Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Alternative Identifiers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

The liquid rocket booster and its potential for the STS

Results of the liquid rocket booster study initiated by NASA to define an alternative to solid rocket boosters, are presented. The prime study contractors, Martin Marietta Corporation and General Dynamics, have identified liquid rocket booster configurations that can increase shuttle performance to 70 klb. These boosters will provide improved reliability, hold down, verification prior to vehicle release, engine-out and abort capabilities. Phasing of these boosters into Space Transportation System (STS) operations without adversely affecting flight rate is described.

Space Shuttle↗

New approaches to NASA ground data systems

This paper discusses an exploration of approaches to providing ground data system support by NASA/Goddard Space Flight Center for scientific missions. Two architecture concepts are identified to provide full support using a mission specific instantiation concept, with distributed client-server architecture. The alternatives are assessed for impact to operations, and for hardware and software sizing. Evaluation benefits and risks is also provided.

Stottlemyer, A. R.↗

Supplier's Status for Critical Solid Propellants, Explosive, and Pyrotechnic Ingredients

In the early 1970's a program was initiated at the Naval Surface Warfare Center/Indian Head Division (NSWC/IHDIV) to address the well-known problems associated with availability and suppliers of critical ingredients. These critical ingredients are necessary for preparation of solid propellants and explosives manufactured by the Navy. The objective of the program was to identify primary and secondary (or back-up) vendor information for these critical ingredients, and to develop suitable alternative materials if an ingredient is unavailable. In 1992 NSWC/IHDIV funded Chemical Propulsion Information Agency (CPIA) under a Technical Area Task (TAT) to expedite the task of creating a database listing critical ingredients used to manufacture Navy propellant and explosives based on known formulation quantities. Under this task CPIA provided employees that were 100 percent dedicated to the task of obtaining critical ingredient suppliers information, selecting the software and designing the interface between the computer program and the database users. TAT objectives included creating the Explosive Ingredients Source Database (EISD) for Propellant, Explosive and Pyrotechnic (PEP) critical elements. The goal was to create a readily accessible database, to provide users a quick-view summary of critical ingredient supplier's information and create a centralized archive that CPIA would update and distribute. EISD funding ended in 1996. At that time, the database entries included 53 formulations and 108 critical used to manufacture Navy propellant and explosives. CPIA turned the database tasking back over to NSWC/IHDIV to maintain and distribute at their discretion. Due to significant interest in propellant/explosives critical ingredients suppliers' status, the Propellant Development and Characterization Subcommittee (PDCS) approached the JANNAF Executive committee (EC) for authorization to continue the critical ingredient database work. In 1999, JANNAF EC approved the PDCS panel task. This paper is designed to emphasize the necessity of maintaining a JANNAF community supported database, which monitors PEP critical ingredient suppliers' status. The final product of this task is a user friendly, searchable database that provides a quick-view summary of critical ingredient supplier's information. This database must be designed to serve the needs of JANNAF and the propellant and energetic commercial manufacturing community as well. This paper provides a summary of the type of information to archive each critical ingredient.

Sims, B. L.↗

Centrosome and microtubule instability in aging Drosophila cells

Several cytoskeletal changes are associated with aging which includes alterations in muscle structure leading to muscular atrophy, and weakening of the microtubule network which affects cellular secretion and maintenance of cell shape. Weakening of the microtubule network during meiosis in aging oocytes can result in aneuploidy or trisomic zygotes with increasing maternal age. Imbalances of cytoskeletal organization can lead to disease such as Alzheimer's, muscular disorders, and cancer. Because many cytoskeletal diseases are related to age we investigated the effects of aging on microtubule organization in cell cultures of the Drosophila cell model system (Schneider S-1 and Kc23 cell lines). This cell model is increasingly being used as an alternative system to mammalian cell cultures. Drosophila cells are amenable to genetic manipulations and can be used to identify and manipulate genes which are involved in the aging processes. Immunofluorescence, scanning, and transmission electron microscopy were employed for the analysis of microtubule organizing centers (centrosomes) and microtubules at various times after subculturing cells in fresh medium. Our results reveal that centrosomes and the microtubule network becomes significantly affected in aging cells after 5 days of subculture. At 5-14 days of subculture, 1% abnormal out of 3% mitoses were noted which were clearly distinguishable from freshly subcultured control cells in which 3% of cells undergo normal mitosis with bipolar configurations. Microtubules are also affected in the midbody during cell division. The midbody in aging cells becomes up to 10 times longer when compared with midbodies in freshly subcultured cells. During interphase, microtubules are often disrupted and disorganized, which may indicate improper function related to transport of cell organelles along microtubules. These results are likely to help explain some cytoskeletal disorders and diseases related to aging.

