4D ultrafast electron microscopy (UEM). The method makes use of threshold laser ablation behaviors of thin amorphous carbon membranes. For Gaussian beam profiles and for ablation threshold fluence values, we analytically derive expressions describing the relationship between ablated hole size and the actual laser spot size. Using these expressions, we developed experimental procedures for characterizing the shape and spot size of the pump beam at the specimen. We demonstrate the viability of the approach for incident excitation wavelengths of 343 nm and 515 nm, thus illustrating the applicability of the method to a range of optical wavelengths without modification. Further, we show that by measuring ablated hole size as a function of focusing condition, a full metrological characterization of the Gaussian beam propagation properties can be performed. Finally, we find good agreement for spot sizes determined with this method and with those determined by extrapolation from measurements taken outside the microscope column. Overall, this method is a simple, cost-effective means for accurate and precise determination of key pump-beam parameters in situ at the specimen location in UEM experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Planar Submillimeter-Wave Mixer Technology with Integrated Antenna

High-performance mixers at terahertz frequencies require good matching between the coupling circuits such as antennas and local oscillators and the diode embedding impedance. With the availability of amplifiers at submillimeter wavelengths and the need to have multi-pixel imagers and cameras, planar mixer architecture is required to have an integrated system. An integrated mixer with planar antenna provides a compact and optimized design at terahertz frequencies. Moreover, it leads to a planar architecture that enables efficient interconnect with submillimeter-wave amplifiers. In this architecture, a planar slot antenna is designed on a thin gallium arsenide (GaAs) membrane in such a way that the beam on either side of the membrane is symmetric and has good beam profile with high coupling efficiency. A coplanar waveguide (CPW) coupled Schottky diode mixer is designed and integrated with the antenna. In this architecture, the local oscillator (LO) is coupled through one side of the antenna and the RF from the other side, without requiring any beam sp litters or diplexers. The intermediate frequency (IF) comes out on a 50-ohm CPW line at the edge of the mixer chip, which can be wire-bonded to external circuits. This unique terahertz mixer has an integrated single planar antenna for coupling both the radio frequency (RF) input and LO injection without any diplexer or beamsplitters. The design utilizes novel planar slot antenna architecture on a 3- mthick GaAs membrane. This work is required to enable future multi-pixel terahertz receivers for astrophysics missions, and lightweight and compact receivers for planetary missions to the outer planets in our solar system. Also, this technology can be used in tera hertz radar imaging applications as well as for testing of quantum cascade lasers (QCLs).

Chattopadhyay, Gautam↗

SU-F-T-476: Performance of the AS1200 EPID for Periodic Photon Quality Assurance

Purpose: To assess the dosimetric performance of a new amorphous silicon flat-panel electronic portal imaging device (EPID) suitable for high-intensity, flattening-filter-free delivery mode. Methods: An EPID-based QA suite was created with automation to periodically monitor photon central-axis output and two-dimensional beam profile constancy as a function of gantry angle and dose-rate. A Varian TrueBeamTM linear accelerator installed with Developer Mode was used to customize and deliver XML script routines for the QA suite using the dosimetry mode image acquisition for an aS1200 EPID. Automatic post-processing software was developed to analyze the resulting DICOM images. Results: The EPID was used to monitor photon beam output constancy (central-axis), flatness, and symmetry over a period of 10 months for four photon beam energies (6x, 15x, 6xFFF, and 10xFFF). EPID results were consistent to those measured with a standard daily QA check device. At the four cardinal gantry angles, the standard deviation of the EPID central-axis output was <0.5%. Likewise, EPID measurements were independent for the wide range of dose rates (including up to 2400 mu/min for 10xFFF) studied with a standard deviation of <0.8% relative to the nominal dose rate for each energy. Also, profile constancy and field size measurements showed good agreement with the reference acquisition of 0° gantry angle and nominal dose rate. XML script files were also tested for MU linearity and picket-fence delivery. Using Developer Mode, the test suite was delivered in <60 minutes for all 4 photon energies with 4 dose rates per energy and 5 picket-fence acquisitions. Conclusion: Dosimetry image acquisition using a new EPID was found to be accurate for standard and high-intensity photon beams over a broad range of dose rates over 10 months. Developer Mode provided an efficient platform to customize the EPID acquisitions by using custom script files which significantly reduced the time. This work was funded in part by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Ultrasonic Bessel beam generation from radial modes of piezoelectric discs