Non-NASA Center↗

Monitoring of Ionic Silver Biocide with Capacitively-Coupled Contactless Conductivity Detection (C4D)

Monitoring of biocide dosing in spacecraft potable water systems is desirable to ensure dosing system operation and resultant microbial control. Electrolytic conductivity is linearly related to the concentration ionic silver (Ag+, the baseline biocide for future NASA missions) chemically dosed into highly purified water, and could serve as a proxy measurement. Traditional conductivity cells rely on immersed metal or graphite electrodes, which may potentially be subject to significant current-induced or auto-galvanic deposition of Ag+. Furthermore, oxide fouling may potentially induce measurement errors. Capacitively-coupled contactless conductivity detection (C4D) is a promising alternative. C4D uses electrodes placed outside an inert, non-conductive flow path, potentially mitigating such problems. We identified and purchased a commercial C4D system with claimed performance (conductivity range: 20 nS/cm to 4 µS/cm) appropriate for this application. We characterized the instrument’s performance with conductivity standards and Ag+ solutions. We began investigations considering practical and long-term detector operation, including potential current-induced deposition of conductive deposits at the tubing wall. In addition, we designed a side-stream flow system to provide liquid flow through the narrow tubing (1/16” outer diameter) required by the detector and characterized the performance of the combined C4D detector/flow system. Finally, we completed theoretical modeling of expected conductivity change with multiple dosing techniques and water chemistries.

Lance Dean Delzeit↗

Liquid Rocket Booster (LRB) for the Space Transportation System (STS) systems study. Volume 1: Executive summary

The feasibility of replacing the Space Transportation System (STS) Solid Rocket Boosters (SRBs) with Liquid Rocket Boosters (LRBs) was studied. Feasibility required acceptable technical risk, program costs, and a program plan which supports STS requirements. Three major goals were identified to direct booster design and operation: increased STS safety and reliability; STS/LRB integration with minimum impact; and increased STS performance. Two booster engine designs were studied. The first engine design was a turbopump-fed engine with state-of-the-art design, and the second was a pressure-fed engine which might provide a lower cost alternative to the pump-fed concept. Both booster concepts were carried through to completion of conceptual design and all system impacts and program costs were identified. Applications for LRB use in the Advanced Launch System (ALS) program were studied using the pump-fed LRB baseline concept and variations on the baseline concept. Support for the Pressure-Fed Booster Test Bed (PFBTB) included test program planning and costs and technical support.

Source record↗

The Role of (Delta)C-13 in the Search for Reduced Organics on the Surface of Mars