We present comprehensive analytical and experimental investigations on ultrasonic Bessel beam generation from radial modes of piezoelectric disc transducers. The Bessel vibration pattern of the radial modes was experimentally measured using Laser Doppler Vibrometry and was found to be in very good agreement with those obtained from numerical simulations. Ultrasonic beam profiles from the first four radial modes of the piezoelectric disc were measured using a hydrophone in a water tank. The results obtained from the experimental scans were compared to the predictions from an analytical model and were found to be in very good agreement. Also, the Bessel beams generated from the radial modes (except the first) of the piezoelectric discs were found to have narrow beam width for the central lobe compared to those from an ideal piston source of same size. The proposed approach of using radial modes for Bessel beam generation finds applications in imaging, acoustic particle manipulation and trapping, and acousto-optics.

47 OTHER INSTRUMENTATION↗

Single-mode Fiber and Few-Mode Fiber Photonic Lanterns Performance Evaluated for Use in a Scalable Real-Time Photon Counting Ground Receiver

Photonic lanterns provide an efficient way of coupling light from a single large-core fiber to multiple small-core fibers. This capability is of interest for space to ground communication applications. In these applications, the optical ground receivers require high-efficiency coupling from an atmospherically distorted focus spot to multiple fiber coupled single pixel super-conducting nanowire detectors. This paper will explore the use of photonic lanterns in a real-time ground receiver that is scalable and constructed with commercial parts. The number of small-core fibers that make a photonic lantern determines the number of spatial modes that they couple. For instance, lanterns made with n number of single-mode fibers can couple n number of spatial modes. Although the laser transmitted from a spacecraft originates as a Gaussian shape, the atmosphere distorts the beam profile by scattering energy into higher-order spatial modes. Therefore, if a ground receiver is sized for a target data rate with n number of detectors, the corresponding lantern made with single-mode fibers will couple n number of spatial modes. The energy of the transmitted beam scattered into spatial modes higher than n will be lost. This paper shows this loss may be reduced by making lanterns with few-mode fibers instead of single-mode fibers, increasing the number of spatial modes that can be coupled and therefore increasing the coupling efficiency to single pixel, single photon detectors. The free space to fiber coupling efficiency of these two types of photonic lanterns are compared over a range of the free-space coupling numerical apertures and mode field diameters. Results indicate the few mode fiber lantern has higher coupling efficiency for telescopes with longer focal lengths under higher turbulent conditions. Also presented is analysis of the jitter added to the system by the lanterns, showing the few-mode fiber photonic lantern adds more jitter than the single-mode fiber lantern, but less than a multimode fiber.

photon counting↗

Multipurpose epithermal neutron beam on new research station at MARIA research reactor in Swierk-Poland

MARIA reactor is an open-pool research reactor what gives the chance to install uranium fission converter on the periphery of the core. It could be installed far enough not to induce reactivity of the core but close enough to produce high flux of fast neutrons. Special design of the converter is now under construction. It is planned to set the research stand based on such uranium converter in the near future: in 2015 MARIA reactor infrastructure should be ready (preparation started in 2013), in 2016 the neutron beam starts and in 2017 opening the stand for material and biological research or for medical training concerning BNCT. Unused for many years, horizontal channel number H2 at MARIA research rector in Poland, is going to be prepared as a part of unique stand. The characteristics of the neutron beam will be significant advantage of the facility. High flux of neutrons at the level of 2x10{sup 9} cm{sup -2}s{sup -1} will be obtainable by uranium neutron converter located 90 cm far from the reactor core fuel elements (still inside reactor core basket between so called core reflectors). Due to reaction of core neutrons with converter U{sub 3}Si{sub 2} material it will produce high flux of fast neutrons. After conversion neutrons will be collimated and moderated in the channel by special set of filters and moderators. At the end of H2 channel i.e. at the entrance to the research room neutron energy will be in the epithermal energy range with neutron intensity at least at the level required for BNCT (2x10{sup 9} cm{sup -2}s{sup -1}). For other purposes density of the neutron flux could be smaller. The possibility to change type and amount of installed filters/moderators which enables getting different properties of the beam (neutron energy spectrum, neutron-gamma ratio and beam profile and shape) is taken into account. H2 channel is located in separate room which is adjacent to two other empty rooms under the preparation for research laboratories (200 m2). It is planned to create fully equipped complex facility possible to perform various experiments on the intensive neutron beam. Epithermal neutron beam enables development across the full spectrum of materials research for example shielding concrete tests or electronic devices construction improvement. Due to recent reports on the construction of the accelerator for the Boron Neutron Capture Therapy (BNCT) it has the opportunity to become useful and successful method in the fight against brain and other types of cancers not treated with well known medical methods. In Europe there is no such epithermal neutron source which could be used throughout the year for training and research for scientist working on BNCT what makes the stand unique in Europe. Also our research group which specializes in mixed radiation dosimetry around nuclear and medical facilities would be able to carry out research on new detectors and methods of measurements for radiological protection and in-beam (therapeutic) dosimetry. Another group of scientists from National Centre for Nuclear Research, where MARIA research reactor is located, is involved in research of gamma detector systems. There is an idea to develop Prompt-gamma Single Photon Emission Computed Tomography (Pg- SPECT). This method could be used as imaging system for compounds emitting gamma rays after nuclear reaction with thermal neutrons e.g. for boron concentration in BNCT. Inside the room, where H2 channel is located, there is another horizontal channel - H1 which is also unused. Simultaneously with the construction of the H2 stand it will be possible to create special pneumatic horizontal mail inside the H1 channel for irradiation material samples in the vicinity of the core i.e. in the distal part of the H1 channel. It might expand the scope of research at the planned neutron station. Secondly it is planned to equip both stands with moveable positioning system, video system and facilities to perform animal experiments (anaesthesia, vital signs control, imaging devices, positioning). These all above make constructed station unique in the world (uranium fission converter-based beam) and the only one of such intense neutron beam in the Europe. Moreover implementation of the station would allow the development of research on a number of issues for researchers from all over the Europe. One of very important advantages of the station is undisturbed exploitation of the reactor and other vertical and horizontal channels. MARIA reactor operates 6000 hours per year and that amount of time will be achievable for research on the neutron station. It have to be underlined that new neutron station will work parallel to all another ventures. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Mitigation of cross-beam energy transfer in symmetric implosions on OMEGA using wavelength detuning

The effects of frequency detuning laser beams in direct-drive symmetric implosions were investigated with a 3-D cross-beam energy transfer (CBET) model. Our model shows that interactions between beams with relative angles between 45° and 90° are most significant for CBET in OMEGA direct-drive implosions. There is no net exchange in power between beams but there is significant redistribution of power from the ingoing central portion of the beam profile to the outgoing edge as it is exiting the plasma, reducing the total absorbed power. Furthermore, redistribution of laser power because of CBET increases the root-mean-square (rms) absorption nonuniformity by an order of magnitude. CBET mitigation by shifting relative wavelengths of three groups of laser beams fed by each of the different beamlines was modeled. At an on-target wavelength shift of Δλ ~ 10 Å, the total laser absorption was maximized, and the rms absorption nonuniformity was near minimum. In order to completely decouple the three groups of beams from each other requires wavelength shifts Δλ > 30 Å.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A spatial beam property analyzer based on dispersive crystal diffraction for low-emittance X-ray light sources

Abstract The advent of low-emittance synchrotron X-ray sources and free-electron lasers urges the development of novel diagnostic techniques for measuring and monitoring the spatial source properties, especially the source sizes. This work introduces an X-ray beam property analyzer based on a multi-crystal diffraction geometry, including a crystal-based monochromator and a Laue crystal in a dispersive setting to the monochromator. By measuring the flat beam and the transmitted beam profiles, the system can provide a simultaneous high-sensitivity characterization of the source size, divergence, position, and angle in the diffraction plane of the multi-crystal system. Detailed theoretical modeling predicts the system’s feasibility as a versatile characterization tool for monitoring the X-ray source and beam properties. The experimental validation was conducted at a bending magnet beamline at the Swiss Light Source by varying the machine parameters. A measurement sensitivity of less than 10% of a source size of around 12 µm is demonstrated. The proposed system offers a compact setup with simple X-ray optics and can also be utilized for monitoring the electron source.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the muon spin precession frequency using the straw tracking detectors at the Fermilab Muon g-2 experiment