The capabilities of the Sample Analysis at Mars (SAM) instrument suite on the Mars Science Laboratory (MSL) to detect trace amounts of organic carbon compounds are unprecedented, and MSL may be the first mission to reveal the presence of organic carbon on Mars. The search for reduced organic carbon on Mars is inextricably tied to: a) the preservation potential of the environment from which we take a solid sample, and b) the evolved gas analysis (EGA) techniques used by SAM to release volatiles from this solid sample. Several prospective targets have been identified for sample analysis at Gale Crater. Stratigraphic sequences of phyllosilicates and sulfates at Gale are thought to represent a period of global climate transition from a moderate pH lacustrine environment to an evaporitic environment, both of which could sequester organic carbon (Thomson et al. 2011). The sediment mound in Gale Crater contains a range of lithologies suggesting changes in redox conditions, and evidence of both lacustrine and fluvial depositional processes, which may have transported organic carbon from the layer in which it formed and resulted in its preservation elsewhere within the crater (Anderson and Bell, 2010). Inverted channel fills suggest erosion resistant material that could serve to preserve organics originally deposited in a low energy aqueous environment. The lithology sampled will affect not only the preservation of organics, but also our ability to detect organics during our evolved gas analysis, based on the sample matrix. For example, reduced organics may be trapped in the mineral structure, and thermal evolution of these organics will occur during thermal decomposition of the host mineral. If organics are occluded in minerals that have very high thermal decomposition temperatures, they may be, in effect, "too well preserved," and difficult to detect during EGA. Alternatively, the possible presence of perchlorate, or other strong oxidants in surface regolith, may result in destruction of structural information identifying organic molecules before reaching the QMS on SAM via oxidation to C02 during heating. If this is the case, the stable carbon isotopic composition (delta 13C) of the C02 evolved and measured by the Tunable Laser Spectrometer (TLS) on SAM may help identify the presence of organics. On Earth, biological activity can cause large fractionations of 13C/12C, which can preserved in sedimentary deposits and distinguish the organic products of biotic processes from inorganic atmospheric and geological reservoirs. It is plausible that similar fractionations could occur on Mars and be preserved in reduced organic matter in sediments. Bulk delta 13C measurements alone may not reveal a signature of trace organic carbon that may be present along with inorganic carbon. If both organic and inorganic carbon compounds are present, it may be possible to detect the organic carbon by comparing the 013C of pyrolysis and combustion experiments. The TLS on SAM is capable of obtaining high precision measurements of delta13C from C02 evolved during pyrolysis and combustion of solid regolith samples. Because carbonates are expected to be present at abundances of 0.1-1 % in Martian soil, and organics in the ppb range (Webster and Mahaffy, 2011), analog samples must represent this mix of reduced organic carbon and carbonate. The work presented here will examine the use of delta13C of C02 produced during combustion of bulk Mars analog samples as a proxy for detection of reduced organic carbon.

Stern, J. C.↗

The Electromagnetic Compatibility (EMC) Design Challenge for Scientific Spacecraft Powered by a Stirling Power Converter

A 55 We free-piston Stirling Technology Demonstration Convertor (TDC) has been tested as part of an evaluation to determine its feasibility as a means for significantly reducing the amount of radioactive material required compared to Radioisotope Thermoelectric Generators (RTGs) to support long-term space science missions. Measurements were made to quantify the low frequency magnetic and electric fields radiated from the Stirling's 80 Hertz (Hz) linear alternator and control electronics in order to determine the magnitude of reduction that will be required to protect sensitive field sensors aboard some science missions. One identified "Solar Probe" mission requires a 100 dB reduction in the low frequency magnetic field over typical military standard design limits, to protect its plasma wave sensor. This paper discusses the electromagnetic interference (EMI) control options relative to the physical design impacts for this power system, composed of 3 basic electrical elements. They are (1) the Stirling Power Convertor with its linear alternator, (2) the power switching and control electronics to convert the 90 V, 80 Hz alternator output to DC for the use of the spacecraft, and (3) the interconnecting wiring including any instrumentation to monitor and control items 1 and 2.

Sargent, Noel B.↗

An exploration of function analysis and function allocation in the commercial flight domain

The applicability is explored of functional analysis methods to support cockpit design. Specifically, alternative techniques are studied for ensuring an effective division of responsibility between the flight crew and automation. A functional decomposition is performed of the commercial flight domain to provide the information necessary to support allocation decisions and demonstrate methodology for allocating functions to flight crew or to automation. The function analysis employed 'bottom up' and 'top down' analyses and demonstrated the comparability of identified functions, using the 'lift off' segment of the 'take off' phase as a test case. The normal flight mission and selected contingencies were addressed. Two alternative methods for using the functional description in the allocation of functions between man and machine were investigated. The two methods were compared in order to ascertain their relative strengths and weaknesses. Finally, conclusions were drawn regarding the practical utility of function analysis methods.

Mcguire, James C.↗

Communications systems checkout study

The results and conclusions of an engineering study of Space Station communications subsystem checkout are reported. The primary purpose of the study is to recommend specific guidelines and constraints for the design and utilization of the communications subsystem leading to a practical and effective means of onboard checkout implementation. Major study objectives are as follows: (1) identify candidate communications subsystem checkout concepts, (2) determine implementation impacts of feasible concepts, (3) evaluate practicality and effectiveness of alternative concepts, (4) propose baseline modifications to accommodate preferred concepts, and (5) recommend areas for additional investigation. In addition, study results are interpreted, where appropriate, in terms of their applicability to checkout of Shuttle-Orbiter communications subsystem.

Ginter, W. G.↗

Landsat applied to landslide mapping

A variety of features characteristic of rotational landslides may be identified on Landsat imagery. These include tonal mottling, tonal banding, major and secondary scarps, and ponds. Pseudostereoscopic viewing of 9 by 9 in. transparencies was useful for the detailed identification of landslides, whereas 1:250,000 prints enlarged from 70 mm negatives were most suitable for regional analysis. Band 7 is the most useful band for landslide recognition, due to accentuation of ponds and shadows. Examination of both bands 7 and 5, including vegetation information, was found to be most suitable. Although, given optimum terrain conditions, some landslides in Colorado may be recognized, many smaller landslides are not identifiable. Consequently, Landsat is not recommended for detailed regional mapping, or for use in areas similar to Colorado, where alternative (aircraft) imagery is available. However, Landsat may prove useful for preliminary landslide mapping in relatively unknown areas.

Sauchyn, D. J.↗

Lagrange thermodynamic potential and intrinsic variables for He-3 He-4 dilute solutions

For a two-fluid model of dilute solutions of He-3 in liquid He-4, a thermodynamic potential is constructed that provides a Lagrangian for deriving equations of motion by a variational procedure. This Lagrangian is defined for uniform velocity fields as a (negative) Legendre transform of total internal energy, and its primary independent variables, together with their thermodynamic conjugates, are identified. Here, similarities between relations in classical physics and quantum statistical mechanics serve as a guide for developing an alternate expression for this function that reveals its character as the difference between apparent kinetic energy and intrinsic internal energy. When the He-3 concentration in the mixtures tends to zero, this expression reduces to Zilsel's formula for the Lagrangian for pure liquid He-4. An investigation of properties of the intrinsic internal energy leads to the introduction of intrinsic chemical potentials along with other intrinsic variables for the mixtures. Explicit formulas for these variables are derived for a noninteracting elementary excitation model of the fluid. Using these formulas and others also derived from quantum statistical mechanics, another equivalent expression for the Lagrangian is generated.

Jackson, H. W.↗

Spaceborne power systems preference analyses. Volume 2: Decision analysis

Sixteen alternative spaceborne nuclear power system concepts were ranked using multiattribute decision analysis. The purpose of the ranking was to identify promising concepts for further technology development and the issues associated with such development. Four groups were interviewed to obtain preference. The four groups were: safety, systems definition and design, technology assessment, and mission analysis. The highest ranked systems were the heat-pipe thermoelectric systems, heat-pipe Stirling, in-core thermionic, and liquid-metal thermoelectric systems. The next group contained the liquid-metal Stirling, heat-pipe Alkali Metal Thermoelectric Converter (AMTEC), heat-pipe Brayton, liquid-metal out-of-core thermionic, and heat-pipe Rankine systems. The least preferred systems were the liquid-metal AMTEC, heat-pipe thermophotovoltaic, liquid-metal Brayton and Rankine, and gas-cooled Brayton. The three nonheat-pipe technologies selected matched the top three nonheat-pipe systems ranked by this study.

Smith, J. H.↗

Ka-band MMIC microstrip array for high rate communications

In a recent technology assessment of alternative communication systems for the space exploration initiative (SEI), Ka-band (18 to 40 GHz) communication technology was identified to meet the mission requirements of telecommunication, navigation, and information management. Compared to the lower frequency bands, Ka-band antennas offer higher gain and broader bandwidths; thus, they are more suitable for high data rate communications. Over the years, NASA has played an important role in monolithic microwave integrated circuit (MMIC) phased array technology development, and currently, has an ongoing contract with Texas Instrument (TI) to develop a modular Ka-band MMIC microstrip subarray (NAS3-25718). The TI contract emphasizes MMIC integration technology development and stipulates using existing MMIC devices to minimize the array development cost. The objective of this paper is to present array component technologies and integration techniques used to construct the subarray modules.