The measurement of the anomalous magnetic dipole moment of the muon ($a_{\mu}$) has long stood as an excellent precision test of the Standard Model (SM). The Fermilab Muon g-2 experiment has recently finished data-taking and in July 2023 published its latest determination of $a_\mu$ with a world-leading precision of 0.2\,ppm. In this publication, it surpassed the systematic uncertainty goal defined in the TDR. The analyses of a dataset approximately four times larger than this recent publication is now underway. The principle measurement of the Muon g-2 experiment measures $a_{\mu}$ by taking the ratio of two frequencies; the anomalous precession frequency ($\omega_a$) and the muon-weighted magnetic field of the experiment's storage ring measured from the precession frequency of protons in water using nuclear magnetic resonance (NMR) probes. In all publications to date, $\omega_a$ has been determined using energy deposits in the 24 calorimeters. However, the Fermilab experiment has t wo straw tracker detectors measuring the time and momentum of charged particles which can in principle also be used to to measure $\omega_a$ and such a measurement can provide an invaluable cross-check of the calorimeter result with different, and reduced, systematic uncertainties. This thesis presents the first (blinded) determination of $\omega_a$ using just charged tracks from the straw tracking detectors as opposed to calorimeter energy deposits. This analysis was undertaken using the Run-2/3 dataset which represents approximately 25\% of the final dataset. A total uncertainty of 2.19\,ppm on $\omega_a$ was obtained which is dominated by the statistical uncertainty of 2.16\,ppm. Additionally two new methodologies important to the analysis of the straw tracking data have been developed: one to better determine the track arrival time ($t_0$) and one to determine the level of pileup in the tracking detectors. The new $t_0$ algorithm which incorporates angular information improves t he resolution on the determination of the $t_0$ by a factor of two and results in 19\% more tracks being successfully reconstructed. The data from the trackers is also used to determine the beam profile that weights the magnetic field in the determination of $a_\mu$ and in determining several of the systematic uncertainties in the calorimeter-based $\omega_a$ analysis. A detailed study of the impact of the internal alignment of the tracker, the $t_0$ and pileup on the determination of the beam position was undertaken and propagated through to an uncertainty in the $\omega_a$ determination. These uncertainties were used in the Fermilab Muon g-2 experiment's recent publication in Phys. Rev. Lett.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Convergent laser beam shapes: Unveiling the dynamics of Laser-induced elastic waves in composite materials

Overcoming the low signal-to-noise ratio (SNR) in laser ultrasonic testing of composite materials remains a significant challenge. Current efforts focus on enhancing SNR by inserting more energy into the material through temporal and/or spatial modulation of the laser beam. However, potential SNR improvements through wave convergence and wave energy manipulation have been overlooked. This paper addresses this gap by demonstrating the convergence of different wave types to a designated point and by showing the feasibility of directing absorbed laser energy into a specific wave type through spatial modulation of the laser beam. To achieve this, mathematical expressions for the convergent laser beams are derived. Various laser beam profiles are then introduced to the thermoelastic equations and solved using the finite element method. The sample under investigation is a transversely isotropic unidirectional carbon fiber reinforced plastic, characterized by anisotropic thermal expansion coefficients and thermal conductivities. Results reveal pronounced convergence of the intended wave type at the center due to laser beam shaping. This study showcases the ability to direct absorbed laser energy toward a specific wave type through spatial modulation of the laser beam and highlights the role of material anisotropy in energy focusing.

composite materials↗

Radiation-damage investigation of a DNA 16-mer

In macromolecular crystallography, a great deal of effort has been invested in understanding radiation-damage progression. While the sensitivity of protein crystals has been well characterized, crystals of DNA and of DNA–protein complexes have not thus far been studied as thoroughly. Here, a systematic investigation of radiation damage to a crystal of a DNA 16-mer diffracting to 1.8 Å resolution and held at 100 K, up to an absorbed dose of 45 MGy, is reported. The RIDL ( Radiation-Induced Density Loss ) automated computational tool was used for electron-density analysis. Both the global and specific damage to the DNA crystal as a function of dose were monitored, following careful calibration of the X-ray flux and beam profile. The DNA crystal was found to be fairly radiation insensitive to both global and specific damage, with half of the initial diffraction intensity being lost at an absorbed average diffraction-weighted dose, D 1/2 , of 19 MGy, compared with 9 MGy for chicken egg-white lysozyme crystals under the same beam conditions but at the higher resolution of 1.4 Å. The coefficient of sensitivity of the DNA crystal was 0.014 Å 2 MGy -1 , which is similar to that observed for proteins. These results imply that the significantly greater radiation hardness of DNA and RNA compared with protein observed in a DNA–protein complex and an RNA–protein complex could be due to scavenging action by the protein, thereby protecting the DNA and RNA in these studies. In terms of specific damage, the regions of DNA that were found to be sensitive were those associated with some of the bound calcium ions sequestered from the crystallization buffer. In contrast, moieties farther from these sites showed only small changes even at higher doses.

Instruments & Instrumentation↗

FPGA-Based Spill Regulation System for the Muon Delivery Ring at Fermilab

The Muon to Electron Experiment (Mu2e) requires a uniform beam profile from the Muon Delivery Ring to meet their experimental needs. A specialized Spill Regulation System (SRS) has been developed to help achieve consistent spill uniformity. The system is based on a custom-designed carrier board featuring an Arria 10 SoC, capable of executing real-time feedback control. The FPGA processes beam pulses of approximately 200 ns every 1.695 $μ$s, allowing for continuous monitoring of the extracted spill intensity through fast bunch integration. The system directly controls three quadrupole magnets, which work in conjunction with sextupole magnets to achieve third-order resonant extraction. Furthermore, the board interfaces with Fermilab's Accelerator Control Network (ACNET), enabling operators to modify spill regulation settings in real-time via the control network while providing diagnostic waveforms. These waveforms help operators monitor the process and fine-tune the feedback mechanisms. This paper presents an overview of the board's architecture and its initial progress toward regulating beam extraction. This initial version of the regulation system aims to evaluate baseline performance to inform future system improvements.

Berlioz, J. R. [Fermilab]↗

FPGA-Based Spill Regulation System for the Muon Delivery Ring at Fermilab

The Muon to Electron Experiment (\acrshort{Mu2e}) requires a uniform beam profile from the Muon Delivery Ring to meet their experimental needs. A specialized Spill Regulation System (\acrshort{SRS}) has been developed to help achieve consistent spill uniformity. The system is based on a custom-designed carrier board featuring an Arria 10 SoC, capable of executing real-time feedback control. The FPGA processes beam pulses of approximately 200 ns every 1.695 microseconds, allowing for continuous monitoring of the extracted spill intensity through fast bunch integration. The system directly controls three quadrupole magnets, which work in conjunction with sextupole magnets to achieve third-order resonant extraction. Furthermore, the board interfaces with Fermilab s Accelerator Control Network (ACNET), enabling operators to modify spill regulation settings in real-time via the control network while providing diagnostic waveforms. These waveforms help operators monitor the process and fine-tune the feedback mechanisms. This paper presents an overview of the board's architecture and its initial progress toward regulating beam extraction. This initial version of the regulation system aims to evaluate baseline performance to inform future system improvements.

Berlioz, Jose Rene [Fermilab]↗

A holistic approach to the optimization of neutron beam transport at the LANSCE facility

An advanced neutron beam collimation system has been developed as part of an effort to optimize neutron beam transport at the Weapons Neutron Research (WNR) Facility, located within the Los Alamos Neutron Science Center (LANSCE). The goal of this work was to develop and demonstrate techniques to tailor neutron delivery in order to provide maximum available flux on sample with a specific beam profile, while simultaneously reducing unwanted background. A holistic approach was taken, upgrading the facility spallation target, facility metrology infrastructure, and flight path shutter insert to support the implementation of this advanced collimation system. Here, modern instruments and software were employed to conduct facility surveys, characterization of as-built geometry of critical components, 3D ray tracing and neutron transport calculations. Beam images and flux measurements were acquired after installation to evaluate the performance of the collimation system and to demonstrate consistent agreement with MCNP simulations which showed an 87% increase of flux on sample while providing suppression of background neutron impingement on the sample frame by 10 3 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hadron Beam Monitor Design with Gas-Filled RF Resonators in Intense Neutrino Source

For the future Long Baseline Neutrino Facility at Fermilab, a new radiation-robust hadron beam profile monitor has been proposed consisting of an interface of gas-filled radiofrequency cavity detectors in the backward region of the LBNF decay pipe. A tailored monitor layout will be used along with the new RF instrumentation. Proposed designs for the detector configuration include a variety of radially symmetric arrangements of RF resonators located at the position of maximum gradient in the beam distribution across the monitor. Until the final detector cavities are available, a prototype tunable Q-factor RF cavity will provide functional emulation for studies of the monitor layout configurations presented here.