Lee, R. Q.↗

Ka-band MMIC microstrip array for high rate communications

In a recent technology assessment of alternative communication systems for the space exploration initiative (SEI), Ka-band (18 to 40 GHz) communication technology was identified to meet the mission requirements of telecommunication, navigation, and information management. Compared to the lower frequency bands, Ka-band antennas offer higher gain and broader bandwidths; thus, they are more suitable for high data rate communications. Over the years, NASA has played an important role in monolithic microwave integrated circuit (MMIC) phased array technology development, and currently, has an ongoing contract with Texas Instrument (TI) to develop a modular Ka-band MMIC microstrip subarray (NAS3-25718). The TI contract emphasizes MMIC integration technology development and stipulates using existing MMIC devices to minimize the array development cost. The objective of this paper is to present array component technologies and integration techniques used to construct the subarray modules.

Lee, R. Q.↗

Cytometer on a Chip

A cytometer now under development exploits spatial sorting of sampled cells on a microarray chip followed by use of grating-coupled surface-plasmon-resonance imaging (GCSPRI) to detect the sorted cells. This cytometer on a chip is a prototype of contemplated future miniature cytometers that would be suitable for rapidly identifying pathogens and other cells of interest in both field and laboratory applications and that would be attractive as alternatives to conventional flow cytometers. The basic principle of operation of a conventional flow cytometer requires fluorescent labeling of sampled cells, stringent optical alignment of a laser beam with a narrow orifice, and flow of the cells through the orifice, which is subject to clogging. In contrast, the principle of operation of the present cytometer on a chip does not require fluorescent labeling of cells, stringent optical alignment, or flow through a narrow orifice. The basic principle of operation of the cytometer on a chip also reduces the complexity, mass, and power of the associated laser and detection systems, relative to those needed in conventional flow cytometry. Instead of making cells flow in single file through a narrow flow orifice for sequential interrogation as in conventional flow cytometry, a liquid containing suspended sampled cells is made to flow over the front surface of a microarray chip on which there are many capture spots. Each capture spot is coated with a thin (.50-nm) layer of gold that is, in turn, coated with antibodies that bind to cell-surface molecules characteristic of the cell species of interest. The multiplicity of capture spots makes it possible to perform rapid, massively parallel analysis of a large cell population. The binding of cells to each capture spot gives rise to a minute change in the index of refraction at the surface of the chip. This change in the index of refraction is what is sensed in GCSPRI, as described briefly below. The identities of the various species in a sample of cells is spatially encoded in the chip by the pattern of capture spots. The number of cells of a particular species is determined from the magnitude of the GCSPRI signal from that spot. GCSPRI as used here can be summarized as follows: The cytometer chip is fabricated with a diffraction grating on its front surface. The chip is illuminated with a light emitting diode (LED) from the front. By proper choice of grating parameters and of the wavelength and the angle of incidence of a laser beam, laser light can be made to be coupled into an electromagnetic mode that resonates with surface plasmons and thus couples light into surface plasmons. Coupling of light into a surface plasmon at a given location reduces the amount of incident light reflected from that location. A change in the index of refraction at the surface of a capture spot gives rise to a change in the resonance condition. Depending on the specific design, the change in the index of refraction could manifest itself as a brightening or darkening, a change in the wavelength needed to excite the plasmon at a given angle of incidence, or a change in the angle of incidence needed to excite the plasmon at a given wavelength. Whereas a multiwavelength laser system with multichannel detection would be needed to detect multiple species in conventional flow cytometry, it suffices to use an LED and a single detector channel in the GCSPRI approach: this contributes significantly to reductions in cost, complexity, size, mass, and power. GCSPRI cytometer chips could be made of plastic and could be mass-produced cheaply by use of molding and other methods adopted from the manufacture of digital video disks. These methods are amenable to a high degree of miniaturization: such additional features as fluidic channels, reaction chambers, and fluid-coupling ports could readily be incorporated into the chips, without incurring substantial additional costs.