43 PARTICLE ACCELERATORS↗

New Submount Requirement of Conductively Cooled Laser Diodes for Lidar Applications

New submount technology is essential for the development of conductively cooled high power diode laser. The simulation and experimental results indicate that thermal conductivity of submount for high power laser-diode must be at least 600 W/m/k or higher for stable operation. We have simulated several theoretical thermal model based on new submount designs and characterized high power diode lasers to determine temperature effects on the performances of laser diodes. The characterization system measures the beam power, output beam profile, temperature distribution, and spectroscopic property of high power diode laser. The characterization system is composed of four main parts: an infrared imaging camera, a CCD camera, a monochromator, and a power meter. Thermal characteristics of two commercial-grade CW 20-W diode laser bars with open heat-sink type were determined with respect to the line shift of emission spectra and beam power stability. The center wavelength of laser emission has a tendency to shift toward longer wavelength as the driving current and heat sink temperature are increased. The increase of heat sink temperature decreases the output power of the laser bar too. Such results lay the guidelines for the design of new submount for high power laser-diodes.

Mo, S. Y.↗

The chromosphere of VV cephei and the distribution of circumstellar dust around red giants and supergiants

The work on this project has followed two separate paths of inquiry. The first project was entitled 'the Chromosphere of VV Cephei.' The examination of the archival spectra revealed significant changes in the spectra. Therefore, we obtained additional observing time with IUE to monitor the system during the summer of 1991. Short-term changes continue to be seen in both the overall spectrum and individual line profiles. Work continues on this object. The second project was entitled 'the Distribution of Circumstellar Dust around Red Giants and Supergiants.' A number of cool evolved stars are surrounded by dust shells of sufficient angular size as to appear extended in the IRAS survey data. The aim of this project has been to convolve the predictions of the flux distribution from model dust shells with the IRAS beam profiles in order to reproduce the observed IRAS scans. At the time of the last status report, the cross-scan profiles of the IRAS detectors had just been added to the modeling procedure. For scans in which the star passed near the detector center, there was no significant variation in predicted scan profile for different detectors. Scans in which the detector did not pass over the bright central star had been anticipated to be particularly useful in determining the dust distribution; however, significant differences in the predicted scan profiles were seen for different detector profiles. For this reason, and due to the cross-talk effects discussed in the previous status report, further work on the scans not including a central star has been postponed in favor of further analysis of scans passing over the central star.

Bauer, Wendy Hagen↗

SU-E-T-382: Influence of Compton Currents On Profile Measurements in Small- Volume Ion Chambers

Purpose: Ionization chambers in electron radiation fields are known to exhibit polarity effects due to Compton currents. Previously we have presented a unique manifestation of this effect observed with a microionization chamber. We have expanded that investigation to include three micro-ionization chambers commonly used in radiation therapy. The purpose of this project is to determine what factors influence this polarity effect for micro-chambers and how it might be mitigated. Methods: Three chambers were utilized: a PTW 31016, an Exradin A-16, and an Exradin A- 26. Beam profile scans were obtained on a Varian TrueBeam linear accelerator in combination with a Wellhofer water phantom for 6, 9, and 12 MeV electrons. Profiles were obtained parallel and perpendicular to the chamber's long axis, with both positive and negative collecting bias. Profiles were obtained with various chamber components shielded by 5 mm of Pb at 6 MeV to determine their relative contributions to this polarity effect. Results: The polarity effect was observed for all three chambers, and the ratio of the polarity effect for the Exradin chambers is proportional to the ratio of chamber volumes. Shielding the stem of both Exradin chambers diminished, but did not remove the polarity effect. However, they demonstrated no out-of-field effect when the cable was shielded with Pb. The PTW chamber demonstrated a significantly reduced polarity effect without any shielding despite its comparable volume with the A-26. Conclusions: The sensitive volume of these micro-chambers is relatively insensitive to collecting polarity. However, charge deposition within the cable can dramatically alter measured ionization profiles. This is demonstrated by the removal of the out-of-field ionization when the cable is shielded for the Exradin chambers. We strongly recommend analyzing any polarity dependence for small-volume chambers used in characterization of electron fields.

07 ISOTOPE AND RADIATION SOURCES↗