Fernandez, Salvador M.↗

Cytometer on a Chip

A cytometer now under development exploits spatial sorting of sampled cells on a microarray chip followed by use of grating-coupled surface-plasmon-resonance imaging (GCSPRI) to detect the sorted cells. This cytometer on a chip is a prototype of contemplated future miniature cytometers that would be suitable for rapidly identifying pathogens and other cells of interest in both field and laboratory applications and that would be attractive as alternatives to conventional flow cytometers. The basic principle of operation of a conventional flow cytometer requires fluorescent labeling of sampled cells, stringent optical alignment of a laser beam with a narrow orifice, and flow of the cells through the orifice, which is subject to clogging. In contrast, the principle of operation of the present cytometer on a chip does not require fluorescent labeling of cells, stringent optical alignment, or flow through a narrow orifice. The basic principle of operation of the cytometer on a chip also reduces the complexity, mass, and power of the associated laser and detection systems, relative to those needed in conventional flow cytometry. Instead of making cells flow in single file through a narrow flow orifice for sequential interrogation as in conventional flow cytometry, a liquid containing suspended sampled cells is made to flow over the front surface of a microarray chip on which there are many capture spots. Each capture spot is coated with a thin (approximately 50-nm) layer of gold that is, in turn, coated with antibodies that bind to cell-surface molecules characteristic of one the cell species of interest. The multiplicity of capture spots makes it possible to perform rapid, massively parallel analysis of a large cell population. The binding of cells to each capture spot gives rise to a minute change in the index of refraction at the surface of the chip. This change in the index of refraction is what is sensed in GCSPRI, as described briefly below. The identities of the various species in a sample of cells is spatially encoded in the chip by the pattern of capture spots. The number of cells of a particular species is determined from the magnitude of the GCSPRI signal from that spot. GCSPRI as used here can be summarized as follows: The cytometer chip is fabricated with a diffraction grating on its front surface. The chip is illuminated with a light emitting diode (LED) from the front. By proper choice of grating parameters and of the wavelength and the angle of incidence of a laser beam, laser light can be made to be coupled into an electromagnetic mode that resonates with surface plasmons and thus couples light into surface plasmons. Coupling of light into a surface plasmon at a given location reduces the amount of incident light reflected from that location. A change in the index of refraction at the surface of a capture spot gives rise to a change in the resonance condition. Depending on the specific design, the change in the index of refraction could manifest itself as a brightening or darkening, a change in the wavelength needed to excite the plasmon at a given angle of incidence, or a change in the angle of incidence needed to excite the plasmon at a given wavelength. Whereas a multiwavelength laser system with multichannel detection would be needed to detect multiple species in conventional flow cytometry, it suffices to use an LED and a single detector channel in the GCSPRI approach: this contributes significantly to reductions in cost, complexity, size, mass, and power. GCSPRI cytometer chips could be made of plastic and could be mass-produced cheaply by use of molding and other methods adopted from the manufacture of digital video disks. These methods are amenable to a high degree of miniaturization: such additional features as fluidic channels, reaction chambers, and fluid-coupling ports could readily be incorporated into the chips, without incurring substantial additional costs.

Fernandez, Salvador M.↗

Design Solutions for the Treatment of DMSD in the ISS Water Recovery System

Dimethylsilanediol (DMSD) has been identified as a problematic organic on ISS. This contaminant was initially identified in the Water Processor Assembly (WPA) product water in 2010 by the Total Organic Carbon Analyzer (TOCA). DMSD is not a crew health hazard at the levels observed in the product water, but it may degrade the performance of the Oxygen Generation System (OGS) which uses the WPA product water for electrolysis and does impact the effective operation of the WPA catalytic reactor. To mitigate these impacts, early replacement of the Multifiltration Beds in the WPA is required. An investigation has determined that the decomposition of atmospheric polydimethylsiloxanes (PDMSs) is the primary source of DMSD in the condensate. PDMSs are prevalent on ISS from a variety of sources, including crew hygiene products, adhesives, caulks, lubricants, and various nonmetallics. These PDMSs also contribute to degradation of the CHX hydrophilic coating, rendering it hydrophobic and therefore affecting its ability to transmit water to the condensate bus. In addition, literature research has determined that PDMSs are likely oxidized to DMSD in the atmosphere when exposed to hydroxyl radicals in the ISS atmosphere. To address these mechanisms, filters have been developed for removal of PDMSs from the ISS atmosphere. However, ongoing analysis indicates a significant reduction in atmospheric PDMSs is required to achieve a measurable reduction of DMSD in the condensate. As a result, additional measures are being pursued to mitigate this issue. First, credible sources are being investigated to quantity to the extent possible the significant sources of PDMSs and identify sources that can be reasonably removed from ISS. Second, a Reverse Osmosis technology is being investigated as an alternate means for removing DMSD from the condensate. This paper summarizes the current status of the overall effort to mitigate DMSD in the US condensate.

Perry, Jay↗